• 제목/요약/키워드: Brachytherapy

검색결과 224건 처리시간 0.129초

관동맥혈관 내 방사선 근접 치료: 치료 방법의 비교와 선택 (Options in Intracoronary Radiation Therapy)

  • 문대혁;오승준;이희경;이병용;김은희;박성욱
    • 대한핵의학회:학술대회논문집
    • /
    • /
    • pp.209-221
    • /
    • 1999
  • Coronary restenosis is still regarded as Achilles' Hill of interventional cardiology despite relentless efforts of many investigators. Recent experimental and clinical studies have suggested that both gamma and beta radiation can reduce restenosis after angioplasty. Currently, intracoronary brachytherapy for the prevention of restenosis has become a new evolving treatment modality in interventional cardiology. This report discusses a physical aspect of gamma and beta radiation, initial clinical results and delivery systems used in intracoronary brachytherapy. We shall take a brief overview of methods and their advantages in intra-coronary brachytherapy. Future work should provide further insight for the best way of treating restenosis.

  • PDF

반려견 팬텀에서 유방암 근접방사선치료 시 흡수선량 평가 (Evaluation Absorbed Dose During the Breast Cancer Brachytherapy in Canine Phantom)

  • 김정훈;이득희
    • 한국방사선학회논문지
    • /
    • v.14 no.5
    • /
    • pp.523-528
    • /
    • 2020
  • 반려견의 사망원인 1위인 암 중 암컷에게서 가장 높은 발생률을 보이는 유방암을 대상으로 근접방사선치료 수행 시 모의모사를 이용한 흡수선량 측정을 바탕으로 적용성을 평가하고자 하였다. 모의모사를 위해 MCNPX 프로그램을 이용하였으며, 흡수선량 측정을 위해 소형견 크기의 수학적 팬텀을 제작 하였다. 흡수선량 측정결과 종양의 경우 192Ir에서 1.02E-12 Gy/#으로 흡수선량이 가장 높은 것으로 나타났으며, 내·외부 흡수선량에서도 동일한 경향성으로 나타났다. 따라서 반려견 유방암의 근접방사선치료 시 견종과 피폭을 고려한 적절한 선원의 선택이 고려되어야 될 것이다.

혈관내 방사선치료를 위한 이론적 선원 설계 및 선량적 관점에서의 적합성 연구: 출력변조를 이용한 근접치료에 대한 제안 (Conceptual Source Design and Dosimetric Feasibility Study for Intravascular Treatment: A Proposal for Intensity Modulated Brachytherapy)

  • 김시용;한은영;;하성환
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.158-166
    • /
    • 2003
  • 목적: 본 연구는 새로운 근접치료선원의 이론적 설계를 통해 출력변조를 이용한 혈관내 방사선치료를 제안한다. 대상 및 방법: 제시된 이론적 선원은 기존의 선원과는 달리 선원물질과 차폐물질(스테인리스 스틸, 또는 텅스텐) 둘 다로 구성되며 이는 방위방향으로 비대칭적 방사선량을 제공할 수 있게 한다. 따라서, 방위방향으로 선원의 방향과 체류시간을 조절함으로써 출력변조를 통한 근접치료가 가능해진다. Novoste Beta-Cath system에서 사용하는 Sr-90/Y 전자방출 선원과 유사한 모양의 두 가지 단순화한 선원을 연구의 대상으로 고려하였다. 첫 번째 선원은 선원물질과 차폐물질이 각각 반씩 차지하며, 두 번째 선원은 1/4은 선원물질로, 나머지 3/4은 차폐물질로 구성된다. 두 선원에 대해 방위 및 방사방향으로의 선량분포를 MCNP 몬테 카를로 코드를 이용하여 계산하였다. 결과: 선원이 혈관내의 중심에 위치하지 않게 되는 가상조건에서의 선량 최적화 계산을 시도한 결과, 혈관내벽에 미치는 선량의 최고치와 최저치의 차이가 87$\%$에서 7$\%$까지 줄어들 수 있음을 보였다. 결론: 본 연구에서 제시된 이론적 선원은 선량적 관점에서의 적합성 여부에 관해 매우 고무적인 결과를 보여 줌으로써 출력변조를 통한 혈관내 근접방사선치료의 가능성을 나타내었다. 본 과제의 다음 단계는 굵기가 가는 맥관 내에서 선원의 위치를 파악하여 그를 방위방향으로 정확하게 회전시킬 수 있는 방사선 전달 체계의 개발이라 할 수 있다.

