• Title/Summary/Keyword: Brain, CT

Search Result 592, Processing Time 0.026 seconds

Arachnoid Granulations Mimicking Multiple Osteolytic Bone Lesions in the Occipital Bone

  • Park, Seong-Hyun;Park, Ki-Su;Hwang, Jeong-Hyun
    • Brain Tumor Research and Treatment
    • /
    • v.6 no.2
    • /
    • pp.68-72
    • /
    • 2018
  • We report a rare case of arachnoid granulations mimicking multiple osteolytic bone lesions. A 66-year-old woman was admitted to a local clinic for a regular checkup. Upon admission, brain CT showed multiple osteolytic lesions in the occipital bone. These needed to be differentiated from multiple osteolytic bone tumor. Subsequent brain MRI revealed that the osteolytic lesions were isointense to cerebrospinal fluid, hyperintense on T2-weighted image, hypointense on T1-weighted image, and with subtle capsules around the osteolytic lesions that were visible after gadolinium injection. A bone scan revealed no radiotracer uptake. The lesions were in both the transverse sinuses and the torcular herophili. With typical radiological appearances of the lesions, the osteolytic lesions were diagnosed as multiple arachnoid granulations. No further treatment was planned. A 1-year follow-up brain CT scan revealed no change. We should consider the possibility of arachnoid granulations when multiple osteolytic lesions are observed in the occipital bone.

Validation of the Simplified Motor Score for the Triage after Traumatic Brain Injury (두부 외상 환자의 중증도 평가 시 단순운동점수의 유용성)

  • Lee, Sang Kyong;Ryoo, Hyun Wook;Park, Jung Bae;Seo, Kang Suk;Chung, Jae Myung
    • Journal of Trauma and Injury
    • /
    • v.21 no.2
    • /
    • pp.71-77
    • /
    • 2008
  • Purpose: The Glasgow Coma Scale (GCS), though it is widely used for triage, has been criticized as being unnecessarily complex. Recently, a 3-point Simplified Motor Score (SMS, defined as obeys commands=2; localizes pain=1; withdrawals to pain or worse=0) was developed from the motor component of the GCS and was found to have a similar test performance for triage after traumatic brain injury when compared with the GCS as the criterion standard. The purpose of this study was to validate the SMS. Methods: We analyzed the patients who visited Kyungpook National University Hospital emergency center after traumatic brain injury from 2006 January to 2006 June. The test performance of the GCS, its motor component, and SMS relative to three clinically relevant traumatic brain injury outcomes (abnormal brain CT scans, Abbreviated Injury Scale $(AIS){\geq}4$, and mortality) were evaluated with areas under the receiver operating characteristic curves (AUCs). Results: Of 504 patients included in the analysis, 25.6% had an abnormal brain CT scans, 13.1% had $AIS{\geq}4$, and 5.0% died. The AUCs for the GCS, its motor component, and SMS with respect to the abnormal CT scans were 0.776, 0.715, and 0.716, and respectively, those for $AIS{\geq}4$ and mortality, were 0.969, 0.973, and 0.968, and 0.931, 0.909, and 0.909, respectively. Conclusion: The 3-point SMS demonstrated similar test performance when compared with the 15-point GCS score and its motor component for triage after traumatic brain injury in our populations.

Expression of Cancer-Testis Genes in Brain Tumors

  • Lee, Myoung-Hee;Son, Eun-Ik;Kim, Ealmaan;Kim, In-Soo;Yim, Man-Bin;Kim, Sang-Pyo
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.4
    • /
    • pp.190-193
    • /
    • 2008
  • Objective : Cancer-testis (CT) genes are considered promising candidates for immunotherapeutic approaches. The aim of this study was to investigate which CT genes should be targeted in immunotherapy for brain tumors. Methods : We investigated the expression of 6 CT genes (MAGE-E1, SOX-6, SCP-1, SSX-2, SSX-4, and HOMTES-85) using reverse-transcription polymerase chain reaction in 26 meningiomas and 32 other various brain tumor specimens, obtained from the patients during tumor surgery from 2000 to 2005. Results : The most frequently expressed CT genes of meningiomas were MAGE-E1, which were found in 22/26 (85%) meningioma samples, followed by SOX-6 (9/26 or 35%). Glioblastomas were most frequently expressed SOX-6 (6/7 or 86%), MAGE-E1 (5/7 or 71%), followed by SSX-2 (2/7 or 29%) and SCP-1 (1/7 or 14%). However, 4 astrocytomas, 3 anaplastic astrocytomas, and 3 oligodendroglial tumors only expressed MAGE-E1 and SOX-6. Schwannomas also expressed SOX-6 (5/6 or 83%), MAGE-E1 (4/6 or 67%), and SCP-1 (2/6 or 33%). Conclusion : The data presented here suggest that MAGE-E1 and SOX-6 genes are expressed in a high percentage of human central nervous system tumors, which implies the CT genes could be the potential targets of immunotherapy for human central nervous system tumors.

