• Title/Summary/Keyword: Bone wire

Search Result 131, Processing Time 0.023 seconds

THE EFFECTS OF TOOTH MOBILITY AND DESIGN OF DIRECT RETAINER ON THE STRESS OF SUPPORTING TISSUES IN UNILATERAL DISTAL EXTENSION REMOVABLE PARTIAL DENTURE (편측후방연장 국소의치에서 지대치 동요도와 직접유지장치의 설계가 지지조직의 응력에 미치는 영향)

  • Jong, Young-Wan;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.59-72
    • /
    • 2000
  • This study was performed to investigate the effects of tooth mobility and design of the direct retainer on the stress of supporting tissues in distal extension removable partial denture. Tooth mobility was simulated and four different types of direct retainer such as Alters clasp, I-bar clasp, wrought wire clasp, and Dalbo attachment were designed and stress on the support-ing tissues were measured and analyzed with straingauge method. The following conclusions were drawn from this study. 1. The stress revealed at the lingual side of alveolar bone of the abutment tooth in edentulous area was the largest. 2. The stress at the lingual side of alveolar bone of the abutment tooth in edentulous area was increased according to the increase of tooth mobility in I-bar clasp and Dalbo attachment. 3. The stress at the residual ridge crest was the great in Dalbo attachment on mobility 0, in I-bar clasp on mobility 1, and in wrought wire clasp on mobility 2. 4. There was little changes of stress according to the increase of tooth mobility at buccal and lingual side of the residual ridge crest and around the abutment teeth in dentulous area.

  • PDF

The Treatment of Gunshot Wound with Maxillofacial Fracture in a Dog

  • Kim, Young-ung;Lee, Dong-bin;Heo, Su-young;Kim, Nam-soo
    • Journal of Veterinary Clinics
    • /
    • v.35 no.5
    • /
    • pp.215-217
    • /
    • 2018
  • A one-year-old, intact male, 24 kg, mixed breed dog was referred to the Animal Medical Center, Iksan, Chonbuk, Korea for treatment of a gunshot wound to the head. Physical examinations revealed bilateral nasal bleeding and open-mouth breathing. Radiographic examination showed fracture of the right maxilla bone and multiple fractures of the nasal bone. A $1cm{\times}1cm{\times}1.8cm$ region of mineral opacity material was observed in the right-cranial ventralnasal cavity and a $6mm{\times}6mm{\times}9mm$ region of mineral opacity material was present in the left-cranial dorsal-nasal cavity. The surgical procedure involved removal of bone fragments and the lodged bullet as well as the installation of three intraosseous wires. At two weeks after surgery, the patient exhibited no complications and had a good prognosis.

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

  • Jo, Young-Hoon;Lee, Seung Gun;Kook, Incheol;Lee, Bong Gun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.152-155
    • /
    • 2020
  • Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft.

A COMPARISON OF DEMINERALIZED FREEZE-DRIED BONE AND HYDROXYAPATITE IN THE TREATMENT OF PERIODONTAL OSSEOUS DEFECTS IN DOGS (이종 탈회 건조골 및 Hydroxyapatite 제재의 골 이식이 성견 치조골 결손부 치유에 미치는 영향에 관한 비교연구)

  • Jung, Sung-Hwa;Kim, Jong-Yeo;Lee, Jae-Hyun
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.185-195
    • /
    • 1994
  • This study was conducted to evaluate the healing potential of hydroxyapatite and demineralized freeze dried bone in 5 dogs. Chronic periodontitis was induced by ligating elastic wire randomized as follows. The group in which only flap operation was performed was used as control. The group in which flap operation using nonresorbable nonporous hydroxyapatite (Orthomatrix)was performed was used as experimental I. The group which flap operation using resorbable porous hydroxyapatite (Biocoral) was performed as experimental II. The group in which flap operation using demineralized freeze-dried bone was performed was used as experimental III. Thereafter dogs serially sacrificed at the 1,2,4 and 8 weeks and the specimens were prepared, and stained with Hematoxilin-Eosin stain for the light microscopic evaluation. The results of the this study were as follows : 1. Control group : progressive inflammatory cell infiltration till 4 weeks and epithelial undergrowth. 2. Group I. : epithelial undergrowth and new bone formed with fibrous margin around HA granule. 3. Group II. : no epithelial undergrowth and direct bone formation at the porous granule 4. Group III. : could not see epithelial undergrowth but obviously new cementum formation.

