• Title/Summary/Keyword: Break

Search Result 3,586, Processing Time 0.035 seconds

The Formation of Residual Stresses and the Surface Fracture by the Break-in Process (길들이기에 의한 잔류응력의 형성과 표면파괴)

  • 김진욱;이영제
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.159-165
    • /
    • 2000
  • In this paper the residual stresses on lubricated sliding surfaces were measured during break-in procedure and up to scuffing by the X-ray diffraction method. The cylinder-on-disk type tribometer was used with the line-contact geometry. Scuffing tests were done using a constant load. In the break-in procedure the loads were increased from very low values in several steps. It was found that the sliding surfaces with break-in represented relatively higher values of residual compressive stresses than those without break-in. The residual stresses below the surfaces showed the small amount of stress increases. The results of scuffing tests with and without break-in showed the same trends as break-in tests did. However, in case of tests with break-in procedure the stresses below the surfaces showed very large increases in the residual compressive stresses. From the tests of break-in and scuffing, it was found that the increases in scuffing lives were related with the increases of residual stresses on the lubricated sliding surfaces with break-in.

  • PDF

The Changes of Residual Stresses on Sliding Surfaces during Break-in and Scuffing (길들이기 과정과 표면파괴 과정에서의 잔류응력 변화)

  • 김진욱;이영제
    • Tribology and Lubricants
    • /
    • v.16 no.3
    • /
    • pp.182-187
    • /
    • 2000
  • In this paper the residual stresses on lubricated sliding surfaces were measured during break-in procedure and up to scuffing by the X-ray diffraction method. The cylinder-on-disk type tribometer was used with the line-contact geometry. Scuffing tests were done using a constant load. In the break-in procedure the loads were increased from very low values in several steps. It was found that the sliding surfaces with break-in represented relatively higher values of residual compressive stresser than those without break-in. The residual stresses below the surfaces showed the small amount of stress increases. The results of scuffing tests with and without break-in showed the same trends as break-in tests did. However, in case of tests with break-in procedure the stresses below the surfaces showed very large increases in the residual compressive stresses. From the tests of break-in and scuffing, it was found that the increases in scuffing lives were related with the increases of residual stresses on the lubricated sliding surfaces with break-in.

A Unit Selection Methods using Flexible Break in a Japanese TTS (일본어 합성기에서 유동 Break를 이용한 합성단위 선택 방법)

  • Song, Young-Hwan;Na, Deok-Su;Kim, Jong-Kuk;Bae, Myung-Jin;Lee, Jong-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.8
    • /
    • pp.403-408
    • /
    • 2007
  • In a large corpus-based speech synthesizer, a break, which is a parameter influencing the naturalness and intelligibility, is used as an important feature during a unit selection process. Japanese is a language having intonations, which ate indicated by the relative differences in pitch heights and the APs(Accentual Phrases) are placed according to the changes of the accents while a break occurs on a boundary of the APs. Although a break can be predicted by using J-ToBI(Japanese-Tones and Break Indices), which is a rule-based or statistical approach, it is very difficult to predict a break exactly due to the flexibility. Therefore, in this paper, a method is to conduct a unit search by dividing breaks into two types, such as a fixed break and a flexible break, in order to use the advantages of a large-scale corpus, which includes various types of prosodies. As a result of an experiment, the proposed unit selection method contributed itself to enhance the naturalness of synthesized speeches.

Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

  • Bae, Hwang;Kim, Dong Eok;Ryu, Sung-Uk;Yi, Sung-Jae;Park, Hyun-Sik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.968-978
    • /
    • 2017
  • Three small-break loss-of-coolant accident (SBLOCA) tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor), i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal-hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are slightly different during the early stage of the transient after a break simulation. A safety injection using a high-pressure pump effectively cools down and recovers the inventory of a reactor coolant system. The global trends show reproducible results for an SBLOCA scenario with three different break locations. It was confirmed that the safety injection system is robustly safe enough to protect from a core uncovery.

A Unit Selection Methods using Variable Break in a Japanese TTS (일본어 TTS의 가변 Break를 이용한 합성단위 선택 방법)

  • Na, Deok-Su;Bae, Myung-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.983-984
    • /
    • 2008
  • This paper proposes a variable break that can offset prediction error as well as a pre-selection methods, based on the variable break, for enhanced unit selection. In Japanese, a sentence consists of several APs (Accentual phrases) and MPs (Major phrases), and the breaks between these phrases must predicted to realize text-to-speech systems. An MP also consists of several APs and plays a decisive role in making synthetic speech natural and understandable because short pauses appear at its boundary. The variable break is defined as a break that is able to change easily from an AP to an MP boundary, or from an MP to an AP boundary. Using CART (Classification and Regression Trees), the variable break is modeled stochastically, and then we pre-select candidate units in the unit-selection process. As the experimental results show, it was possible to complement a break prediction error and improve the naturalness of synthetic speech.