Evaluation of Images Depending on an Attenuation Correction in a Brain PET/CT Scan

  • Choi, Eun-Jin;Jeong, Mon-Taeg;Dong, Kyung-Rae;Kwak, Jong-Gil;Choi, Ji-Won;Ryu, Jae-Kwang
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.267-276
    • /
    • 2018
  • A Hoffman 3D Brain Phantom was used to evaluate two PET/CT scanners, BIO_40 and D_690, according to the radiation dose of CT (low, medium and high) at a fixed kilo-voltage-peak (kVp) with the tube current(mA) varied in 17~20 stages(Bio_40 PET/CT scanner: the tube voltage was fixed to 120 kVp, the effective tube current(mAs) was increased from 33 mAs to 190 mAs in 10 mAs increments, D_690 PET/CT scanner: the tube voltage was fixed to 140 kVp, tube current(mA) was increased from 10 mAs to 200 mAs in 10 mAs increments). After obtaining the PET image, an attenuation correction was conducted based on the attenuation map, which led to an analysis of the difference in the image. First, the ratio of white to gray matter for each scanner was examined by comparing the coefficient of variation (CV) depending on the average ratio. In addition, a blind test was carried out to evaluate the image. According to the study results, the BIO_40 and D_690 scanners showed a <1% change in CV value due to the tube current conversion. The change in the coefficients of white and gray matter showed that the Z value was negative for both scanners, indicating that the coefficient of gray matter was higher than that of white matter. Moreover, no difference was observed when the images were compared in a blind test.

CT of Late Complication of Central Nervous System after Radiation Therapy of Brain Tumors (뇌종양의 방사선치료후 발생한 만성변화의 CT소견)

  • Hong, Seong-Eon;Cho, Chong-Hee;Ahn, Chi-Yul
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.287-297
    • /
    • 1984
  • The normal intracranial structures are relatively resistant to therapeutic radiation, but may react adversely in a variety of ways, and the damage to nerve tissue may be slow in making its appearance, and once damage has occured the patient recovers slowly and incompletly. Therefore, it is important to consider the possibility of either recurrent tumor or late adverse effect in any patient who has had radiotherapy. The determination o( rnorphological/pathological correlation is very important to the therapeutic radiologist who uses CT scans to define a treatment volume, as well as to the clinician who wishes to explain the patient's clinical state in terms of regress, progression, persistence, or recurrence of tumor or radiation-induced edema or necrosis, The authors are obtained as following results ; 1. The field size(whole CNS, large, intermediate, small field) was variable according to the location and extension of tumor and histopathologic diagnosis, and the tatal tumor dose was 4,000 to 6,000 rads except one of recurred case of 9,100 rads. The duration of follow up CT scan was from 3 months to 5 year 10 months. 2, The histopathologic diagnosis of 9cases were glioblastoma multiforme(3 cases), pineal tumor (3), oligodendroglioma (1), cystic astrocytoma (1), pituitary adenoma (1) and their adverse effects after radiation therapy were brain atrophy (4 cases) , radiation necrosis(2), tumor recurrence with or without calcification (2), radiation·induced infarction (1). 3. The recurrent symptoms after radiation therapy of brain tumor were not always the results of regrowth of neoplasm, but may represent late change of irradiated brain. 4. It must be need that we always consider the accurate treatment planning and proper treatment method to reduce undesirable late adverse effects in treatment of brain tumors.

