• 제목/요약/키워드: Bone scanning

검색결과 287건 처리시간 0.029초

방사선조사가 골무기질함량에 미치는 영양에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE CHANGE OF BONE MINERAL METABOLISM AFTER IRRADIATION)

  • 진해윤;이상래
    • 치과방사선
    • /
    • 제18권1호
    • /
    • pp.53-66
    • /
    • 1988
  • Irradiation is widely used for the treatment of malignant diseases, and possibly cause the osteoporosis. The bone densitometry and bone scintigraphy are valuable when used to monitor the patients longitudinally to access the progression of osteoporosis and risk of osteoradionecrosis. To evaluate the osteoporosis after irradiation of cobalt-60 gamma ray on the lumbar spines of New Zealand white rabbits, bone densitometry by dual photon absortiometry and bone scintigraphy were performed weekly. The decrease of bone density began at the first week after irradiation, and were in the nadir at 4-6th week. The osteoblastic activity measured by bone scintigraphy decreased in the first week, and was in the nadir at 4-6th week. The severity of these changes were related to the radiation dose. In conclusion, the osteoporosis before presentation of the osteoradionecrosis can be developed at low dose irradiation and confirmed by bone densitometry, bone scanning, and histopathology.

  • PDF

성견에서 골유착성 타이타늄 임프란트의 기능적 노출 시기가 주위의 골형성에 미치는 영향 (INFLUENCE OF A FUNCTIONAL LOADING TIME ON BONE FORMATION AROUND OSSEOINTEGRATED TITANIUM IMPLANTS IN ADULT DOGS)

  • 양자호;이호용
    • 대한치과보철학회지
    • /
    • 제29권3호
    • /
    • pp.55-74
    • /
    • 1991
  • The purpose of this study was to investigate the influence of early functional load around osseointegrated titanium implants. 24 titanium plasma spray coated implants (ITI HS-type) were placed into the previously extracted site in the mandible of six adult dogs. The implants were divided into three groups : the control group was the implants without abutment during the experimental period; the experimental group I was loaded by connecting the contoured abutment after 6 weeks of healing; the experimental group II was loaded after 12 weeks of healing: and the mandibular second premolar and surrounding tissues were selected for natural tooth group to compare the implanted group. All dogs were injected intravenously tetracycline, alizarin red S, and calcein for bone labeling. After the experimental period of 18 weeks, the dogs were sacrificed and longitudinal sections of the bone-implant interface were cut and observed using light microscope, scanning electron microscope, and fluorescence microscope. The results of the study were as follows: 1. Light and scanning electron microscopically, all implant surfaces were well contact with bone tissue at the cortical layer, but some areas of cancellous bone were not contact directly. 2. Fluorescence microscopically, number and size of the new secondary osteons around the implant were increased than those of the natural tooth. 3. Fluorescence microscopically, linear and concentrical fluorescence was observed at or near the surface of all implants, and the bone formation and remodeling of the implants loaded after 6 week of healing were great, and unloaded implants were worst. 4. Fluorescence microscopically, endosteal bone formation was greater than periosteal bone formation at or near the implants. 5. Fluorescence microscopically, number and size of linear and concentric fluorescence was increased at the lingual side than the buccal side of the loaded implants. The result of the study indicate the possibility of the early load to the implant via a prosthesis.

