Application of electromagnetic methods to the investigation of seawater intrusion into coastal aquifer - A case study in the Hasunuma area, Chiba Prefecture, Japan

  • Mitsuhata Yuji;Uchida Toshihiro
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.335-339
    • /
    • 2003
  • The estimation of seawater intrusion into deep aquifers has been becoming an important subject in terms of site characterization for geological disposal of radioactive waste. Conventional direct-current resistivity methods have been used for ground water explorations and recently have been applied to environmental problems. However, electromagnetic methods are more practical and useful for such a deep investigation. We consider audio-frequency magnetotelluric (AMT) and surface-to-borehole electromagnetic (EM) tomography methods as promising tools for the investigation of deep aquifer. These methods were tested in the Hasunuma area, Chiba Prefecture, Japan. Although the study area is in an urban area, high-quality AMT data were acquired, which was mainly accomplished by night-time data recording and remote-reference data processing. One-dimensional inversion results of the AMT data revealed two extremely conductive zones, which is consistent with the electrical conductivity profile of pore water in core samples. It can be interpreted as the seawater intrusions into both zones. However, the chemical analysis of the groundwater sampled in the deep zone suggests that this groundwater must be fossil seawater that had been confined during sedimentation processes. In addition, the permeability coefficient of the deep layer is very low. Thus the deep conductive zone corresponds to the fossil seawater regarded as being difficult to flow.

  • PDF

Efficient crosswell EM Tomography using localized nonlinear approximation

  • Kim Hee Joon;Song Yoonho;Lee Ki Ha;Wilt Michael J.
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.51-55
    • /
    • 2004
  • This paper presents a fast and stable imaging scheme using the localized nonlinear (LN) approximation of integral equation (IE) solutions for inverting electromagnetic data obtained in a crosswell survey. The medium is assumed to be cylindrically symmetric about a source borehole, and to maintain the symmetry a vertical magnetic dipole is used as a source. To find an optimum balance between data fitting and smoothness constraint, we introduce an automatic selection scheme for a Lagrange multiplier, which is sought at each iteration with a least misfit criterion. In this selection scheme, the IE algorithm is quite attractive for saving computing time because Green's functions, whose calculation is a most time-consuming part in IE methods, are repeatedly re-usable throughout the inversion process. The inversion scheme using the LN approximation has been tested to show its stability and efficiency, using both synthetic and field data. The inverted image derived from the field data, collected in a pilot experiment of water-flood monitoring in an oil field, is successfully compared with that derived by a 2.5-dimensional inversion scheme.

A problem in the cross-hole resistivity method using pole-pole array (단극배열을 이용한 시추공-시추공 전기비저항 탐사법의 문제점)

  • Jo, In Gi;Choe, Gyeong Hwa
    • Journal of the Korean Geophysical Society
    • /
    • v.1 no.1
    • /
    • pp.51-58
    • /
    • 1998
  • A numerical program has been developed to model 2-D resistivity responses for a pole-pole array configuration in cross-hole resistivity measurements. Apparent resistivity and secondary potential were computed using the program for a cylindrical inhomogeneity in an uniform host medium excited by a point source of current in a borehole. Surprisingly apparent resistivity in the receiver hole turns out to be lower than the one of surrounding medium regardless of the conductivity of cylindrical inhomogeneity. Using only cross-hole data, therefore, it is impossible to interpret the conductivity of inhomogeneity. To overcome this problem, 3-D measurement and interpretation are necessary. If 3-D data acquisition is impossible, inline data should be used to get the information about the conductivity of inhomogeneity.

  • PDF

Prediction of Ground Blasting Vibration using Superposition Modeling Data of Single Hole Blasting Waveform (단일공 발파파형 중첩모델링 자료를 이용한 지반 진동의 예측)

  • Kim, Jong-In;Kang, Choo-Won
    • Tunnel and Underground Space
    • /
    • v.17 no.6
    • /
    • pp.484-492
    • /
    • 2007
  • The blasting vibration prediction in the country is mainly carried out by using the scaled distance method. But, this method needs a real-scale test blasting. The blasting vibration prediction has been performed using the data measured at borehole blasting for the purpose of a geological investigation before beginning a construction of a tunnel. In this prediction method, it is difficult to reflect the propagation characteristics of ground vibration generated from a real-scale blasting. propagation. This paper presents a new method for estimating blasting vibration by using superposed data of single hole blasting waveform with a delay time.

