• Title/Summary/Keyword: Bone quality type

Search Result 105, Processing Time 0.029 seconds

Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading

  • Kim, Seong-Beom;Yun, Pil-Young;Kim, Sang-Yun;Yi, Yang-Jin;Kim, Ji-Yun;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.396-403
    • /
    • 2016
  • PURPOSE. Early loading of implant can be determined by excellent primary stability and characteristic of implant surface. The implant system with recently improved surface can have load application 4-6 weeks after installing in maxilla and mandible. This study evaluated the effect of healing period to the stability of hydrophilic tapered-type implant at maxillary posterior area. MATERIALS AND METHODS. This study included 30 patients treated by hydrophilic tapered-type implants (total 41 implants at maxilla) and classified by two groups depending on healing period. Group 1 (11 patients, 15 implants) was a control group and the healing period was 12 weeks, and Group 2 (19 patients, 26 implants) was test group and the healing period was 6 weeks. Immediately after implant placement, at the first impression taking, implant stability was measured using Osstell Mentor. The patients also took periapical radiographs after restoration delivery, 12 months after restoration and final followup period. The marginal bone loss around the implants was measured using the periapical radiographs. RESULTS. All implants were survived and success rate was 97.56%. The marginal bone loss was less than 1mm after 1 year postoperatively except the one implant. The stabilities of the implants were not correlated with age, healing period until loading, insertion torque (IT), the diameter of fixture and the location of implant. Only the quality of bone in group 2 (6 week) was correlated with the stability of implant. CONCLUSION. Healing period of 6 weeks can make the similar clinical prognosis of implants to that of healing period of 12 weeks if bone quality is carefully considered in case of early loading.

AN EXPERIMENTAL STUDY OF PLATELET-DERIVED GROWTH FACTOR ABOUT BONE FORMATION IN DENTAL IMPLANT (혈소판 유래 성장인자가 임플란트 주위 골형성에 미치는 효과에 대한 실험적 연구)

  • Ryu, Jae-Jun;Kwon, Jong-Jin;Kim, Han-Kyum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.816-831
    • /
    • 1998
  • Bony fixation of implants during the early phase of healing is important in order to get secondary stability of the implant assuring the success of the treatment. Because the successful placement of the implant is limited by the quality and quantity of bone, other agents which stimulate bone formation in the peri-implant spaces has been illustrated. Platelet-derived growth factor (PDGF) has been shown to regulate DNA and protein synthesis in bone cells in vitro and to interact synergistically to enhance soft tissue wound healing in vivo. The purpose of this study was to evaluate bone promotion around implants which were augmented with sagittal split osteotomy or autogenous veneer bone graft using the platelet derived growth factor(PDGF). After placement of newly designed twenty four screw-type implants, which were 12mm in length and 4mm in diameter in 6 dogs. $4{\mu}g$ of PDGF B/B was applied with surgicel carriers. The dogs were sacrificed at 3 days, 1, 2, 3, 6, and 12 weeks after implantation. Specimens were examined clinically, radiographically, histologically, and histomorphometrically. The results were as follows: 1. Clinically and radiologically, there was no significant difference in bone formation and healing pattern between experimental and control group. 2. In autogenous veneer bone graft group, bone formation was observed at 1st week in the experimental groups but 2nd week in the control groups. At 3rd week, the expeimental groups showed more bone formation comparing to the control groups. 3. In sagittal split osteotomy group, bone formation was observed at 1st week in both groups. But the experimental groups showed more bone formation comparing to the control groups after 2nd week. 4. The bone growth rate of experimental group was more rapid than that of control group. These results indicated that PDGF did not affect the initiation of new bone formation, but it accelerated the bone formation at the early period.

  • PDF

Retrospective analysis of $frialit-2^{(R)}$ implant system placed in maxilla (상악에 식립된 Frialit-2 임플란트의 성공률에 대한 후향적 연구)

  • Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Shim, June-Sung;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.449-460
    • /
    • 2005
  • Objectives Aim of this study was to evaluate the clinical use and the efficacy of Frialit-2 implant system. Experimental Methods Fifty nine patients received placement of Frilalit-2 implants(137 implants) in their maxillary anterior and posterior sites(40 and 97 implants). Intraoral & clinical examination, chart review and radiographs were taken from each patient. Results 1. The total implant survival rate was 92.7% after a mean follow-up period of 19.9 months. 2. The implant survival rate placed in anterior region was 97.5%. 3. The implant survival rate placed in posterior region was 90.7%. 4. The implant survival rate placed in atrophic posterior maxilla with advanced technique (GBR, Sinus elevation) was 87.2%. 5. The implant survival rate placed in type N(D4) bone was 82%, while 95.7% in type III (D3), and 100% in type II(D2) bone. 6. Most of the failed implants(7 of 10) were removed during the maintenance stage after prosthodontic treatment. Conclusion It was concluded that Frialit-2 implant could be used satisfactorily in the esthetic anterior region, but the use in the posterior region, especially with poor bone quality and quantity, further studies are needed.