  • PDF

Electrospinning으로 제조된 PMMA/PVA Multilayer bone plate의 생체적합성에 관한 연구

  • 곽경아;;이병택;송호연
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 추계학술발표대회
    • /
    • pp.43.1-43.1
    • /
    • 2009
  • Bone plate는 골절된 뼈의 골 유합을 지지하기 위해서 정형외과, 신경외과, 성형외과 및 치과 등에서 널리 사용되고 있다. 하지만 기존의 bone plate는 대부분 금속으로 제작되어 있어 장기간 이식에 따른 부식 및 천연골 강도저하 등으로 인해 1~2년 후 재수술을 해야 하는 문제점을 갖고 있다. 본 연구에서는이런 금속 bone plate의 단점을 개선하고자 생체적합성이 우수한 생분해성 고분자 bone plate를 제작하였다. 사용된 고분자는 생체적합성과 생분해성이우수한 PVA(polyvinly alcohol)와 강도를 유지하기 위한 PMMA(poly methyl methacrylate)를 사용였다. Electrospinning 법으로 PVA와 PMMA fibrous mat를 제작하여 각 mat를 적층시킨 후 열압착을 하여 강도를 증가시킨 PMMA/PVA Mutlilayer bone plate을 제작하였다. 제작된 PMMA/PVA Mutlilayer bone plate의 생체적합성 평가를 위해 MTT assay, 생분해 특성을 관찰하기 위해 Micro-CT와 SBF(simulated body fluid) 내에서의 용해도를 관찰하였다. 또한조골세포의 부착과 분화에 미치는 영향을 SEM(scanning electron microscope)을통해 관찰하였고, 조골세포의 유전자 발현에 미치는 영향을 RT-PCR을통해 확인하였다.

  • PDF

열 플라즈마를 이용한 뼈 폐기물 소각 기술 (Incineration Technology of Bone Waste Using Thermal Plasma)

  • 김우형;김봉수;한상원;기호범;채재우
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.15-19
    • /
    • 2006
  • The meat consumption produces a lot of bone waste everyday. Dumping bone waste without treatment results into environmental hazards. Conventional treatment by pyrolysis is slow, inefficient and produces hazardous by-products. In the work, an investigation of bone waste incinerated using thermal plasma technology is presented. A high temperature arc plasma torch operated at 33 kW was employed for the experiments. Bone waste was incinerated to remove the infectious organic matter and to vitrify the inorganic matter using plasma torch. Bone waste was reduced its 2/3 weight after the treatment. The process was highly efficient, economical, convenient, and fuel free. This method could be used as an alternative method for disposal of bone waste, small infectious animals, hazardous hospital waste, etc.

  • PDF

치과임플랜트 매식후 조기기능이 임플랜트 주위골조직에 미치는 영향에 관한 연구 (A STUDY ON THE EFFECTS OF EARLY LOADING ON THE SURROUNDING BONE TISSUE OF THE DENTAL IMPLANTS)

  • 박희운;양재호;이선형
    • 대한치과보철학회지
    • /
    • 제31권1호
    • /
    • pp.101-127
    • /
    • 1993
  • The purpose of this study was to observe the effects of early loading on the surrounding bone tissue of the implants. 12 ITI HS implants (8 mm) were inserted on the mandible at 3 mongrel dogs. The implants were divided into two groups; the functional group was functioned with crown, and nonfunctional group was functioned without crown. After 3 and 5 months animals were sacrificed and specimens were examined using radiography, light microscopy, scanning electron microscopy. The following results were obtained. 1. On light microscopic and scanning electron microscopic examination, the difference in the amounts of bone attachment between 3 months loaded and unloaded implants were a little. Sometimes more bone attachment were observed in loaded implants. 2. Many osteoids surrounded the fibrous connective tissues indicating of bone remodeling were observed along the outer surface of the implants. 3. On clinical, radiographic, microscopic examination, epithelial downgrowths were not observed and bone attachments to the outer surface of the implants were observed in 3 months loaded and unloaded implants with good oral hygiene. 4. Epithelial downgrowths and crater-like bone resorptions were observed on 5 months loaded and unloaded implants with poor oral hygiene. 5. Many inflammatory cells in the epithelial tissue were packed in the hollow on 5 months loaded implants.

  • PDF

수종의 치근형 골내매식체와 조직간의 반응에 관한 조직학적 연구 (HISTOLOGIC STUDY OF VARIOUS DENTAL IMPLANT-TISSUE INTERFACE)

