• 제목/요약/키워드: Bore

검색결과 523건 처리시간 0.029초

디젤엔진 연료분사관의 자긴가공 (Autofrettage of Fuel Injection Pipe for Diesel Engine)

  • 고승기;송원주;서광선;최현선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.90-95
    • /
    • 2007
  • In order to investigate the optimum condition of the autofrettage process for the diesel engine injection pipe, different values of autofrettage pressure, pressure rising time, pressure holding time, and repetition of autofrettage process were applied. Autofrettage was preformed by applying the hydrostatic internal pressures of 603 MPa, 535 MPa, 500 MPa on the fuel injection pipe, corresponding to theoretically 50%, 30%, and 20% overstrain levels, respectively. The autofrettage residual stresses in the injection pipe were experimentally determined by using X-ray diffractometer. As the overstrain level increased, the magnitude of compressive residual stress at the bore increased. It was found that the rising time to reach the autofrettage pressure, holding time at the autofrettage pressure, and repeating application of the autofrettage pressure on the pipe had no significant influence on the residual stress distributions.

  • PDF

원자외선분광기 초기 On-orbit Calibration 결과

  • 선광일;이대희;박장현;육인수;진호;남욱원;한원용;민경욱;유광선;이진근;신종호;오승한
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권1호
    • /
    • pp.57-57
    • /
    • 2004
  • 과학기술위성 1호(STSAT-1)는 지난 9월 러시아에서 성공적으로 발사되었으며 on-orbit calibration 및 performance check을 위하여 표준 target 및 diffuse source를 관측하였다. 본 발표에서는 G1919B2B, AlF CAM 등의 관측자료를 모델과 비교함으로써 bore-site calibration 및 effective area 등 초기 on-obrit calibraiton 결과를 소개하고자 한다.

  • PDF

SMES용 Model Coil의 특성시험 (Test of the Model Coil for a SMES)

  • 김해종;성기철;조전욱;권영길;류강식;류경우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.726-728
    • /
    • 2001
  • For the development of a small-sized superconducting magnetic energy storage (SMES) system we designed, fabricated and tested the model coil consisting five coils with different features, e.g. winding tensions, bore diameters and materials, cooling channels. The results show that even in the highly pre-stressed small coil A, about 70 % of the coils critical current are degraded. The quench current of the coils A, B and E with narrow cooling channels is two times as high as that of the coil C without them though they are similar except spacers. The test results also indicate that the usual training effect depends on the winding tensions of the coils but the quench characteristic does not change according to materials of a bobbin.

  • PDF

철도 및 도로 횡단공법 시공 사례 (Cases of Excavation Methods for Crossing Railway and Road)

  • 김동준;박영호;이윤범;이은철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.429-435
    • /
    • 2003
  • This paper presents the case studies of Tubular Roof construction Method(T.R.c.M) and Semi Shield method, which were applied to the tunnel excavation under the pre-existing railways. It was proved that T.R.c.M was an effective and safe method for the tunnel excavated in soft soil, giving little damage to the railways located a few meters above. Semi Shield was also performed successfully to bore a tunnel in soft and hard rock, minimizing the ground settlement and tilting of vulnerable fuel tanks. Site and soil conditions are also discussed, which led these relatively new methods to success. Finally, comparison of the measurement results and the design values are made to verify and improve the current design practice.

  • PDF

High Temperature Size Exclusion Chromatography for High Throughput Analysis

  • Chang, Tai-Hyun;Park, Soo-Jin;Cho, Hee-Sook;Kim, Young-Tak;Ihm, Kyu-Hyun
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.202-202
    • /
    • 2006
  • With a modern size exclusion chromatography (SEC) column, molecular weight analysis of a polymer sample takes about 10 min. However, it is desirable to reduce the analysis time further, in particular, for high throughput measurements required in combinatorial analyses or 2D-HPLC analyses. We implemented the high temperature SEC for the purpose. By inserting a narrow bore tubing between the column and the detector, a sufficient backpressure can be maintained to prevent the mobile phase from boiling and the effluent is cooled down enough when it reaches the detector. Therefore, a normal SEC detector can be used without any modification. The SEC resolution is greatly improved at the elevated temperature at high flow rate which allows high speed operation.

