• Title/Summary/Keyword: Break size

Search Result 245, Processing Time 0.024 seconds

Luminosity function and size distribution of HII regions in M51

  • Lee, Jong-Hwan;Lee, Myung-Gyoon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.54.2-54.2
    • /
    • 2011
  • We present a study of HII regions in M51 using HST/ACS images taken as part of the Hubble Heritage Program. We found about 19,600 HII regions in M51 with $H_{\alpha}$ luminosity in the range of $L=10^{35.5}-10^{39.0}\;erg\;s^{-1}$. The $H_{\alpha}$ luminosity function of HII regions (HII LF) in M51 is well represented by a double power law with its index ${\alpha}=-2.25{\pm}0.02$ for the bright part and ${\alpha}=-1.42{\pm}0.01$ for the faint part, separated at a break point $L=10^{37.1}\;erg\;s^{-1}$. Comparison with simulated HII LFs suggests that this break is caused by the transition of HII region ionizing sources, from low-mass clusters (including several OB stars) to more massive clusters (including several tens of OB stars). The HII LFs with L < $10^{37.1}\;erg\;s^{-1}$ are found to have different slopes for different parts in M51: the HII LF for the interarm region is steeper than those for the arm and the nuclear regions. This observed difference in HII LFs can be explained by evolutionary effects: HII regions in the interarm region are relatively older than those in the other parts of M51. The size distribution of the HII regions is fitted by a double power law with a break at D = 30 pc. The power law index for the small HII regions with 15 pc < D < 30 pc is ${\alpha}=-1.78{\pm}0.04$, whereas ${\alpha}=-5.04{\pm}0.08$ for the large HII region with 30 pc < D < 110 pc. The power law indices of the size distribution are related with those of HII LF, and the relation between the luminosities and sizes of HII regions is fitted well by $L{\propto}D^{3.04{\pm}}$.

  • PDF

Factors influencing Video Display Terminal Syndrome in Clinical Nurses (임상간호사의 영상표시단말기 증후군 및 영향요인)

  • Kwon, Yunhee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.22 no.4
    • /
    • pp.485-494
    • /
    • 2016
  • Purpose: The present research is a descriptive study aimed at understanding clinical nurses' Video display terminal (VDT) syndrome and identifying the factors that affect their VDT syndrome. Methods: Data were collected from 239 clinical nurses working in two metropolitan cities. Research tools included subject's VDT syndrome assessing musculoskeletal, ophthalmic, dermal, psychiatric, and whole body syndromes. The data were analyzed using frequency analysis, average and standard deviation, t-test, One-way ANOVA, and multiple regression analysis with the SPSS/WIN 20.0 program. Results: The subjects' VDT syndrome score was 1.34 out of 5. There were significant differences in participating subjects' VDT syndrome, hospital's size, working unit, health status, diagnosis of illness, having an Order Communication System (OCS), having an Electronic Medical Record (EMR) System, continuous VDT working for more than one hour, break time during VDT use, VDT use time, comfort of the chair, adjustability of the height of the chair, size of the VDT's desk, distance between the monitor and the user's eyes, resolution of the monitor, and frequency of eye exercise during VDT use. According to the research, influencing factors on VDT syndrome in clinical nurses included size of the VDT's desk, frequency of eye exercise during VDT use, having an EMR system, break time during VDT use, diagnosis illness, and having an OCS' system. Conclusion: The findings from this study can be used as a basis for future VDT syndrome prevention education and programs for clinical nurses.

Is the Fama French Three-Factor Model Relevant? Evidence from Islamic Unit Trust Funds

  • Shaharuddin, Shahrin Saaid;Lau, Wee-Yeap;Ahmad, Rubi
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.5 no.4
    • /
    • pp.21-34
    • /
    • 2018
  • The study tests the Fama and French three-factor model by using the newly created Islamic equity style indices. Based on a dataset from May 2006 to April 2011, the three-factor model is tested based on returns of Islamic unit trust funds using the Generalized Method of Moments (GMM) methodology. The sample period is also divided between periods before and after the Global Financial Crisis in August 2008 to test for robustness, and the Bai and Perron (2003) multiple structural break test was used to determine the structural break in the series. The analysis shows that the Fama and French model is valid for Islamic unit trust funds before and after the collapse of Lehman Brothers. The result further indicates the reversal of size effect. As for trading strategies, value funds outperform growth funds by annualized 3.13 percent for the full period. During pre-crisis period, value funds perform better than growth funds while in post-crisis, size factor yields better return than other strategies. As policy suggestion, fund managers need to be aware of the reversal of size effect, and they need to ensure a more transparent stock selection process so that investors can make an informed decision in their asset allocation.