원격전이의 증거가 없는 식도암의 방사선치료 성적 (Result of Radiotherapy in Non-metastatic Esophageal Cancer)

  • 채규영;장정순;이종석
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.27-31
    • /
    • 1995
  • Purpose : This study was done to evaluate preliminarily the role of intraluminal brachytherapy in the radiation treatment of non-metastatic esophageal cancer, Materials and Methods: We analyzed follow-up result of 21 patients treated at the dept. of therapeutic radiology in Gyeongsang national university hospital between April, 1989 and August, 1992. All patients received neoadjuvant chemotherapy(5-FU, Cispl-atin). Fifteen Patients were treated with external beam alone, and in remaining 6 patients, the external beam radiotherapy followed by intraluminal brachytherapy was done. Results : Among 21 patients, 7 patients showed complete tumor regression after completion of radiotherapy. But 2 of these complete responder recurred at the site of primary disease, so ultimate local control rate was $23.8\%$(5/21). Local control rate according to radiation treatment modality was $6.7\%$(1/15) in patients treaed with external irradiation only, and $66.7\%$ in patients treated with combined external irradiation and intraluminal brachytherapy. The 2 year NED survival rate was $6.6.\%$ in the former and $66.7\%$ in the latter. Conclusion: Although there should be consideration about case selection for addition of intraluminal brachytherapy intraluminal brachytherapy may be considerded as one of the method to enhance the local control probability of esophageal cancer.

  • PDF

Development of a Pelvic Phantom for Dose Verification in High Dose Rate (HDR) Brachytherapy

  • Jang, Ji-Na;Suh, Tae-Suk;Huh, Soon-Nyung;Kim, Hoi-Nam;Yoon, Sei-Chul;Lee, Hyoung-Koo;Choe, Bo-Young
    • 한국의학물리학회:학술대회논문집
    • /
    • /
    • pp.150-153
    • /
    • 2002
  • High dose rate (HDR) brachytherapy in the treatment of cervix carcinoma has become popular, because it eliminated many of the problems with conventional brachytherapy. In order to improve clinical effectiveness with HDR brachytherapy, dose calculation algorithm, optimization procedures, and image registrations should be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom irradiated. Therefore, the humanoid phantom should be designed such that the dose distributions could be quantitatively evaluated by utilizing the dosimeters with high spatial resolution. Therefore, the small size of thermoluminescent dosimeter (TLD) chips with the dimension of 1/8" and film dosimetry with spatial resolution of <1mm used to measure the radiation dosages in the phantom. The humanoid phantom called a pelvic phantom is made of water and tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators are inserted into the grooves of the applicator supporters. The dose distributions around the applicators, such as Point A and B, can be measured by placing a series of TLD chips (TLD-to- TLD distance: 5mm) in three TLD holders, and placing three verification films in orthogonal planes.

