• Title/Summary/Keyword: Brain imaging study

Search Result 648, Processing Time 0.032 seconds

A Study on The Measurement of Cerebral Cortical Thickness in Patients with Mood Disorders (기분장애 환자의 대뇌 피질 두께 측정에 관한 연구)

  • Do-Hun Kim;Hyo-Young Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.73-81
    • /
    • 2024
  • This study compared the cortical thickness of patients with mood disorders and a control group to assess structural abnormalities. A retrospective study was conducted from September 2020 to August 2022 at the Department of Psychiatry, P Hospital in Yangsan, Gyeongsangnam-do. The study included 44 individuals diagnosed with mood disorders and 59 healthy individuals without any pathological lesions. The 3D-T1 MPRAGE images obtained from magnetic resonance imaging examinations were utilized, and FreeSurfer software was employed to measure cortical thickness. Statistical analysis involved independent samples t-tests to measure the differences in means between the two groups, and Cohen's d test was used to compare the effect sizes of the differences. Furthermore, the correlation between the measured average cortical thickness and Positive and Negative Syndrome Scale scores was analyzed. The research results revealed that patients with mood disorders exhibited decreased cortical thickness compared to the normal control group in both superior frontal regions, both rostral middle frontal regions, both caudal middle frontal regions, both pars opercularis, pars orbitals, pars triangularis regions, both superior temporal regions, both inferior temporal regions, both lateral orbitofrontal regions, both medial orbitofrontal regions, both fusiform regions, both posterior cingulate regions, both isthmus cingulate regions, both superior parietal regions, both inferior parietal regions, both supramarginal regions, left postcentral region, right bank of the superior temporal sulcus region, right middle temporal region, right rostral anterior cingulate region, and right insula region. Among them, regions that showed differences with effect sizes of 0.8 or higher were left fusiform (d=0.82), pars opercularis (d=0.94), superior frontal (d=0.88), right lateral orbitofrontal (d=0.85), and pars orbitalis (d=0.89). Additionally, there was a weak negative correlation between PANSS scores and average cortical thickness in both the left hemisphere (r=-0.234) and right hemisphere (r=-0.230). These findings are expected to be helpful in identifying areas of cortical thickness reduction in patients with mood disorders compared to healthy individuals and understanding the relationship between symptom severity and cortical thickness changes.

Measurement and Assessment of Absolute Quantification from in Vitro Canine Brain Metabolites Using 500 MHz Proton Nuclear Magnetic Resonance Spectroscopy: Preliminary Results (개의 뇌 조직로부터 추출한 대사물질의 절대농도 측정 및 평가: 500 MHz 고자장 핵자기공명분광법을 이용한 예비연구결과)

  • Woo, Dong-Cheol;Bang, Eun-Jung;Choi, Chi-Bong;Lee, Sung-Ho;Kim, Sang-Soo;Rhim, Hyang-Shuk;Kim, Hwi-Yool;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2008
  • The purpose of this study was to confirm the exactitude of in vitro nuclear magnetic resonance spectroscopy(NMRS) and to complement the defect of in vivo NMRS. It has been difficult to understand the metabolism of a cerebellum using in vivo NMRS owing to the generated inhomogeneity of magnetic fields (B0 and B1 field) by the complexity of the cerebellum structure. Thus, this study tried to more exactly analyze the metabolism of a canine cerebellum using the cell extraction and high resolution NMRS. In order to conduct the absolute metabolic quantification in a canine cerebellum, the spectrum of our phantom included in various brain metabolites (i.e., NAA, Cr, Cho, Ins, Lac, GABA, Glu, Gln, Tau and Ala) was obtained. The canine cerebellum tissue was extracted using the methanol-chloroform water extraction (M/C extraction) and one group was filtered and the other group was not under extract processing. Finally, NMRS of a phantom solution and two extract solution (90% D2O) was progressed using a 500MHz (11.4 T) NMR machine. Filtering a solution of the tissue extract increased the signal to noise ratio (SNR). The metabolic concentrations of a canine cerebellum were more close to rat’s metabolic concentration than human’s metabolic concentration. The present study demonstrates the absolute quantification technique in vitro high resolution NMRS with tissue extraction as the method to accurately measure metabolite concentration.

