Modification of Current Leak Before Break Criteria for Nuclear Piping System (원자력 발전소 배관에 대한 파단전누설 개념 적용기준의 수정)

  • Yu, Yeong-Jun;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.6
    • /
    • pp.1862-1871
    • /
    • 1996
  • The puopose of this paper is sto modify the current LBB criteria. The validity of current LBB criteria and current standard LBB analysis mehtod are evaluated using linear elastic fracture mechanics and elastic-plastic fracture mechanics. The results of evaluation demonstrate that the current LBB driteria are very conservative and some level of margins already exist in the standard LBB analysis method. Thus, the margin on load .root. and margin on crack size 2 can be eliminated to extend LBB application for the samller diameter pipe.

Thermal Fluid Mixing Behavior during Medium Break LOCA in Evaluation of Pressurized Thermal Shock

  • Jung, Jae-Won;Bang, Young-Seok;Seul, Kwang-Won;Kim, Hho-Jung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.635-640
    • /
    • 1998
  • Thermal fluid mixing behavior during a postulated medium-size hot leg break loss of coolant accident is analyzed for the international comparative assessment study on pressurized thermal shock (PTS-ICAS) proposed by OECD-NEA. The applicability of RELAP5 code to analyze thermal fluid mixing behavior is evaluated through a simple modeling relevant to the problem constraints. Based on the calculation result, the onset of Thermal stratification is investigated using Theofanous's empirical correlation. Sensitivity calculations using a fine node model and crossflow model are also performed to evaluate the modeling capability on multi-dimensional characteristics related to thermal fluid mixing.

  • PDF

An Application of Realistic Evaluation Methodology for Large Break LOCA of Westinghouse 3 Loop Plant

  • Choi, Han-Rim;Hwang, Tae-Suk;Chung, Bub-Dong;Jun, Hwang-Yong;Lee, Chang-Sub
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.513-518
    • /
    • 1996
  • This report presents a demonstration of application of realistic evaluation methodology to a posturated cold leg large break LOCA in a Westinghouse three-loop pressurized water reactor with 17$\times$17 fuel. The new method of this analysis can be divided into three distinct step: 1) Best Estimate Code Validation and Uncertainty Quantification 2) Realistic LOCA Calculation 3) Limiting Value LOCA Calculation and Uncertainty Combination RELAP5/MOD3/K [1], which was improved from RELAP5/MOD3.1, and CONTEMPT4/MOD5 code were used as a best estimate thermal-hydraulic model for realistic LOCA calculation. The code uncertainties which will be determined in step 1) were quantified already in previous study [2], and thus the step 2) and 3) for plant application were presented in this paper. The application uncertainty parameters are divided into two categories, i.e. plant system parameters and fuel statistical parameters. Single parameter sensitivity calculations were performed to select system parameters which would be set at their limiting value in Limiting Value Approach (LVA) calculation. Single run of LVA calculation generated 27 PCT data according to the various combinations of fuel parameters and these data provided input to response surface generation. The probability distribution function was generated from Monte Carlo sampling of a response surface and the upper 95$^{th}$ percentile PCT was determined. Break spectrum analysis was also made to determine the critical break size. The results show that sufficient LOCA margin can be obtained for the demonstration NPP.

  • PDF

INTEGRAL BEHAVIOR OF THE ATLAS FACILITY FOR A 3-INCH SMALL BREAK LOSS OF COOLANT ACCIDENT

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Euh, Dong-Jin;Kim, Yeon-Sik;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.199-212
    • /
    • 2008
  • A small-break loss of coolant accident (SB-LOCA) test with a break size equivalent to a 3-inch cold leg break of the APR1400 was carried out as the first transient integral effect test using the ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation). This was the first integral effect test to investigate the integral performance of the test facility and to verify its simulation capability for one of the design-basis accidents. Reasonably good thermal hydraulic data was obtained so that an integral performance of the fluid sub-systems was identified and control performance of the ATLAS was confirmed under real thermal hydraulic conditions. Based on the measured data, a post-test calculation was carried out using the best-estimate thermal hydraulic safety analysis code, MARS 3.1, and the similarity between the expected and actual data was investigated. On the whole, the post-test calculation reasonably predicts the major thermal hydraulic parameters measured during the SB-LOCA test. The obtained data will be used to enhance the simulation capability of the ATLAS and to improve an input model of the ATLAS for simulation of other target scenarios.

Effect of Different Day Length on the Production of Onion (Allium cepa L.) Set (양파 자구생산에 미치는 일장처리 효과)

  • Ahn, Su Ran;Suh, Jun Kyu
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.43-47
    • /
    • 2013
  • This study was conducted to develop the most effective method in promoting onion set in cultivars 'Josaengsseondebol' and 'Daeji' for all year-round production. This was done by extending the day length for 41 days. For both cultivars, the period to reach the maximum number of leaves developed was shortened as the exposure to day length increased. Between the two cultivars, 'Josaengsseondebol' reaches its maximum leaf formation for a shorter duration compared with 'Daeji'. In effect to bulb size, cultivar 'Josaengsseondebol' having a night break of 1, 2, and 16 hours light condition had better bulb enlargement compared with the non-treated bulbs. In the case of cultivar 'Daeji', only bulbs exposed to a night break of 2 and 16 hours light condition had better bulb enlargement. The percentage of marketable set yield in cultivar 'Josaengsseondebol' having a night break of 1 hr, 2 hrs, 16 hrs light condition, and control or untreated bulbs were 84%, 92%, 90%, and 6% respectively. In the case of cultivar 'Daeji', treated with a night break of 1 hr, 2 hrs, 16 hrs light condition, and untreated bulbs had a percentage marketable set yield of 7%, 55%, 64%, and 0% respectively. Based on these results, it is therefore concluded that night break treatment is considered to be effective method in promoting off-season onion set cultivation in cultivar 'Josaengsseondebol'.