Embodiment of outside orbit type supersonic waves multi curer for Fracture patient's type (radish stimulation, radish invasion) rehalititation promotion (Fracture 환자의 유형(무자극,무침습) 재활촉진을 위한 외부궤도형 초음파 다층치료기의 구현)

  • Kim, Whi-Young;Choe, Jin-Yeong;Park, Seong-Jun;Kim, Jin-Yeong;Park, Seong-Jun;Kim, Hui-Je
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2165-2166
    • /
    • 2006
  • Estrangement hierarchical by bipolarization is deepened and time space that social welfare by graying corresponds great so. Specially, is real condition that indifference by patient's increase which is solitary life string is come to involve by social problem.Together, Jaetaek bone fracture patient's ratio is zooming. Domestic BT technology, medical treatment solution technology offer more important role than role assistance enemy of modern technology and utilize by creative technology can. Specially, if apply supersonic waves in bone fracture treatment, there is treatise data that can reduce bone fracture treatment period of bone that bone does not stick well about 40%. Supersonic waves operation frequency used on both end because do 1m Hz, 1.3mHz, supersonic waves origination that have 1.5mHz's Piezo-ceramic crystal tranducer material each 4 premature senilitys in this research, and outside diameter according to impedance and Phase d used Gakgak4mm, 5.4mm, Dukke0.5mm, transformer deuce of length 70mm. Manufactured, and investigated supersonic waves distribution chart by capacity 50m W. Supersonic waves used by diagnosis mainly but is seen to become convenient medical treatment mounting in bone fracture patient's treatment if supplement clinically.If supplement system furthermore, is going to apply to osteoporosis patient, and this research tried to design poetic theme width directly and study rain standardization special quality and approach basic form because do modelling.

  • PDF

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level (임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구)

  • Shin, Dong-Hwan;Cho, Kyoo-Sung;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

MINISCREW STABILITY REGARDING DESIGN OF MINISCREW AND THICKNESS OF CORTICAL BONE (교정용 미니스크류의 디자인과 피질골의 두께에 따른 역학적 안정성 평가)

  • Kweon, Young-Sun;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.250-259
    • /
    • 2011
  • The aim of this study was to suggest a design for an orthodontic miniscrew which may work most favorably in the thin cortical bone of the adolescent. In this study, orthodontic miniscrews with different diameters, lengths, and body types were manufactured and implanted in two artificial bone samples with different cortical bone thickness. Maximum insertion torque, maximum removal torque, and lateral alteration torque were measured. As a result, the bone quality, body type, diameter, and the length all had their effects on the maximum insertion torque, maximum removal torque, and lateral alteration torque. Cortical bone thickness was the most important factor. In initial stability, conical types showed better results than cylindrical types. Increase in the diameter had favorable effects in achieving mechanical stability. Increase in the length did not have as much influence as the other factors did on the initial stability, but there was a statistically significant difference between screws of 6 mm and 8 mm lengths(p<0.05). In conclusion, the conical type screw with a diameter of 1.8 mm is most favorable in the thin cortical bone of the adolescent. In terms of length, the 8 mm screw is expected to perform better than the 6 mm screw.

STRESS DISTRIBUTION PATTERN OF THE DIFFERENT DIAMETER AND LENGTH OF SHORT IMPLANTS ACCORDING TO THE BONE QUALITY : 3-D FINITE ELEMENTS ANALYSIS (상이한 골질과 제원에 따른 짧은 임프란트의 응력 분포: 3차원 유한 요소 분석)

  • Kim, Han-Koo;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.116-126
    • /
    • 2009
  • The use of short implants has been accepted risky from biomechanical point of view. However, short implants appear to be a long term viable solution according to recent clinical reports. The purpose of this study was to investigate the effect of different diameter and length of implant size to the different type of bone on the load distribution pattern. Stress analysis was performed using 3-dimensional finite element analysis(3D-FEA). A three-dimensional linear elastic model was generated. All implants modeled were of the various diameter(${\phi}4.0$, 4.5, 5.0 and 6.0 mm) and varied in length, at 7.0, 8.5 and 10.0 mm. Each implant was modeled with a titanium abutment screw and abutment. The implants were seated in a supporting D2 and D4 bone structure consisting of cortical and cancellous bone. An amount of 100 N occlusal load of vertical and $30^{\circ}$ angle to axis of implant and to buccolingual plane were applied. As a result, the maximum equivalent stress of D2 and D4 bones has been concentrated upper region of cortical bone. As the width of implant is increased, the equivalent stress is decreased in cancellous bone and stress was more homogeneously distributed along the implants in all types of bone. The short implant of diameter 5.0mm, 6.0mm showed effective stress distribution in D2 and D4 bone. The oblique force of 100N generated more concentrated stress on the D2 cortical bone. Within the limitations of this study, the use of short implant may offer a predictable treatment method in the vertically restricted sites.

A comparison of the implant stability among various implant systems: clinical study

  • Kim, Jae-Min;Kim, Sun-Jong;Han, In-Ho;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • PURPOSE. To determine the change in stability of single-stage, three different design of implant systems in humans utilizing resonance frequency analysis for early healing period(24 weeks), without loading. MATERIAL AND METHODS. Twenty-five patients were included into this study. A total of 45 implants, three different design of implant systems(group A,C,R) were placed in the posterior maxilla or mandible. The specific transducer for each implant system was used. ISQ(implant stability quotient) reading were obtained for each implant at the time of surgery, 3, 6, 8, 10, 12, 24 weeks postoperatively. Data were analyzed for different implant type, bone type, healing time, anatomical locations. RESULTS. For each implant system, a two-factor mixed-model ANOVA demonstrated that a significant effect on ISQ values(group A=0.0022, C=0.017, R=0.0018). For each implant system, in a two-factor mixed model ANOVA, and two-sample t-test, the main effect of jaw position(P > .005) on ISQ values were not significant. CONCLUSIONS. All the implant groups A, C and R, the change patterns of ISQ over time differed by bone type. Implant stability increased greatly between week 0 and week six and showed slow increase between week six and six months(plateau effect).