• Title/Summary/Keyword: Break

Search Result 3,586, Processing Time 0.026 seconds

Statistical Analysis for Path Break-Up Time of Mobile Wireless Networks (이동 무선망의 경로 붕괴시간에 대한 통계적 분석)

  • Ahn, Hong-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.5
    • /
    • pp.113-118
    • /
    • 2015
  • Mobile wireless networks have received a lot of attention as a future wireless network due to its rapid deployment without communication infrastructure. In these networks communication path between two arbitrary nodes break down because some links in the path are beyond transmission range($r_0$) due to the mobility of the nodes. The set of total path break down time(${\bigcup}T_i$), which is the union of path break down time of every node pair, can be a good measure of the connectivity of the dynamic mobile wireless network. In this paper we show that the distribution of the total path break down time can be approximated as a exponential probability density function and confirms it through experimental data. Statistical knowledge of break down time enables quantitative prediction of delay, packet loss between two nodes, thus provides confidence in the simulation results of mobile wireless networks.

The Break Line Fit Improvement of the Women's Tailored Collar Vest (여성용 테일러드 칼라 베스트 브레이크라인 맞음새 연구)

  • Kim, Young Hee;Park, Gin Ah
    • Journal of the Korean Society of Costume
    • /
    • v.66 no.4
    • /
    • pp.146-165
    • /
    • 2016
  • The aim of the study is to propose ways to improve the break line fit of women's tailored collar vests by modifying the patternmaking process. The study explored the fit effects of experimental vests with a focus on 3 different breast sizes, A, B, and C cups. Women in the ages between 20 and 24 in South Korea were targeted. In order to carry out the objective, the study implemented separate girth measurements for the front and the back of the tailored collar vests, and also allocated different dart amounts on the lapel through the break line according to the different breast cup sizes. The study adopted a 5-point rating scale to perform evaluation of the different fit effects caused by the varying dart amounts given on the experimental vests' break lines. This evaluation was carried out by apparel pattern experts. The results derived from the study were as follows: first, the implementation of separate girth measurements provided originality to the study, as the application of different measurements for the waist back length and the neck shoulder point-to-breast point-to-waist line led to the front panels of the experimental vests having varying slack amounts. Second, break line dart was applied in three different amounts, 0.5, 1.0, and 1.5cm respectively according to A, B and C breast sizes, and as the dart amount increased, extra ease on the break lines was reduced. The dart was applied on the edge lines of the lapel and it was applied from a point which was 6cm above the breast point to the end of the princess line for all the breast cup sizes.

Vibration Pattern Prediction through The Analysis on the Break-up Mode and the Heat Transfer Relationship of Slim Speaker Diaphragm (슬림 스피커 진동판의 분할진동 모드와 열전달 관계 분석을 통한 진동 패턴 예측)

  • Kim, Hyun-Kab;Kim, Hiesik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.109-115
    • /
    • 2016
  • In this paper, In this paper, we use two methods to compare the slim speakers. That way, the diaphragm scan using laser and diaphragm photographed using a thermal imaging camera. Slim speaker has the structure of a flat plate type. Break-up mode by this characteristic is displayed in a larger size. Further, since the installation space is narrow, it has limited moving coil cooling. As a result, the break-up mode slim speakers, a significant impact on quality. In this study, try to connect the break-up mode of the diaphragm, the heat transfer mode of the diaphragm. Experiment for comparison, a two-step. The first step is to measure the divided vibration through the vibration plate scan. The second step measures the diaphragm photographed using a thermal imaging camera. Then, compare the results of both of the same frequency. Thus, comparing the heat transfer pattern and the pattern of break-up mode. Tend to be analysis of break-up mode from the pattern comparison, and document for the optimum design.

It is Time to Have Rest: How do Break Types Affect Muscular Activity and Perceived Discomfort During Prolonged Sitting Work

  • Ding, Yi;Cao, Yaqin;Duffy, Vincent G.;Zhang, Xuefeng
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.207-214
    • /
    • 2020
  • Background: Prolonged sitting at work can lead to adverse health outcomes. The health risk of office workers is an increasing concern for the society and industry, with prolonged sitting work becoming more prevalent. Objective: This study aimed to explore the variation in muscle activities during prolonged sitting work and found out when and how to take a break to mitigate the risk of muscle symptoms. Methods: A preliminary survey was conducted to find out the prevalence of muscle discomfort in sedentary work. Firstly, a 2-h sedentary computer work was designed based on the preliminary study to investigate the variation in muscle activities. Twenty-four participants took part in the electromyography (EMG) measurement study. The EMG variations in the trapezius muscle and latissimus dorsi were investigated. Then the intervention time was determined based on the EMG measurement study. Secondly, 48 participants were divided into six groups to compare the effectiveness of every break type (passive break, active break of changing their posture, and stand and stretch their body with 5 or 10 mins). Finally, data consisting of EMG amplitudes and spectra and subjective assessment of discomfort were analyzed. Results: In the EMG experiment, results from the joint analysis of the spectral and amplitude method showed muscle fatigue after about 40 mins of sedentary work. In the intervention experiment, the results showed that standing and stretching for 5 mins was the most effective break type, and this type of break could keep the muscles' state at a recovery level for about 30-45 mins. Conclusions: This study offers the possibility of being applied to office workers and provides preliminary data support and theoretical exploration for a follow-up early muscle fatigue detection system.

