• Title/Summary/Keyword: Breakdown cause

Search Result 205, Processing Time 0.028 seconds

An Epidemiological Observation of Fire Accident in Korea (화재사고(火災事故)(WHO-E 916)에 관(關)한 역학적관찰(疫學的觀察))

  • Lee, Chong-Dae;Han, Seong-Un;Bin, Soon-Duk;Chu, In-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1968
  • Epidemiological and statistical observations were made of fire hazards that occurred during the past 18 years, 1948 to 1965. Injury and mortality rates for all ages were computed chronologically. For the years of 1955, 1961 and 1965, all fire accidents were epidemiologically analysed to draw characteristic patterns in relation to the seasonal and 24 hour distribution, causes and sites of accidents etc.. Fire hazards observed herein are the categorys E 916 of the International Classification of Causes of Death, 1955, and includes all accidents caused by fire and explosion of combustible materials. The following conclusion was made: 1. The average number of annual deaths due to fire was 183 and the number of the in jured due to the same cause was 335. The mortality rate per 100,000 population was 0.8 and the ratio of injuries per death was 1.83. 2. The casually rate including both the dead and injured was 5.0 per 100,000 in Seoul, the highest among the provinces and followed by 3.4 in Cheju -Do, 2.1 in Kangwon-Do, 1.7 in Kyunggi-Do accordingly. The other provinces had a range of 0.6 to 1.2. 3. The monthly distribution of fro accidents showed that the winter months, December through February, had more frequent accidents, while the summer season, June through August had less. The 24 hour distribution of accidents showed more cases from 12:00 to 18:00 and less from 4:00 to 10:00 hours. 4. The per cent distribution of causes of accidents showed; 90.0% for careless, 10.0% for arson. The cause of carelessness was further breakdown into; 15.0% for kitchen fire places, 13.8% for fire playing, 9,4% for electrical heating and wires, 8.3% for fuels, 6.3% for matches, 5.2% for ash dumps and the remaining for others. 5. The accidents as classified by place revealed that 56.8% of the total occurred at the common dwelling houses, 11.3 at various industrial workshops, 9.3% at the street shops and the remaining at the miscellaneous places.

  • PDF

Development of a Acoustic Acquisition Prototype device and System Modules for Fire Detection in the Underground Utility Tunnel (지하 공동구 화재재난 감지를 위한 음향수집 프로토타입 장치 및 시스템 모듈 개발)

  • Lee, Byung-Jin;Park, Chul-Woo;Lee, Mi-Suk;Jung, Woo-Sug
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.7-15
    • /
    • 2022
  • Since the direct and indirect damage caused by the fire in the underground utility tunnel will cause great damage to society as a whole, it is necessary to make efforts to prevent and control it in advance. The most of the fires that occur in cables are caused by short circuits, earth leakage, ignition due to over-current, overheating of conductor connections, and ignition due to sparks caused by breakdown of insulators. In order to find the cause of fire at an early stage due to the characteristics of the underground utility tunnel and to prevent disasters and safety accidents, we are constantly managing it with a detection system using image analysis and making efforts. Among them, a case of developing a fire detection system using CCTV-based deep learning image analysis technology has been reported. However, CCTV needs to be supplemented because there are blind spots. Therefore, we would like to develop a high-performance acoustic-based deep learning model that can prevent fire by detecting the spark sound before spark occurs. In this study, we propose a method that can collect sound in underground utility tunnel environments using microphone sensor through development and experiment of prototype module. After arranging an acoustic sensor in the underground utility tunnel with a lot of condensation, it verifies whether data can be collected in real time without malfunction.

Design of the self-oscillation UV flash lamp power supply and the characteristic of its operation using self-resonance of the transformer (트랜스포머의 자가 공진(Self-Resonance)특성을 이용한 자가 발진(Self-Oscillation) UV(Ultra Violet) 발생 플래시램프 전원장치설계 및 그 동작 특성)

  • Kim, Shin-Hyo;Cho, Dae-Kweon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.48-55
    • /
    • 2014
  • These Xenon flashlamp power supply for Ultra Violet has converter with high voltage conversion ratio. General model is composed of transformer with high voltage conversion ratio and voltage doubler rectifier circuit. Purpose of power supply leads dielectric breakdown of Xenon flashlamp and passes current rapidly. When passing current, it has to limit current to avoid over-heat, damage of electrode and acceleration of gas oxidation which are cause of performance degradation of lamps. Generally, inductors and resistors, which are called as "Ballast," are used to limit currents. Generally, Transformer has high turn ratio to make high voltages. But we can get high voltages using the transformer with low turn ratio which is driven with self resonance. Also, an advantage of self resonance is to make a circuit simply through impedance of transformer in resonance frequency which filters output voltage. As using an unique impedance of transformer, the circuit does not need other impedance elements like the ballast. So the power supply assures high efficiency of the arc discharge.

