• 제목/요약/키워드: Breakdown Insulation

검색결과 575건 처리시간 0.031초

가열조건이 폴리아미드지의 절연특성에 미치는 영향 (A Study on the heating conditions affect on the insulation characteristics of polyamid papers)

  • 선종호;김우성;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2047-2049
    • /
    • 2000
  • In this study, we describe comparison of insulation characteristics of polyamid papers with heating conditions. The partial discharge behavior until breakdown and breakdown strength for thermal degradation films are observed in $SF_6$ gas chamber. The four layered NOMEX films of thickness of 50${\mu}m$ were used as solid insulation films and the sphere of which diameter is 40mm to sphere electrode system was used and each insulation films were inserted between sphere electrodes. The used gas pressure was 1.0bar and used temperature was each of 250$^{\circ}C$, 270$^{\circ}C$, 300$^{\circ}C$, 320$^{\circ}C$, 350$^{\circ}C$ and the voltage were applied until breakdown films.

  • PDF

송전급 HTS 케이블용 반합성지의 두께에 따른 절연특성 연구 (A Study on Insulation Characteristics by Thickness of Laminated Polypropylene Paper for an HTS Transmission Cable)

  • 최진욱;최재형;김해종;조전욱;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권1호
    • /
    • pp.35-38
    • /
    • 2009
  • The high temperature superconducting(HTS) power cable, as a key component of the next generation power transmission system, operates cost-effectively because of much less transmission loss. Currently, a world-wide research has been undertaken actively. In this research, we designed insulation thickness and investigated thickness effect of laminated polypropylene paper(LPP) which is insulation material of HTS cable in case of AC and impulse breakdown.

고온초전도 케이블의 응용을 위한 PPLP의 절연파괴 특성연구 (Study on the Breakdown Performance of Synthetic Polypropylene Laminated Paper for Application of a HTS Cable)

  • 곽동순;김영석;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.65-68
    • /
    • 2003
  • In this paper, we researched breakdown characteristics of paper/liquid nitrogen composite insulation system for application of a high temperature superconducting cable. And, we have studied the AC breakdown performance of paper/ice composite insulating system immersed in liquid nitrogen. The electric strength in this paper/ice composite system is higher than that of paper/liquid nitrogen system. Furthermore this system shows a self-healing type breakdown behavior. Among the many kinds of liquid to be immersed and frozen to the ice, deionized water gives the highest electric breakdown strength. The paper/ice composite insulation system is thought to be one of good candidate for the electrical insulating system at cryogenic temperature.

  • PDF

주상변압기의 절연매질인 광유의 절연파괴특성에서 분해생성물의 영향 (Effect of Decomposition Product on the Insulation Characteristics of Mineral Oil as Insulation Medium of Distribution Transformer)

  • 임동영;박숭규;박철호;김기채;이광식;최은혁
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.52-59
    • /
    • 2014
  • This paper deals with the effect of decomposition products which occur in breakdown of mineral oil, on the insulation characteristics of its oil. Breakdown tests in the oil were conducted by the proposed experimental methods under a quasi-uniform field and AC HV (60Hz). The breakdown voltage in the oil shows characteristics of dispersion from successive breakdowns and, it is found that there are three patterns of the decomposition products behavior at the process of breakdown progress in the oil. Finally, the breakdown voltage dispersion in the oil can be described in detail based on the behavior patterns of the decomposition products and its diffusion time.

절연파괴 사례분석을 통한 진공함침 방식 발전기 고정자권선의 절연특성 연구 (A Study on Insulation Property of VPI Type Generator Stator Winding Through the Case Analysis of Insulation Breakdown)

  • 공태식
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.311-316
    • /
    • 2010
  • According to increase of combined cycle power generation, the manufacturing market of gas turbine generator has become more competitive, so there is high pressure on the manufacturer to reduce generator price. Global VPI(vacuum pressure impregnation) method is effective to save the production cost and time for manufacturing stator windings, but it has an abrasion problem by vibration between stator windings and slots. This paper presents the insulation breakdown case, which is for VPI type generator during high voltage insulation tests, and also shows the cause analysis, repair works as well as reliability test. the purpose of this paper is to understand the insulation properties of VPI type generator and to know prevention of insulation weakness.

