• Title/Summary/Keyword: Bone density change

Search Result 186, Processing Time 0.033 seconds

Development of a Smartphone Application for Promoting Bone Health in Korean Young Adult Women: A Pilot Study (성인초기 여성의 골건강 증진을 위한 스마트폰 앱 개발 및 적용: 예비연구)

  • Park, Young-Joo;Lee, Sook-Ja;Shin, Nah-Mee;Shin, Hyunjeong;Yoon, Sungjin;Jeon, Songi;Cho, Inhae
    • Korean Journal of Adult Nursing
    • /
    • v.27 no.4
    • /
    • pp.459-471
    • /
    • 2015
  • Purpose: The purpose of this study was to develop a smartphone application and evaluate it's effectiveness and usability for promoting bone health in Korean young adult women. Methods: A smartphone application was developed covering exercise, nutrition, and health habits related to bone health. A pilot testing was conducted using a one-group pre/posttest design. A total of 22 female college students with low bone mass participated in the 8-week use of a pilot testing. Results: The "Strong bone Fit body (SbFb)" application was developed using Android platform. In the pilot testing, bone mineral density, serum CTX, and 25 (OH)Vit.D were significantly decreased. There is no significant change in serum osteocalcin and calcium. Serum phosphorus concentration, nutrient intakes (fiber, VitB6, and pantotenic acid), and all bone composition profiles were significantly increased. Bone-health knowledge was significantly increased but no change in health belief and self-efficacy. Conclusion: The results of this pilot testing suggest the effectiveness of the SbFb application to enhance and promote self-managing abilities for bone health. It can provide continuous feedback and high-quality bone health information. However, some contents and working methods of the application need to be modified and its effectiveness on bone health requires further investigations.

Biomechanical analysis of pullout strength of the pedicle screws in relation to change bone mineral density (반복 하중 후 골밀도 감소에 따른 척추경 나사못의 고정력(Pullout Strength)감소 형태 분석)

  • Jung, D.Y.;Lee, S.J.;Kim, D.S.;Shin, J.W.;Kim, W.J.;Suk, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.155-156
    • /
    • 1998
  • Screw loosening and subsequent pullout can be attributed to the reduction in bone mineral density in the vertebrae manifested by osteoporosis in which the decrease in fixation strength between the cancellous bone and screw threads are accelerated by repeated loads exerted by patients own weight and activities following the surgery. In this study, the change in pullout strength of the pedicle screws was investigated before and after repeated loads were imparted. For this purpose. Diapason pedicle screws $(6.7\times40mm)$ were inserted onto fresh porcine spine specimens (T1-L5) after bone mineral density was measured using a DEXA. With an MTS, an axial load was applied at a loading rate of 0.33mm/sec until failure to measure the maximum pullout strength. Flexion moment of 7.5N-m was then imparted at 0.5Hz for 2000 cycles. It was found that the maximum pullout strength was exponentially related to BMD regardless of load types ($107.71\;\times\;\exp^{(1.43{\times}BMD)}r^2=0.93$, P<0.0001 without repeated load; ($107.71\;\times\;\exp^{(2.19{\times}BMD)}r^2=0.78$, P<0.0001 with repeated load). The results suggest that the reduction in pullout strength for pedicle screws is far more prominent in osteoporotic spine than in normal spine especially as number of repeated load was increased. More importantly, it was demonstrated that the level of bone mineral density and the activity level of the patient should be evaluated in more detail for successful implementation of pedicle screw systems in spinal surgery.

  • PDF

CT Observation of Alloplastic Materials Used in Blow Out Fracture (안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰)

  • Lee, Won;Kang, Dong-Hee
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

Quality and Morphology on cortico-cancellous bone in Korean mandibular symphysis area (한국인 하악 유합부에서의 피질골-해면골의 밀도 및 형태)

