• Title/Summary/Keyword: Boundary Curve

Search Result 366, Processing Time 0.026 seconds

Buckling resistance behavior of WGJ420 fire-resistant weathering steel columns under fire

  • Yiran Wu;Xianglin Yu;Yongjiu Shi;Yonglei Xu;Huiyong Ban
    • Steel and Composite Structures
    • /
    • v.47 no.2
    • /
    • pp.269-287
    • /
    • 2023
  • The WGJ420 fire-resistant weathering (FRW) steel is developed and manufactured with standard yield strength of 420 MPa at room temperature, which is expected to significantly enhance the performance of steel structures with excellent fire and corrosion resistances, strong seismic capacity, high strength and ductility, good resilience and robustness. In this paper, the mechanical properties of FRW steel plates and buckling behavior of columns are investigated through tests at elevated temperatures. The stress-strain curves, mechanical properties of FRW steel such as modulus of elasticity, proof strength, tensile strength, as well as corresponding reduction factors are obtained and discussed. The recommended constitutive model based on the Ramberg-Osgood relationship, as well as the relevant formulas for mechanical properties are proposed, which provide fundamental mechanical parameters and references. A total of 12 FRW steel welded I-section columns with different slenderness ratios and buckling load ratios are tested under standard fire to understand the global buckling behavior in-depth. The influences of boundary conditions on the buckling failure modes as well as the critical temperatures are also investigated. In addition, the temperature distributions at different sections/locations of the columns are obtained. It is found that the buckling deformation curve can be divided into four stages: initial expansion stage, stable stage, compression stage and failure stage. The fire test results concluded that the residual buckling capacities of FRW steel columns are substantially higher than the conventional steel columns at elevated temperatures. Furthermore, the numerical results show good agreement with the fire test results in terms of the critical temperature and maximum axial elongation. Finally, the critical temperatures between the numerical results and various code/standard curves (GB 51249, Eurocode 3, AS 4100, BS 5950 and AISC) are compared and verified both in the buckling resistance domain and in the temperature domain. It is demonstrated that the FRW steel columns have sufficient safety redundancy for fire resistance when they are designed according to current codes or standards.

Strongest Simple Beams with Constant Volume (일정체적 단순지지 최강보)

  • Lee, Byoung Koo;Lee, Tae Eun;Kim, Young Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.2A
    • /
    • pp.155-162
    • /
    • 2009
  • This paper deals with the strongest beams with the solid regular polygon cross-section, whose volumes are always held constant. The differential equation of the elastic deflection curve of such beam subjected to the concentrated and trapezoidal distributed loads are derived and solved numerically. The Runge-Kutta method and shooting method are used to integrate the differential equation and to determine the unknown initial boundary condition of the given beam. In the numerical examples, the simple beams are considered as the end constraint and also, the linear, parabolic and sinusoidal tapers are considered as the shape function of cross sectional depth. As the numerical results, the configurations, i.e. section ratios, of the strongest beams are determined by reading the section ratios from the numerical data related with the static behaviors, under which static maximum behaviors become to be minimum.

Development and Verification of a Large Scale Resonant Column Testing System (대형 공진주시험기의 개발 및 검증)

  • Kim, Nam-Ryong;Ha, Ik-Soo;Shin, Dong-Hoon;Kim, Min-Seub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6C
    • /
    • pp.295-304
    • /
    • 2012
  • In this study, a resonant column testing system which is the largest in Korea has been developed to evaluate the dynamic deformation characteristics of coarse granular geomaterials, and the performance and the applicability of the testing system have been verified. The system has been developed as a typical Stokoe type device whose boundary conditions are fixed bottom and free top with additional mass, and can adopt a large specimen with 200 mm in diameter and 400 mm in height. The driving and measurement instruments are configured as high performance and precision systems, hence the automated testing system is appropriate to drive enough stress and to measure the behavior precisely for the test in practical manner. The dynamic response of the mechanical components and the applicability of the system have been evaluated using metal specimens as well as polyurethane specimens, and its precision was verified by comparing its results with those from other equipment and/or methods. To confirm the applicability of the large system for coarse geomaterials, the resonant column test results from both large and normal scale apparatus for the same material were compared and it was found that the result can be partially affected by scale. Finally, the dynamic deformation characteristics of coarse geomaterial which is used for construction of large dam was evaluated using the large system and its practicality could be confirmed.