Effects of Different Fluid Properties on Velocity and Size of Droplets from Pressure-Swirl Nozzles (유체의 물성치 변화가 압력스월노즐 분무의 속도와 입경에 미치는 영향)

  • Choi, Youn-Chul;Son, Jong-Won;Cha, Keun-Jong;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.909-914
    • /
    • 2001
  • Fluid properties which are most commonly used to evaluate spray atomization characteristics, are important because they affect velocity and size distribution of droplets. The purpose of this study was to incorporate the significant characteristics in atomization process of industrial etching spray and how each of them affects the design of precise pressure-swirl nozzles. The experiment was carried out with different viscosity and density of fluid. The macro characteristics of liquid spray, such as the spray angle and shape were captured by PMAS and the micro characteristics of liquid spray, such as droplet size and velocity were obtained by PDA. The mean velocity and SMD of droplets were measured along axial and radial direction. It was found that the higher viscosity and density resulted in the larger SMD and the lower mean velocity of droplets.

  • PDF

Morphology and Physical Properties of ABS/NBR Blends: The Effect of AN Content in NBR

  • Lee, Kwan-Hee;Ahn, Sang-Jun;Kim, Byung-Kyu;Jeong, Han-Mo
    • Macromolecular Research
    • /
    • v.9 no.1
    • /
    • pp.30-36
    • /
    • 2001
  • Polybutadiene latex grafted (g-PB) in g-PB/SAN blends, i.e., acrylonitrile-butadiene-styrene terpolymer (ABS) were partially replaced by acrylonitrile-butadiene copolymer (NBR) with various acrylonitrile (AN) contents. Changes in morphology, physical and rheological properties were examined. The dispersed size of NBR was decreased as the miscibility with matrix SAM, was increased by increasing AN content in NBR upto 50 wt%. Impact strength was enhanced about two-fold due to the NBR dispersed with a slight larger size than the original g-PB. Gloss was effectively reduced as the particle size of NBR was increased. Tensile yield strength was decreased, and elongation at break or yield behavior at low shear rate were increased as g-PB was partially replaced by NBR having AN content less that 40 wt%.

  • PDF

FEM Analysis of Effect of Shot Peening for Stress Corrosion Cracking at Welded Part (용접부 응력부식균열 방지를 위한 쇼트피닝 효과의 유한요소 해석)

  • NAM KI-Woo;AHN SEOK-WHAN
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.239-241
    • /
    • 2004
  • Stress intensity factor of semi-circular crack front was calculated by FEM, and also allowable crack size which doesn‘t break out the fracture by SCC in residual stress field of STS materials. Allowable crack size was increased with compressive residual stress provided by shot peening on material surface, and with magnitude of compressive residual stress for depth direction.

  • PDF

A Study on Influences of Crack Morphology Variables (균열형상변수의 영향 고찰)

  • Park, Won-Bae;Lee, Young-Shin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.324-329
    • /
    • 2004
  • In this study, an application of crack morphology variables in the Leak-Before-Break(LBB) evaluation for nuclear piping systems is investigated, including influences on the leakage crack size and crack instability loads. The crack surface roughness and the number of flow turns as a function of the crack opening displacement are applied to LBB evaluations for KSNP pressurizer surge line, for which fatigue and stress corrosion cracking are considered as failure mechanisms. As a result, there would be a significant impact on safety margins to acceptance criteria for the surge line if crack morphology variables are applied additionally to the current regulatory guide without re-analyses for justification of safety factors being applied on the leakage crack size and piping loads for evaluations.

  • PDF

Growth and Flowering of Orostachys japonicus A. Berger Affected by Transplanted Seedling Size (정식시 유묘 크기에 따른 바위솔의 생장과 개화)

  • Jeon, Seung-Ho;Hong, Dong-Oh;Lee, Chang-Woo;Kim, Hong-Young;Shin, Sung-Cheol;Kang, Jin-Ho
    • Korean Journal of Medicinal Crop Science
    • /
    • v.14 no.3
    • /
    • pp.153-157
    • /
    • 2006
  • Floret flowering of Orostachys japonicus, a monocarpic and short day plant, should be controlled to continue cultivating. The study was done to examine the effect of transplanted seedling size (large, 18 leaves; medium, 13 leaves; small, 8 leaves) on growth, morphological characters, and flowering. Night-break treatment of 2 hours at midnight were done on August 25 and afterward samples were taken every 2 weeks. Growth, morphological and flowering related characters were measured from each sample. With larger seedling transplanted, plant height, inflorescence length, number of leaves including bracts and stem diameter were increased. Leaves and bracts, stem, root, shoot and total dry weights were increased as transplanted seedlings became larger. Although formed florets were inclined with larger transplanted seedling, they were not flowered because of the night-break treatment, meaning that the larger transplanted seedlings, the more economic yield.