• 제목/요약/키워드: Brazing materials

검색결과 117건 처리시간 0.018초

세라믹소재를 이용한 해수압센서 제작 및 전기적 특성 연구 (A Study on the Fabrication and Electrical Characteristics of Hydraulic Pressure Sensors by Using Ceramics Materials)

  • 박성현;김은섭;정정균
    • 한국전기전자재료학회논문지
    • /
    • 제28권6호
    • /
    • pp.384-389
    • /
    • 2015
  • In this paper, we fabricated ceramic body and sapphire wafer in order to develop a hydraulic pressure sensor with high sensitivity and high temperature stability. The sapphire wafer was adopted with a membrane of capacitance ceramic pressure sensor. The capacitance value of the sensor for the finite element analysis(FEM) showed a linear pressure characteristics. Membrane was processed with a diameter of 32.4 mm and a thickness of 1 mm by using alumina powders. Ceramic body was processed with a diameter 32.4 mm and a thickness 5 mm. The capacitance pressure sensor was made with high heat treatment of the ceramic body and the sapphire wafer. Initially capacitance of the pressure sensor was 50 pF and a capacitance of 110 pF was measured from 5 bar pressure. Output voltage of 5 V was appeared at 5 bar pressure.

Ni기 삽입금속에 의해 진공 브레이징된 STS303-Cu의 특성평가 (Evaluation of the STS303-Cu vacuum-brazed by Ni-based alloy)

  • 장세훈;홍지민;최세원;강창석;김호성;오익현
    • 한국재료학회지
    • /
    • 제17권6호
    • /
    • pp.293-297
    • /
    • 2007
  • Microstructure and tensile strength of the vacuum brazed stainless steel(STS303) and Cu were investigated. For brazing, the BNi-2, 3, 4, 6 and 7 (A.W.S standard) were used as filler metals. The Oxides such as $Cr_2O_3$ and $SiO_2$ were observed at brazed layers between STS303 and Cu matrix. Also, the intermetallic compounds of Cr-B and Ni-P were observed at brazed layers. Brazed STS303-Cu specimens with BNi-2, 3, 4 filler metals showed almost elastic deformation followed by plastic yielding and strain hardening up to a peak stress. On the other hand, it is likely that the fracture of the brazed specimens with BNi-6 and 7 was occurred in elastic range without plastic yielding up to a peak stress. Among these filler metals, the BNi-2 brazed at $1050^{\circ}C$ showed excellent wettability and the highest tensile strength (101.6MPa).

접합 판형 열교환기(BPHE)의 내부 코팅에 따른 소재 특성 및 성능 평가에 관한 연구 (Study on the material properties and heating efficiency according to the internal surface coating of the brazed plate heat exchanger (BPHE))

  • 정항철;양현석;김현종;박종포
    • 한국결정성장학회지
    • /
    • 제30권6호
    • /
    • pp.237-243
    • /
    • 2020
  • 본 연구에서는 STS-316 플레이트와 구리(Cu) 브레이징으로 구성된 접합 판형 열교환기(BPHE, Brazed Plate Heat Exchanger)의 내식성과 열효율 성능 향상을 위해 실란계 코팅을 적용하고자 하였다. 코팅 재료에 따른 부식 및 접촉각을 평가하여 선정된 코팅재료를 열교환기에 적용하였으나, 전열 성능 평가 결과 코팅하지 않은 열교환기에 비해 열효율이 떨어지는 결과가 나타났다. 이는 접합 판형 열교환기 내부의 유로에 코팅제의 고착화 및 표면의 잔여 코팅제가 열저항으로 작용하여 열전달을 방해는 것으로 분석되었다. 이는 내부에 미세한 유로가 존재하는 판형 열교환기의 구조적인 특성에 기인한 것으로, 판형 열교환기 제작 공정에서 사전에 유로 표면에 코팅 후 제작하는 것이 전열성능을 향상 시킬 수 있을 것으로 판단된다.

일방향응고 니켈기 초내열합금 GTD111에서 천이 액상확산 접합용 삽입금속의 개발에 관한 연구 (Development of Insert Metals for the Transient Liquid Phase Bonding in the Directional Solidified Ni Base Super Alloy GTD 111)

  • 이봉근;오인석;김길무;강정윤
    • 대한금속재료학회지
    • /
    • 제47권4호
    • /
    • pp.242-247
    • /
    • 2009
  • On the Transient Liquid Phase Bonding (TLPB) phenomenon with the MBF-50 insert metal at narrow gap (under 100), it takes long time for the bonding and the homogenizing. Typically, isothermal solidification is controlled by the diffusion of depressed element of B and Si. However, the amount of B and Si in the MBF-50 filler metal is large. This is reason of the long bonding time. Also, the MBF-50 filler metal did not contained Al and Ti which are ${\gamma}^{\prime}$ phases former. This is reason of the long homogenizing time. From the bonding phenomenon with the MBF-50 insert metal, we search main factors on the bonding mechanism and select several insert-metals for using the wide-gap TLPB. New insert-metals contained Al and Ti which are ${\gamma}^{\prime}$ phases former and decrease the B then the MBF-50. When the new insert-metal was used on the TLPB, the bonding time was decreased about 1/10 times and homogenizing heat treatment was no needed. In spite of the without homogenizing, the volume fraction of ${\gamma}^{\prime}$ phases in the boned interlayer was equal to homogenizing heat treated specimen which was TLPB with the MBF-50. Finally, the new insert metal named WG1 for the wide-gap TLPB is more efficient then the MBF-50 filler metal without decreasing the bonding characteristic.

