• Title/Summary/Keyword: Booster

Search Result 353, Processing Time 0.032 seconds

To examine the construction plan of the lightening rod equipment for the J-booster pumping station in and around KEPCO'a high voltage distribution power line (한전 배전선로 주변에 위치한 J가압장의 피뢰설비 구축방안 검토)

  • Hong, Sung-Taek;Lee, Eun-Chun;Shin, Gang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.293-295
    • /
    • 2003
  • KEPCO's high voltage distribution power line laid under the ground near to the J-booster pumping station that supply water for living. Lightening rod equipment does not installed at the J-booster pumping station because KEPCO's over head ground wire for protection functions as a lightening rod equipment. In this study, it is concerned whether KEPCO's over head ground wire for protect the distribution power line affect to the J-booster pumping station which is installed for reduce the damage from the direct and indirect lightening. If KEPCO's protection area does not affect to the J-pumping station, it is plan to examine the construction method of lightening rod protection angle and lightening rod equipment and to suggest the optimum protection plan using the surrounding structure based on the suitability of protection area.

  • PDF

Energy-Saving and Environmental Evaluation of Water Supply System on Replacing Water Storage Installed Booster Pump System by Direct Connecting Booster Pump System (저수조 설치 펌프직송방식의 수도직결 증압방식 전환에 관한 에너지절약성 및 환경성 검토)

  • Lee, Chulgoo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.3
    • /
    • pp.7-12
    • /
    • 2015
  • Currently water supply system with water storage is generally applied except for small building such as single-family houses, and water supply system on replacing water storage installed system by direct connecting system has been increasing because of sanitary and energy-saving aspects. The purpose of this study is to evaluate energy-saving and environmental efficiency of direct connecting booster pump system in comparison with the water storage installed system. The architectural condition of the evaluation subject is ten-story apartment house in which sixty households live. To calculate the power consumption of the pump, the volume of water supply was determined from existing data and other data, such as head, efficiency of the pump, was the value used for general application in design office. The power consumption of the water supply pump for one day was 8.5 kWh for direct connecting booster pump system, and 22.5 kWh for water storage installed system, and the former system showed energy savings of 62% compared to the latter system. Reduced power consumption also leads to reduction of $CO_2$ emission. According to the criteria presented in the Korea Energy Management Corporation, reducing the 2,410 kg $CO_2$ emission is possible per year.

Development and Formative Evaluation of Web-based Contents for Engineering Mathematics Based on a Computer Algebra System (컴퓨터 대수 시스템 기반의 이공계 수학용 웹 콘텐츠 개발과 형성 평가)

  • Jun, Young-Cook;Kim, Jin-Young;Kwon, Sun-Kweol;Heo, Hee-Ok
    • Journal of the Korean School Mathematics Society
    • /
    • v.10 no.1
    • /
    • pp.27-43
    • /
    • 2007
  • The aim of this paper is to develop a web-based learning system in order to motivate college students in the area of science and engineering to study college calculus. We designed and developed web-based contents, named MathBooster, using Mathematica, webMathematica and phpMath taking advantages of rapid computation and symbolic computation. The features of MathBooster consists of four parts: graphical representation of calculus concepts, textual illustrations of conceptual understanding, example-based step-by-step learning with phpMath, and quizzes with diagnostic feedback. After the MathBooster was practiced with engineering students, the formative evaluation was conducted with survey items composed in four categories: user responses, screen layout, practicing examples and diagnostic feedback in solving quizzes. The overall level of user satisfaction was statistically measured using SPSS. Those results indicate which parts of MathBooster are needed for future enhancement.