  • PDF

Subacute Osteomyelitis on Phalangeal Bone Resulting from Multiple Kirschner Pin Fixation: Case Report (원위지 골절에 K-강선을 이용한 비관혈적 정복술 후 생긴 아급성 골수염 1례)

  • Kim, Jae Woo;Choi, Hwan Jun;Kim, Mi Sun;Kim, Jun Hyuk
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.409-412
    • /
    • 2007
  • Purpose: Percutaneous Kirschner wire fixation is common method for hand fracture. It is simple but has risk of ascending infection through the pin and bony injury by multiple drilling. Ascending infection through pin tract is mostly superficial and can be treated with antibiotics and aseptic dressing. This is a case review of subacute osteomyelitis on phalangeal bones after Kirschner wire fixation with literature review. Methods: A 40-years-old man with distal phalangeal fracture on right second finger is presented. He went to a local clinic and had percutaneous Kirschner wire fixation under local anesthesia. He was transferred to our hospital for ulcerative wound on DIP joint at 4 weeks after operation. Radiography showed osteolytic change around medulla of middle and distal phalanges, leading to diagnosis of a subacute osteomyelitis. We treated it with amputation at the level of shaft of middle phalanx. Results: The postoperative course was uneventful. We thought several possible reasons for osteomyelitis in our case. First, it could resulted from ascending infection through the wire. Second, it could be resulted from a bony burn by repeated drilling. And bony necrosis could be a consequence of arterial insufficiency caused by 2 pin insertion. Conclusion: We suggest that a precise pinning based on accurate anatomical understanding is required for a percutaneous Kirschner wire fixation. The frequency of drilling should be minimized. Careful observation and patient education for pin site care are essential.

Pull-in Suture Technique for the Disinsertion of the Phalangeal Tendon Distal Insertion (Pull-in 봉합술을 이용한 수지건 원위 부착부 파열의 치료)

  • Kim, Jae Won;Chung, Sung Mo
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.723-728
    • /
    • 2008
  • Purpose: The disinsertion of the phalangeal tendon distal insertion has difficulties in ordinary tenorrhaphy operation for the anatomical features, and still has controversy between non-surgical and surgical management. The purpose of this study is to select treatment for the injury of the phalangeal tendon distal insertion, as we've had a good results from operation treatment with Pull-in suture technique. Methods: We reviewed the hospital records of 12 patients treated with Pull-in suture technique with disinsertion of the phalangeal extensor or flexor tendon distal insertion from June 2006 to June 2007. Eight patients were involved with the tendon disinsertion without bone fracture, and 4 patients were involved with the fracture of the phalangeal tendon distal insertion site. After removal of the K-wire in week 6, active physical exercises were commenced immediately. The mean follow-up period was 12.4 months. Results: All the patients who had tendon disinsertion with bone fracture had IIB, by Wehbe and Schneider's classification 2, and we evaluated the results comparing the same finger of the other hand according to Crawford's evaluation criteria 5. The nine excellent and three good results were obtained and there were no limitation of motor for the patient who had operation for the rupture of flexor tendon as well. There were no particular complications during the follow-up period. Conclusion: The most important thing for the disinsertion of the phalangeal tendon distal insertion is to maintain an accurate and durable reduction state keeping the tension of tendon. At this point, after removal of the K-wire, the Pull-in suture technique allows accurate realignment of the tendon-bone unit without any specific instrumentation under the more stable state. The Pull-in suture technique seems to be a strong alternative for the treatment of disinsertion of the phalangeal tendon distal insertion, with successful treatment outcome(rapid functional recovery and high patient satisfaction).

