• Title/Summary/Keyword: Bovine toxoplasmosis

Search Result 2, Processing Time 0.017 seconds

Server on the Distribution of Bovine Toxoplasma Antubodies by Latex Agglutination Test in Gyeongnam District (경남지역에서의 Latex응집반응을 이용한 소 톡소플라즈마 항체분포 조사)

  • 이병훈;류중운;황보원;변유성;조광제
    • Korean Journal of Veterinary Service
    • /
    • v.18 no.3
    • /
    • pp.36-41
    • /
    • 1995
  • This study was conducted to determine the serum antibodies against toxoplasma in bovine from gyeongnam district by latex agglutination(LA) test. LA test was carried out with Toxo-MT kit(Eikon chemical co). The result obtained were summerized as follow: 1. Positive rates of toxoplasma antibodies in 1,488 bovine sera was 5.0%(75 cases) by LA test. 2. The toxoplasma antibody detection rates against 823 korean cattle and 865 dairy cattle were 1.8%(11 cases) and 7.4%(64 cases) respectively. 3. In LA test serum antibody titers in 75 positive sera were shown as 54 cases(72.0% in 1:32, 9(12.0%) in 1:64, 7(9.4%) in 1:128, 3(3.40%) in 1:256, 1(1.3%) in 512 and 1(1.3%) in 1:2,048 respectively. 4. Positive rates of toxoplasma antibodies in cattls sera from each area were 0.2∼22.0%.

  • PDF

Development of diagnostic kit(Test-MT) for the microplate latex agglutination test of toxoplasmosis in animal (Latex 응집반응을 이용한 동물의 톡소플라즈마병 진단용 kit 개발에 관한 연구)

  • Suh, Myung-deuk;Joo, Hoo-don;Maass, Daivd
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.3
    • /
    • pp.583-593
    • /
    • 1995
  • The present study was conducted to develop a toxoplasma latex agglutination test antigen(Test-MT) and evaluate the toxoplasma latex agglutination(LA) test using a newly-made "Test-MT kit" by comparing with the Toxo-MT kit(Eiken chemical co, Tokyo). Also, the specifity and sensitivity test were made by comparing with IFA test and IgG-ELISA. Tachyzoite suspensions of Toxoplasma gondii(RH strain) were ultracentrifuged for 30min at $60,000{\times}g(4^{\circ}C)$ and the supernatant was used as a water-lysate antigen. Polystyrene latex particles of $1.0{\mu}m$ in diameter(Polyscience co) were used for the preparation of sensitized latex-antigen supension(Test-MT). The frequency distribution of LA titers in Test-MT showed two peaks at <1:32 and 1:128. The borderline titer for positive test in Test-MT was determined to be 1:64. But the frequency distribution of LA tites in Toxo-MT showed two peaks at <1:16 and 1:64. The positive borderline was determined to be 1:32. Agreement of reactions between Test-MT and Toxo-MT kit by LA test was shown 92.5% in bovine sera and 97.0% in swine sera, respectively. From the results obtained here it was determined that the sensitized latex-antigen, Test-MT kit, for the microtiter agglutination test prepared as same as by the procedure described in the previous paper(Suh and Lee, 1993) was useful as a highly specific, sensitive and stable immunotiteration reagent for serodiagnosis of toxoplasma infection in animal sera.

  • PDF