  • PDF

인삼(Panax ginseng C. A. Meyer)의 성숙한 배로부터 체세포 배발생을 통한 구분화 및 유식물체의 개화 (Plant Regeneration through Somatic Embryogenesis from Mature Zygotic Embryos of Ginseng(Panax ginseng C. A. Meyer) and Flowering of Plantlets)

  • 이행순
    • Journal of Plant Biology
    • /
    • 제32권3호
    • /
    • pp.145-150
    • /
    • 1989
  • Mature zygotic embryos dissected from ginseng(Panax ginseng C. A. Meyer) seeds were cultured on Murashige and Skoog's (MS) medium containing various concentrations of 2, 4-dichlorophenoxyacetic acid(2, 4-D) and kinetin. Somatic embryos were induced directly from cotyledonary tissue or from intervening callus. The induction frequency of somatic embryos was up to 55%. Upon transfer to half-strength MS medium supplemented with 1 mg/1 6-benzyladenine(BA) and 1 mg/1 GA3, most somatic embryos developed into plantlets. Over 50% of the plantlets flowered after 4 weeks of culture and then a few bore immature fruits in vitro. Therefore, it is suggested that the juvenility of the ginseng tissue which give rise to somatic embryos does not interfere with in vitro flowering of their regenerated plantlets.

  • PDF

$\mu$ SMES 마그네트용 모델 코일의 ?치 특성 (Quench Characteristic of the Model Coil for a $\mu$ SMES Magnet)

  • 김해종;성기철;조전욱;김석환;이언용;권영길;류강식;류경우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.5-9
    • /
    • 2001
  • For the development of a small-sized superconducting magnetic energy storage($\mu$SMES) system we designed, fabricated and tested a model coil consisting of five coils with different features. e.g. winding tensions. bore diameters and materials. cooling channels. The results show that even in the highly pre-stressed small coil the quench currents of the coils are degraded to about 70% of their coils critical current. The quench currents of the coils with natrow cooling channels are two times as high as that of the coil without spacers. The test results also indicate that the usual training effect depends on the winding tensions of the coils according to materials of the bobbin.

  • PDF

$\mu$ SMES 마그네트용 Model Coil의 제작 및 특성시험 (Fabrication and Test of the Model Coil for a $\mu$ SMES Magnet)

  • 김해종;성기철;조전욱;이언용;권영길;류강식;류경우
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.89-91
    • /
    • 2001
  • For the development of a small-sized superconducting magnetic energy storage (SMES) system we designed, fabricated and tested the model coil consisting five coils with different features, e.g. winding tensions, bore diameters and materials, cooling channels. The results show that even in the highly pre-stressed small coil A, about 70 % of the coils critical current are degraded The quench current of the coils A, B and E with narrow cooling channels is two times as high as that of the coil C without them though they are similar except spacers. The test results also indicate that the usual training effect depends on the winding tensions of the coils but the quench characteristic does not change according to materials of a bobbin.

  • PDF

$\mu$-HPLC의 Column-Switching 기술을 이용한 식품중 비타민 $B_{12}$의 분석 (Determination of Vitamin $B_{12}$ in Foods Using Column-Switching Technique in $\mu$-HPLC)

  • 박성진;김혜경;함태식;김병용
    • 한국식품영양과학회지
    • /
    • 제28권6호
    • /
    • pp.1208-1211
    • /
    • 1999
  • Semi HPLC using a column switching technique was used to determine the trace content of vitamin B12 in various foods. Total analytical time required less than 20 mins per sample and the recovery ratio was 99.9, 99.6, 100.1 and 99.8% for 1.0, 10.0, 100.0 and 1,000 g/kg, respectively. The content of vitamin B12 in various foods obtained using column switching method showed higher levels compared to labels in dried milk(0.5 g/100g) and in grain products(0.51~34.36 g/100g). Thus, this column switching method was more sensitive, effective and precise than the microbiological analysis currently used to determine the trace compounds like a vitamin B12.

  • PDF

초전도 자기분리에 의한 원재료에서의 철산화물 제거 (The removal of iron oxides from raw materials by superconducting magnetic separator)

  • 권준모;하동우;김태형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.193-193
    • /
    • 2010
  • Magnetic separation is expected to be applied for material refinement as an important supporting technology. In the superconducting magnetic separation, the cohesive force between particles is strong compared with that in the other magnetic separation. The use of high magnetic field by the superconducting magnet enhances the magnetic substance capture ability of the magnetic separation. Industrial raw materials was used for the superconducting magnetic separation. Cry-cooled, NB-Ti superconducting magnet with. 100 mm room temperature bore and 600 mm of height was used for magnetic separator.

  • PDF