  • 이호영;김영수
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.7-23
    • /
    • 1990
  • The success or failure of endosseous dental implants is related to the cellular activity at the implant surface. Success seems to be associated with the enclosure of the implant in a non-inflammed connective tissue or the formation of a direct bone implant interface. The purpose of this study was to examine the tissue reactions to the various implants at the submergible state in dog mandible. The $Br\"{a}nemark$, Core-Vent, Intergral, Bone spiral were selected for evaluation and also the Kimplant, Nephrite were used for the experimental study. After 4 months the animals were sacrificed. The interface zone between bone and implant was investigated using x-rays, light microscope, scanning electron microscope, transmission electron microscope. The following results were obtained from this study. 1. $Br\"{a}nemark$, Core-Vent, Kimplant, Integral showed no mobility and bone growth over the healing screws of the implants. Histologically most of the implant surface were covered by remodelled lamellar bone, and partly by a cellular layer or the thin fibrous tissue layer. 2. The Bone spiral showed no mobility and partially radiolucent line around the implant. The upper part of the implant was surrounded by a thin fibrous connective tissue and the middle, apical part of it were contacted with bone directly. 3. The Nephrite implant showed severe mobility and a radiolucent line around the implant. Histologically it showed mild inflammation and was surrounded by a fibrous connective tissue. 4. Scanning electron microscope showed that there was no amorphous ground substance in the Nephrite implant but the formation of ground substance over the collagen filaments in other implants. 5. Transmission electron microscope showed that collagen filaments were approached irregularly to the surface of all implants and in the $Br\"{a}nemark$, Core-Vent, Kimplant, Integral there was amorphous layer between the implant and the collagen filaments. It seemed to be ground substances.

  • PDF

In vivo comparison between the effects of chemically modified hydrophilic and anodically oxidized titanium surfaces on initial bone healing

  • Lee, Hyo-Jung;Yang, Il-Hyung;Kim, Seong-Kyun;Yeo, In-Sung;Kwon, Taek-Ka
    • Journal of Periodontal and Implant Science
    • /
    • 제45권3호
    • /
    • pp.94-100
    • /
    • 2015
  • Purpose: The aim of this study was to investigate the combined effects of physical and chemical surface factors on in vivo bone responses by comparing chemically modified hydrophilic sandblasted, large-grit, acid-etched (modSLA) and anodically oxidized hydrophobic implant surfaces. Methods: Five modSLA implants and five anodized implants were inserted into the tibiae of five New Zealand white rabbits (one implant for each tibia). The characteristics of each surface were determined using field emission scanning electron microscopy, energy dispersive spectroscopy, and confocal laser scanning microscopy before the installation. The experimental animals were sacrificed after 1 week of healing and histologic slides were prepared from the implant-tibial bone blocks removed from the animals. Histomorphometric analyses were performed on the light microscopic images, and bone-to-implant contact (BIC) and bone area (BA) ratios were measured. Nonparametric comparison tests were applied to find any significant differences (P<0.05) between the modSLA and anodized surfaces. Results: The roughness of the anodized surface was $1.22{\pm}0.17{\mu}m$ in Sa, which was within the optimal range of $1.0-2.0{\mu}m$ for a bone response. The modSLA surface was significantly rougher at $2.53{\pm}0.07{\mu}m$ in Sa. However, the modSLA implant had significantly higher BIC than the anodized implant (P=0.02). Furthermore, BA ratios did not significantly differ between the two implants, although the anodized implant had a higher mean value of BA (P>0.05). Conclusions: Within the limitations of this study, the hydrophilicity of the modSLA surface may have a stronger effect on in vivo bone healing than optimal surface roughness and surface chemistry of the anodized surface.

치과용 Ti-6Al-4V 합금 골 고정판 표면에 형성된 나노튜브의 부식거동 (Corrosion Behavior of Nanotube Formed on the Bone Plate of Ti-6Al-4V Alloy for Dental Use)