Bearing Capacity of a Monopod Bucket Foundation for Offshore Wind Towers - Centrifuge and Numerical Modeling (해상풍력 모노포드 버켓기초의 지지력 거동 - 원심모형실험 및 수치해석)

  • Kim, Dong-Joon;Choo, Yun Wook;Kim, Surin;Kim, Jae-Hyun;Choi, Ho-Young;Kim, Dong-Soo;Lee, Man-Soo;Park, Yung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.4
    • /
    • pp.23-32
    • /
    • 2013
  • In order to evaluate the bearing capacity behaviour of a monopod suction bucket foundation for an offshore wind tower at the western sea of Korea, a centrifuge load test and numerical analyses were performed. The monopod bucket foundation was designed to be installed in a silty sand layer. The model soil was prepared to simulate a target site by using soil samples having similar properties and controlling relative density. In-flight miniature cone penetration test and bender element array were used to confirm that the model soil had represented the target site conditions. The load - rotation curve of the centrifuge load test was analysed. A series of numerical analyses were performed to validate the experimental conditions. Self-weight of the model, distance to the boundary and elastic modulus of the soil layer were varied to study their effects on the load - rotation curves.

Numerical Analysis of the Prediction of Zincate Concentration at a Zinc Electrode with Electrolyte Flow Conditions in a Zinc Air Fuel Cell (전해질 유동 조건에 따른 아연공기전지 아연극 표면의 Zincate 이온 농도 예측을 위한 수치해석적 연구)

  • Kim, Jung-Yun;Lee, Ho-Il;Oh, Tae-Young;Park, Sang-Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.4
    • /
    • pp.231-238
    • /
    • 2011
  • In this work, the numerical analysis for the zincate behavior at a zinc electrode with an electrolyte flow was carried out for a ZAFC. The Nernst-Planck equation with a boundary condition of Butler-Volmer type was adopted to describe electrochemical effects of mass transfer, migration, kinetics of electrode. The Navier-Stokes equation, coupling to the Nernst-Planck equation, is also applied to describe the internal electrolyte flow fields. The validity of the numerical model is proved through the comparative analysis between numerical and experimental results. The concentration of zincate and the current density were also investigated at a zinc anode according to various electrolyte velocities. We have found the concentration of zincate decreased and the current density increased with an increase in the electrolyte velocity.

A feasibility modeling of potential dam site for hydroelectricity based on ASTGTM DEM data (ASTGTM 전지구 DEM 기반의 수력발전댐 적지분석 사전모델링)

  • Jang, Wonjin;Lee, Yonggwan;Kim, Seongjoon
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.7
    • /
    • pp.545-555
    • /
    • 2020
  • A feasibility modeling for potential hydroelectric dam site selection was suggested using 1 sec ASTGTM (ASTER Global Digital Elevation Model) and Terra/Aqua MODIS (Moderate Resolution Imaging Spectroradiometer) derived land use (MCD12Q1) data. The modeling includes DEM pre-processing of peak, sink, and flat, river network generation, watershed delineation and segmentation, terrain analysis of stream cross section and reservoir storage, and estimation of submerged area for compensation. The modeling algorithms were developed using Python and as an open source GIS. When a user-defined stream point is selected, the model evaluates potential hydroelectric head, reservoir surface area and storage capacity curve, watershed time of concentration from DEM, and compensation area from land use data. The model was tested for 4 locations of already constructed Buhang, BohyunMountain, Sungdeok, and Yeongju dams. The modeling results obtained maximum possible heads of 37.0, 67.0, 73.0, 42.0 m, surface areas of 1.81, 2.4, 2.8, 8.8 ㎢, storages of 35.9, 68.0, 91.3, 168.3×106 ㎥ respectively. BohyunMountain and Sungdeok show validity but in case of Buhang and Yeongju dams have maximum head errors. These errors came from the stream generation error due to ASTGTM. So, wrong dam watershed boundary limit the head. This study showed a possibility to estimate potential hydroelectric dam sites before field investigation especially for overseas project.

A numerical study on the characteristics of the smoke movement and the effects of structure in road tunnel fire (도로터널 화재시 연기의 전파특성과 구조체에 미치는 영향에 관한 수치 해석적 연구)

  • Yoo, Ji-Oh;Oh, Byung-Chil;Kim, Hyo-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.289-300
    • /
    • 2013
  • This study numerically considered the characteristic of smoke movement and the effect of hot smoke gas on tunnel wall surface temperature during road tunnel fire under boundary condition of fire growth curve that is applied to fire analysis in road tunnels. The maximum heat release rate were 20 MW and 100 MW and tunnel air velocities were 2.5 m/s and velocity induced by thermal buoyancy respectively, also the cooling effect of tunnel wall was considered. As results, when tunnel air velocity was constant at 2.5 m/s during tunnel fire, due to the cooling effect of tunnel wall, the smoke layer was rapidly descent after some distance and it flowed the same patterns at the downstream. When heat release rate was 100 MW (and jet fan was not installed), the maximum temperature of tunnel wall surface has risen up to $615^{\circ}C$. The heat transfer coefficient of tunnel wall surface was varied from 13 to $23W/m^2^{\circ}C$ approximately.