  • PDF

A Performance Improvement Method using Variable Break in Corpus Based Japanese Text-to-Speech System (가변 Break를 이용한 코퍼스 기반 일본어 음성 합성기의 성능 향상 방법)

  • Na, Deok-Su;Min, So-Yeon;Lee, Jong-Seok;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.155-163
    • /
    • 2009
  • In text-to-speech systems, the conversion of text into prosodic parameters is necessarily composed of three steps. These are the placement of prosodic boundaries. the determination of segmental durations, and the specification of fundamental frequency contours. Prosodic boundaries. as the most important and basic parameter. affect the estimation of durations and fundamental frequency. Break prediction is an important step in text-to-speech systems as break indices (BIs) have a great influence on how to correctly represent prosodic phrase boundaries, However. an accurate prediction is difficult since BIs are often chosen according to the meaning of a sentence or the reading style of the speaker. In Japanese, the prediction of an accentual phrase boundary (APB) and major phrase boundary (MPB) is particularly difficult. Thus, this paper presents a method to complement the prediction errors of an APB and MPB. First, we define a subtle BI in which it is difficult to decide between an APB and MPB clearly as a variable break (VB), and an explicit BI as a fixed break (FB). The VB is chosen using the classification and regression tree, and multiple prosodic targets in relation to the pith and duration are then generated. Finally. unit-selection is conducted using multiple prosodic targets. In the MOS test result. the original speech scored a 4,99. while proposed method scored a 4.25 and conventional method scored a 4.01. The experimental results show that the proposed method improves the naturalness of synthesized speech.

Evaluation of Post-LOCA Long Term Cooling Performance in Korean Standard Nuclear Power Plants

  • Bang, Young-Seok;Jung, Jae-Won;Seul, Kwang-Won;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.12-24
    • /
    • 2001
  • The post-LOCA long term cooling (LTC) performance of the Korean Standard Nuclear Power Plant (KSNPP) is analyzed for both small break loss-of-coolant accidents (LOCA) and large break LOCA at cold leg. The RELAP5/MOD3.2.2 beta code is used to calculate the LTC sequences based on the LTC plan of the Korean Standard Nuclear Power Plants (KSNPP). A standard input model is developed such that LOCA and the followed LTC sequence can be calculated in a single run for both small break LOCA and large break LOCA. A spectrum of small break LOCA ranging from \ulcorner.02 to 0.5 k2 of break area and a double-ended guillotine break are analyzed. Through the code calculations, the thermal-hydraulic behavior and the boron behavior are evaluated and the effect of the important action including the safety injection tank (SIT isolation and the simultaneous injection in LTC procedure is investigated. As a result, it is found that the sufficient margin is available in avoiding the boron precipitation in the core. It is also found that a further specific condition for the SIT isolation action need to be setup and it is recommended that the early initiation of the simultaneous injection be taken for larger break LTC sequences.

  • PDF

Comparisons of Test-Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.3
    • /
    • pp.147-150
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures. Therefore, it is essential to evaluate their strength in a reliable way. Methods: Twenty-five subjects participated in this study. Unilateral isometric hip abductor muscle strength was measured in side-lying, with use of a specialized tensiometer using smart KEMA system for make test, of a hand held dynamometer for break test. Coefficients of variation, and intra class correlation coefficients were calculated to determine test-retest reliability of hip abductor strength. Results: In make test, maximal hip abductor strength in the side-lying position was significantly higher compared with break test (p<0.05). Additionally, Test-retest reliability of hip abductor strength measurements in terms of coefficients of variation (3.7% for make test, 16.1% for break test) was better in the side-lying position with make test. All intraclass correlation coefficients with break test were lower than make test (0.90 for make test, 0.73 for break test). Conclusion: The side-lying body position with make test offers more reliable assessment of unilateral hip abductor strength than the same position with break test. Make test in side-lying can be recommended for reliable measurement of hip abductor strength in subjects with pelvic drop.

Best Estimate Small Break LOCA Analysis for KNGR SIS Optimization

  • Song, Jin-Ho;Lim, Hong-Sik;Bae, Kyoo-Hwan;Lee, Joon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.417-422
    • /
    • 1996
  • The KNGR has an advanced ECCS design feature which employs four mechanically-separated SI trains where each train consisting of one HPSI pump and one SIT injects ECC water directly into the reactor vessel downcomer annulus. To demonstrate that the KNGR ECCS design features meet the EPRI ALWR requirements of no core uncovery for a break of up to 6 inch diameter, small break LOCA cases with various break sizes were analyzed using a best-estimate analytical procedure. Two kinds of break locations are considered: cold leg and DVI line breaks. It was observed that the KNGR ECC design can tolerate a cold leg break of up to 10 inches with no core uncovery. However. since DVI line break with 6 inch diameter undergoes slight core uncovery. further investigation is required for KNGR SIS optimization.

  • PDF

Optimal Pipe Replacement Analysis with a New Pipe Break Prediction Model (새로운 파괴예측 모델을 이용한 상수도 관의 최적 교체)

  • Park, Suwan;Loganathan, G.V.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.16 no.6
    • /
    • pp.710-716
    • /
    • 2002
  • A General Pipe Break Prediction Model that incorporates linear and exponential models in its form is developed. The model is capable of fitting pipe break trends that have linear, exponential or in between of linear and exponential trend by using a weighting factor. The weighting factor is adjusted to obtain a best model that minimizes the sum of squared errors of the model. The model essentially plots a best curve (or a line) passing through "cumulative number of pipe breaks" versus "break times since installation of a pipe" data points. Therefore, it prevents over-predicting future number of pipe breaks compared to the conventional exponential model. The optimal replacement time equation is derived by using the Threshold Break Rate equation by Loganathan et al. (2002).