  • 김원기;이충환;정재헌;최한철
    • 한국표면공학회지
    • /
    • 제43권1호
    • /
    • pp.25-30
    • /
    • 2010
  • Titanium and titanium alloys are widely used for orthopedic and dental implants for their superior mechanical properties, low modulus, excellent corrosion resistance and good biocompatibility. In this study, corrosion behaviors of nanotube formed on the bone plate of Ti-6Al-4V alloy for dental use have been investigated. $TiO_2$ nanotubes were formed on the dental bone plates by anodization in $H_3PO_4$ containing 0.6 wt % NaF solution at $25^{\circ}C$. Electrochemical experiments were performed using a conventional three-electrode configuration with a platinum counter electrode and a saturated calomel reference electrode. Anodization was carried out using a scanning potentiostat (EG&G Co, Model 263A USA), and all experiments were conducted at room temperature. The surface morphology was observed using field emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The corrosion behavior of the dental bone plates was examined using potentiodynamic test(potential range of -1500~2000 mV) in a 0.9% NaCl solution by potentiostat (EG&G Co, PARSTAT 2273. USA). The inner diameter of nanotube was about 150~180 nm with wall thickness of about 20 nm. The interspace of nanotube to nanotube was 50 nm. The passive region of the nanotube formed bone plates showed the broad range compared to non-nanotube formed bone plates. The corrosion surface of sample was covered with corrosion products.

탈단백 우골의 골이식 대체재로서의 특성에 대한 평가;세 종류의 골 대체재의 기본 특성에 대한 비교분석 (Evaluation of deproteinized bovine bone mineral as a bone graft substitute;A comparative analysis of basic characteristics of three commercially available bone substitutes)

  • 박진우
    • Journal of Periodontal and Implant Science
    • /
    • 제35권4호
    • /
    • pp.863-875
    • /
    • 2005
  • Bovine bone-derived bone substitutes are widely used for treatment of bone defects in dental and orthopedic regenerative surgery. The purpose of this study was to evaluate the basic characteristics of deproteinized bovine bone mineral as a bone graft substitute. Commercially available products from three different bovine bone minerals-Bio-Oss(GeistlichPharma, Switzerland), BBP(Oscotec. Korea), Osteograf/N-300(Dentsply Friadent Ceramed, USA) - were investigated. They were evaluated by scanning electron microscopy(SEM), energy dispersive X-ray spectrometer(EDS), surface area analysis(BET), and Kjeldahl protein analysis. Cell viability on different products was evaluated by 3-(4, 5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide(MTT) assay. The results of this study indicated that each bone substitute displayed distinct surface properties. Furthermore, Kjeldahl protein analysis indicated that residual crude proteins are present in deproteinized bovine bone mineral. BBP showed relatively large amount of residual protein, which indicated that the possibility of disease transmission can not be safely ruled out. Based on the results of this study, it is suggested that active quality management is strongly needed in operations that involve processing bovine bone tissue for medical use.

Effect of Total Collimation Width on Relative Electron Density, Effective Atomic Number, and Stopping Power Ratio Acquired by Dual-Layer Dual-Energy Computed Tomography

  • Jung, Seongmoon;Kim, Bitbyeol;Yoon, Euntaek;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.165-171
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effect of collimator width on effective atomic number (EAN), relative electron density (RED), and stopping power ratio (SPR) measured by dual-layer dual-energy computed tomography (DL-DECT). Methods: CIRS electron density calibration phantoms with two different arrangements of material plugs were scanned by DL-DECT with two different collimator widths. The first phantom included two dense bone plugs, while the second excluded dense bone plugs. The collimator widths selected were 64 mm×0.625 mm for wider collimators and 16 mm×0.625 mm for narrow collimators. The scanning parameters were 120 kVp, 0.33 second gantry rotation, 3 mm slice thickness, B reconstruction filter, and spectral level 4. An image analysis portal system provided by a computed tomography (CT) manufacturer was used to derive the EAN and RED of the phantoms from the combination of low energy and high energy CT images. The EAN and RED were compared between the images scanned using the two different collimation widths. Results: The CT images with the wider collimation width generated more severe artifacts, particularly with high-density material (i.e., dense bone). RED and EAN for tissues (excluding lung and bones) with the wider collimation width showed significant relative differences compared to the theoretical value (4.5% for RED and 20.6% for EAN), while those with the narrow collimation width were closer to the theoretical value of each material (2.2% for EAN and 2.3% for RED). Scanning with narrow collimation width increased the accuracy of SPR estimation even with high-density bone plugs in the phantom. Conclusions: The effect of CT collimation width on EAN, RED, and SPR measured by DL-DECT was evaluated. In order to improve the accuracy of the measured EAN, RED, and SPR by DL-DECT, CT scanning should be performed using narrow collimation widths.