A Study on the Diseases and Pharmacy of the Soumin's Sinsooyul-Pyoyul-Byung theory (소음인(少陰人) 신수열표열병론(腎受熱表熱病論)의 병증(病證) 및 약리(藥理)에 대한 연구(硏究))

  • Joo, Jong-Cheon;Kim, Kyung-Yo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.9 no.2
    • /
    • pp.67-94
    • /
    • 1997
  • The main purpose of this study is to arrange the diseases, principal medicinal substances and the prescriptions for the Soumin's Sinsooyul-Pyoyul-Byung(少陽人 腎受熱表熱病) by historical examination in the viewpoint of the Constitutional Medicine(四象醫學). In this study, first I collected the original texts of the diseases and priscriptions in Dongyi-Soose-Bowon(東醫壽世保元), and described the development process of the Soumin(少陽人)'s diseases and priscriptions by comparing with the contents in Dongyi-Soose-Bowon(東醫壽世保元). Next, I collected the efficacy of the medicinal substances and priscriptions by the examination of successive literatures referred it, and tried to explain the efficacy of each medicinal substances in the viewpoint of the Constitutional Medicine(四象醫學) by the analysis of successive literatures. As a result, the conclusions could be summarized as follows. 1. The Differentiation of Syndromes(辦證) in the Existing Medicine(旣存醫學) was formed according to the Eight Principal Syndromes(八綱), the Five Elements(五行), the Merdian system(經絡), therefore there were many confusions with the changes of the times. The differentiation of Syndromes(辦證) in the Constitutional Medicine(四象醫學) was formed according to the pathological change of Ascending and Descending Yin Yang(陰陽升降) in the Four Internal Organs(四臟), therefore, there was the consistency in the recognition of diseases. 2. The classification of the Soumin's Pyoyul-Byung(少陽人 表熱病) was divided into Yukuang Disease(鬱狂證) and Mangyang Disease(亡陽證) according to sweating or not. The conception of these diseases was mostly achived in Shanhanlun(優寒論). The treatment of Shanhanlun(優寒論) was alike to that of Dongyi-Soose-Bowon(東醫壽世保元) in a part. 3. Je ma, Lee thinked that the cause of the Soumin's Pyoyul-Byung(少陽人 表熱病) is the breakdown of the balanced equilibrium in ascending and descending Yin Yang(陰陽升降) for a Large Sin and a Small Bi(腎大脾小), and it is treated by warming and ascending Yang(溫補升陽). 4. The medicinal substances composing prescriptions for the Soumin's Pyoyul-Byung(少陰人 表熱病) is characterized with the efficacy of Ascending Yang and supplying Qi(升陽益氣) and regulating the digestive organs with the efficacy of warming it. 5. The medicinal substances composing the precriptions for the Soumin's Pyoyul-Byung(少陰人 表熱病) is divided into four parts with the state of Yang Qi(陽氣) in the disease it used. 6. The purpose of prescriptions for the Soumin's Pyoyul-Byung(少陰人 表熱病) is to strengthen the Soumin(少陰人)'s Yangnan Qi(陽暖之氣). Je ma, Lee kept the principle not to mix with another constitution's medicinal substances in the creation of the priscription.

  • PDF

The Characteristics of Disaster by Track of Typhoon Affecting the Korean Peninsula (한반도 영향 태풍의 이동경로에 따른 재해 특성)

  • Ahn, Suk-Hee;Kim, Baek-Jo;Lee, Seong-Lo;Kim, Ho-Kyung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.29-36
    • /
    • 2008
  • The purpose of this study is to examine the characteristics of disaster associated with typhoon passed through the sea areas excluding the South Sea around the Korean Peninsula. First, Korean peninsula-affecting typhoons were divided into their track patterns of passing through the Korean West Sea and East Sea based on typhoon data from 1951 to 2006 provided by Regional Specialized Meteorological Center(RSMC)-Tokyo. Then, annual and monthly frequency and intensity of typhoon in each pattern was examined. In particular, typhoon related damages during the period of 1973 to 2006 were analyzed in each case. Results showed that since early 1970, in the West Sea case, typhoon becomes weaker without significant change in frequency, while in the East Sea case, it becomes stronger with an increasing trend. It is also found that the high amount of typhoon damage results from the submergence of houses and farmlands in the East Sea case, while it is due to the breakdown of houses, ships, roads and bridges in the West Sea case. In addition, it is revealed from the analysis of rainfall and maximum wind speed data associated with typhoon disasters that the main cause of occurring typhoon disasters seem to be qualitatively related to strong wind in the West Sea case and heavy rainfall in the East Sea case.