  • PDF

Vaginal Dose, Toxicity and Sexual Outcomes in Patients of Cervical Cancer Undergoing Image Based Brachytherapy

  • Rai, Bhavana;Dhanireddy, Bhaswanth;Patel, Firuza Darius;Kumari, Reena;Oinam, Arun Singh;Simha, Vijai;Sharma, Suresh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3619-3623
    • /
    • 2014
  • Background: The aim of the study was to evaluate the vaginal dose and toxicity in patients of cervical cancer treated with image guided brachytherapy at our institute. Materials and Methods: Thirty-five patients treated with image based brachytherapy for cervical cancer were included. Vaginal contouring was done on MRI at brachytherapy and with CT scans of subsequent brachytherapy fractions. Dose volume parameters (DVH) were reported in accordance with the GEC-ESTRO guidelines. These were correlated with vaginal toxicity (assessed by CTCAE version 3) and quality of sexual life assessed at one year of completion of treatment. Results: Vaginal shortness was observed in 22 out of 30 (62.8%) patients, Nine (25.7%) had vaginal dryness and in 10 (28.5%) patients, there was contact bleeding. No association could be demonstrated between the dose volume parameters and vaginal toxicity in the present study. Conclusions: The lack of association between dose volume parameters of vagina with vaginal morbidity may be due to uncertainties involved in the delineation of vaginal wall and dosimetry. Future research is required to accurately define vaginal dose distribution to study its correlation with vaginal morbidity. Vaginal morbidity needs to be documented in order to improve the sexual outcome in these patients.

Clinical outcome of high-dose-rate interstitial brachytherapy in patients with oral cavity cancer

  • Lee, Sung Uk;Cho, Kwan Ho;Moon, Sung Ho;Choi, Sung Weon;Park, Joo Yong;Yun, Tak;Lee, Sang Hyun;Lim, Young Kyung;Jeong, Chi Young
    • Radiation Oncology Journal
    • /
    • v.32 no.4
    • /
    • pp.238-246
    • /
    • 2014
  • Purpose: To evaluate the clinical outcome of high-dose-rate (HDR) interstitial brachytherapy (IBT) in patients with oral cavity cancer. Materials and Methods: Sixteen patients with oral cavity cancer treated with HDR remote-control afterloading brachytherapy using $^{192}Ir$ between 2001 and 2013 were analyzed retrospectively. Brachytherapy was administered in 11 patients as the primary treatment and in five patients as salvage treatment for recurrence after the initial surgery. In 12 patients, external beam radiotherapy (50-55 Gy/25 fractions) was combined with IBT of 21 Gy/7 fractions. In addition, IBT was administered as the sole treatment in three patients with a total dose of 50 Gy/10 fractions and as postoperative adjuvant treatment in one patient with a total of 35 Gy/7 fractions. Results: The 5-year overall survival of the entire group was 70%. The actuarial local control rate after 3 years was 84%. All five recurrent cases after initial surgery were successfully salvaged using IBT ${\pm}$ external beam radiotherapy. Two patients developed local recurrence at 3 and 5 months, respectively, after IBT. The acute complications were acceptable (${\leq}grade$ 2). Three patients developed major late complications, such as radio-osteonecrosis, in which one patient was treated by conservative therapy and two required surgical intervention. Conclusion: HDR IBT for oral cavity cancer was effective and acceptable in diverse clinical settings, such as in the cases of primary or salvage treatment.

악성 기도 폐쇄에 대한 기관내 근접 조사 방사선치료의 단기 임상 경험 (Short-term Results of Endobronchial Brachytherapy for Malignant Airway Obstructions)