  • PDF

A Study on Accuracy and Usefulness of In-vivo Dosimetry in Proton Therapy (양성자 치료에서 생체 내 선량측정 검출기(In-vivo dosimety)의 정확성과 유용성에 관한 연구)

  • Kim, Sunyoung;Choi, Jaehyock;Won, Huisu;Hong, Joowan;Cho, Jaehwan;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.171-180
    • /
    • 2014
  • In this study, the authors attempted to measure the skin dose by irradiating the actual dose on to the TLD(Thermo-Luminescence Dosimeter) and EBT3 Film used as the In-vivo dosimetry after planning the same treatment as the actual patient on a Phantom, because the erythema or dermatitis is frequently occurred on the patients' skin at the time of the proton therapy of medulloblastoma patient receiving the proton therapy. They intended to know whether there is the usefulness for the dosimetry of skin by the comparative analysis of the measured dose values with the treatment planned skin dose. The CT scan from the Brain to the Pelvis was done by placing a phantom on the CSI(Cranio-spinal irradiation) Set-up position of Medulloblastoma, and the treatment Isocenter point was aligned by using DIPS(Digital Image Positioning System) in the treatment room after planning a proton therapy. The treatment Isocenter point of 5 areas that the proton beam was entered into them, and Markers of 2 areas shown in the Phantom during CT scans, that is, in all 7 points, TLD and EBT3 Film pre-calibrated are alternatively attached, and the proton beam that the treatment was planned, was irradiated by 10 times, respectively. As a result of the comparative analysis of the average value calculated from the result values obtained by the repeated measurement of 10 times with the Skin Dose measured in the treatment planning system, the measured dose values of 6 points, except for one point that the accurate measurement was lacked due to the measurement position with a difficulty showed the distribution of the absolute dose value ${\pm}2%$ in both TLD and EBT Film. In conclusion, in this study, the clinical usefulness of the TLD and EBT3 Film for the Enterance skin dose measurement in the first proton therapy in Korea was confirmed.

Visualization and Localization of Fusion Image Using VRML for Three-dimensional Modeling of Epileptic Seizure Focus (VRML을 이용한 융합 영상에서 간질환자 발작 진원지의 3차원적 가시화와 위치 측정 구현)

  • 이상호;김동현;유선국;정해조;윤미진;손혜경;강원석;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • In medical imaging, three-dimensional (3D) display using Virtual Reality Modeling Language (VRML) as a portable file format can give intuitive information more efficiently on the World Wide Web (WWW). The web-based 3D visualization of functional images combined with anatomical images has not studied much in systematic ways. The goal of this study was to achieve a simultaneous observation of 3D anatomic and functional models with planar images on the WWW, providing their locational information in 3D space with a measuring implement using VRML. MRI and ictal-interictal SPECT images were obtained from one epileptic patient. Subtraction ictal SPECT co-registered to MRI (SISCOM) was performed to improve identification of a seizure focus. SISCOM image volumes were held by thresholds above one standard deviation (1-SD) and two standard deviations (2-SD). SISCOM foci and boundaries of gray matter, white matter, and cerebrospinal fluid (CSF) in the MRI volume were segmented and rendered to VRML polygonal surfaces by marching cube algorithm. Line profiles of x and y-axis that represent real lengths on an image were acquired and their maximum lengths were the same as 211.67 mm. The real size vs. the rendered VRML surface size was approximately the ratio of 1 to 605.9. A VRML measuring tool was made and merged with previous VRML surfaces. User interface tools were embedded with Java Script routines to display MRI planar images as cross sections of 3D surface models and to set transparencies of 3D surface models. When transparencies of 3D surface models were properly controlled, a fused display of the brain geometry with 3D distributions of focal activated regions provided intuitively spatial correlations among three 3D surface models. The epileptic seizure focus was in the right temporal lobe of the brain. The real position of the seizure focus could be verified by the VRML measuring tool and the anatomy corresponding to the seizure focus could be confirmed by MRI planar images crossing 3D surface models. The VRML application developed in this study may have several advantages. Firstly, 3D fused display and control of anatomic and functional image were achieved on the m. Secondly, the vector analysis of a 3D surface model was defined by the VRML measuring tool based on the real size. Finally, the anatomy corresponding to the seizure focus was intuitively detected by correlations with MRI images. Our web based visualization of 3-D fusion image and its localization will be a help to online research and education in diagnostic radiology, therapeutic radiology, and surgery applications.

  • PDF

Effects of the Variability of Individual Data on the Group Results; an Acupuncture Study Using fMRI (기능적 자기공명영상을 이용한 침 연구에 있어서 개체 별 다양성이 그룹분석에 미치는 영향 연구)

  • Bae, Seong-In;Jahng, Geon-Ho;Ryu, Chang-Woo;Lim, Sabina
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.277-289
    • /
    • 2009
  • Recently, functional MRI has been used to investigate the neurobiological mechanisms of acupuncture and the specificity of acupoint. The group data tend to be regarded as more important than the individual data in the most of previous studies. This study was designed to investigate the effect of the variability of individual data on the group results. A functional MRI (fMRI) of the whole brain was performed in fifteen healthy subjects during placebo and acupuncture stimulations at the ST36 acupoint. After remaining at rest for 30 seconds, the acupuncture was inserted and twisted at the rate of 2 Hz for 45 seconds and then the acupuncture was removed immediately. This process was repeated three times. Individual and group analyses were performed by voxel-based analyses using SPM2 software. Visual inspections of the activation and deactivation maps from individual sessions have shown the large variability across fifteen subjects. This means that the group data reflected the brain activation responses of only a few subjects. We suggest that the individual data should be presented to demonstrate the effect of acupuncture.