A Case Study of the Risk Identification in Construction Project (건설사업의 리스크 식별에 관한 사례연구)

  • Ahn, Sanghyun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.15-23
    • /
    • 2015
  • In the construction industry, risk management has gained constant attention as the factor not only to evaluate global competitiveness of the country but also to secure competitiveness of public institutions and private companies. For effective construction risk management, the specific work process improvement that can be employed in the field in terms of risk management of the entire corporation such as financial, insurance and safety management is necessary. To manage construction risks, what is important is the step to identifying inherent risks in the construction project. The identification of risks will be followed by the step to seeking ways to establish and manage strategies responding to the risks. This study suggests ways and processes to make a checkslit to identify risks through case studies. To that end, the focus will be placed on working process improvement of risk identification among stages to manage construction risks such as risk identification and analyses, planning to respond to risks, risk monitoring and management. The case study checklists show that setting up the system to classify risks by stage is helpful to figure out causes of risks to reduce or eliminate risk factors. The checklist making process that considers features of the project is expected to contribute to successful completion of the project by enabling effective risk identification and systematic risk management.

The Results of the Endoscopic Decompression for the Treatment of Haglund's Disease (Haglund씨 병에서 시행한 내시경적 감압술의 결과)

  • Ahn, Su-Han;Cho, Hyung-Lae;Hong, Seong-Hwak;Wang, Tae-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.2
    • /
    • pp.197-202
    • /
    • 2008
  • Purpose: Haglund's disease represents a painful heel caused by mechanically induced inflammation of the retrocalcaneal bursa and insertional Achilles tendinosis may coexist. Traditional open surgery can cause complications such as skin breakdown, painful scar and altered sensation around the heel. Endoscopic treatment offers the advantages that are related to minimally invasive procedure and we evaluate the clinical results and operative techniques of endoscopic decompression of retrocalcaneal space for Haglund's disease. Materials and Methods: Our retrospective study included seven heels in six consecutive patients for which nonoperative treatment had failed and endoscopic decompression was performed. The mean age was forty-one years (range, 28 to 53 years). All of the patients had typical complaints of inflammation of the retrocalcaneal bursa and Fowler-Philip angle of more than $75^{\circ}$ and positive parallel pitch lines were present on the lateral calcaneal radiograph. The endoscopic procedure consists of the resection of inflamed retrocalcaneal bursa and enough bone to prevent impingement of the bursa between the calcaneus and Achilles tendon. All patients were evaluated with radiologic angle, visual analogue scale (VAS) for pain and Ogilvie-Harris functional score. The mean follow-up was 18 months (range, 15 to 21 months). Results: The mean operation time was 61 minutes (range, 50 to 85 minutes). VAS for pain and Fowler-Philip angle were decreased from preoperative 8.7 and $82^{\circ}$ to postoperative 2.3 and $57^{\circ}$, respectively. One patient with ankylosing spondylitis had a fair result, 2 patients had good results and the remaining 3 patients had excellent results according to Ogilvie-Harris functional score. There were no surgical complications such as infection, Achilles tendon avulsion or abnormal heel sensation. Conclusion: The endoscopic decompression for Haglund's disease was demonstrated to have several advantages including low morbidity, allowance of functional rehabilitation, short recovery time and quick sports resumption. However a comparative study is needed to determine the value of endoscopic decompression and particular caution should be exerted for the enthesiopathy.

  • PDF

An Effect of Revolutions Per Minute (r.p.m) in the Noise Characteristics (기계소(機械騷) 음(音)과 회전(回轉) 속도(速度))