  • PDF

Evaluation of Database Comparison Methods for 18F-FDG Brain PET/CT (18F-FDG Brain PET/CT 검사를 위한 데이터 비교 방법의 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.62-66
    • /
    • 2015
  • Purpose Various database comparison methods(DCM) are used for analyzing functional neuro-imaging. It is possible to statistically evaluate decreased or increased metabolism of abnormal patient's brain by comparing with asymptomatic controls in DCM. And results of DCM are additionally used for easily explaining defect region. The aim of this study was to evaluate usefulness of statistical parametric mapping(SPM) and scenium. Materials and Methods Data of 15 patients($62.02{\pm}15.03year$) underwent $^{18}F-FDG$ brain PET/CT were collected and analyzed. Biograph TruePoint 40 with TrueV, (Siemens) was used as a PET/CT scanner. Scenium(version 4.0) in Syngo.via(version VA30A) and SPM99 were applied for statistical evaluation. Consistency between PET reading and result of DCM were evaluated by 5 nuclear medicine physicians through a questionnaire survey. SUV and SD changes were evaluated by changing iteration, gaussian filter and matrix size in scenium. And average required time for generating result of SPM99 and scenium was compared by 3 medical technologists. Results Consistency from the result of SPM99 and scenium showed 84% and 92.4% compare to PET reading. When iteration 4, FWHM 8 and matrix size 168, SUV and SD were decreased by 0.59%, 8.73%, 4.69%, 20.38% and 0.88%, 8.25% respectively compare to routine parameter(iteration 8, FWHM 2 and matrix size 336) of scenium. Average required time of SPM99 and Scenium took 282 seconds and 116 seconds to generate result. Conclusion Results of SPM99 and Scenium showed high consistency compare to PET reading. Various parameters can be controled by user when using SPM. However, normal database needs to be acquired. And it takes significant amount of time and effort for the first set up. On the other hand, Scenium provides normal database even though modifiable parameters are limited. Therefore, more informations could be provided for brain PET/CT if properly understanding and selecting each DCM.

  • PDF

Unexpected Severe Cerebral Edema after Cranioplasty : Case Report and Literature Review

  • Lee, Gwang Soo;Park, Sukh Que;Kim, Rasun;Cho, Sung Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.1
    • /
    • pp.76-78
    • /
    • 2015
  • This report details a case of unexpected, severe post-operative cerebral edema following cranioplasty. We discuss the possible pathological mechanisms of this complication. A 50-year-old female was admitted to our department with sudden onset of stuporous consciousness. A brain computed tomography (CT) revealed a subarachnoid hemorrhage with intracranial hemorrhage and subdural hematoma. Emergency decompressive craniectomy and aneurysmal neck clipping were performed. Following recovery, the decision was made to proceed with an autologous cranioplasty. The cranioplasty procedure was free of complications. An epidural drain was placed and connected to a suction system during skin closure to avoid epidural blood accumulation. However, following the procedure, the patient had a seizure in the recovery room. An emergency brain CT scan revealed widespread cerebral edema, and the catheter drain was clamped. The increased intracranial pressure and cerebral edema were controlled with osmotic diuretics, corticosteroids, and antiepileptic drugs. The edema slowly subsided, but new low-density areas were noted in the brain on follow-up CT 1 week later. We speculated that placing the epidural drain on active suction may have caused an acute decrease in intracranial pressure and subsequent rapid expansion of the brain, which impaired autoregulation and led to reperfusion injury.

Effect of Anti-Alzheimer's disease by Jeonmaedan in CT105-overexpressed SK-N-SH cell lines (CT105로 유도된 인간신경아세포종 세포주에서 전매단의 항치매 효과)

  • Song Ho-Sang;Park Chi-Sang;Park Chang-Gook
    • Herbal Formula Science
    • /
    • v.11 no.2
    • /
    • pp.95-110
    • /
    • 2003
  • Alzheimer's disease(AD) is a geriatric dementia that is widespread in old age. In the near future AD will be the biggest problem in public health service. Although a variety of oriental prescriptions in study Jeonmaedan have been traditionally utilized for the treatment of AD, their pharmacological effects and action mechanisms have not yet fully elucidated. It has been widely believed that A${\beta}$ peptide devided from APP causes apoptotic neurotoxicity in AD brain. However, recent evidence suggests that CTl05(carboxy terminal 105 amino acid peptide fragment of APP) may be an important factor causing neurotoxicity in AD. In addition, AD is one of brain degeneration disease. So we studied on herbal medicine that have a relation of brain degeneration. In Oriental Medicine, Jeonmaedan has been used for disease in relation to brain degeneration. As the result of this study, in Jeonmaedan the apoptosis in the nervous system is inhibited, the repair against the degerneration of SK-N-SH cell lines by CT105 expression is promoted. So Jeonmaedan may be beneficial for the treatment of AD.