Evaluation of Thermal Conductivity for Grout/Soil Formation Using Thermal Response Test and Parameter Estimation Models (열응답 시험과 변수 평가 모델을 이용한 그라우트/토양 혼합층의 열전도도 산정)

  • Sohn Byong Hu;Shin Hyun Jun;An Hyung Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.173-182
    • /
    • 2005
  • The Performance of U-tube ground heat exchanger for geothermal heat Pump systems depends on the thermal properties of the soil, as well as grout or backfill materials in the borehole. In-situ tests provide a means of estimating some of these properties. In this study, in-situ thermal response tests were completed on two vertical boreholes, 130 m deep with 62 mm diameter high density polyethylene U-tubes. The tests were conducted by adding a monitored amount of heat to water over a $17\~18$ hour period for each vertical boreholes. By monitoring the water temperatures entering and exiting the loop and heat load, overall thermal conductivity values of grout/soil formation were determined. Two parameter estimation models for evaluation of thermal response test data were compared when applied on the same temperature response data. One model is based on line-source theory and the other is a numerical one-dimensional finite difference model. The average thermal conductivity deviation between measured data and these models is of the magnitude $1\%$ to $5\%$.

A Fast Inversion Method for Interpreting Single-Hole Electromagnetic Data (단일 시추공 전자탐사 자료 해석을 위한 빠른 역산법)

  • Kim, Hee-Joon;Lee, Jung-Mo
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.316-322
    • /
    • 2002
  • A computationally efficient inversion scheme has been developed using the extended Born or localized nonlinear approximation to analyze electromagnetic fields obtained in a single-hole environment. The medium is assumed to be cylindrically symmetric about the borehole, and to maintain the symmetry vertical magnetic dipole source is used throughout. The efficiency and robustness of an inversion scheme is very much dependent on the proper use of Lagrange multiplier, which is often provided manually to achieve desired convergence. In this study, an automatic Lagrange multiplier selection scheme has been developed to enhance the utility of the inversion scheme in handling field data. The inversion scheme has been tested using synthetic data to show its stability and effectiveness.

Seismic attributes for characterization of a heavy-oil shaly-sand reservoir in the Muglad Basin of South Sudan

  • Deng, William A.;Kim, Taeyoun;Jang, Seonghyung
    • Geosciences Journal
    • /
    • v.22 no.6
    • /
    • pp.1027-1039
    • /
    • 2018
  • Seismic attributes are often used to identify lithology and evaluate reservoir properties. However, interpretation based only on structural attributes and without knowledge of the Vp/Vs ratio can limit the ability to evaluate changes in heavy oil reservoirs. These limitations are often due to less obvious impedance differences. In order to investigate pieces of evidence of a heavy-oil shaly-sand reservoir from seismic data, besides geochemistry, we studied seismic attributes and characterized the reservoir using seismic stack data and well logging data. The study area was the Muglad rift basin in South Sudan. We conducted a seismic complex analysis to evaluate the target reservoir. To delineate the frequency responses of the different lithological units, we applied the spectral decomposition method to the target reservoir. The most unexpected result was continuous bands of strong seismic reflectors in the target reservoir, which extended across the borehole. Spectral decomposition analysis showed that the low-frequency zone of 25 Hz dominant frequency was consistent with instantaneous attributes. This approach can identify lithology, reveal frequency anomalies, and filter the stacked section into low- and high-frequency bands. The heavy-oil reservoir zones exhibited velocity attenuation and the amplitude was strongly frequency dependent.