Decay Beat Removal and Operator's Intervention During A Very Small L()CA (매우 작은 규모의 냉각재 상실 사고 동안 잔열 제거와 운전자의 개입)

  • Hee Cheon No
    • Nuclear Engineering and Technology
    • /
    • v.16 no.1
    • /
    • pp.11-17
    • /
    • 1984
  • Sample calculations were done for KORI-1 to develop a better understanding of what happens after very small LOCA ($\leq$0.05 ft$^2$). For a water-side break with the break size larger than 0.006 ft$^2$, fluid-loss through break exceeds the makeup. If the break size is larger than 0.008ft$^2$, decay heat can be completely removed through break. Based on these results, it was concluded that KORI-1 is fairly safe for the whole spectrum of sizes in very small LOCA. However, for the reactor with 900 MWe or 1200 MWe, a certain spectrum of sizes in very small LOCA should be carefully considered. In the accident sequence the transition from natural circulation to pool boiling or from pool boiling to natural circulation may be troublesome to the operator or in the safety analysis. Operator's intervention was discussed; primary pump shutoff, HPI pump shutoff, break isolation, and opening relief valve. It was proved that continuous operation of HPI pumps after shutdown will not threaten the integrity of the primary system.

  • PDF

Evaluation of DNA Damage Using Microwave Dielectric Absorption Spectroscopy

  • Hirayama, Makoto;Matuo, Youichirou;Sunagawa, Takeyoshi;Izumi, Yoshinobu
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.339-343
    • /
    • 2016
  • Background: Evaluation of deoxyribonucleic acid (DNA)-strand break is important to elucidate the biological effect of ionizing radiations. The conventional methods for DNA-strand break evaluation have been achieved by Agarose gel electrophoresis and others using an electrical property of DNAs. Such kinds of DNA-strand break evaluation systems can estimate DNA-strand break, according to a molecular weight of DNAs. However, the conventional method needs pretreatment of the sample and a relatively long period for analysis. They do not have enough sensitivity to detect the strand break products in the low-dose region. Materials and Methods: The sample is water, methanol and plasmid DNA solution. The plasmid DNA pUC118 was multiplied by using Escherichia coli JM109 competent cells. The resonance frequency and Q-value were measured by means of microwave dielectric absorption spectroscopy. When a sample is located at a center of the electric field, resonance curve of the frequency that existed as a standing wave is disturbed. As a result, the perturbation effect to perform a resonance with different frequency is adopted. Results and Discussion: The resonance frequency shifted to higher frequency with an increase in a concentration of methanol as the model of the biological material, and the Q-value decreased. The absorption peak in microwave power spectrum of the double-strand break plasmid DNA shifted from the non-damaged plasmid DNA. Moreover, the sharpness of absorption peak changed resulting in change in Q-value. We confirmed that a resonance frequency shifted to higher frequency with an increase in concentration of the plasmid DNA. Conclusion: We developed a new technique for an evaluation of DNA damage. In this paper, we report the evaluation method of DNA damage using microwave dielectric absorption spectroscopy.

Modeling Downstream Flood Damage Prediction Followed by Dam-Break of Small Agricultural Reservoir (농업용 소규모 저수지의 붕괴에 따른 하류부 피해예측 모델링)

  • Park, Jong-Yoon;Joh, Hyung-Kyung;Jung, In-Kyun;Jung, Kwan-Soo;Lee, Joo-Heon;Kang, Bu-Sik;Yoon, Chang-Jin;Kim, Seong-Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.6
    • /
    • pp.63-73
    • /
    • 2010
  • This study is to develop a downstream flood damage prediction model for efficient confrontation in case of extreme and flash flood by future probable small agricultural dam break situation. For a Changri reservoir (0.419 million $m^3$) located in Yongin city of Gyeonggi province, a dam break scenario was prepared. With the probable maximum flood (PMF) condition calculated from the probable maximum precipitation (PMP), the flood condition by dam break was generated by using the HEC-HMS (Hydrologic Engineering Center - Hydrologic Modeling System) model. The flood propagation to the 1.12 km section of Hwagok downstream was simulated using HEC-RAS (Hydrologic Engineering Center - River Analysis System) model. The flood damaged areas were generated by overtopping from the levees and the boundaries were extracted for flood damage prediction, and the degree of flood damage was evaluated using IDEM (Inundation Damage Estimation Method) by modifying MD-FDA (Multi-Dimensional Flood Damage Analysis) and regression analysis simple method. The result of flood analysis by dam-break was predicted to occurred flood depth of 0.4m in interior floodplain by overtopping under PMF scenario, and maximum flood depth was predicted up to 1.1 m. Moreover, for the downstream of the Changri reservoir, the total amount of the maximum flood damage by dam-break was calculated nearly 1.2 billion won by IDEM.

