• Title/Summary/Keyword: Bone modeling

Search Result 108, Processing Time 0.028 seconds

Review of Ca Metabolic Studies and a Model for Optimizing Gastrointestinal Ca Absorption and Peak Bone Mass in Adolescents

  • Park, Jong-Tae;Cho, Byoung-Kwan;Lee, Wang-Hee
    • Journal of Biosystems Engineering
    • /
    • v.40 no.1
    • /
    • pp.78-88
    • /
    • 2015
  • Purpose: The objective of this study is to review researches regarding factors that potentially affect adolescent calcium (Ca) metabolism, and to suggest a potential modeling approach for optimizing gastrointestinal Ca absorption and peak bone mass. Background: Optimal gastrointestinal Ca absorption is a key to maximizing peak bone mass in adolescents. Urine Ca excretion in adolescents rises only after bone accretion is saturated, indicating that higher intestinal Ca absorption and bone retention is necessary to ensure maximum bone accretion. Hence, maximizing peak bone mass is possible by controlling the factors influencing gastrointestinal Ca absorption and bone accretion. However, a mechanism that explains the unique adolescent Ca metabolism has not yet been elucidated. Review: Dietary factors that enhance gastrointestinal Ca absorption may increase the available Ca pool usable for bone accretion, and a specific hormone may direct optimal Ca utilization to maximize peak bone mass. IGF-1 is an endocrine hormone whose levels peak during adolescence and increase fractional Ca absorption and bone Ca accretion. Prebiotics, generally obtained from dietary sources, have been reported to exert a beneficial effect on Ca absorption via microbiota activity. We selected and reviewed three candidates that could be used to propose a comprehensive Ca metabolic model for optimal Ca absorption and peak bone mass in adolescents. Modeling: Modeling has been used to investigate Ca metabolism and its regulators. Herein, we reviewed previous Ca modeling studies. Based on this review, we proposed a method for developing a comprehensive model that includes regulatory effectors of IGF-1 and prebiotics.

Numerical simulation of the femur fracture under static loading

  • El Sallah, Zagane Mohammed;Smail, Benbarek;Abderahmane, Sahli;Bouiadjra, B. Bachir;Boualem, Serier
    • Structural Engineering and Mechanics
    • /
    • v.60 no.3
    • /
    • pp.405-412
    • /
    • 2016
  • Bone is a living material with a complex hierarchical structure that gives it remarkable mechanical properties. Bone constantly undergoes mechanical. Its quality and resistance to fracture is constantly changing over time through the process of bone remodeling. Numerical modeling allows the study of the bone mechanical behavior and the prediction of different trauma caused by accidents without expose humans to real tests. The aim of this work is the modeling of the femur fracture under static solicitation to create a numerical model to simulate this element fracture. This modeling will contribute to improve the design of the indoor environment to be better safe for the passengers' transportation means. Results show that vertical loading leads to the femur neck fracture and horizontal loading leads to the fracture of the femur diaphysis. The isotropic consideration of the bone leads to bone fracture by crack propagation but the orthotropic consideration leads to the fragmentation of the bone.

Regeneration and modeling of fixed-bed adsorption of fluoride on bone char

  • Hugo D. Garcia;Rigoberto Tovar;Carlos J. Duran;Virginia Hernandez;Ma. R. Moreno;Ma. A. Perez
    • Advances in environmental research
    • /
    • v.12 no.1
    • /
    • pp.17-40
    • /
    • 2023
  • This article presents studies of the adsorption process in a continuous system of fluoride solutions at a concentration of 30 mg/L using a bone char packed in fixed-bed columns, as well as regeneration studies in the same system using HNO3, HCl and NaOH at 0.01, 0.1 and 1 M. The Thomas Model, Artificial Neural Networks (ANNs), Numerical Integration and Mass Transfer Zone were used for the modeling of asyemmetrical breakthrough curves obtained from the fluoride adsorption on bone char. The maximum adsorption capacity of the breakthrough curves was estimated, and various design parameters of the columns were obtained for the different operating conditions. Results showed that an improvement in the modeling capabilities of the Thomas model can be obtained using ANNs. Moreover, ANNs are useful for determining reasonable and accurate design parameters of packed-bed adsorption columns. This modeling approach can be useful for the process system engineering of dynamic adsorption systems involved in the field of water treatment and purification. It is important to highlight that the obtained results indicate that, when using HCl or HNO3 at a concentration of 0.1 M, a large number of adsorption-desorption cycles are obtained and, therefore, the highest values of adsorption capacity, which leads to a reduction in operation costs.

