• Title/Summary/Keyword: Break load

Search Result 188, Processing Time 0.022 seconds

A study on the Morphological Changes of Hair after Treatment with Neutral Oxidative Dyeing Agent (중명도(中明渡) 산화염모제 처치 후 모발의 형태학적 변화 연구)

  • Park, Jang-Soon
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.7
    • /
    • pp.289-295
    • /
    • 2020
  • As the importance of the beauty to pursue beauty comes to the fore, the market size of hairdressing industry including hair dyeing is getting bigger. In case of continuously applying an oxidative dyeing agent commonly used in hair salons, as hair damage is inevitable, we investigated morphological changes of hair treated with a neutral oxidative dyeing agent. In the experiment results, Between the control and the 6N-7N experimental groups, there was a significant difference in Max. modulus and Tangential modulus according to Max. load, Max. stress, Max. elongation, Break load, Break stress, Break elongation, and strain section. There were the highest values in Max. load, Max. stress, Max. elongation, Break load, Break stress and Break elongation in the control group, and there was no tendency to decrease significantly according to the treatment of the experimental group. Max. modulus and Tangential modulus according to the strain evaluation section did not show a tendency to increase or decrease constantly, although there was a difference between the control and experimental groups. This study attempts to provide basic data for the development of oxidative dyeing agent that minimizes hair damage and to establish the foundation for understanding the correlation between hair designers' oxidative dyeing agent and hair health.

Dynamic load concentration caused by a break in a Lamina with viscoelastic matrix

  • Reza, Arash;Sedighi, Hamid M.;Soleimani, Mahdi
    • Steel and Composite Structures
    • /
    • v.18 no.6
    • /
    • pp.1465-1478
    • /
    • 2015
  • The effect of cutting off fibers on transient load in a polymeric matrix composite lamina was studied in this paper. The behavior of fibers was considered to be linear elastic and the matrix behavior was considered to be linear viscoelastic. To model the viscoelastic behavior of matrix, a three parameter solid model was employed. To conduct this research, finite difference method was used. The governing equations were obtained using Shear-lag theory and were solved using boundary and initial conditions before and after the development of break. Using finite difference method, the governing integro-differential equations were developed and normal stress in the fibers is obtained. Particular attention is paid the dynamic overshoot resulting when the fibers are suddenly broken. Results show that considering viscoelastic properties of matrix causes a decrease in dynamic load concentration factor and an increase in static load concentration factor. Also with increases the number of broken fibers, trend of increasing load concentration factor decreases gradually. Furthermore, the overshoot of load in fibers adjacent to the break in a polymeric matrix with high transient time is lower than a matrix with lower transient time, but the load concentration factor in the matrix with high transient time is lower.

Reliability testing equipment for SF_6 gas load break switch (가스절연부하개폐기의 신뢰성 평가장비)

  • Heo J.C.;Park S.J.;Kang Y.S.;Koh H.S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.560-562
    • /
    • 2004
  • $SF_6$ gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, most of power companies adopted the $SF_6$ gas-type load break switch for increasing the reliability of distribution network by its superior durability against external environmental condition, in substitution for air-type and oil-type switches. But, it is important to establish the general estimation process for the testing and estimation for long-term reliability Accordingly, the national standard(RS C0031) was made for the reliability assessment of $SF_6$ gas load break switch and the testing facilities were also set in KERI(Korea Electrotechlology Research Institute). This paper presents the requirements of RS C0031 for reliability assessment of $SF_6$ gas load break switch and synopsis of the accelerated life testing facilities for $SF_6$ gas load break switch.

  • PDF

Accelerated life test of SF_6 gas load break switch for overhead line (가공용 가스절연부하개폐기 가속수명시험)

  • Park Seung Jae;Heo Jong Chul;Kim Maeng Hyun;Koh Heui Seog
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.551-553
    • /
    • 2004
  • SF_6 gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, with these trends, SF_6 load break switches have rapidly substituted for the air or oil-type load break switches, in order to get higher reliability. And, the national standard was made for reliability assessment of SF_6 gas load break switch and testing facilities was also set in KERI(Korea Electrotechnology Research Institute ). This paper introduces the synopsis for the reliability assessment requirements specified in the standard and the assessment results.

  • PDF

The Effect of Residual Stresses on Surface Failure and Wear (잔류응력의 표면파손과 마멸에 대한 영향)

  • Lee, Yeong-Je;Kim, Jin-Uk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.4
    • /
    • pp.677-682
    • /
    • 2002
  • Break-in is an intentional treatment to enhance the performance life of machinery parts and to maintain static friction behavior. Most studies on break-in have concerned only about surface conditions such as roughness or film formation. But the exact mechanism of break-in has not been found yet. Friction, scuffing behavior and wear of AISI 1045 were studied in relation to break-in and residual stress. The cylinder-on-disk type tribometer was used with the line-contact geometry. Scuffing tests were carried out using a constant load of 730N. In the break-in procedure the step load was applied from 100N to 200N. In this experiment, it was found that the break-in helps compressive residual stress to be formed well enough to enhance the scuffing life during the scuffing test. Specimens that had high compressive residual stress induced by shot-peening show better wear resistance than those were not shot-peened. Results of scuffing test, break-in procedure and wear amount in relation to residual stress have been discussed.