3D SH-wave Velocity Structure of East Asia using Love-Wave Tomography and Implication on Radial Anisotropy (러브파 토모그래피를 이용한 동아시아의 3차원 SH파 속도구조와 이방성 연구)

  • Min, Kyungmin;Chang, Sung-Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.1
    • /
    • pp.25-32
    • /
    • 2017
  • We present a 3D SH-wave velocity model of the crust and uppermost mantle and seismic radial anisotropy beneath East Asia. The SH-wave velocity structure model was built using Love-wave group-velocity dispersion data from earthquake data recorded at broadband seismic networks of Korea, Japan, and China. Love-wave group-velocity dispersion curves were obtained by using the multiple filtering technique in the period range of 3 to 150 s for 3,369 event-station pairs. The inverted model using these data sets provides a crust and upper mantle SH-wave velocity structure down to 100 km depth. At 10 ~ 40 km depths SH-wave velocity beneath the East Sea is higher than beneath the Japanese island region. We estimated the Moho beneath the East Sea to be between 10 ~ 20 km depth, while Moho beneath the Korean Peninsula at around 35 km based on the depth where high-velocity anomalies are detected. We estimated the lithosphere-asthenosphere boundary beneath the East Sea to be at around 50 km based on the depth where strong low-velocity anomalies are observed. Widespread low-velocity anomalies are found between 50 ~ 100 km depth in the study region. Positive radial anisotropy ($V_{SV}$ > $V _{SH}$) is observed down to 35 km depth, while negative radial anisotropy ($V_{SV}$ > $V _{SH}$) is observed for deeper depth.

Gas Sensing Properties and Mechanism of the $\textrm{SnO}_2-\textrm{In}_2\textrm{O}_3$ System Prepared by Coprecipitation Method (공침법으로 제조된 $\textrm{SnO}_2-\textrm{In}_2\textrm{O}_3$ 계의 가스감응특성 및 감응기구)

  • Yun, Gi-Hyeon;Im, Ho-Yeon;Gwon, Cheol-Han;Yun, Dong-Hyeon;Kim, Seung-Ryeol;Hong, Hyeong-Gi;Lee, Gyu-Jeong
    • Korean Journal of Materials Research
    • /
    • v.8 no.9
    • /
    • pp.813-818
    • /
    • 1998
  • Ultrafine powders of $\textrm{In}_{2}\textrm{O}_{3}$-doped $\textrm{SnO}_{2}$ were synthesized by a coprecipitation method and the effects of pH value and the amount of In2Q addition on particle size were investigated. The influence of pH value on particle size could be negligible, whereas the amount of $\textrm{In}_{2}\textrm{O}_{3}$ has influenced on particle size and specific surface area. The gas sensitivity to hydrocarbOn($\textrm{C}_{3}\textrm{H}_{8}$, $\textrm{C}_{4}\textrm{H}_{10}$) increased with $\textrm{In}_{2}\textrm{O}_{3}$ addition and reached a maximum at 3wt.% addition. From the results of impedance analysis and I-V characteristics. it was showed that the agglomeration structure of particles and the boundaries between agglomerates were the important factors to determine the gas sensing mechanism.

  • PDF

A Study on Static Behavior of 60 m span Half-Decked PSC Girder (Half-Deck을 포함한 60 m 경간 PS 콘크리트거더의 정적 거동 연구)

  • Kim, Tae Min;Park, Jong Heon;Kim, Moon Kyum;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.65-73
    • /
    • 2012
  • In this study, we tested structural performance of Half-Decked PSC girder which was developed for applying to long span bridge. We operated 4 point bending test with 60 m span full scale girder designed as simple bridge with hinge-roller boundary condition. Actuators were set on the both sides of girder, 5.5 m away from the center, and 4 stages of cyclic loading was applied at rate of 1 kN/sec. Through stages 1 to 4, loading and unloading 1,000 kN, 1,200 kN, 1,500 kN, and 2,000 kN were repeated and displacement, strain of concrete and steel, crack of girder were checked. From these results, the strength of girder was assessed and resilience and ductility were observed after removing the load. Since initial flexural crack occurred in the vicinity of 1,400 kN, non-linearity of load-displacement curve appeared and definite residual strain was measured at that point. The test result showed that initial cracking load was over twice the DB-24 load which means the developed girder had sufficient strength. To verify the experimental results, we numerically analyze the test and confirmed that the data were similar with results from the test above. Half-Decked PSC type of 60 m-girder developed in this study showed its adequate structural capacity through static loading test, which proved that possibility of applying the girder to actual bridges practically.