  • PDF

Performance Analysis of the Nozzleless Booster (무노즐 부스터 성능해석)

  • Kim, Kyungmoo;Khil, Taeock;Ryu, Taeha
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.2
    • /
    • pp.72-82
    • /
    • 2017
  • Nozzleless booster is one of the applicable components for integral rocket ramjet (IRR). In order to predict nozzleless solid booster performance, the simplified theoretical analysis was applied for L/D=5, 6, 7, 9, 11, and 13. Al-HTPB and Zr-HTPB propellant with a high metal content were used to increase the hardness because of the combustion gas flow effect. It was found that the trends between the simplified theoretical analysis and experiments were similar.

A Study of Numerical Analysis for Stage Separation Behavior of Two-body Vehicle (비행체 단분리 거동 예측에 대한 수치 연구)

  • Park, Geunhong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.91-98
    • /
    • 2018
  • A numerical investigation of stage separation behavior of a two-body vehicle focusing on its flow characteristics is carried out. For this simulation, the separation of a booster from a vehicle is modeled using a chimera grid system and calculated with commercial code, $CFD-FASTRAN^{TM}$. Consideration of spring force, gravity and relative acceleration of a booster is the essential factor of a realistic simulation. In this study, it is validated that the booster separation time decreases with an increase in flight Mach number and angle of attack. In view of results thus far achieved, it is expected that the dynamics modeling and boundary condition set-up applied in this study will be useful for estimating safe stage separation and event sequencing of flight tests.

Immune response to 19A serotype after immunization of 19F containing pneumococcal conjugate vaccine in Korean children aged 12-23 months

  • Lee, Hyun-Ju;Park, So-Eun;Kim, Kyung-Hyo
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.4
    • /
    • pp.163-168
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the immune response to serotype 19A in children aged 12-23 months after immunization of the 19F containing 7-valent pneumococcal conjugate vaccine (PCV7). Methods: Blood samples from a total of 45 subjects (age 12-23 months) were included in the study. Subjects were categorized according to immunization status into three groups as follows: 18 subjects with 3 primary doses and 1 booster dose of PCV7 (booster group), 21 subjects with 3 primary doses before 12 months of age (primary group), and 6 subjects with no vaccination history of PCV7 (control group). An ELISA and opsonophagocytic killing assay (OPKA) was done to evaluate the immune responses against serotypes 19F and 19A. Results: According to the ELISA, all subjects had antibody titers ${\geq}0.35{\mu}g/mL$ for serotypes 19F and 19A in the booster and primary group and 83.0% and 66.7% in the control group, respectively. According to the OPKA, subjects with opsonic activity (${\geq}20$) against serotypes 19F and 19A were 100% and 61.1% of the subjects in the booster group and 66.7% and 19.0% in the primary group, respectively. No subjects in the control group had opsonic antibodies against both serotypes. Conclusion: In conclusion, in children 12-23 months age who were previously vaccinated with PCV7, a cross-reactive immune response is elicited against serotype 19A after a primary series of 3 doses in a small proportion of subjects, and this response is amplified after booster vaccination.

An Immunoserological Study of Vaccine Against Haemorrhagic Fever with Renal Syndrome (신증후출혈열 백신의 면역혈청학적 연구)

  • Woo, Young-Dae;Chu, Yong-Kyu;Baek, Luck-Ju;Lee, Ho-Wang
    • The Journal of Korean Society of Virology
    • /
    • v.30 no.1
    • /
    • pp.11-18
    • /
    • 2000
  • Since $Hantavax^{TM}$, formalin inactivated Hantaan virus vaccine (10,240 ELISA units/ml), has been developed in 1990 to prevent against haemorrhagic fever with renal syndrome (HFRS) caused by Hantaan or Seoul virus, it has been commercially available in Korea. Twenty-one healthy people were booster shot once and twice after primary basic vaccination with $Hantavax^{TM}$. Seroconversion rates were measured by immunofluorescent antibody technique (IFAT), enzyme-linked immunosorbent assay (ELISA), high density composite particle agglutination (HDPA), and plaque reduction neutralization test (PRNT). Seroconversion rates of 21 vaccinees at one year after primary basic vaccination were 52.3%, 95.2%, 0.0%, 47.6%, and 28.6%, and 13 vaccinees at one month after 1st booster vaccination were 100%, 100%, 30.7%, 100% and 100% by IFAT, ELISA (IgG, IgM), HDPA and PRNT, respectively. Seroconversion rates declined slightly by twenty months, and they were 84.6%, 92.3%, 0.0%, 84.6% and 69.2% by IFAT, ELISA (IgG, IgM), HDPA and PRNT, respectively. Seroconversion rates of 9 vaccinees at three months after 2nd booster vaccination were 100%, 100%, 0.0%, 100%, and 88.9%, and 16 vaccinees at one year after the 2nd booster vaccination were 87.5%, 93.8%, 0.0%, 87.5% and 81.3% by IFAT, ELISA (IgG, IgM), HDPA and PRNT, respectively. Based on the above result $Hantavax^{TM}$ has proved a vigorous anamnestic response after the 1st and the 2nd booster vaccination and has persisted higher fluorescence, agglutination and neutralizing antibody titers in vaccinees.