  • PDF

Enhancing Medical Images by New Fuzzy Membership Function Median Based Noise Detection and Filtering Technique

  • Elaiyaraja, G.;Kumaratharan, N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2197-2204
    • /
    • 2015
  • In recent years, medical image diagnosis has growing significant momentous in the medicinal field. Brain and lung image of patient are distorted with salt and pepper noise is caused by moving the head and chest during scanning process of patients. Reconstruction of these images is a most significant field of diagnostic evaluation and is produced clearly through techniques such as linear or non-linear filtering. However, restored images are produced with smaller amount of noise reduction in the presence of huge magnitude of salt and pepper noises. To eliminate the high density of salt and pepper noises from the reproduction of images, a new efficient fuzzy based median filtering algorithm with a moderate elapsed time is proposed in this paper. Reproduction image results show enhanced performance for the proposed algorithm over other available noise reduction filtering techniques in terms of peak signal -to -noise ratio (PSNR), mean square error (MSE), root mean square error (RMSE), mean absolute error (MAE), image enhancement factor (IMF) and structural similarity (SSIM) value when tested on different medical images like magnetic resonance imaging (MRI) and computer tomography (CT) scan brain image and CT scan lung image. The introduced algorithm is switching filter that recognize the noise pixels and then corrects them by using median filter with fuzzy two-sided π- membership function for extracting the local information.

Research on Perfusion CT in Rabbit Brain Tumor Model (토끼 뇌종양 모델에서의 관류 CT 영상에 관한 연구)

  • Ha, Bon-Chul;Kwak, Byung-Kook;Jung, Ji-Sung;Lim, Cheong-Hwan;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.165-172
    • /
    • 2012
  • We investigated the vascular characteristics of tumors and normal tissue using perfusion CT in the rabbit brain tumor model. The VX2 carcinoma concentration of $1{\times}10^7$ cells/ml(0.1ml) was implanted in the brain of nine New Zealand white rabbits (weight: 2.4kg-3.0kg, mean: 2.6kg). The perfusion CT was scanned when the tumors were grown up to 5mm. The tumor volume and perfusion value were quantitatively analyzed by using commercial workstation (advantage windows workstation, AW, version 4.2, GE, USA). The mean volume of implanted tumors was $316{\pm}181mm^3$, and the biggest and smallest volumes of tumor were 497 $mm^3$ and 195 $mm^3$, respectively. All the implanted tumors in rabbits are single-nodular tumors, and intracranial metastasis was not observed. In the perfusion CT, cerebral blood volume (CBV) were $74.40{\pm}9.63$, $16.08{\pm}0.64$, $15.24{\pm}3.23$ ml/100g in the tumor core, ipsilateral normal brain, and contralateral normal brain, respectively ($p{\leqq}0.05$). In the cerebral blood flow (CBF), there were significant differences between the tumor core and both normal brains ($p{\leqq}0.05$), but no significant differences between ipsilateral and contralateral normal brains ($962.91{\pm}75.96$ vs. $357.82{\pm}12.82$ vs. $323.19{\pm}83.24$ ml/100g/min). In the mean transit time (MTT), there were significant differences between the tumor core and both normal brains ($p{\leqq}0.05$), but no significant differences between ipsilateral and contralateral normal brains ($4.37{\pm}0.19$ vs. $3.02{\pm}0.41$ vs. $2.86{\pm}0.22$ sec). In the permeability surface (PS), there were significant differences among the tumor core, ipsilateral and contralateral normal brains ($47.23{\pm}25.45$ vs. $14.54{\pm}1.60$ vs. $6.81{\pm}4.20$ ml/100g/min)($p{\leqq}0.05$). In the time to peak (TTP) were no significant differences among the tumor core, ipsilateral and contralateral normal brains. In the positive enhancement integral (PEI), there were significant differences among the tumor core, ipsilateral and contralateral brains ($61.56{\pm}16.07$ vs. $12.58{\pm}2.61$ vs. $8.26{\pm}5.55$ ml/100g). ($p{\leqq}0.05$). In the maximum slope of increase (MSI), there were significant differences between the tumor core and both normal brain($p{\leqq}0.05$), but no significant differences between ipsilateral and contralateral normal brains ($13.18{\pm}2.81$ vs. $6.99{\pm}1.73$ vs. $6.41{\pm}1.39$ HU/sec). Additionally, in the maximum slope of decrease (MSD), there were significant differences between the tumor core and contralateral normal brain($p{\leqq}0.05$), but no significant differences between the tumor core and ipsilateral normal brain($4.02{\pm}1.37$ vs. $4.66{\pm}0.83$ vs. $6.47{\pm}1.53$ HU/sec). In conclusion, the VX2 tumors were implanted in the rabbit brain successfully, and stereotactic inoculation method make single-nodular type of tumor that was no metastasis in intracranial, suitable for comparative study between tumors and normal tissues. Therefore, perfusion CT would be a useful diagnostic tool capable of reflecting the vascularity of the tumors.