A Study on the Voxel Mesh Technique for Finite Element Modeling of Human Bone (인체 골(bone)의 유한요소 모델링을 위한 VOXEL MESH 기법에 관한 연구)

  • 변창환;오택열;백승민;채경덕
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1081-1084
    • /
    • 2002
  • In this study, we perform 3-D reconstruction of human proximal femur from DICOM files by using voxel mesh algorithm. After 3-D reconstruction, the model converted to Finite Element model which developed for automatically making not only 3-D geometrical model but also FE model from medical image dataset. During this job, trabecular pattern, one of characteristic of human bone can be added to the model by means of giving it's own elastic property calculated from intensity in CT scanned image to the each voxel. And then another model is made from same image dataset which have two material properties - one corresponds to cortical bone, another to trabecular bone. Finally, validity of voxel mesh technique is verified through comparing results of FE analysis, free vibration and stress analysis.

  • PDF

The effect of mechanical properties of bone in the mandible, a numerical case study

  • Ramos, Antonio;Marques, Hugo;Mesnard, Michel
    • Advances in biomechanics and applications
    • /
    • v.1 no.1
    • /
    • pp.67-76
    • /
    • 2014
  • Bone properties are one of the key components when constructing models that can simulate the mechanical behavior of a mandible. Due to the complexity of the structure, the tooth, ligaments, different bones etc., some simplifications are often considered and bone properties are one of them. The objective of this study is to understand if a simplification of the problem is possible and assess its influence on mandible behavior. A cadaveric toothless mandible was used to build three computational models from CT scan information: a full cortical bone model; a cortical and cancellous bone model, and a model where the Young's modulus was obtained as function of the pixel value in a CT scan. Twelve muscle forces were applied on the mandible. Results showed that although all the models presented the same type of global behavior and proximity in some locations, the influence of cancellous bone can be seen in strain distribution. The different Young's modulus defined by the CT scan gray scale influenced the maximum and minimum strains. For modeling general behavior, a full cortical bone model can be effective. However, when cancellous bone is included, maximum values in thin regions increase the strain distribution. Results revealed that when properties are assigned to the gray scale some peaks could occur which did not represent the real situation.

Biomechanical evaluations of the long-term stability of dental implant using finite element modeling method: a systematic review

  • Hosseini-Faradonbeh, Seyed Aref;Katoozian, Hamid Reza
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.3
    • /
    • pp.182-202
    • /
    • 2022
  • PURPOSE. The aim of this study is to summarize various biomechanical aspects in evaluating the long-term stability of dental implants based on finite element method (FEM). MATERIALS AND METHODS. A comprehensive search was performed among published studies over the last 20 years in three databases; PubMed, Scopus, and Google Scholar. The studies are arranged in a comparative table based on their publication date. Also, the variety of modeling is shown in the form of graphs and tables. Various aspects of the studies conducted were discussed here. RESULTS. By reviewing the titles and abstracts, 9 main categories were extracted and discussed as follows: implant materials, the focus of the study on bone or implant as well as the interface area, type of loading, element shape, parts of the model, boundary conditions, failure criteria, statistical analysis, and experimental tests performed to validate the results. It was found that most of the studied articles contain a model of the jaw bone (cortical and cancellous bone). The material properties were generally derived from the literature. Approximately 43% of the studies attempted to examine the implant and surrounding bone simultaneously. Almost 42% of the studies performed experimental tests to validate the modeling. CONCLUSION. Based on the results of the studies reviewed, there is no "optimal" design guideline, but more reliable design of implant is possible. This review study can be a starting point for more detailed investigations of dental implant longevity.