Utilization of Body Computed Tomography Scanners in Non-Metropolitan Area (비수도권(非首都圈) 지역(地域)에서의 전신용(全身用) X선(線) CT의 이용(利用))

  • Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.29-45
    • /
    • 1985
  • Computed Tomography Scanner (CT) is highly expensive in operation as well as purchasing. That reason may cause not only to increase the burden of patients but also to waste the capital resources leading to financial difficulties. However the numbers of CT installed throughout the country is increasing, because of efficiency in medical care, patient's concern, competitions among the hospitals within the same area. In the non-Metropolitan area the scanners were expected to be less utilized and less profitable. Nine hospitals equipped with the CT were studied on the utilization of that equipment during the period from November 1984 to February 1985 in non-Metropolitan area and break-even point in one hospital was analyzed for estimating profitabilities. The results were as follows ; 1. Among those nine hospitals, four hospitals had less than 400 beds, which is one of the restrictive minimum standards on the installation of Whole-body Computed Tomography Scanner. 2. The operating time during the normal operation period was longer than those of any other studies, but the accumulated down time was also longer than those of any other studies. The average number of scanning per week for each CT was 45, while the estimated number of for the break-even point was 56.7 cases. 3. When the downtime was excluded in calculating the average operation would be much closer to the cases for the break-even point. Therefore the break-down of the equipment was to be a main cause of the low profitability. 4. The average scanning rate for head area was 33.6%, however three of the nine hospitals showed about 20%. 5. If scanning ratio for the body parts excepting head was increased, the number of scanning for the break-even point would be diminished. 6. The small size hospital especially located near the Metropolitan area showed largest loss in the CT operation. In purchasing the highly expensive equipments in hospitals, demand should be taken into account and planning is recommended.

  • PDF

Dielectric Breakdown and Electric Stress Distribution in Ferroelectrics (강유전체에서의 전계분포 및 절연파괴)

  • 신병철;김호기
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.4
    • /
    • pp.392-396
    • /
    • 1987
  • Pure barium titanate was sintered at $1340^{\circ}C$ for 2, 4, 8, 16 hr to control their grain size. The measurements of breakdown strength and partial discharge characteristics were performed under rising AC voltage(60Hz). With increase of sintering time, the average grain size was increased and breakdown strength was slightly decreased. Partial discharge in pores was observed under high voltage, and a model of dielectric break down in barium titanate ceramics is proposed.

  • PDF

Effect of Compatibilizers on the Mechanical Properties of Waste Polypropylene/Waste Ground Rubber Tire Composites (상용화제의 첨가에 따른 재생 폴리프로필렌/폐타이어 분말 복합체의 기계적 특성 분석)

  • Park, Ki-Hun;Kim, Dong-Hak;Jung, Jong-Ki;Kim, Seong-Gil;Bang, Daesuk;Oh, Myung-Hoon;Kim, Bong-Suk
    • Resources Recycling
    • /
    • v.23 no.1
    • /
    • pp.70-79
    • /
    • 2014
  • In this study, waste polypropylene and waste ground rubber tire(WGRT) composites were prepared by using a modular intermeshing co-rotating twin screw extruder. The effect of three main factors such as WGRT contents, particle size, compatibilizers on the properties of waste PP/WGRT composites was extensively investigated. Tensile strength of the composites was decreased with an increase in WGRT contents, whereas elongation at break and impact strength were increased. The tensile strength, elongation at break and impact strength of the composites with the smaller size of the WGRT were more enhanced. Addition of PP-g-MA into waste PP/WGRT composites exhibited better tensile strength. However, elongation at break and impact strength were slightly decreased with increasing of PP-g-MA. On the other hand, tensile strength, impact strength and elongation at break of the composites were increased by adding the EPDM-g-MA and SEBS-g-MA. Especially, elongation at break was significantly increased compared to the composite with PP-g-MA.

