Machining Characteristics of WEDM due to Electrical Conductivity of Dielectric (방전액의 전도율의 변화에 따른 와이어방전가공의 가공특성)

  • Kim, Chang-Ho;Kang, Jae-Won
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.15-21
    • /
    • 2006
  • This work deals with the electrical conductivity of dielectric on output parameters such as metal removal rate and surface roughness value of a carbon steel(SM25C) and sintered carbides cut by wire electrical discharge machining (WEDM). Dielectric has several functions like insulation, ionization, cooling, the removal of waste metal particles. The presence of minute metal particles(debris) in spark gap contaminates and lowers the breakdown strength of dielectric. And it is considered that too much debris in spark gap is generally believed to be the cause of arcing. Experimental results show that increases of cobalt amount in carbides affects the metal removal rate and worsens the surface quality as a greater quantity of solidified metal deposits on the eroded surface. Lower electrical conductivity of the dielectric results in a lower metal removal rate because the gap between wire electrode and workpiece reduced. Especially, the surface characteristics of rough-cut workpiece and wire electrode were analyzed too. Debris were analyzed also through scanning electron microscopy(SEM) and surface roughness tester. Micro cracks and some of electrode material are found on the workpiece surface by energy dispersive spectrometer(EDS).

A Study on RF High Power Durability of Al-Cu Alloy Electrodes Used in Ladder-type SAW(surface acoustic wave) Filters (Al-Cu 합금 전극막 구조를 갖는 사다리형 SAW filter의 RF-고전력 내구성 특성 고찰)

  • 김남철;이기선;서수정;김지수;김윤동
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.5
    • /
    • pp.435-443
    • /
    • 2001
  • As power durable RF SAW filters, AL-(0∼2wt%)Cu alloy multi-layered thin electrodes were deposited on 42° LiTaO$_3$ piezoelectric substrates by magnetron sputtering process, and then ladder-type RF SAW filters, satisfying the electrical specification of CDMA transmission band, were fabricated through optimizing SAW resonator structures. The temperature of film electrodes in SAW filter was increased with RF power, and reached the maxima to cause a failure of SAW filters at the cut-off frequencies of the RF filter band. As RF power increases, the electrodes of Al-Cu alloy showed higher power durability than that of pure Al. The multi-layer laminated film of Al-1wt.% Cu/Cu/Al-1wt%Cu resulted in the best power durability up to 4W of RF power. Every film electrode, however, was destroyed within seconds whenever applying a critical RF power to SAW filters, regardless of the composition and structure of film electrodes. The breakdown of film electrodes under FR power seems to believe due to the fatigue of electrodes caused by repetitive cyclic stress of surface acoustic wave, which is amplified as RF power increases.

  • PDF

Experimental study on the changes of serum free fatty acid and blood sugar during hemorrhagic shock (출혈성(出血性) Shock 에 출현(出現)되는 유리지방산(遊離脂肪酸) 및 혈당량(血糖量)의 변동(變動)에 관(關)하여)

  • Kim, Hyong-Se
    • The Korean Journal of Pharmacology
    • /
    • v.2 no.1 s.2
    • /
    • pp.99-109
    • /
    • 1966
  • It has been known that the pronounced hypotension resulting from hemorrhage gives rise to compensatory stimulation of the adrenosympathetic system, which leads to an increase of liberation of catecholamines from sympathetic nervous system and adrenal medulla. It is obvious, therefore, that numerous physiological and biochemical changes during the hemorrhagic hypotention might be mediated through the increased liberation of catecholamines. Although an extensive studies have been reported on changes of protein and carbohydrate metabolism in hemorrhagic shock a few studies on the changes of lipid metabolism have been reported. Levenson(1961) observed a marked increase of serum lipids content during hemorrhagic shock and also noticed a marked elevation of serum free fatty acids. He suggested that these effects were due to mobilization and accelerated metabolic breakdown of lipids which might be resulted by sympathetic stimulation as a cause. To elucidate the mechanism of this, author studied the change of serum free fatty acids and blood sugar with relation to catecholamines during experimentally induced hemorrhagic shock in dog. Healthy male mongrel dogs weighing approximately 15kg were used. Under the general anesthesia with pentobarbital, rapid hemorrhage was produced from the femoral artery maintaining blood pressure level of 40 mmHg measured by the manometer connected with the opposite femoral artery throughout the experiment. Serum free fatty acids(FFA) and blood sugar were measured by the methods of Dole(1956) and Folin-wu,(1920) respectively. Tissue catecholamine was measured by Shore and Olin method(1958) using Aminco-Bowman spectrophotofluorometer.