Measures of micromotion in cementless femoral stems-review of current methodologies

  • Solitro, Giovanni F;Whitlock, Keith;Amirouche, Farid;Santis, Catherine
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.2
    • /
    • pp.85-104
    • /
    • 2016
  • Stability and loosening of implanted femoral stems in Total Hip Replacement have been well established as barriers to the primary concerns of osseointegration and long term implant survival. In-vitro experiments and finite element modeling have for years been used as a primary tool to assess the bone stem interface with variable methodologies leading to a wide range of micromotion, interference fit and stress shielding values in the literature. The current study aims to provide a comprehensive review of currently utilized methodologies for in-vitro mechanical testing as well as finite element modeling of both micromotion and interference of implanted femoral stems. A total of 12 studies detailed in 33 articles were selected for inclusion. Experimental values of micromotion ranged from 12 to $182{\mu}m$ while finite element analysis reported a wider range from 2.74 to $1,277{\mu}m$. Only two studies were found that modeled bone/implant contact with consideration for interference fit. In studies evaluating stem micromotion in THA, the reference surface at the bone/stem interface should be well defined. Additionally, the amount of penetration considered should be disclosed and associated with bone density and roughness.

Simulation of Bone Fracture Healing by the Complex System Rule (복잡계를 응용한 인체 골절치료 모델링과 해석에 관한 연구)

  • 문병영;박정홍
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.12
    • /
    • pp.198-204
    • /
    • 2003
  • The bone fracture healing is simulated by using one of the complex system rules, named cellular automata method. It is assumed that each cell has property of Bone, Cartilage or Fibrous connective tissue. Nine local rules are adopted to change the property of each cell against the mechanical stimulus, which consists of the strain energy density, and the existence of bone in the surroundings. Two dimensional sheep metatarsal model is considered and the bone fracture healing is simulated. The simulation results agree well with those obtained by using fuzzy logic model and experimental data. The cellular automata method found to be one of the simulation methods to express the bone fracture healing. The cellular automata method is expected to be effective in representing biological phenomenon.

Ultrashort Echo Time MRI (UTE-MRI) Quantifications of Cortical Bone Varied Significantly at Body Temperature Compared with Room Temperature

  • Jerban, Saeed;Szeverenyi, Nikolaus;Ma, Yajun;Guo, Tan;Namiranian, Behnam;To, Sarah;Jang, Hyungseok;Chang, Eric Y.;Du, Jiang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.202-209
    • /
    • 2019
  • Purpose: To investigate the temperature-based differences of cortical bone ultrashort echo time MRI (UTE-MRI) biomarkers between body and room temperatures. Investigations of ex vivo UTE-MRI techniques were performed mostly at room temperature however, it is noted that the MRI properties of cortical bone may differ in vivo due to the higher temperature which exists as a condition in the live body. Materials and Methods: Cortical bone specimens from fourteen donors ($63{\pm}21$ years old, 6 females and 8 males) were scanned on a 3T clinical scanner at body and room temperatures to perform T1, $T2^*$, inversion recovery UTE (IR-UTE) $T2^*$ measurements, and two-pool magnetization transfer (MT) modeling. Results: Single-component $T2^*$, $IR-T2^*$, short and long component $T2^*s$ from bi-component analysis, and T1 showed significantly higher values while the noted macromolecular fraction (MMF) from MT modeling showed significantly lower values at body temperature, as compared with room temperature. However, it is noted that the short component fraction (Frac1) showed higher values at body temperature. Conclusion: This study highlights the need for careful consideration of the temperature effects on MRI measurements, before extending a conclusion from ex vivo studies on cortical bone specimens to clinical in vivo studies. It is noted that the increased relaxation times at higher temperature was most likely due to an increased molecular motion. The T1 increase for the studied human bone specimens was noted as being significantly higher than the previously reported values for bovine cortical bone. The prevailing discipline notes that the increased relaxation times of the bound water likely resulted in a lower signal loss during data acquisition, which led to the incidence of a higher Frac1 at body temperature.