• Title/Summary/Keyword: Borated water

Search Result 17, Processing Time 0.023 seconds

Development of hybrid resin to reduce silica in borated water

  • Ramzan Akhtar ;Shahid Latif ;Syed Aizaz Ali Shah ;Shaukat Saeed ;Abdul Aziz
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2547-2555
    • /
    • 2023
  • Amberlite IRN-78 resin was incorporated with iron to make a hybrid resin for the removal of silica from the borated water of nuclear power plants. The hybrid resin contained 0.84 wt % iron compounds upon pyrolysis. In batch experiments carried out at room temperature, 1 g of the hybrid resin removed ~60 ㎍ silica from 1 ppm borated water in ~120 min. The efficiency of the hybrid material increased with the resin quantity, decreased with silica concentration, and remained unchanged at different pH values. Freundlich and Temkin isothermal adsorption dominated the silica removal process and followed the pseudo-first-order and intra-particle diffusion mechanism simultaneously. The concentration of the leached iron remained appreciably under the safe limits of 200 ㎍/l during the experiments. This detailed study suggests the use of hybrid resin for the removal of silica from borated water streams and other similar systems.

Scoping Analyses for the Safety Injection System Configuration for Korean Next Generation Reactor

  • Bae, Kyoo-Hwan;Song, Jin-Ho;Park, Jong-Kyoon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.395-400
    • /
    • 1996
  • Scoping analyses for the Safety Injection System (SIS) configuration for Korean Next Generation Reactor (KNGR) are peformed in this study. The KNGR SIS consists of four mechanically separated hydraulic trains. Each hydraulic train consisting of a High Pressure Safety Injection (HPSI) pump and a Safety Injection Tank (SIT) is connected to the Direct Vessel Injection (DVI) nozzle located above the elevation of cold leg and thus injects water into the upper portion of reactor vessel annulus. Also, the KNGR is going to adopt the advanced design feature of passive fluidic device which will be installed in the discharge line of SIT to allow more effective use of borated water during the transient of large break LOCA. To determine the feasible configuration and capacity of SIT and HPSI pump with the elimination of the Low Pressure Safety Injection (LPSI) pump for KNGR, licensing design basis evaluations are performed for the limiting large break LOCA. The study shows that the DVI injection with the fluidic device SIT enhances the SIS performance by allowing more effective use of borated water for an extended period of time during the large break LOCA.

  • PDF

A Conceptual Study on a Method of Boron Powder Direct Vessel Injection (붕산 분말의 원자로 용기 직접 주입 방식에 대한 개념 연구)

  • 박천태;이준;김영인;윤주현;지성균
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.4
    • /
    • pp.350-353
    • /
    • 2004
  • The integral reactor is tripped by the boron injection to the reactor when the CEA(Control element assembly) is not available due to its malfunction. In general, the borated water is made by dissolving the boron powder in the water and is stored in a tank. and then injected. But, this method is disadvantageous from the view point of construction cost, operation and maintenance because it has many components and is complicated. In this study, the boron powder direct vessel injection method is adopted to improve the system. Injecting the boron powder directly to the vessel and decreasing of number of components, the system configuration, operation and maintenance is simplified and the construction cost is reduced.

  • PDF

Scattering Effectiveness of Monoenergetic Neutrons in the Various Shielding Materials

  • Yoo, Young-Soo
    • Nuclear Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.39-45
    • /
    • 1972
  • In neutron shielding, the scattering effect is equally important as the attenuations in shielding materials. In the present study, the scattered dose equivalent was measured using a Rem counter for water, paraffin, borated paraffin, ordinary and heavy concrete, lead, iron, and tissue equivalent material in three different angles: 45$^{\circ}$, 90$^{\circ}$, and 135$^{\circ}$, respectively. The measurements were performed for the neutron, having the energies of 0.5, 1, 2, 5, and 18 MeV, which are produced from the Van do Graaff accelerator. The scattered dose equivalent ratios were increased with increasing the thickness of scattering materials and saturated at a certain thickness although they were different from one to other materials under study. The ratios were large for lead and iron while they were small for the hydrogen containing materials such as water and paraffin etc.