CHARACTERIZATION OF GEOTECHNICAL SITES BY MULTI-CHANNEL ANALSIS OF SURFACE WAVES(MCASW) (지표층의 탄성계수 측정을 위한 새로운 탄성파 방법)

  • 박춘병
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1995.10a
    • /
    • pp.15.2-22
    • /
    • 1995
  • Evaluating stiffness of near-surface materials has been one of the critically important tasks in many civil engineering works. It is the main goal of geotechnical characterization. The so-called deflection-response method evaluates the stiffness by measuring stress-strain behavior of the materials caused by static or dynamic load. This method, however, evaluates the overall stiffness and the stiffness variation with depth cannot be obtained. Furthermore, evaluation of a large-area geotechnical site by this method can be time-consuming, expensive, and damaging to many surface points of the site. Wave-propagation method, on the other hand, measures seismic velocities at different depths and stiffness profile (stiffness change with depth) can be obtained from the measured velocity data. The stiffness profile is often expressed by shear-wave (S-wave) velocity change with depth because S-wave velocity is proportional to the shear modulus. that is a direct indicator of stiffiiess. The crosshole and downhole method measures the seismic velocity by placing sources and receivers (geophones) at different depths in a borehole. Requirement of borehole installation makes this method also time-consuming, expensive, and damaging to the sites. Spectral-Analysis-of-Surface-Waves (SASW) method places both source and receivers at the surface, and records horizontally-propagating surface waves. Based upon the theory of surfacewave dispersion, the seismic velocities at different depths are calculated by analyzing the recorded surface-wave data. This method can be nondestructive to the sites. However, because only two receivers are used, the method requires multiple measurements with different field setups and, therefore, the method often becomes time-consuming and labor-intensive. Furthermore. the inclusion of noise wavefields cannot be handled properly, and this may cause the results by this method inaccurate. When multi-channel recording method is employed during the measurement of surface-waves, there are several benefits. First, usually single measurement is enough because multiple number (twelve or more) of receivers are used. Second, noise inclusion can be detected by coherency checking on the multi-channel data and handled properly so that it does not decrease the accuracy of the result. Third, various kinds of multi-channel processing techniques can be applied to f1lter unwanted noise wavefields and also to analyze the surface-wavefields more accurately and efficiently. In this way, the accuracy of the result by the method can be significantly improved. Fourth, the entire system of source, receivers, and recording-processing device can be tied into one unit, and the unit can be pulled by a small vehicle, making the survey speed very fast. In all these senses, multi-channel recording of surface waves is best suited for a routine method for geotechnical characterization in most of civil engineering works.

  • PDF

A study on the availability of underground air for heating/cooling energy in volcano-stratigraphic (화산지질층 지하공기 열원 이용 가능성에 관한 연구)

  • Kim, Yong-Hwan;Kim, Sung-Man;Lee, Dong-Won;Hyun, Myun-Taek
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.136-141
    • /
    • 2013
  • This study introduces and analyzes the energy for heating and cooling system in region with volcano-stratigraphic. The thermodynamic properties of air through the air blower installed at the entrance of borehole are measured. It estimates the availability of underground air for heating and cooling system through experimental data and theoretical analysis. Based on our conclusion from these calculations we predict possibility of over 40kW steady and stable energy source from underground. Therefore this underground air can be utilized in region with volcano-stratigraphic.

Characterization of Conductive Fractures in Fractured Rocks using Borehole Logging Data

  • 조민조;이대하;이승구;김형찬
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.109-113
    • /
    • 1998
  • 본 연구에서는 전기전도도, 온도, 유속 검층을 이용하여 시추공내의 유동성 단열구조를 확인하고 각 유동성 단열구조를 통한 시추공간의 수리적 연결관계를 해석하였다. 검층은 자연상태와 인근 시추공으로부터의 양수에 의한 부정류상태에서 각각 실시되었다. 자연상태에서는 지하수 유동이 매우 느려 유동성 단열구조가 쉽게 인지되지 않으나, 부정류 상태에서는 각 시추공간의 수리적 연결성을 보여준다. 각 시추공별 검층에서 나타나는 유동성 단열구조는 모두 일치하지 않으며, 특히 부정류 상태에서의 유속 검층에서는 타 검층에서 인지된 유동성 단열구조중 일부만이 시추공간에 서로 수리적으로 연결되어 있음을 보여준다.

  • PDF