  • Min, Cheon-Ki;Park, Hyun-Do;Kim, Chang-sung;Jung, Han-Sung;Cho, Kyoo-Sung;Kim, Hee-Jin;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.581-595
    • /
    • 2001
  • In performing implant procedures in the anterior portion of the maxilla, many difficulties exist because of anatomical reasons, such as the proximity of the nasal floor, lateral extension of the incisive canal, and labial concavity. On the other hand, in the posterior region of the maxilla, there is often insufficient recipient bone between the maxillary sinus and alveolar ridge due to alveolar ridge resorption and pneumatization of the maxillary sinus. In order to perform implants in such regions, ridge augmentation procedures such as onlay bone graft, guided bone regeneration, and maxillary sinus grafting are performed. In studies of Caucasians, use of autograft from mandibular symphysis has been reported to be highly successful in maxillary sinus grafting. However, in a clinical study of Koreans, autograft of mandibular symphysis has been reported to have significantly low success rate. It has been hypothesized that this is because of insufficient cancellous bone due to thick cortical bone. In order to test this hypothesis, bone quality and morphology of Koreans can be compared with those of Caucasians. In this study, the bone density and morphology of the cortical bone and cancellous bone in the mandibular symphysis of 35 Korean cadavers were evaluated. The following results were obtained: 1. In terms of bone density, type I, type II, and type III consisted of 1.4%(3/213), 72.3%(154/213), and 26.3%(56/213) of the cross-sectioned specimens, respectively. In general, the bone density tended to change from type II to type III, as cross-sectioned specimens were evaluated from the midline to the canine. Type IV wasn't observed in this study. 2. The distance between the root apex and the lower border of the cancellous bone was 18.34mm-20.59mm. Considering that the bone has to be cut 5mm below the root apex during the procedure, autografts with about 15mm of vertical thickness can be obtained. 3. The thickness of cortical bone on the labial side increased from the root apex to the lower border of the mandible. The average values ranged from 1.43mm to 2.36mm. 4. The labio-lingual thickness of cancellous bone ranged from 3.43mm to 6.51mm. The thickness tended to increase from the apex to the lower border of the mandible and decrease around the lower border of cancellous bone. From the above results, the anatomic factors of the mandibular symphysis (bone density, thickness, quantity and length of the cortical bone and cancellous bone) didn't show any difference from Caucasians, and it cannot be viewed as the cause of failure in autografts in the maxillary sinus for implants.

  • PDF

PANORAMIC ANALYSIS ABOUT SPONTANEOUS BONE REGENERATION AFTER ENUCLEATION OF JAW CYST (악골 내 발생한 낭종의 적출술 후 자발적인 골의 재생에 대한 파노라마 방사선 분석)

  • Yim, Jeong-Hoon;Lee, Jae-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.3
    • /
    • pp.229-236
    • /
    • 2009
  • Purpose: Some recent literatures report that it is possible to recover defected areas caused by enucleation of relatively large jaw cysts without using bone grafts. The aim was to find out whether spontaneous recovery of defected area with time occurred and what the contributing factors were. Materials and methods: In total, 194 patients were considered as patients. Out of these 194 patients, 74 patients who had no wound dehiscence and who were available for follow-up studies were selected. They were classified into two groups according to the size of radiolucent area in the preoperative panoramic radiographs: in one group, it was larger than $3{\times}4cm$, while in the other group, it was smaller than $3{\times}4cm$. Follow-up panoramic radiographs were taken immediately after the surgery, then after 3, 6, 9 and 12 months. On those radiographs, changes in size and density of the defected areas were observed using the Gray-level histogram of Adobe photoshop v7.0. Correlation between bone regeneration and factors such as the type and size of the cysts, age, sex, site of the cysts and systemic disease was evaluated using the General repeated measure and Mann-Whitney Test. Results: Analyses of panoramic radiographs showed that the recovery of radiopacity after 12 months was more than 97% on average in defected areas that were smaller than $3{\times}4cm$. in the defected areas that were larger than $3{\times}4cm$, considerable portion showed recovery of radiopacity. No statistically significant change was observed in bone density according to the type of cysts. Young patients under 20 years of age with highly active metabolism presented more significant bone regeneration than patients over 20 years of age. Bone regeneration was more hampered in patients who had medical disease, compared with patients who didn’t have any medical problem. No statistically significant change was seen in bone density according to sex. Changes in bone density according to the site of cysts such as maxilla, mandible, anterior or posterior region were not considered to be significant. Conclusion: Analyses of panoramic radiographs suggest that in approximately 12 months after the enucleation of cysts, clinically acceptable spontaneous bone regeneration can be observed even though normal bone graft procedures have not been applied.