  • PDF

Concurrent Chemoradiation for Unresectable Pancreatic Cancer (절제 불가능한 췌장암의 동시항암화학방사선요법)

  • Kim, Yong-Bae;Seong, Jin-Sil;Song, Si-Young;Park, Seung-Woo;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.328-333
    • /
    • 2002
  • Purpose : To analyze the treatment results of concurrent chemoradiation with oral 5-FU plus Gemcitabine or Paclitaxel for unresectable pancreatic cancer. Materials & Methods : The patients, who were diagnosed by imaging modalities or by explo-laparotomy, were treated with concurrent chemoradiation. Radiotherapy was delivered to primary tumor and regional lymph nodes, and the total dose was 45 Gy. Patients received Gemcitabine $1,000\;mg/m^2$ or Paclitaxel $50\;mg/m^2$ weekly and oral 5-FU daily The total number of cycles of chemotherapy ranged from 1 to 39 (median, 11 cycles). The follow-up period ranged from 6 to 36 months, Survival was analyzed using the Kaplan-Meier method. Results : Fifty-four patients between Jan. 1999 to Nov. 2001 were included in this study. Forty-two patients who completed the planned treatment were included in this analysis. The patients' age ranged from 37 to 73 years (median, 50 years) and the male to female ratio was 30:12. Treatment was interrupted for 12 patients due to: disease progression for 6 $(50\%)$, poor performance status for 4 $(33.3\%)$, intercurrent disease for 1 $(8.3\%)$, and refusal for 1 $(8.3\%)$. Response evaluation was possible for 40 patients. One patient gained complete remission and 24 patients gained partial remission, hence the response rate was $59\%$. The survival rates were $46.7\%\;and\;17.0\%$ at 1 year and 2 years, respectively with a median survival time of 12 months. Patients treated with Paclitaxel showed superior outcomes compared to those patients treated with Gemcitabine, in terms of both response rate and survival rate although this difference was not statistically significant. Grade III or IV hematologic toxicity was shown in 8 patients $(19\%)$, while grade III or IV non-hematologic toxicity was shown in 5 patients $(12\%)$. Conclusion : Concurrent chemoradiation with oral 5-FU and Gemcitabine or Paclitaxel improves both the response rate and survival rate in patients with unresectable pancreatic cancer. A prospective study should be investigated in order to improve both the patient selection and the treatment outcome as well as to reduce the toxicity.

Radiation Dose Reduction in Digital Mammography by Deep-Learning Algorithm Image Reconstruction: A Preliminary Study (딥러닝 알고리즘을 이용한 저선량 디지털 유방 촬영 영상의 복원: 예비 연구)

  • Su Min Ha;Hak Hee Kim;Eunhee Kang;Bo Kyoung Seo;Nami Choi;Tae Hee Kim;You Jin Ku;Jong Chul Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.344-359
    • /
    • 2022
  • Purpose To develop a denoising convolutional neural network-based image processing technique and investigate its efficacy in diagnosing breast cancer using low-dose mammography imaging. Materials and Methods A total of 6 breast radiologists were included in this prospective study. All radiologists independently evaluated low-dose images for lesion detection and rated them for diagnostic quality using a qualitative scale. After application of the denoising network, the same radiologists evaluated lesion detectability and image quality. For clinical application, a consensus on lesion type and localization on preoperative mammographic examinations of breast cancer patients was reached after discussion. Thereafter, coded low-dose, reconstructed full-dose, and full-dose images were presented and assessed in a random order. Results Lesions on 40% reconstructed full-dose images were better perceived when compared with low-dose images of mastectomy specimens as a reference. In clinical application, as compared to 40% reconstructed images, higher values were given on full-dose images for resolution (p < 0.001); diagnostic quality for calcifications (p < 0.001); and for masses, asymmetry, or architectural distortion (p = 0.037). The 40% reconstructed images showed comparable values to 100% full-dose images for overall quality (p = 0.547), lesion visibility (p = 0.120), and contrast (p = 0.083), without significant differences. Conclusion Effective denoising and image reconstruction processing techniques can enable breast cancer diagnosis with substantial radiation dose reduction.

