• Title/Summary/Keyword: Break's performance

Search Result 115, Processing Time 0.029 seconds

Characterization and performance of post treated PVDF hollow fiber membrane

  • Eman S. Sayed;Hayam F. Shaalan;Magda I. Marzouk;Heba A. Hani
    • Membrane and Water Treatment
    • /
    • v.15 no.2
    • /
    • pp.79-88
    • /
    • 2024
  • Modification of Polyvinylidene fluoride (PVDF) hollow fiber membranes (HFMs) characteristics and performance were investigated via post treatment using different oxidants. sodium hypochlorite (NaOCl), hydrogen peroxide (H2O2) and potassium persulfate (KPS). Fourier transform infrared (FTIR) and Proton nuclear magnetic resonance (1H-NMR) results revealed no structural differences after post treatment. Cross-sectional micrographs show finger-like structures at the outer and inner walls of the HFMs and sponge-like structures in middle, where NaOCl and KPS post treated fibers exhibited a decrease in finger-like structures in addition to aggregates appearing on the surface, consequently leading to an increase in the surface roughness (Ra) from 48 nm to 52.8nm and 56 nm, respectively. Hydrogen peroxide post treatment only was observed to decrease the water contact angle from 98° to 81.4°. It was also observed that the elongation at break and the modulus deceased after NaOCl post treatment from 34.5 to 28.5% and from 19.3 Mpa to 16.6 Mpa, respectively. Moreover, pure water flux after H2O2 post treatment increased from 87.8 LMH/bar to 113 LMH/bar at 0.45 bar, while no changes were detected for the methylene blue dye rejection (74%) between raw and hydrogen peroxide post treated fibers at the same pressure. According to the findings hydrogen peroxide post treated PVDF HFMs have the most uniform surfaces, with almost no alterations in structural and mechanical properties or porosities with enhanced hydrophilicity and pure water flux maintaining appropriate rejection. Therefore, it is considered an efficient surface modifying agent for UF/NF membranes or low-pressure separators.

Numerical Simulation of Subaerial and Submarine Landslides Using the Finite Volume Method in the Shallow Water Equations with (b, s) Coordinate ((b, s) 좌표로 표현된 천수방정식에 유한체적법을 사용하여 해상 및 해저 산사태 수치모의)

  • Pham, Van Khoi;Lee, Changhoon;Vu, Van Nghi
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.4
    • /
    • pp.229-239
    • /
    • 2019
  • A model of landslides is developed using the shallow water equations to simulate time-dependent performance of landslides. The shallow water equations are derived using the (b, s) coordinate system which can be applied in both river and ocean. The finite volume scheme employing the HLL approximate Riemann solver and the total variation diminishing (TVD) limiter is applied to deal with the numerical discontinuities occurring in landslides. For dam-break water flow and debris flow, numerical results are compared with analytical solutions and experimental data and good agreements are observed. The developed landslide model is successfully applied to predict subaerial and submarine landslides. It is found that the subaerial landslide propagates faster than the submarine landslide and the speed of propagation becomes faster with steeper bottom slope and less bottom roughness.

The design of a 32-bit Microprocessor for a Sequence Control using an Application Specification Integrated Circuit(ASIC) (ICEIC'04)

  • Oh Yang
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.486-490
    • /
    • 2004
  • Programmable logic controller (PLC) is widely used in manufacturing system or process control. This paper presents the design of a 32-bit microprocessor for a sequence control using an Application Specification Integrated Circuit (ASIC). The 32-bit microprocessor was designed by a VHDL with top down method; the program memory was separated from the data memory for high speed execution of 274 specified sequence instructions. Therefore it was possible that sequence instructions could be operated at the same time during the instruction fetch cycle. And in order to reduce the instruction decoding time and the interface time of the data memory interface, an instruction code size was implemented by 32-bits. And the real time debugging as single step run, break point run was implemented. Pulse instruction, step controller, master controllers, BIN and BCD type arithmetic instructions, barrel shit instructions were implemented for many used in PLC system. The designed microprocessor was synthesized by the S1L50000 series which contains 70,000 gates with 0.65um technology of SEIKO EPSON. Finally, the benchmark was performed to show that designed 32-bit microprocessor has better performance than Q4A PLC of Mitsubishi Corporation.

  • PDF

Scaling Analysis of Thermal Hydraulics Phenomena in the Nuclear Reactor Vessel Downcomer during the Reflood Phase of LBLOCA (대형냉각재 상실사고 재관수 기간 동안, 차세대 원자로 강수부 내의 열수력 현상 모의를 위한 실험장치 척도해석)

  • Yun, B.J.;Song, C.H.;Kwon, T.S.;Euh, D.J.;Chu, I.C.;Yoon, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.821-827
    • /
    • 2001
  • As one of the advanced design features of the Korea next generation reactor, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLl) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood period of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, a new scaling method, using time and velocity reduced linear scaling law, is suggested for the design of a scaled-down experimental facility to investigate the direct ECC bypass phenomena in PWR downcomer.