  • PDF

Improvement of ESD (Electrostatic Discharge) Protection Performance of NEDSCR (N-Type Extended Drain Silicon Controlled Rectifier) Device using CPS (Counter Pocket Source) Ion Implantation (CPS 이온주입을 통한 NEDSCR 소자의 정전기 보호 성능 개선)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.1
    • /
    • pp.45-53
    • /
    • 2013
  • An electrostatic discharge (ESD) protection device, so called, N-type extended drain silicon controlled rectifier (NEDSCR) device, was analyzed for high voltage I/O applications. A conventional NEDSCR device shows typical SCR-like characteristics with extremely low snapback holding voltage. This may cause latch-up problem during normal operation. However, a modified NEDSCR device with proper junction/channel engineering using counter pocket source (CPS) ion implantation demonstrates itself with both the excellent ESD protection performance and the high latch-up immunity. Since the CPS implant technique does not change avalanche breakdown voltage, this methodology does not reduce available operation voltage and is applicable regardless of the operation voltage.

Experimental Study on the Electrostatic Discharge in the HDD Spindle System Using Fluid Dynamic Bearings (유체동압베어링을 사용하는 하드디스크 드라이브 스핀들 시스템에서 발생하는 정전기 방전에 관한 실험적 연구)

  • Kang, Min-Gu;Jang, Gun-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.1 s.106
    • /
    • pp.75-80
    • /
    • 2006
  • This paper introduces the mechanism of the ESD(electrostatic discharge) in the HDD spindle system using FDBs(fluid dynamic bearings). When a HDD(hard disk drive) spindle system is rotating, triboelectric charging occurs in the FDBs through the friction between the lubricant and the rotating shaft or between the lubricant and stationary sleeve. And this electrostatic charge is accumulated in the rotating parts of the HDD spindle system because they are insulated from the ground by the lubricant. This research shows experimentally that the behavior of electric charge and discharge in the FDB spindle system is the same as that of a capacitor. It also measures the electrostatic voltage difference between the rotating and stationary parts in the FDB spindle system due to the change of humidity, supporting load and motor speed. This research shows that the control of ESD is required in the HDD spindle system using FDBs, because the electrostatic charge accumulated in the FDB spindle system may cause the breakdown damage of the GMR head and data loss consequently.

Embedded System Design with COS LoRa technology (COS LoRa 기반의 임베디드 시스템 설계)

  • Hong, Seonhack;Cho, Kyungsoon;Yoon, Jinseob
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.3
    • /
    • pp.29-38
    • /
    • 2018
  • It is the approach of embedded system design that analyzes COS(Cut Out Switch) failure in the power distribution and an instantaneous breakdown of power distribution supply could cause the weakness of industrial competence and therefore we need to feed the stable power distribution with developing the technology of open-source embedded system. In this paper, we apply the LoRa technology which is the Internet of Things(IoT) protocol for low data rate, low power, low cost and long range sensor applications. We designed the hardware and software architecture setup and experimented the embedded system with network architecture and COS monitoring system including accelerometer for detecting the failure of distribution line and sensing the failure of its fuse holder by recognizing the variation and collision and afterwards sending the information to a gateway. With experimenting we designed the embedded platform for sensing the variation and collision according to the COS failure, monitoring its fuse holder status and transferring the information of states with LoRa technology.

A Security Module for Vehicle Network Communication (차량 네트워크 통신용 보안 모듈)

  • Kwon, Byeong-Heon;Park, Jin-Sung
    • Journal of Digital Contents Society
    • /
    • v.8 no.3
    • /
    • pp.371-376
    • /
    • 2007
  • Many modules such as controller, sensor, telematics terminal, navigation, audio and video are connected each other via vehicle network (CAN, MOST, etc). Futhermore, users can have ITS or internet services in moving by connecting to wireless mobile network. These network capabilities can cause a lots of security issues such as data hacking, privacy violation, location tracking and so on. Some possibilities which raise a breakdown or accident by hacking vehicle operation data (sensor, control data) are on the increase. In this paper, we propose a security module which has encryption functionalities and can be used for vehicle network system such as CAN, MOST, etc. This security module can provide conventional encryption algorithms and digital signature processing functionality such as DES, 3-DES, SEED, ECC, and RSA.