  • PDF

Prediction of the Occurring Time of Stall for a Booster Fan in a Power Plant Combusting Low Quality Coal through Draft Loss (저품위탄 연소시 탈황용 승압송풍기 실속시점 예측)

  • Kim, Yeong-Gyun;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.8 no.4
    • /
    • pp.34-39
    • /
    • 2012
  • This study presents how low quality coal combustion affects the desulfurizer draft system by correlating of draft loss in a coal-fired thermal power plant and predicts the stall occurrence time of a booster fan. In case of low quality coal, a lot of coal is needed to generate equivalent output power, thereby the rating of increasing draft loss was faster than designed amount of coal. We surely confirmed that draft loss affects the specific energy of a booster fan strongly. On this basis, it is possible to predict the occurring time of stall for a booster fan from current operation specific energy to stall limit specific energy. This study suggests increasing speed of draft loss in each caloric value and the impact of specific energy at a booster fan, it expects to help safe operating in a thermal power plant.

  • PDF

An Indirect Data Transfer Technique based on MIL-STD-1553B for the Software Upgrade of Embedded Equipments on a Missile Assembly with Booster (완성 유도탄 탑재장비의 소프트웨어 업그레이드를 위한 MIL-STD-1553B 기반 간접적 데이터 전송 기술)

  • Kim, Kipyo;Yu, Haesung;Lee, Heoncheol;Yun, Seokjae;Ahn, Keehyun;Woo, Deogyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.43-49
    • /
    • 2016
  • This paper addresses the problem of the software update or upgrade of embedded equipments on a missile assembly with booster. Because the embedded equipments are assembled delicately and closely one another with various communication and power cables, they should be very carefully disassembled to directly upgrade the software of a certain embedded equipment. This may cause not only the costs for disassembly and reassembly but also additional tests to verify the completeness of the reassembled missile as a missile assembly with booster. This paper presents an indirect data transfer technique based on MIL-STD-1553B through Guidance Control Unit to easily upgrade the software of other equipments without any additional costs caused by disassembly and reassembly. The presented technique was successfully applied to the software upgrade of various equipments on real missile assembly with booster.

Controller Development of Booster Multi-Pump System (급수 가압 멀티 펌프 시스템의 컨트롤러 개발)

  • Lee, Sang-Kyun;Lee, Jae-Choon;Lee, Byeong-Hoon;Hwang, Min-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.382-384
    • /
    • 1996
  • This paper introduces the controller development of booster multi-pump system with constantly estimated control algorithm. Through analyzing by the experiment of optimal pressure with a certain flow rate. The larger pressure processing apparatus in microprocessor makes optimal water-supplying. This method is implemented with the only pure control algorithm without any other mechanical or circuitry apparatus. Also, Pump's life is lengthened by exchanging simple on, off and rotational inverter control. Optimal condition for pump is adjusted by the inverter control, and compact control panel helps the booster system install in real field.

  • PDF