• Title/Summary/Keyword: Bone-conducted signal

Search Result 7, Processing Time 0.025 seconds

Study and Effects of Bone Conducted Signal on the Implantable Microphone (골전도를 통한 생체신호가 이식형 마이크로폰에 미치는 영향 및 고찰)

  • Woo, S.T.;Jung, E.S.;Kim, M.N.;Cho, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.29-34
    • /
    • 2010
  • The fully implantable hearing devices (FIHDs) have been studied to compensate the defect of conventional hearing aids. Typically, a microphone for FIHDs was implanted under the skin of the temporal bone. So, implantable microphone characteristics can be affected by the eating food, chattering teeth and moving artifact. In this paper, we fabricated the physical model that was similar to characteristics of human temporal bone and skin, and we measured implanted microphone sensitivity for effect of bone conducted noise signal. For the measurement of microphone sensitivity, we applied 1 kHz pure sounds that were transmitted to implanted microphone and sine wave vibrations of varied frequency were simultaneously transmitted through the artificial bone. As a result, sensitivity of implanted microphone can be modified by bone conducted signal and this phenomenon was confirmed at varied frequency band.

Effects of plant-derived natural products on inflammatory bone destructive disease

  • Ko, Seon-Yle
    • International Journal of Oral Biology
    • /
    • v.44 no.4
    • /
    • pp.130-143
    • /
    • 2019
  • Rheumatoid arthritis, osteoarthritis, and periodontal disease are bone destructive diseases mainly caused by inflammation. Various studies are being conducted to develop treatments for inflammatory bone destructive diseases. Many of these studies involve plant-derived natural compounds. In these studies, cell differentiation, signal transduction pathways, and bone resorption were measured at the cellular level. In disease-induced animal models, the amount of inflammatory mediators or matrix destructive enzymes and serum metabolic markers were measured. This study examined the effects of plant-derived natural compounds, such as flavonoids, on inflammatory bone destructive diseases. In addition, we structurally classified various substances used to maintain bone health and summarized the biological effects and related mechanisms of the components.

Color Doppler Ultrasonographic Evaluation in Observing the Affects of $Osteoset^{(R)}$ on Radial Defects in Beagle Dogs (개에서 $Osteoset^{(R)}$의 요골 결손부 충진에 대한 색도플러초음파검사의 유용성 평가)

  • Jeon, Jong-Hoon;Seong, Yun-Sang;Eom, Ki-Dong;Kim, Jae-Hoon;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This study is conducted to compare ultrasonographs with plain radiographs in monitoring bone regeneration during reconstruction of critical sized radial defects in dogs. A 15 mm bony defect was taken on each of the eight dog's radius using an electrical saw and an external fixator was applied. The experimental groups were divided into non-treated group(group 1) and $Osteoset^{(R)}$-treated group(group 2). Each fracture site was evaluated using plain radiography and ultrasonography. Radiographic callus formation occurred after $11.50{\pm}1.12$ days in group 1 and $11.50{\pm}0.5$ days in group 2. Neovascularized flow signal could be seen $6.50{\pm}1.5$ days and the vascular signal disappeared after $45.00{\pm}6.16$ days after operation in group 1. Neovascularized flow signal was observed $6.75{\pm}1.78$ days and vascular signal disappeared $23.25{\pm}3.03$ days after surgery which was caused by acoustic shadowing in group 2. Early stages of regeneration were observed more clearly with color Doppler ultrasonography than with plain radiography. Also from the results it is concluded that color Doppler ultrasonography are useful in observing initial stages of bone repair.

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

A Study on the Usefulness of Copper Filters Made with 3D Printers in Longbone Examination Using Long Length Detector (장골 검출기를 이용한 장골 검사에서 3D 프린터로 제작한 구리 필터의 유용성 연구)

  • Kim, Woo-Young;Seo, Hyun-Soo;Han, Bong-Ju;Yoon, Myeong-Seong;Lee, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.607-613
    • /
    • 2021
  • Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are transmitted a lot in thin areas such as an ankle, and it is not suitable for diagnosing an image. Therefore, this study use copper filters made with 3D printers to increase image quality in the Long-bone inspection. A copper filter was manufactured in consideration of the overall thickness of the lower part. The experiment was conducted in anterior-posterior (AP) and lateral (LAT) positions, depending on the presence or absence of the filter. 5x5 pixels of region of interest (ROI) were selected from the pelvis, knee, and ankle areas. X-rays were irradiated under the conditions of 70 kVp and 40 mAs for AP, 80 kVp, and 63 mAs for lat when without filters, 90 kVp and 80 mAs for AP, 90 kVp and 100 mAs for lat when with filters. signal to noise ratio(SNR) ratio and contrast to noise (CNR) values were measured 1106.38, 14.34 before applying the filter and 1189.32, 70.43 after the filter. For the knee area, 650.44, 97.61 before applying the filter, and 1013.17, 444.24 after applying the filter. For the ankle area, 206.65, 23.68 before applying the filter and 993.50, 136.11 after applying the filter. In the Long-bone examination, SNR and CNR were greatly measured when the filter was applied, confirmed the availability of using the copper additional filter.

The Manufacture of Digital X-ray Devices and Implementation of Image Processing Algorithm (디지털 X-ray 장치 제작 및 영상 처리 알고리즘 구현)

  • Kim, So-young;Park, Seung-woo;Lee, Dong-hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.195-201
    • /
    • 2020
  • This study studied scoliosis, one of the most common modern diseases caused by lifestyle patterns of office workers sitting in front of computers all day and modern people who use smart phones frequently. Scoliosis is a typical complication that takes more than 80% of the nation's total population at least once. X-ray are used to test for these complications. X-ray, a non-destructive testing method that allows scoliosis to be easily performed and filmed in various areas such as the chest, abdomen and bone without contrast agents or other instruments. We uses NI DAQ to miniaturize digital X-ray imaging devices and image intensifier in self-shielding housing with Vision Assistant for drawing lines to the top and the bottom of the spine to acquire angles, i.e. curvature in real-time. In this way, the research was conducted to see scoliosis patients and their condition easily and to help rapid treatment for solving the problem of posture correction in modern people.

A Measurement System for Color Environment-based Human Body Reaction (색채 환경 기반의 인체 반응 정보 측정 시스템)

  • Kim, Ji-Eon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.2
    • /
    • pp.59-65
    • /
    • 2016
  • The result of analyzing the cognitive reaction due to the color environment has been applied to various filed especially in medical field. Moreover, the study about the identification of patient's condition and examination the brain activity by collecting the bio-signal based on the color environment is being actively conducted. Even though, there were a variety of experiments by convention the color environment using a light or LED color, it still has a problem that affects the psychological information. Therefore, our proposed system using a HMD (Head Mounting display) to provide a completed color environment condition. This system uses the BMS(Biomedical System) to collect the biometric information which responds to the specific color condition and the human body response information can be measured by the development the Memory and Attention test on Mobile phone. The collection of Biometric information includes electro cardiogram(ECG), respiration, oxygen saturation (Sp02), Bio-impedance, blood pressure will store in the database. In addition, we can verify the result of the human body reaction in the color environment by Memory and Attention application. By utilizing the reaction of the human body information that is collected thought the proposed system, we can analyze the correlation between the physiological information and the color environment. And we also expect that this system can apply to the medical diagnosis and treatment. For future work, we will expand the system for prediction and treatment of Alzheimer disease by analyzing the visualization data through the proposed system. We will also do evaluation on the effectiveness of the system for using in the rehabilitation program.