• 제목/요약/키워드: Brain PET

검색결과 197건 처리시간 0.031초

A brief review of non-invasive brain imaging technologies and the near-infrared optical bioimaging

  • Beomsue Kim;Hongmin Kim;Songhui Kim;Young-ran Hwang
    • Applied Microscopy
    • /
    • 제51권
    • /
    • pp.9.1-9.10
    • /
    • 2021
  • Brain disorders seriously affect life quality. Therefore, non-invasive neuroimaging has received attention to monitoring and early diagnosing neural disorders to prevent their progress to a severe level. This short review briefly describes the current MRI and PET/CT techniques developed for non-invasive neuroimaging and the future direction of optical imaging techniques to achieve higher resolution and specificity using the second near-infrared (NIR-II) region of wavelength with organic molecules.

A novel tricyclic derivative for PET imaging of the translocator protein

  • Kwon, Young-Do;Kim, Hee-Kwon
    • 대한방사성의약품학회지
    • /
    • 제2권1호
    • /
    • pp.37-42
    • /
    • 2016
  • The translocator protein (TSPO) has attracted scientist's attention for Positron Emission Tomography (PET) imaging due to correlation with brain cancer, stroke, and neurodegeneration. Recently, GE-180, a novel tricyclic derivative has been developed as a new high affinity agent for the TSPO and evaluated to confirm a possibility for the TSPO ligand. In this highlight review, several studies for the novel TSPO radiotracer are described.

가우시안 가중치 거리지도를 이용한 PET-CT 뇌 영상정합 (Co-registration of PET-CT Brain Images using a Gaussian Weighted Distance Map)

  • 이호;홍헬렌;신영길
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제32권7호
    • /
    • pp.612-624
    • /
    • 2005
  • 본 논문에서는 PET-CT 뇌 영상융합을 위해 가우시안 가중치 거리지도를 이용한 표면기반 영상정합을 제안한다. 제안방법은 중요 세 단계로 표면 특징점 추출, 가우시안 가중치 거리지도 생성, 가중치기반 유사도 평가로 구성된다. 첫째, PET 영상과 CT 영상에서 삼차원 역 영역성장법을 이용하여 머리영역을 분할하고 머리 영역과 같이 분할된 잡음 영역을 영역성장법기반 레이블링을 이용한 영역 크기 비교를 통해 제거한 후 선명화 처리 필터를 적용하여 머리 표면 특징점을 추출한다. 둘째, CT 영상에서 추출한 표면 특징점에 가우시안 가중치 거리지도를 생성하여 큰 변위에서도 최적의 위치로 견고하게 수렴하도록 한다. 셋째, 가중치기반 상호상관관계는 PET 영상에서 추출한 표면 특징점과 대응되는 CT 영상의 가우시안 가중치 거리지도를 이용하여 최적 위치를 탐색한다. 본 논문에서는 제안방법의 정확성과 견고성 검사를 위해 인공데이타를 이용하고, 수행시간과 육안평가를 위해 임상데이타를 이용한다. 정확성 검사는 임의로 변환된 인공데이타에 제안방법을 적용한 후 추출된 최적화 변환벡터와의 오차를 제곱근평균제곱오차를 이용하여 평가한다. 견고성 검사는 큰 변위와 잡음을 가지는 인공데이타에서 가중치기반 상호상관관계가 최적의 위치에서 최대를 이루는지를 평가한다 실험 결과 제안한 표면기반 영상정합이 기존 표면기반 영상정합보다 정확하고 견고하게 수렴됨을 알 수 있다.

SQUID를 이용한 뇌 청각유발 자장의 측정 (Measurements of Auditory Evoked Neuromagnetic Fields using Superconducting Quantum Interference Devices)

  • 이용호;권혁찬;김진목;박용기
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권4호
    • /
    • pp.421-428
    • /
    • 1997
  • 초전도양자간섭소자(SQUID)를 이용한 자장센서는 현재 개발된 자장센서중에서 감도가 가장 우수한 소자로서 인체의 두뇌에서 발생하는 매우 미약한 자장에 측정이 가능하다. 뇌자도측정은 현재 많이 사용되고 있는 전기적인 측정(뇌파, 뇌유발전위) 에 비해 공간분해능이 우수하고, fMRI나 PET에 비해서는 시간분해능이 우수하므로 뇌기능연구에 유용하게 사용될 수 있다. 본 연구에서는 뇌자도 측정을 위하여 4-채널 SQUID시스템을 개발하였다. 개발된 시스템의 주요 특징은 새로운 방식의 SQUID센서를 채택함으로서 간단한 회로로써 SQUID구동이 가능하도록 하였으며, 검출코일의 신뢰성을 향상시키기 위하여 집적화된 평면형 코일을 사용하였다. 외부 환경잡음을 소거하기 위하여 자기차폐실을 설치하였고, 개발된 SQUID 시스템을 이용하여 뇌의 청각령으로부터 발생하는 자기신호를 측정하였다.