PREDICTION OF SEVERE ACCIDENT OCCURRENCE TIME USING SUPPORT VECTOR MACHINES

  • KIM, SEUNG GEUN;NO, YOUNG GYU;SEONG, POONG HYUN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.74-84
    • /
    • 2015
  • If a transient occurs in a nuclear power plant (NPP), operators will try to protect the NPP by estimating the kind of abnormality and mitigating it based on recommended procedures. Similarly, operators take actions based on severe accident management guidelines when there is the possibility of a severe accident occurrence in an NPP. In any such situation, information about the occurrence time of severe accident-related events can be very important to operators to set up severe accident management strategies. Therefore, support systems that can quickly provide this kind of information will be very useful when operators try to manage severe accidents. In this research, the occurrence times of several events that could happen during a severe accident were predicted using support vector machines with short time variations of plant status variables inputs. For the preliminary step, the break location and size of a loss of coolant accident (LOCA) were identified. Training and testing data sets were obtained using the MAAP5 code. The results show that the proposed algorithm can correctly classify the break location of the LOCA and can estimate the break size of the LOCA very accurately. In addition, the occurrence times of severe accident major events were predicted under various severe accident paths, with reasonable error. With these results, it is expected that it will be possible to apply the proposed algorithm to real NPPs because the algorithm uses only the early phase data after the reactor SCRAM, which can be obtained accurately for accident simulations.

Loss of Coolant Accident Analysis During Shutdown Operation of YGN Units 3/4

  • Bang, Young-Seok;Kim, Kap;Seul, Kwang-Won;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.17-28
    • /
    • 1999
  • A thermal-hydraulic analysis is conducted on the loss-of-coolant-accident (LOCA) during shutdown operation of YGN Units 3/4. Based on the review of plant-specific characteristics of YGN Units 3/4 in design and operation, a set of analysis cases is determined, and predicted by the RELAP5/MOD3.2 code during LOCA in the hot-standby mode. The evaluated thermal-hydraulic phenomena are blowdown, break flow, inventory distribution, natural circulation, and core thermal response. The difference in thermal-hydraulic behavior of LOCA at shutolown condition from that of LOCA at full power is identified as depressurization rate, the delay in peak natural circulation timing and the loop seal clearing (LSC) timing. In addition, the effect of high pressure safety injection (HPSI) on plant response is also evaluated. The break spectrum analysis shows that the critical break size can be between 1% to 2% of cold leg area, and that the available operator action time for the Sl actuation and the margin in the peak clad temperature (PCT) could be reduced when considering uncertainties of the present RELAP5 calculation.

  • PDF

Uncertainty analysis of ROSA/LSTF test by RELAP5 code and PKL counterpart test concerning PWR hot leg break LOCAs

  • Takeda, Takeshi;Ohtsu, Iwao
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.829-841
    • /
    • 2018
  • An experiment was conducted for the OECD/NEA ROSA-2 Project using the large-scale test facility (LSTF), which simulated a 17% hot leg intermediate-break loss-of-coolant accident in a pressurized water reactor (PWR). In the LSTF test, core uncovery started simultaneously with liquid level drop in crossover leg downflow-side before loop seal clearing, and water remaining occurred on the upper core plate in the upper plenum. Results of the uncertainty analysis with RELAP5/MOD3.3 code clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges. For studying the scaling problems to extrapolate thermal-hydraulic phenomena observed in scaled-down facilities, an experiment was performed for the OECD/NEA PKL-3 Project with the Primarkreislaufe Versuchsanlage (PKL), as a counterpart to a previous LSTF test. The LSTF test simulated a PWR 1% hot leg small-break loss-of-coolant accident with steam generator secondary-side depressurization as an accident management measure and nitrogen gas inflow. Some discrepancies appeared between the LSTF and PKL test results for the primary pressure, the core collapsed liquid level, and the cladding surface temperature probably due to effects of differences between the LSTF and the PKL in configuration, geometry, and volumetric size.

A Financial Model to Select the Size of Theme Park (주제공원의 규모결정을 위한 손익모형 I -용인자연농원을 사례로-)

  • 이양주;유병림
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.24 no.1
    • /
    • pp.55-64
    • /
    • 1996
  • The size of leisure space has been determined on the basis of the annual and peak day's number of visitor, turnover rate, and size per visitor. But the past models have no theoretical base and practical errors on the many cases. So, this study was carried out to build and test a new theoretical model for selecting a optimal size of theme park. The basic concept of the model building is the break-even point analysis of cost-volume-profit relation. That is, Gain-Loss of theme park is determined by marginal profit and fixed cost by size. YongIn Farmland was selected as a model test case.

  • PDF