Characterization of Melanin-concentrating Hormone from Olive Flounder (Paralichthys olivaceus) (양식넙치 멜라닌 농축 호르몬의 특성)

  • Chung, In Young;Jeon, Jeong Min;Song, Young Hwan
    • Journal of Life Science
    • /
    • v.28 no.3
    • /
    • pp.284-292
    • /
    • 2018
  • The melanin-concentrating hormone (MCH), a cyclic hypothalamic peptide composed of 17 amino acids, was initially identified in chum salmon (Oncorhynchus keta) as a regulator of pigmentation. Mammalian MCHs are cyclic hypothalamic peptides composed of 19 amino acids that regulate food intake and energy homeostasis. The present study examined not only MCH expression of different tissues but also the melanohore aggregation and intracellular $Ca^{2+}$ influx of fMCH and the other MCH. Real-time qPCR showed that MCH expressed specially in the brain, gonad, and ovary, and expression of MCH was observed during the developmental stages. In the application of synthetic fMCH and both types of synthetic fMCH, dN-fMCH and dC-fMCH, scale melanophore induced significant changes in aggregation activity with various concentrations of MCH. Also, compared to hMCH and sMCH, fMCH exhibited a 36~99.85% increase in relative potency (%), whereas aggregation of dN-fMCH and dC-fMCH remained in a high concentration. However, dispersion was induced rapidly according to be low concentration of dN-fMCH and dC-fMCH. We show that fMCH and its derivates were bound human MCHR1 and rat MCHR expressed in HEK293T cells with nano-molar affinity and are likely to be ligand-induced to mobilize intracellular $Ca^{2+}$. These results may provide new ligands for binding assay with MCHew ligands, as a structure similar to the mammalian MCH structure was discovered in fish. Once the fMCH receptor system is in place, it can be compared to the MCH system of mammals in terms of MCH function.

The P300 Source Localization in the Patients with Obsessive-Compulsive Disorder using the LORETA Imaging and SPM (강박장애에서 LORETA 영상을 이용한 P300 국소원의 통계적 분석)

  • Park, Sung-Kun;Choi, Jung-Seok;Yu, Soh-Young;Lee, Bo Reom;Kang, Seung-Suk;Roh, Kyu Sik;Ha, Tae-Hyun;Kwon, Jun Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.10 no.2
    • /
    • pp.168-176
    • /
    • 2003
  • Objectives:We investigated the characteristics of P300 generators in obsessive-compulsive disorder(OCD) patients by using voxel-based statistical parametric mapping of current density images. Methods:P300 generators, produced by a rare target tone of 1500Hz under a frequent non-target tone of 1,000Hz, were measured in 15 right-handed OCD patients and 15 controls. Low Resolution Electromagnetic Tomography(LORETA), using a realistic head model of the boundary element method based on individual MRI, was applied to the 128-channel EEG. Statistical parametric mapping(SPM) was applied for the statistical analysis. Results:We found that both groups had the mean current density of P300 in the parietal, temporal and prefrontal lobe. There was a trend for decreased current density in the prefrontal area in OCD patients. The statistical comparison showed current density increase in the supraparietal area, a statistically significant longer P300 latency and a trend for reduced P300 amplitude in OCD patients. Conclusion:It suggests that P300 source of both groups exists in multiple brain regions at the same time. And both groups had no statistically significant differences in the current density of P300 except for increased current density in the supraparietal area in OCD patients. But, considering the statistically significant longer P300 latency, a trend for reduced P300 amplitude and relative mean current density reduction in the prefrontal area in OCD patients, this study suggests that the frontal lobe may have a reduced normal inhibitory process in OCD patients.

  • PDF

Multi-modality MEdical Image Registration based on Moment Information and Surface Distance (모멘트 정보와 표면거리 기반 다중 모달리티 의료영상 정합)

  • 최유주;김민정;박지영;윤현주;정명진;홍승봉;김명희
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.3_4
    • /
    • pp.224-238
    • /
    • 2004
  • Multi-modality image registration is a widely used image processing technique to obtain composite information from two different kinds of image sources. This study proposes an image registration method based on moment information and surface distance, which improves the previous surface-based registration method. The proposed method ensures stable registration results with low registration error without being subject to the initial position and direction of the object. In the preprocessing step, the surface points of the object are extracted, and then moment information is computed based on the surface points. Moment information is matched prior to fine registration based on the surface distance, in order to ensure stable registration results even when the initial positions and directions of the objects are very different. Moreover, surface comer sampling algorithm has been used in extracting representative surface points of the image to overcome the limits of the existed random sampling or systematic sampling methods. The proposed method has been applied to brain MRI(Magnetic Resonance Imaging) and PET(Positron Emission Tomography), and its accuracy and stability were verified through registration error ratio and visual inspection of the 2D/3D registration result images.