Analysis on Factors Influencing the Achievement of Break-even Point among the Creativity and Skill-based Sole Proprietors (1인 창조기업의 손익분기점 도달 영향요인 분석)

  • Kim, Sun-Young;Lee, Byung-heon
    • Asia-Pacific Journal of Business
    • /
    • v.12 no.1
    • /
    • pp.151-163
    • /
    • 2021
  • Purpose - The break-even point refers to the point where total profit and total cost coincide, and from this point on, the entrepreneur's decision-making takes a different route. Strategic decisions can be made for more efficient operation and eventually for more likelihood for growth and sustainability if a startup figures out when it recoups the investment and switches to a net profit. Design/methodology/approach - 748 creativity and skill-based sole proprietors in manufacturing industry were examined to demonstrate the effect of the entrepreneur's entrepreneurial experience and education level, the business launch preparation time, or the self-financing on the achievement of break-even point. Findings - While the business launch preparation time lowered the likelihood of reaching a break-even point, self-financing increased the likelihood. As a result of further analysis by subdividing into subgroups according to skill level, only the business launch preparation time was statistically significant in the highly skilled industries. In the low skilled industries, in addition to the business launch preparation time, the CEO's education level and the self-financing were statistically significant. Research implications or Originality - The longer the business launch preparation time, the higher the start-up cost, which increases the burden of initial cost recovery, and the agile response to market changes is thereby delayed, resulting in the business idea losing its appeal. Self-financing not only provides stability and strong motivation for the business operation but also promotes careful spending which contributes to the achievement of break-even point. In particular, it is found that practical experience is more useful than theoretical knowledge in low skilled industries. Due to the limitation of secondary data based on the recollection, the time required to reach a break-even point, percentage of financing sources, etc. may include cognitive errors. In addition, variables are not included that explain the characteristics of creativity and skill-based sole proprietorship, so it is necessary to exercise caution with the actual application.

Variation of Grain Quality of Rice Varieties Grown at Different Locations II. Relationship between Characteristics Related to Grain Quality (벼품종의 재배지역에 따른 미질특성변이 II. 미질관련형질 상호간의 관계)

  • Kwang-Ho Kim
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.35 no.2
    • /
    • pp.137-145
    • /
    • 1990
  • Six commercial rice varieties were cultivated at different locations in 1987 and 1988. Rice samples harvested from 8 to 20 locations for a variety each year were used to measure or observe grain appearance, amylose content and alkali digestibility, cooked rice texture using rheometer, gelatinization and viscosity of rice flour using amylograph, and eating Quality of cooked rice by sensory evaluation. Relationship between Quality characteristics showing large locational variation were analized to approach the long-term objective, rice grain Quality standardization. Percent white-center and white-belly grain of the same variety showed great variation between locations, but did not affect on 1000-grain weight, amylose content and alkali digestibility, amylogram and rheogram characteristics, and eating Quality of cooked rice. Positive correlationship were obtained between maximum viscosity and break down, and maximum viscosity and alkali digestibility. Set back was correlated negatively with maximum viscosity, break down and alkali digestibility. Rice samples having significantly lower values of maximum viscosity and break down and higher set back value at the same time showed higher ADV and lower texture palatability index (TPI) and viscousness/hardness ratio (Vi/H), and lower sensory evaluation score of cooked rice compared with those of rices having typically higher values of maximum viscosity and break down and lower set back value. When TPI, Vi/H and overall sensory eating score of cooked rices measured were divided into three categories, high, medium and low using deviation from locational mean value of a variety, many of rice samples having high TPI or high Vi/H showed medium or high in overall sensory eating score of cooked rice.

  • PDF

Modeling of the Failure Rates and Estimation of the Economical Replacement Time of Water Mains Based on an Individual Pipe Identification Method (개별관로 정의 방법을 이용한 상수관로 파손율 모형화 및 경제적 교체시기의 산정)

  • Park, Su-Wan;Lee, Hyeong-Seok;Bae, Cheol-Ho;Kim, Kyu-Lee
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.7
    • /
    • pp.525-535
    • /
    • 2009
  • In this paper a heuristic method for identifying individual pipes in water pipe networks to determine specific sections of the pipes that need to be replaced due to deterioration. An appropriate minimum pipe length is determined by selecting the pipe length that has the greatest variance of the average cumulative break number slopes among the various pipe lengths used. As a result, the minimum pipe length for the case study water network is determined as 4 m and a total of 39 individual pipe IDs are obtained. The economically optimal replacement times of the individual pipe IDs are estimated by using the threshold break rate of an individual pipe ID and the pipe break trends models for which the General Pipe Break Prediction Model(Park and Loganathan, 2002) that can incorporate the linear, exponential, and in-between of the linear and exponetial failure trends and the ROCOFs based on the modified time scale(Park et al., 2007) are used. The maximum log-likelihoods of the log-linear ROCOF and Weibull ROCOF estimated for the break data of a pipe are compared and the ROCOF that has a greater likelihood is selected for the pipe of interest. The effects of the social costs of a pipe break on the optimal replacement time are also discussed.