  • PDF

A Case Report of chronic urticaria with cerebral hemorrhage (腦出血을 동반한 慢性 두드러기 患者의 治驗 1例)

  • Kim, Chang-Hwan;Sun, Young-Jae;Kim, Hyun-Gi
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.15 no.1
    • /
    • pp.285-290
    • /
    • 2002
  • Urticaria is classified as Eunjin in Oriental Medicine. The intrinsic causes include digestive system disorder, food poison, parasite, female reproductive health problem, nervous breakdown, and disorder of endocrine hormone. The extrinsic sources include all kinds of insect bites or stings, medications, pollen, dirt, and toxic smells. Some unknown sources also produce urticaria. The urticaria that lasts for more than six weeks, is categorized as chronic urticaria which is not very different from acute urticaria that occurs rapid but for a short period. The chronic urticaria may come every day, and its symptoms can even get worse at irregular or regular intervals. The cycle is hard to predict. It could be weeks or years. In clinical treatments, the syndromes of patient's chronic urticaria with cerebral hemorrhage have been analyzed and identified as follows: The diagnosis by asking the patient's case history showed that the root cause was retention of food resulting from dysfunction of the spleen and stomach. First, Pyeongwisan was dosed. From the syndrome differentiation with four diagnostic methods, we diagnosed the symptoms as Poong yoel (wind-heat). Then, Hyeongbangpaedocksangamibang was prescribed to get very effective results.

  • PDF

A Study on the Types and Solves Plan of Popular Complaint by Construction Work Types - Focus on the Gwang-Ju City - (건축공사 공종에 따른 진정민원의 유형과 처리에 관한 연구 - 광주 지역을 중심으로 -)

  • Song, Hyuk;Go, Seong-Seok;Park, Hyeon-Ku
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.97-105
    • /
    • 2005
  • As construction project is becoming larger, construction progress and works are more various and complex according to recent Korean construction tendency. The growth of construction induces much pollution on the progress of construction and the problems due to the construction pollution are raised into social problem strongly, because it is increasing the need on the quality of lift and the desire of clean environment. This study aimed to seek far the effective solving plan of the construction popular complaints by surveying the real condition of construction popular complaints and analyzing the cause and tansaction period of popular complaints. For this study, the laws related and popular complaints were analysed focusing on the documents in low district offices of Gwangju from 2000 to 2004. As a result, the types of construction popular complaints were divided into 17 and the causes were as follows in order: crack and subsidence of ground(14.90%), infringement of private life(11.55%), noise(10.80%), infringement of a right to sunshine(10.07%) and breakdown(6.7%). Consequently, it is considered that these complaints are occurred by physical and environmental causes.

Analysis of Electric Shock Accident on 4.16 kV Class Circuit breaker for Power Plant (발전소용 4.16 kV급 차단기에서 감전사고 사례 분석)

  • Park, Nam-Kyu;Song, Jae-Yong;Kim, Jin-Pyo;Goh, Jae-Mo
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.54-60
    • /
    • 2014
  • This paper describes electric shock accidents on a 4.16 kV class circuit breaker for power plant. Electric shock accidents mostly involve damage of human life, in comparison with electrical fire, rate of human death tend to be higher in electric shock accidents. Specially, in a high voltage facilities rate of human death comprised about 43.7% by electric shock accidents. If electric shock accidents happen in a 4.16 kV class circuit breaker for power plant, then the power plant discontinue power production. Electric shock accidents in a power plant have a great ripple effect such as an electric power shortage. In this paper, we analyzed electric shock accidents on a 4.16 kV class circuit breaker for power plant. From the analysis results, we confirmed a cause of electric shock accidents on a 4.16 kV class circuit breaker, it happened by defect of interlock equipment or occurrence of breakdown between first feeder contactor and shielding plate. In order to reduce electric shock accidents on a 4.16 kV class circuit breaker, the power plant should consider improvement of interlock equipment and insulation of feeder contactor in circuit breaker.