  • Cha, Bong-Suk
    • Journal of Preventive Medicine and Public Health
    • /
    • v.10 no.1
    • /
    • pp.94-101
    • /
    • 1977
  • Noise pollution, both in the environment and in the workplace, has been recognized as a major health hazard -one that can impair not only a person's hearing but also his physical and mental well-being. As industrialization progresses, the prevalence rate of occupational diseases is increasing, especially hearing loss, which has the highest prevalence rate among the occupational diseases. The major cause of noise is the construction of various large industries without any regulation of noise sources. Therefor, we must establish an enactment to control mechanical noise sources. as soon as possible. For the purpose of controlling the noise source, we must have exact data about such things as the sound level, the frequency of the peak sound and the revolutions per minute (r.p.m.) of the machine (a measure of the power of its motor). This study was undertaken in order to define the noise characteristics, the power of the machine's motor, the change of the sound level and the peak sound as the r.p.m. increases, and the permissible exposure time. The sample size of this study was 74 machines at 11 plants in 6 industries. The results are as follows; 1. The breakdown of the types of mechanical noise noted was : 63.6% continuous normal sound, 26.9% intermittent sound, 4.7% continuous repeating sound and 4.6% impulsive sound. 2. With respect to the type of industry, the overall sound level was the highest in the mechanical industry, with $103.8{\pm}2.8dB(A)$, and lowest in the textile industry, with $89.2{\pm}1.43dB(A)$. 3. With respect to the type of machine, the highest sound level was 124 dB(A) caused by Gauzing(II), in the mechanical industry, and the lowest was 76 dB(A) caused by Attachment (Jup Chack) (I) in the timber industry. 4. The shortest permissible exposure time to Gauzing(II) in the mechanical industry was less than 15 minutes. 5. Among 74 machines, 68.2% of the peak sound was situated in the high frequency range (52.7% at 2 KHz, 4.1% at 4 KHz and 1.4% at 8 KHz). 41.8% of the peak sound was in the middle frequency range (4.1% at 250Hz, 14.8% at 500Hz and 22.9% at 1KHz). 6. If one machine had two motors or more, the peak sound was shifted to the low frequency range. 7. As the r.p.m. increased, the overall and peak sound levels were increased without any change of the frequency of the peak sound. 8. Whenever the machines had the same kind and the same r.p.m., the overall and peak sounds were changed by the physicochemical characteristics of the raw materials and the management.

  • PDF

Nonchange of Grounding Current due to Equipment Measuring Insulation Resistance (절연저항 측정 장치에 의한 지락사고 전류의 비변화)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.175-180
    • /
    • 2015
  • With progress in industrialization, facilities for generating, delivering, and receiving high levels of electric power are in great demand. The scale of electric power equipment is increasing in both size and complexity. This has contributed to the development of our modern, high-tech and information-based society. However, if the generation of electric power is suspended due to unexpected accidents at power facilities or power stations, a range of equipment the operations of which are dependent on electric power can be damaged, causing substantial socioeconomic losses in an industrial society. A great deal of time and money would be expended to repair damaged facilities at a power station, causing enormous economic loss.In order to detect the deterioration processes of power cables, and to prevent the destruction of power cables, the operation status of power cables should be monitored on a regular basis. We have installed equipment at Korea Western Power Co., Ltd., located in Taean, in order to predict and prevent the destruction of power cables. This is an entirely new installation: a set of equipment invented specifically to measure the insulation resistance of power cables. Installation of the equipment does not cause the flow of earth fault current. This ensures accurate measurement of insulation resistance values by the equipment. We have been studying this equipment in order to develop preventive technology that would show the deterioration processes of power cables.

Relationship between the Locations of Tunnel Entrance and Areas Affected by Deforestation in the Forest in Korea (산림관통 터널 입출구부 위치와 훼손 면적의 관계)

  • Kim, Dong-Pil;Hong, Suk-Hwan;Choi, Song-Hyun;Lee, Sang-Cheol;Ahn, Mi-Yeon
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.1
    • /
    • pp.104-111
    • /
    • 2017
  • The construction of road tunnels and bridges have delivered driving efficiency and stability based on developed engineering technology. Tunnels have the advantage of reducing the deforested area compared with other road construction methods. Since a tunnel is an underground passageway dug through the surrounding soil/earth/rock and enclosed except for the entrance and exit, commonly at each end, it does not cause a large amount of deforestation. This study surveyed the deforested areas at each end of the tunnel by the design of the tunnel entrance and exit and forest topography to minimize the amount of deforestation caused by road construction. A survey was done on a total of 150 tunnels (300 entrances and exits) on several main roads in Korea. The deforested area of each tunnel was collected by a breakdown of the entrance area and the upper area of the tunnel. According to the results of Kruskal-Wallis analysis, it was found that there was statistically a significant relation between the location of tunnels and the amount of deforestation by the topographical access type of the tunnels. The tunnel with 'facing orthogonal to incline' type access caused the smallest deforestation while the the tunnel with 'facing to valley' and 'parallel with incline' type accesses caused large deforestation during tunnel construction. Tunnel positioning in the light of topography can reduce the deforested area by up to 1.5ha at each tunnel.