  • PDF

PET-MR 시스템에 적용을 위한 실리콘 광증배센서의 온도 변화에 따른 성능 열화 분석 (An Analysis on Performance Degradation of Silicon Photomultipliers over Temperatures Variation for PET-MR Application)

  • 박경진;김형택;임경택;조민식;김기윤;조규성
    • 방사선산업학회지
    • /
    • 제9권3호
    • /
    • pp.143-151
    • /
    • 2015
  • A PET-MR system is particularly useful in diagnosing brain diseases. We have developed a prototype positron emission tomography (PET) system which can be inserted into the bore of a whole-body magnetic resonance imaging (MRI) system that enables us to obtain PET and MRI images simultaneously with a reduced cost. Silicon photomultipliers (SiPM) are appropriated as a PET detector at PET/MR system because detectors have a high gain and are insensitive to magnetic fields. Despite of its improved performance compared to that of PMT-based detectors, there is a problem of the photo-peak channel shift which is due to the increase of the temperature inside the ring detector. This problem will occur decreasing sensitivity of the PET and image distortion. In this paper, I quantitative analyze parameters of the KAIST SiPM depending on temperature by experiments. And I designed cooling methods in consideration of the degradation of sensors for correction of the temperature in the PET gantry. According to this research, we expect that distortive images and degradation of the sensitivity will not be occurred with using the above idea to reduce heat even if the PET system operates for a long time.

마커 기반과 특징기반에 기초한 뇌 영상의 3차원 정합방법의 비교 . 고찰 (A Survey and Comparison of 3D Registration of Brain Images Between Marker Based and Feature Based Method)

  • 조동욱;김태우;신승수;김지영;김동원;조태경
    • 한국콘텐츠학회논문지
    • /
    • 제3권3호
    • /
    • pp.85-97
    • /
    • 2003
  • MRI, CT, MRI, PET, SPECT, fMRI 등과 같은 단층의료영상은 병원에서 환자의 진단 및 치료 임상적 연구에서 폭넓게 사용되고 있다. 동일한 대상에 대하여 서로 다른 정보를 얻거나 비교를 하기 위하여 서로 다른 영상양식으로 촬영하거나 시간적 간격을 두고 단층영상을 획득하는 경우가 많다. 3차원 영상정합은 비교하고자 하는 두 영상을 하나의 3차원 좌표 공간으로 지도화하는 것이며, 크게 마커기반 정합과 특징기반 정합으로 분류된다. 뇌 영상의 3차원 정합은 뇌 수술부위 선정, 뇌 기능 연구, 뇌 지도화 연구 등에서 시각적 분석과 정량적 분석에서 중요한 위치를 차지한다. 본 논문에서는 뇌의 단층영상에 대하여 흔히 사용되고 있는 3차원 정합인 마커기반 정합법과 특징기반 정합법에 대하여 소개하고 이에 대한 비교 고찰을 행하고자 한다.

  • PDF

생성적 적대 신경망(Generative Adversarial Network)을 이용하여 획득한 18F-FDG Brain PET/CT 인공지능 영상의 비교평가 (Comparative Evaluation of 18F-FDG Brain PET/CT AI Images Obtained Using Generative Adversarial Network)

  • 김종완;김정열;임한상;김재삼
    • 핵의학기술
    • /
    • 제24권1호
    • /
    • pp.15-19
    • /
    • 2020
  • 본 연구는 최근에 활발히 연구되고 있는 딥러닝 기술인 생성적 적대 신경망(GAN)을 핵의학 영상에 적용하여 잠재적으로 유용성이 있는지 확인해보고자 하였다. 본원에서 18F-FDG Brain PET/CT검사를 진행한 30명의 환자를 대상으로 하였고 List모드로 15분 검사한 후 이를 1, 2, 3, 4, 5분 초기획득시간 이미지로 재구성하였다. 이 중 25명의 환자를 GAN모델의 학습을 위한 트레이닝 이미지로 사용하고 5명의 환자를 학습된 GAN모델의 검증을 위한 테스트 이미지로 사용하였다. 학습된 GAN모델에 입력으로 1, 2, 3, 4, 5분의 초기획득 이미지를 넣고 출력으로 15분 인공지능 표준획득 이미지를 획득한 후 이를 기존의 15분 표준획득시간 검사 이미지와 비교 평가하였다. 평가에는 정량화된 이미지 평가방법인 평균제곱오차, 최대신호 대 잡음비, 구조적 유사도 지수를 이용하였다. 평가 결과 초기획득시간 이미지에서 1에서 5분으로 갈수록 실제 표준획득시간 이미지에 가까운 평균제곱오차, 최대신호 대 잡음비, 구조적 유사도 지수 수치를 나타내었다. 이러한 연구를 통해 앞으로 인공지능 기술이 핵의학 분야에서 의료영상의 획득시간 단축과 관련하여 중요한 영향을 미칠 수 있을 것으로 사료된다.