  • 안용찬;임도훈;최동락;김문경;김대용;허승재;김호중;정만표;권오정;이종헌
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.299-306
    • /
    • 1996
  • 목적 : 주요 기도의 악성 종양으로 인한 호흡기 증상은 적절한 조치를 취하지 않을 경우 때로는 환자의 생명을 위협할 정도로 위급한 경우가 있으며 환자의 삶의 질을 저하시키는 주요 원인이 된다. 이러한 호흡기 증상의 완화를 위하여 적용한 기관지 내시경을 이용한 고선량율 기관내 근접 조사 방사선차료의 단기 임상 관찰 결과를 보고하고자 한다. 대상 및 방법 : 1994년 12월부터 1996년 3월까지 원발성 또는 전이성 폐암으로 인한 기도폐쇄 와 이로 인한 주요 호흡기 증상이 있는 25명의 환자들에 대하여 고선량율 기관내 근접 조사 방사선치료를 시술하였다. 원발 병소는 비소세포성 폐암이 21례 ($84\%$), 원발성 기관암이 3례($12\%$), 재발된 식도암이 1례였다. 20명의 환자들에 대하여는 외부 조사 방사선치료를 병행하였으며, 급성 기도 폐쇄로 위급한 증상을 호소하였던 6명의 환자에 대하여는 응급 기관내 Laser 소작술을 먼저 시행하였다. 기관내 근접 조사 방사선치료는 모든 환자에서 각 3회씩 시행하도록 예정하였으며 모두 70회의 치료를 시행하였다. 결과 : 기관내 근접 조사 방사선치료의 전후로 조사한 주요 호흡기 증상은 기침, 호흡곤란, 각혈, 폐쇄성 폐렴이 각각 $88\%$ (22/25), $96\%$ (22/23), $100\%$ (15/15), $100\%$ (9/9)에서 호전되었으며, 환자의 일반 활동도 (ECOG performance score)는 전체 환자의 $56\%$에서 호전되었고 악화된 경우는 없었다. 관찰 기간 동안 15명이 사망하였으며 치료 개시로부터 사망까지 기간의 중앙값은 4개월 (범위: 1개월$\~$17개월) 이었고 10명의 생존자들의 생존 기간의 중앙값은 9개월 (범위: 5개월$\~$19개월)이었다. 치료 후 1년 이상 생존한 환자는 5명이었으며 이들 모두에선 원발 병소의 완전 관해를 확인할 수 있었다. 사망자들은 모두 원발 및 전이 병소의 진행으로 인한 경우였다. 대량 각혈로 사망한 경우는 4명이었으며 이 중 3명은 응급 기관내 Laser 소작술을 선행하였던 경우였다. 결론 : 기관지 내시경을 이용한 기관내 근접 조사 방사선 치료는 기도의 악성 병변시 호흡기 증상 및 환자의 활동도를 호전시키는 데 매우 효과적인 치료 방법이다. 저자들의 관찰 경험을 바탕으로 하여 기관내 근접 조사 방사선치료는 근치적 방사선치료의 국소 추가 방사선 조사의 한 방법으로 적용할 수 있을 것으로 판단된다.

  • PDF

국산 근접치료용 Ir-192 선원의 개발 및 실용화 동향 (Development and Application of Ir-192 Brachytherapy Source in Korea)

  • 손광재;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • v.23 no.4
    • /
    • pp.326-332
    • /
    • 2012
  • 최근 전 세계적인 원자로 시설의 감축으로 인한 수입 치료용 동위원소의 가격 상승으로 인하여 의료기관에서 근접치료기 운영에 문제가 되고 있다. 본 보고서에서는 국내에서 생산한 두 종류 Ir-192 선원(직경 4.5 mm와 1.1 mm)의 개발 과정과 기술 동향 대하여 제시하였다. 이 보고서의 내용이 근접치료기를 운영하는 의료기관에서 정책 수립에 도움이 되기를 바란다.

Personal computer를 이용한 자궁경부암의 고선량을 강내치료 계획 (Treatment Planning Software for High Dose Rate Remote Afterloading Brachytherapy of Uterine Cervical Cancer)

  • 허승재;강위생
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.183-186
    • /
    • 1986
  • 고선량율을 이용한 자궁강내 치료시 정확하고 신속한 계산을 위하여 저자들은 개인용 컴퓨터를 이용하여 기준점의 선량분포 및 방사선조사 시간을 간편하게 계산할 수 있는 software를 개발하였다. 치료 계획용 software를 이용하여 짧은 시간내에 선량 분포 및 조사시간을 용이하고 정확하게 계산할 수 있으며, 고선량을 자궁경부암 임상적응에 효과적으로 이용할 수 있어서 보고한다.

  • PDF