Versatility of n-butyl-2-Cyanoacrylate for the Reconstruction of Frontal Sinus Comminuted Fracture in Children (소아의 전두동에 발생한 복잡골절에서 Cyanoacrylate의 유용성)

  • Lee, Yong-Seok;Kang, Sang-Gue;Chun, Nam-Joo;Kim, Cheol-Hann;Tark, Min-Seong
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.96-101
    • /
    • 2011
  • Purpose: In treatment of facial bone fracture, occurred in children, we generally use wires, miniplate, absorbable plate or their combination. These foreign bodies can be palpable, and sometimes may cause infections, and need reoperation for removing. When bone fragments are multiple, small or thin, they are hard to handle and make accurate reduction of all fragments. In these cases, a biodegradable tissue adhesive, Histoacryl$^{(R)}$ (n-butyl-2-cyanoacrylate), can be used as fixation technique for small, multiple, and thin fracture fragments. Methods: 3 years old and 6 years old children, who has comminuted fracture on frontal sinus, we used Histoacryl$^{(R)}$ for fixation of multiple bone fragments. After approaching by coronal incision, we pulled out all bone fragments and reconstructed bone fragments by Histoacryl$^{(R)}$ and fixed those on frontal sinus by absorbable plates. Results: Photographs and 3-dimensional CT obtained preoperatively and postoperatively. And we compared them each other in terms of accuracy of reconstructed bony contour. We could reconstruct almost all bone fragments easily along 3-dimensional structure and get excellent aesthetic results. There was no complication such as infection. Conclusion: In treatment of comminuted facial bone fracture, occurred in children, Histoacryl$^{(R)}$ is an excellent method for accurate reconstruction in small and thin bone fragments which cannot be fixed by wire, miniplate or absorbable plate without complication.

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.

Effectiveness of Dual-Maneuver Using K-Wire and Dingman Elevator for the Reduction of Unstable Zygomatic Arch Fracture

  • Yoon, Hyungwoo;Kim, Jiye;Chung, Seum;Chung, Yoon-Kyu
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2014
  • Background: The zygoma is the most prominent portion of the face. Almost all simple zygomatic arch fractures are treated in a closed fashion with a Dingman elevator. However, the open approach should be considered for unstable zygomatic arch fractures. The coronal approach for a zygomatic arch fracture has complications. In this study, we introduce our method to reduce a special type of unstable zygomatic fracture. Methods: We retrospectively reviewed zygomatic arch view and facial bone computed tomography scans of 424 patients who visited the Wonju Severance Christian Hospital from 2007 to 2010 with zygomaticomaxillary fractures, among whom 15 patients met the inclusion criteria. Results: We used a Dingman elevator and K-wire simultaneously to manage this type of zygomatic arch fracture. Simple medial rotation force usually collapses the posterior fractured segment, and the fracture becomes unstable. Thus, the posterior fracture segment must be concurrently elevated with a Dingman elevator through Keen's approach with rotation force applied through the K-wire. All fractures were reduced without any instability using this method. Conclusion: We were able to reduce unstable and difficult zygomatic arch fractures without an open incision or any external fixation device.

The Efficacy of Transverse Fixation and Early Exercise in the Treatment of Fourth Metacarpal Bone Fractures

  • Moon, Suk-Ho;Kim, Hak-Soo;Jung, Sung-No;Kwon, Ho
    • Archives of Plastic Surgery
    • /
    • v.43 no.2
    • /
    • pp.189-196
    • /
    • 2016
  • Background Several techniques have been designed to treat fifth metacarpal fractures reported to be effective. However, these methods cannot be easily applied to the fourth metacarpal due to its central anatomical position. In this study, we sought to analyze the functional outcomes of patients who underwent transverse pinning for a fourth metacarpal bone fracture. Methods A total of 21 patients were selected and their charts were retrospectively reviewed. After fracture reduction, two transverse Kirchner wires were first inserted from the fifth metacarpal to the third metacarpal transversely at the distal part of the fractured bone, and then another two wires were inserted at the proximal part of the fractured bone. The splint was removed approximately one week postoperatively and the Kirchner wires were removed four to five weeks postoperatively. Patients started active and passive exercise one week after the operation. Pain visual analog scores, total active and passive motion, and the active and passive range of motion of the metacarpophalangeal joint and grip strength were evaluated. Results Dorsal angulation improved from a preoperative value of $44.2^{\circ}$ to a postoperative value of $5.9^{\circ}$. Six weeks after surgery, functional recovery parameters, such as range of motion and grip strength, had improved to 98% of the function of the normal side. No major complication was observed. Conclusions We suggest that the transverse pinning of fourth metacarpal bone fractures is an effective treatment option that is less invasive than other procedures, easy to perform, requires no secondary surgery, minimizes joint and soft tissue injury, and allows early mobilization.