  • PDF

Factors of Trust Building of Internet Shopping Mall in Initial Start-up Business (창업초기 인터넷쇼핑몰의 신뢰형성요인)

  • Kim, Young-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.10
    • /
    • pp.221-228
    • /
    • 2007
  • It is more important how to maintain and develop the company than starting any business. The matter of trust building in the early stage of start up company is a main cause to make or break business performance. This study analyzes the primary factor to the influence of matter of trust formation in the early stage of starting business at internet shopping mall. Also, We are here concerned with the strategies on the building brand to shopping mall of e-company and the increasing sales. To accomplish the aim of this paper is examined a concept of trust, consumer's purchase behavior and the factor of trust formation from the basis of preceding research, It was found from the result of an hypothesis testing for positive analyze that information quality, web design and shopping convenience influence factors to the initial trust.

Testing of a discontinuity point in the log-variance function based on likelihood (가능도함수를 이용한 로그분산함수의 불연속점 검정)

  • Huh, Jib
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • Let us consider that the variance function in regression model has a discontinuity/change point at unknown location. Yu and Jones (2004) proposed the local polynomial fit to estimate the log-variance function which break the positivity of the variance. Using the local polynomial fit, Huh (2008) estimate the discontinuity point of the log-variance function. We propose a test for the existence of a discontinuity point in the log-variance function with the estimated jump size in Huh (2008). The proposed method is based on the asymptotic distribution of the estimated jump size. Numerical works demonstrate the performance of the method.

  • PDF

Direct ECC Bypass Phenomena in the MIDAS Test Facility During LBLOCA Reflood Phase

  • B.J. Yun;T.S. Kwon;D.J. Euh;I.C. Chu;Park, W.M.;C.H. Song;Park, J.K.
    • Nuclear Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.421-432
    • /
    • 2002
  • As one of the advanced design features of the APR1400, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLI) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood phase of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, test results of direct ECC bypass performed in the steam-water test facility tailed MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) are presented. The test condition is determined, based on the preliminary analysis of TRAC code, by applying the ‘modified linear scaling method’with the l/4.93 length scale . From the tests, ECC direct bypass fraction, steam condensation rate and information on the flow distribution in the upper annulus downcomer region are obtained.

A Study on the Implementation of KH LAN(I) (KH LAN(I) 구현에 관한 연구)

  • 유황빈;이대영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.6
    • /
    • pp.621-633
    • /
    • 1987
  • In this paper, for the purpose of constructing LAN(Local Area Network) with Token ring type Star-wired ring method, we implemented an in board network adapter and a concentrator using microprocessor. Using cconcentrato's communication controlling function, the concentator prevents a break of communication by by-passing the fault network adapter. Because, in the data transfer period, a concentrator recognized the network adapter at transmit and receiving side to construct single by -pass line and reduces ring latency time at both sides, this method can keep a high throughput in high and low load. Being considered the result of performance evaluation for the method our study employed, high throughput can be obtained.

  • PDF

Development of CAE Service Platform Based on Cloud Computing Concept (클라우드 컴퓨팅기반 CAE서비스 플랫폼 개발)

  • Cho, Sang-Hyun
    • Journal of Korea Foundry Society
    • /
    • v.31 no.4
    • /
    • pp.218-223
    • /
    • 2011
  • Computer Aided Engineering (CAE) is very helpful field for every manufacturing industry including foundry. It covers CAD, CAM, and simulation technology also, and becomes as common sense in developing new products and processes. In South Korea, more than 600 foundries exist, and their average employee number is less than 40. Moreover, average age of them becomes higher. To break out these situations of foundry, software tools can be effective, and many commercial software tools had already been introduced. But their high costs and risks of investment act as difficulties in introducing the software tools to SMEs (Small and Medium size Enterprise). So we had developed cloud computing platform to propagate the CAE technologies to foundries. It includes HPC (High Performance Computing), platforms and software. So that users can try, enjoy, and utilize CAE software at cyber space without any investment. In addition, we also developed platform APIs (Application Programming Interface) to import not only our own CAE codes but also 3rd-party's packages to our cloud-computing platforms. As a result, CAE developers can upload their products on cloud platforms and distribute them through internet.

Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated lest using Transient Surge (과도서지를 이용한 가속열화 시험법에 따른 견인전동기 고정자 코일의 전기적 특성 변화)

  • 박현준;장동욱;이길헌;최종선;김저우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.783-789
    • /
    • 2003
  • The winding problems of traction motor are the major determinant of motor's life. The root cause of winding failure is gradual deterioration of the insulation due to thermal, electrical, mechanical and environmental stresses. The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking, the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss(tan$\sigma$), capacitance and partial discharge. The method of diagnosis is able to analyze the insulation condition and evaluate the life of the traction motor.