An Assessment on effect of Bioabsorbable membrane, allogenic bone and Platelet Rich Plasma in Class II furcation involvement by digital subtraction radiography (2급 치근이개부 치료 시 흡수성 차폐막, 동종골 이식 및 혈소판 농축 혈장의 골 재생 효과에 대한 디지털 공제술의 정량적 분석)

  • Kim, Sang-Hoon;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.173-186
    • /
    • 2002
  • The purpose of this study was to evaluate effect of platelet rich plasma on the treatment of Grade II furcation involvement, with Demineralized Freeze-Dried Bone(Dembone(R)) and bioabsorable membrane(BioMesh(R)) in humans by digital subtraction radiography. 12 teeth(control group) were treated with Demineralized Freeze-Dried Bone(Dembone(R)) and bioabsorable membrane(BioMesh(R)), and 12 teeth(test group) were treated with Demineralized Freeze-Dried Bone(Dembone(R)), bioabsorable membrane(BioMesh(R)) and Platelet Rich Plasma. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content by as much as 5%(vol) could be perceived in the subtracted images. The change of mineral content was assessed in the method that two radiographs are put into computer program to be overlapped and the previous image is subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program (5% significance level). The results were as follows: 1. In test group, the radiopacity in 3 months after surgery were significantly increased than 1 month after surgery(p<0.05). However. there were no significant difference between 1 month after surgery and 3 months after surgery in control group(p>0.05). 2. In test and control group, the radiopacity in 6 months after surgery were significantly increased than 1 month after surgery(p<0.05) 3. In test and control group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 4. There were no significant difference between test group and control group at 1 month, 3 months after surgery, but radiopacity in test group were significantly increased than control group at 6 months after surgery(p<0.05). In conclusion, Platelet Rich Plasma can enhance bone density.

Difference of Bone Density and Risk Factors Related to Osteopenia of Young Women in Their Twenties (20대 여성의 골밀도와 골감소증의 위험요인 비교)

  • Byeon, Young Soon
    • Korean Journal of Adult Nursing
    • /
    • v.18 no.5
    • /
    • pp.790-797
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate bone density and risk factors related to osteopenia to unmarried young adult women. Methods: The subjects consisted of 125 female college students. SPSS 12.0 program was used for the data analysis with t-test, ${\chi}^2-test$. The BMD of the calcaneus and body mass index (BMI) were measured with peripheral dual energy X-ray absorptionmetry. Other physical characteristics were measured with a scale and questionnaires. Results: The general characteristics of these people showed that the average age was 22.1 years old and that the average BMI was 20.8. The mean of BMD was normal, but 24.8% were osteopenia, 75.2% were normal. In the normal and osteopenia groups, there were significant differences in the status of the BMD according to age, height, weight, BMI, regular exercise, house chores, and the experiences of being on a diet. Conclusion: Women in their twenties had some osteoporosis risk, but they can change their BMD by doing regular exercise and by eating food to peak bone mass. For building peak bone mass, they need take exercise programs and education programs to prevent osteoporosis and follow-up care.

  • PDF

Effects of Silkworm Pupae on Bone Mineral Density in Ovariectomized Rat Model of Osteoporesis

  • Ryu, Kang-Sun;Lee, Heui-Sam;Kim, Kee-Young;Kim, Mi-Ja;Kang, Pil-Don
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.24 no.2
    • /
    • pp.63-68
    • /
    • 2012
  • Osteoporosis is characterized by the reduced density of mineralized bone matrix. The loss of bone has been attributed to an imbalance between bone formation and bone resorption. The silkmoth is one of the famous traditional tonic medicines. Silkworm pupa was evaluated for its antiosteoporotic activity in an ovariectomized rat model of osteoporosis. The rats were ovariectomized at 6weeks of age and divided into 7 groups. All the groups were fed without calcium diet. The OVX rats were treated with water and silkworm powder for 6 weeks. In OVX rats, the body weight, feeding and water intake quantity did not show a significant change, but the silkworm pupa powder immediately before the eclosion of Yeonrokjam was significantly increased the bone mineral density in the femoral bone. The silkworm pupa powder increased the bone with increasing calcium in serum. These results also showed its protective action through promotion of bone formation. The silkworm pupa powder has a definite antiosteoporotic effect; similar to estrogen, it is especially effective for the prevention of bone fracture induced by estrogen deficiency. The silkworm pupa powder is a promising anti-osteoporotic agent that can prevent bone fractures in osteoporotic patients. The silkworm pupa powder does not show serious side effects because natural herbal medicine origin.