  • PDF

Pool boiling heat transfer of a copper microporous coating in borated water

  • Jun, Seongchul;Godinez, Juan C.;You, Seung M.;Kim, Hwan Yeol
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.1939-1944
    • /
    • 2020
  • Pool boiling heat transfer of a copper microporous coating was experimentally studied in borated water with a concentration of boric acid from 0.0 to 5.0 vol percent (vol%) to determine the effect of boric acid on boiling heat transfer in water. A high-temperature, thermally conductive microporous coating (HTCMC) was created by sintering copper powder with an average particle size of 67 ㎛ onto a 1 cm × 1 cm plain copper surface with a coating thickness of ~300 ㎛ within a furnace in a vacuum environment. The tests showed that the nucleate boiling heat transfer coefficient (NBHT) of HTCMC became slightly less enhanced as the concentration of boric acid increased but the NBHT coefficient values were still significantly higher than those of the plain surface. The critical heat flux (CHF) values from 0 to 1.0 vol% were maintained at ~2,000 kW/㎡, and then, they gradually decreased down to ~1,700 kW/㎡ as the concentration increased further to 5.0 vol%. It is believed that the micro-scale pores of the HTCMC were partially blocked by the high boric acid concentration during the nucleate boiling such that the small bubbles were not effectively created using the HTCMC reentrant cavities as the boric acid concentration increased.

The Characteristics of Hydraulic Valve for a Passive Reactor (피동형 원자로의 Hydraulic Valve 특성 실험)

  • Kim, Sang-Nyung;Kim, Yoong-Seock
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.8
    • /
    • pp.1083-1090
    • /
    • 1998
  • A kind of three-way check valve, so called hydraulic calve was proposed for the substitute of the density lock of passive reactor such as SPWR (System-Integrated Pressurized Water Reactor). The function of the valve are the separation of the borated water from main coolant loop for normal operation and the insurge of the water into the loop for shutdown and the removal of the decay power when the main coolant flow rate is not enough. To verify the operability and the characteristics of the valve, experimental works were executed with 1/3 scale model calve. Also a diffuser model was proposed for the theoretical analysis of the valve.

Criticality benchmark of McCARD Monte Carlo code for light-water-reactor fuel in transportation and storage packages

  • Jang, Junkyung;Lee, Hochul;Lee, Hyun Chul
    • Nuclear Engineering and Technology
    • /
    • v.50 no.7
    • /
    • pp.1024-1036
    • /
    • 2018
  • In this paper, McCARD code was verified using various models listed in the NUREG/CR-6361 benchmark guide, which provides specifications for single pin-cells, single assemblies, and the whole core classified depending on the nuclear properties and structural characteristics. McCARD code was verified by comparing its results with those of SCALE code for single pin-cell and single assembly benchmark problems. The difference in the multiplication factor obtained through the two codes did not exceed 90 pcm. The benchmark guide treats a total of 173 whole core experiments. The experiments are categorized as simple lattices, separator plates, reflecting walls, reflecting walls and separator plates, burnable absorber fuel rods, water holes, poison rods, and borated moderator. As a result of numerical simulation using McCARD, the mean value of the multiplication factors is 1.00223 and the standard deviation of the multiplication factors is 285 pcm. The difference between the multiplication factors and the experimental value is in the range of -665 pcm to + 1609 pcm. In addition, statistics of results for experiments categorized by reactor shape, additional structure, burnable poison, etc., are detailed in the main text.

EFFECT OF SOLUBLE ADDITIVES, BORIC ACID (H3BO3) AND SALT (NaCl), IN POOL BOILING HEAT TRANSFER

  • Kwark, Sang-M.;Amaya, Miguel;Moon, Hye-Jin;You, Seung-M.
    • Nuclear Engineering and Technology
    • /
    • v.43 no.3
    • /
    • pp.195-204
    • /
    • 2011
  • The effects on pool boiling heat transfer of aqueous solutions of boric acid ($H_3BO_3$) and sodium chloride (NaCl) as working fluids have been studied. Borated and NaCl water were prepared by dissolving 0.5~5% volume concentration of boric acid and NaCl in distilled-deionized water. The pool boiling tests were conducted using $1{\times}1\;cm^2$ flat heaters at 1 atm. The critical heat flux (CHF) dramatically increased compared to boiling pure water. At the end of boiling tests it was observed that particles of boric acid and NaCl had deposited and formed a coating on the heater surface. The CHF enhancement and surface modification during boiling tests were very similar to those obtained from boiling with nanofluids. Additional experiments were carried out to investigate the reliability of the additives deposition in pure water. The boric acid and NaCl coatings disappeared after repeated boiling tests on the same surface due to the soluble nature of the coatings, thus CHF enhancement no longer existed. These results demonstrate that not only insoluble nanoparticles but also soluble salts can be deposited during boiling process and the deposited layer is solely responsible for significant CHF enhancement.