The Formation of Residual Stresses and the Surface Fracture by the Break-in Process (길들이기에 의한 잔류응력의 형성과 표면파괴)

  • 김진욱;이영제
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.159-165
    • /
    • 2000
  • In this paper the residual stresses on lubricated sliding surfaces were measured during break-in procedure and up to scuffing by the X-ray diffraction method. The cylinder-on-disk type tribometer was used with the line-contact geometry. Scuffing tests were done using a constant load. In the break-in procedure the loads were increased from very low values in several steps. It was found that the sliding surfaces with break-in represented relatively higher values of residual compressive stresses than those without break-in. The residual stresses below the surfaces showed the small amount of stress increases. The results of scuffing tests with and without break-in showed the same trends as break-in tests did. However, in case of tests with break-in procedure the stresses below the surfaces showed very large increases in the residual compressive stresses. From the tests of break-in and scuffing, it was found that the increases in scuffing lives were related with the increases of residual stresses on the lubricated sliding surfaces with break-in.

  • PDF

The Changes of Residual Stresses on Sliding Surfaces during Break-in and Scuffing (길들이기 과정과 표면파괴 과정에서의 잔류응력 변화)

  • 김진욱;이영제
    • Tribology and Lubricants
    • /
    • v.16 no.3
    • /
    • pp.182-187
    • /
    • 2000
  • In this paper the residual stresses on lubricated sliding surfaces were measured during break-in procedure and up to scuffing by the X-ray diffraction method. The cylinder-on-disk type tribometer was used with the line-contact geometry. Scuffing tests were done using a constant load. In the break-in procedure the loads were increased from very low values in several steps. It was found that the sliding surfaces with break-in represented relatively higher values of residual compressive stresser than those without break-in. The residual stresses below the surfaces showed the small amount of stress increases. The results of scuffing tests with and without break-in showed the same trends as break-in tests did. However, in case of tests with break-in procedure the stresses below the surfaces showed very large increases in the residual compressive stresses. From the tests of break-in and scuffing, it was found that the increases in scuffing lives were related with the increases of residual stresses on the lubricated sliding surfaces with break-in.

Reliability for SF6 gas load break switch of distribution system (배전선로용 가스절연부하개폐기의 신뢰성 향상책)

  • Park, Seung-Jae;Heo, Jong-Chul;Shin, Young-June;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.452-454
    • /
    • 2003
  • $SF_6$ gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, most of power companies adopted the $SF_6$ gas-type load break switch for increasing the reliability of distribution network by its superior durability against external environmental condition, in substitution for air-type and oil-type switches. But, it is important to establish the general estimation process for the testing and estimation for long-term reliability. Accordingly, this paper presents the reliability testing method for $SF_6$ gas load break switch which is based on the analysis of the failure mode and the statistics.

  • PDF

Study on the Synthesis of Wool-blending Fiber Bundle and New Signs of the Curve

  • Ren Yonghua;Yu Jianyong
    • Fibers and Polymers
    • /
    • v.6 no.4
    • /
    • pp.339-342
    • /
    • 2005
  • In this paper, a hand-operating method (tiled test method) of the wool-blending sample is made out, and make use of the method, the test of wool-blending bundle in different blending ratio is accomplished. According to the test data, the synthesis method of the stretch curve is worked out and the synthesis software for the typical stretch curve of wool-blending bundle is designed. Through laboratory hand-operating method, the blending fasciculus applying to fiber bundle test can be obtained in a short time. Calculation for sampling is accomplished in the article. We bring up 9 new signs to describe the characteristics of the curve behind peak for the first time: elongation behind peak (HE), elongation percentage behind peak (HEP), relative elongation rate behind peak (RHE), total break work $(W_a)$, break work behind peak (HW), break work coefficient behind peak (HWC), elongation percentage of half-load behind peak (HEL), load percentage of half-elongation behind peak (HLE), break efficiency behind peak (HEC).

Reological Studies on Cocoon Filament II. Changes of strength and elongation at breaking related to the stretching speed and swelling degree (견사의 탄성적성질에 관한 연구 II. 인장속도 및 팽윤에 따른 파괴강신도의 변화)

  • 남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.14 no.2
    • /
    • pp.105-112
    • /
    • 1972
  • The effects of the stretching speed and the swelling degree of cocoon filaments on load-elongation curve were tested by tensilon with special attachments. The values of breaking strength, elongation at break and initial tensile strength obtained from load elongation curves are summarized as follows; 1. The breaking strength of the swollen cocoon filament appeared to increase at the high stretching speed, while elongation at break decreased. 2. Load-elongation curve became crinkled at the low speed of stretching. It suggests that both slip and break of the macrofibrils may occur in swelling of cocoon bave. 3. Breaking strength appeared to considerably decrease and elongation at break not to increase in swelling test at 9$0^{\circ}C$ for 60 min. 4. The initial tensile strength was influenced by the stretching speed and swelling degree of cocoon filaments.

  • PDF