가속된 열적 스트레스에 의한 PAI / Nano Silica 하이브리드 코일의 절연수명 추정 (Estimation of Insulation Life of PAI/Nano Silica Hybrid Coil by Accelerated Thermal Stress)

  • 박재준
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.52-60
    • /
    • 2019
  • In this paper, four types of insulation coils were fabricated by adding various kinds of glycols to improve the flexibility and adhesion of insulating coils in varnish dispersed with PAI / Nano Silica_15wt%. The applied voltage and frequency were 1.5 kV / 20 kHz for accelerated life evaluation. Through the 6th temperature stress level, the cause of the insulation breakdown of the coil was ignored and only the breakdown time was measured. The Arrhenius model was chosen based on the theoretical relationship between chemical reaction rate and temperature for estimating the insulation life of the coil due to accelerated thermal stress. Three types of distributions (Weibull, Lognormal, Exponential) were selected as the relationship between thermal stress model and distribution. The average insulation lifetime was estimated under the temperature stress of four types of insulation coils through the relationship between one kind of model and three kinds of distributions.

Influence of SF6/N2 Gas Mixture Ratios on the Lightning Streamer Propagation Characteristics of 22 kV MV Circuit Breaker

  • Gandhi, R.;Chandrasekar, S.;Nagarajan, C.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1663-1672
    • /
    • 2018
  • In recent times, gas insulated medium voltage (MV) circuit breakers (CB) form a vital component in power system network, considering its advantages such as reduced size and safety margins. Gas insulation characteristics of circuit breakers are generally measured by lightning impulse (LI) test according to IEC standard 60060-1 as a factory routine test. Considering the environmental issues of $SF_6$ gas, many research works are being carried out towards the mixture of $SF_6$ gases for high voltage insulation applications. However, few reports are only available regarding the LI withstand and streamer propagation characteristics (at both positive and negative polarity of waveform) of $SF_6/N_2$ gas mixture insulated medium voltage circuit breakers. In this paper, positive and negative polarity LI tests are carried out on 22 kV medium voltage circuit breaker filled with $SF_6/N_2$ gas mixture at different gas pressures (1-5 bar) and at different gas mixture ratios. Important LI parameters such as breakdown voltage, streamer velocity, time to breakdown and acceleration voltage are evaluated with IEC standard LI ($1.2/50{\mu}s$) waveform. Weibull distribution analysis of LI breakdown voltage data is carried out and 50% probability breakdown voltage, scale parameter and shape parameter are evaluated. Results illustrate that the $25%SF_6+75%N_2$ gas filled insulation considerably enhances the LI withstand and breakdown strength of MV circuit breakers. LI breakdown voltage of circuit breaker under negative polarity shows higher value when compared with positive polarity. Results show that maintaining the gas pressure at 0.3 MPa (3 bar) with 10% $SF_6$ gas mixed with 90% $N_2$ will give optimum lighting impulse withstand performance of 22 kV MV circuit breaker.

Toughened Epoxy/Rubber계면의 교류 절연파괴 현상에 관한 연구 (Study on the AC Interfacial Breakdown Prosperities in the Interface between Toughened Epoxy and Rubber)

  • 김태형;배덕권;이동규;정일형;김충혁;이홍표;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.771-774
    • /
    • 2000
  • Recently, complex insulation method is used in insulation system for underground power delivery devices. Considering the interfaces which affect stability of insulation system, By modeling interface between Epoxy and Rubber, AC interfacial breakdown properties with variation of many conditions to influence on electrical properties were investigated. In this paper, toughened Epoxy and Silicone rubber were used for materials to make interface .

  • PDF

Analysis of Insulation Diagnosis and Failure in Stator Windings of Air-Cooled Gas Turbine Generator

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Kyeong-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.421-424
    • /
    • 2016
  • In order to evaluate the insulation deterioration in the stator windings of air-cooled gas turbine generators(119.2 MVA, 13.8 kV) which has been operating for more than 15 years, diagnostic test and AC dielectric breakdown test were performed on phases A, B and C. Diagnostic test included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B, and C) of generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable condition. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. Although phase A of generator stator windings failed at breakdown voltage of 29.0 kV, phases B and C endured the 29.0 kV. The breakdown voltage in all three phases was higher than that expected for good-quality windings (28.6 kV) in a 13.8 kV class generator.

Study on Reliability of Water Absorption Diagnosis through Precise Water Absorption Test

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.772-777
    • /
    • 2012
  • Accidents caused by water absorption in water-cooled generator stator windings often occur all over the world. The absorption into the insulator of the coolant, which is used to cool down the heat generated by stator windings during operation, leads to the deterioration of dielectric strength, and insulation breakdown. An insulation breakdown may cause not only an enormous economic loss but also a very serious grid accident that would compromise stable supply of electric power. More than 50 % of domestic generators have been in operation for more than 15 years, and water absorption tests performed on 50 water-cooled generator stator windings during a five-year planned preventive maintenance period beginning in 2006 identified water absorption problems in 10 of them, all of which required repair. Because the existing water absorption test detects this problem by utilizing stochastic methods after measuring the capacitances at the final positions of insulation breakdown, its accuracy is limited. This study demonstrates that water absorption can be more accurately diagnosed by utilizing method along with a more precise one.