Effect of $1{\alpha}$, 25 Dihydroxy-vitamin $D_3$ on Bone Resolution in Complete Freund's Adjuvant-induced Osteoporotic Rats (Complete Freund's Adjuvant 투여로 골다공증이 유발된 흰쥐에서 $1{\alpha}$,25 Dihydroxy-vitamin $D_3$가 골흡수에 미치는 영향)

  • 김주영;강성수;김소섭;최석화;배춘식
    • Journal of Veterinary Clinics
    • /
    • v.19 no.3
    • /
    • pp.342-349
    • /
    • 2002
  • Vitamin D is one of important factors involved in the regulation of bone metabolism. In osteoporosis, the therapeutic effect of vitamin D on the healing process has still been controversial. To conform the effect of $1{\alpha}$, 25 dihydroxy-vitamin $D_3$ on osteoporosis, the change of serum calcium, serum phosphorus, serum alkaline phosphatase, bone mineral density and bone mineral content of osteoporotic tibia were examined comparatively in normal control group(positive control), CFA control(negative control), CFA+$1{\alpha}$, 25 dihydroxy-vitamin $D_3$ 0.01 ug/kg group and CFA+$1{\alpha}$, 25 dihydroxy-vitamin $D_3$ 0.1 ug/kg group after osteoporosis was induced by single injection of complete Freund's adjuvant(CFA) in rats. In change of serum calcium. the significantly increased value was shown on 2nd and 5th week(P< 0.05) after treatment in $1{\alpha}$, 25 dihydroxy-vitamin D$_3$ 0.01 ug/kg group and on 3rd week(P<0.05) after treatment in $1{\alpha}$, 25 dihydroxy-vitamin $D_3$ 0.1 ug/kg group than CFA control. In change of serum phosphorus, the significantly increased value was shown on 2nd week(P<0.05) after treatment in $1{\alpha}$, 25 dihydroxy-vitamin $D_3$ 0.01 ug/kg group and on 3rd and 4th week(P<0.05) after treatment in $1{\alpha}$, ,25 dihydroxy-vitamin $D_3$ 0.1 ug/kg group than CFA control. The value of bone mineral density and bone mineral content of tibia was increased in both $1{\alpha}$,25 dihydroxy-vitamin $D_3$ 0.01 ug/kg group and $1{\alpha}$, 25 dihydroxy-vitamin $D_3$ 0.1 ug/kg group than CFA control, and the increase rate of that was higher in $1{\alpha}$, 25 dihydroxy-vitamin $D_3$ 0.1 ug/kg group than $1{\alpha}$, 25 dihydroxy-vitamin $D_3$ 0.01 ug/kg group. Considering above findings collectively, it was considered that $1{\alpha}$, 25 dihydroxy-vitamin $D_3$ was effective in preventing the complete Freund's adjuvant-induced osteoporotic decrease of bone mass.

Change of Bone Mineral Density after Kirindiet therapy in Middle-Aged Obese Women under Normal Bone Mineral Density (정상골밀도이하 중년비만여성환자의 기린다이어트시 골밀도 변화)

  • Choi, Young-Min;Sim, Woo-Jin;Kim, Kil-Soo;Yoon, Yoo-Sik;Shin, Seung-Uoo
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.5 no.1
    • /
    • pp.47-56
    • /
    • 2005
  • Objectives : This study was performed to investigate the change of bone mineral density(BMD) after 1 month Kirindiet therapy including very low calory diet(VLCD) in middle-aged obese women$(65>age{\geqq}40,\;BMI{\geqq}25)$ under normal $BMD(T-score{\leqq}0)$. Methods : We examined body weight, body fat, protein mass and BMD of 13 middle-aged obese women who visited to Kirin Oriental Hospital from Sep. 7. 2004 to Oct. 12. 2005 before and after 1 month Kirindiet therapy. Body weight, body fat and protein mass was checked by Inbody 4.0 and BMD was checked by quantitated computed tomography. Wilcoxon signed rank test was used for analyzing changes of body weight, body fat, protein mass and BMD before and after treatment. Results : Alter 1 month treatment body weight(-4.89Kg, -6.74%, p=0.001), body fat(-3.47Kg, p=0.001) and protein mass(-0.97Kg, p=0.006) was significantly reduced. BMD was significantly increased in all cases(+4.87mg/cc, +4.16%, p=0.001). Though body weight, body fat and protein mass were significantly reduced, BMD was significantly increased(p<0.01). Conclusions : In this study, we can conclude that after 1 month Kirindiet therapy including VLCD, BMD in middle-aged obese women under normal BMD was significantly increased inspite of reduction of body weight, body fat and protein mass.

  • PDF