AlN 세라믹스와 금속간 계면접합에 관한 연구: II. AlN/Cu 접합체의 잔류응력에 미치는 Mo 중간재의 영향 (A Study on the Interfacial Bonding between AlN Ceramics and Metals: II. Effect of Mo Interlayer on the Residual Stress of AlN/Cu Joint)

  • 박성계;김지순;유희;염영진;권영순
    • 한국재료학회지
    • /
    • 제9권10호
    • /
    • pp.970-977
    • /
    • 1999
  • 활성금속브레이징법으로 계면접합된 AlN/Cu 접합체의 잔류응력 완화에 미치는 Mo 중간재의 영향을 조사하였다. 유한요소법에 의한 응력 해석과 접합체 강도 측정, 파단면의 관찰을 행하였으며, 이들 결과를 비교, 분석하였다. 응력 해석 결과로부터, Mo 중간재를 사용할 경우 최대 잔류 주응력이 형성되는 위치가 AlN/삽입금속 계면으로부터 삽임금속/Mo 계면을 통하여 Mo 내부로 이동됨을 확인하였다.접합체의 자유표면에 형성되는 인장성분의 응력집중 위치는 Mo 중간재 두께가 증가됨에 따라 Cu/Mo 계면과 Mo/AlN 계면의 두 곳으로 분리되었으며, AlN측 잔류응력의 크기는 크게 감소하였다. 중간재를 사용하지 않은 경우 최대 접합강도가 52 MPa로 낮은 강도를 보였으나, 두께 400$\mu\textrm{m}$ 이상의 Mo 중간재를 사용한 접합체의 경우, 200 MPa 이상, 최대 275 MPa의 접합강도를 얻을 수 있었다.

  • PDF

안경테용 Ti 합금 홈선의 고주파유도가열처리에 따른 특성 변화에 관한 연구 (A Study on the Characteristics for High Frequency Induction Heating of Ti Alloy Groove Wire)

  • 박정식;장우영;이정영
    • 한국안광학회지
    • /
    • 제12권3호
    • /
    • pp.55-58
    • /
    • 2007
  • 티타늄과 그 합금은 경량성, 우수한 기계적 성질 그리고 우수한 내식성 때문에 주요한 안경테 소재로 사용되고 있다. 본 연구에서는 티타늄 합금 홈선에 대하여 안경테 브레이징용으로 사용되고 있는 고주파유도가열 장치를 이용한 열처리 시간의 변화에 따른 경도 및 미세조직의 변화에 대하여 조사하였다. ${\beta}-Ti$ 합금은 고주파유도가열처리 시간의 증가에 따라 경도값의 감소가 나타났으며, 이는 열처리 시간의 증가에 따른 결정립의 조대화 때문인 것으로 생각된다. Ti-325 합금의 고주파유도가열처리에서는 2초까지는 경도값이 감소하였으나, 3초에서는 급격히 증가하였다. 이는 2초까지는 결정립의 조대화에 의한 경도값의 감소가 일어나지만, 3초에서는 미세한 ${\alpha}+{\beta}$ 상의 층상조직이 발달하였기 때문으로 판단된다.

  • PDF

치과용 진공 융착 다이아몬드 드레서의 연삭성 연구 (Evaluation of the grinding performance of vacuum-brazed diamond dressers in dentistry)

  • 박수철;박종경
    • 대한치과기공학회지
    • /
    • 제46권3호
    • /
    • pp.101-106
    • /
    • 2024
  • Purpose: This study evaluated the potential of a vacuum-brazed dental diamond dresser as an alternative to commercially available electroplated diamond dressers and assess its suitability for clinical use. Methods: Commercially available electroplated diamond dressers were selected as the control group (n=5), whereas vacuum-brazed diamond dressers with 80 grit and 100 grit particles were fabricated as the experimental groups (n=5 each). Prepared specimens were evaluated for surface roughness, wear resistance, and abrasiveness against a wear-inducing element (ZrO2 ball). The results were reported as means and standard deviations. Statistical analyses were performed using one-way ANOVA followed by Tukey's HSD test using SPSS Statistics ver. 23.0 (IBM), with the significance level set at 0.05. Results: Surface roughness was highest in the 80 grit group (23.99±3.62 ㎛) followed by the 100 grit group (20.38±1.79 ㎛) and the control group (17.59±0.56 ㎛). Wear resistance was greatest in the control group (0.0060±0.0009 g) followed by the 80 grit group (0.0018±0.0003 g) and the 100 grit group (0.0013±0.0001 g). Abrasiveness against the ZrO2 ball was highest in the 80 grit group (0.120±0.007 g) followed by the 100 grit group (0.101±0.007 g) and the control group (0.086±0.004 g). Conclusion: This study offers key insights for enhancing the performance of diamond dressers through vacuum-brazing and is expected to aid in the development of more efficient and durable diamond dressers for future applications.