• 제목/요약/키워드: Bone change

검색결과 923건 처리시간 0.027초

다양한 골 이식재의 임상 효과에 대한 고찰 (A study of the clinical effects of various bone graft materials)

  • 이승범;연제영;채경준;정의원;김창성;이용근;조규성;채중규;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제37권4호
    • /
    • pp.719-732
    • /
    • 2007
  • Purpose: Various bone graft materials are being used for periodontal tissue regeneration. Th materials are being developed continuously for ideal clinical effects. Therefore, it is necessary to identify the clinical characteristics of each bone graft material through comparing the various bone graft materials statistically and in doing so, proposing a more efficient bone graft material. In this study, the following results were attained through comparing the clinical effects among the bone graft materials, using the statistical method based on the clinical studies published at the department of periodontology of Yonsei hospital. Materials and Method: 6 selected studies of department of Periodontology at Yonsei University Hospital were based on clinical study of bone grafting in intrabony defects. It was compared the clinical parameters among the 6 clinical studies, using the statistical META analysis. Result: When comparing the probing depth reduction, there was a relatively great amount of decease when using the xenograft, Anorganic Bovine Derived Hydroxapatite Bone Matrix/Cell Binding Peptide(ABM/P-15: PepGen $P-15^{(R)}$) and the autogenous bone and absorbable membrane, d, 1-alctide/glycolide copolymer(GC: $Biomesh^{(R)}$). The allogfrafts showed a relatively low decrease in the probing depth and clinical attachment change. It also showed a slight decrease in the bone probing depth. The allografts showed various results according to different bone graft materials. When comparing the ABM/P-15 and bovine bone $powder(BBP^{(R)})$, ABM/P-15 showed a relatively high clinical attachment level and the bovine bone powder showed a relatively high clinical attachment level. The probing depth change and gingival recession change showed a lower value than the mean value between the two bone graft materials. The synthetic bone showed a relatively high decrease in clinical attachment level and periodontal probing depth change. There was a relatively larger amount of gingival recession when using Bioactive Glass(BG) but a relatively low bone regeneration effect was seen. Conclusion: Good restorative results of the periodontal tissue can be attained by applying the various bone graft materials being used today after identifying the accurate clinical effects.

Correlation between Radiographic Findings, Clinical Findings and Joint Sounds of Temporomandibular Joint Osteoarthritis Patients

  • Shin, Jung-Youn;Ahn, Jong-Mo
    • Journal of Oral Medicine and Pain
    • /
    • 제42권2호
    • /
    • pp.35-43
    • /
    • 2017
  • Purpose: This study aims to evaluate the correlation between joint sounds and radiographic bone change patterns along with clinical symptoms of temporomandibular joint osteoarthritis (TMJ OA) patients. Methods: The patients for this study were over 19 years of age, diagnosed tentatively with TMJ OA. The patients were examined with temporomandibular disorders analysis test and all three radiographs, including panoramic radiography, transcranial radiography, and cone beam computed tomography (CBCT). Information of the patients' age, pain status, joint sound and mouth opening range were collected. And bone change pattern was examined by reviewing panoramic radiography, transcranial radiography and CBCT images. Results: The patients with crepitus had a higher average active mouth opening (AMO) range than patients without crepitus, and the group with bilateral crepitus had a higher average AMO range than the group with unilateral crepitus (p<0.001). And the patient with pain during mastication was increased in the group with clicking than the group without clicking, and the group with bilateral clicking showed a statistically significant increase in the patient with pain during mastication than the group with unilateral clicking (p<0.05). The analytical results of the relevance of crepitus showed a high correlation with bone change observed from each of the three radiographs. And the agreement in bone change findings from 3 groups of paired radiographs showed high agreement (p<0.001). Meanwhile, 77.2% of CBCT findings showed bone change of condyle without crepitus (p<0.001). Conclusions: This study presented significant results in the evaluation of the correlation with crepitus and bone change of TMJ OA patients from panoramic radiography or transcranial projection. However, the accurate assessment is required through CBCT for the patient with complains of persistent pain, limitation of mouth opening, and occlusal change even if the crepitus does not exist.

The effects of voltage of x-ray tube on fractal dimension and anisotropy of diagnostic image

  • Baik, Jee-Seon;Lee, Sam-Sun;Park, Kwan-Soo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제37권4호
    • /
    • pp.211-215
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the effect of the kV on fractal dimension of trabecular bone in digital radiographs. Materials and Methods: 16 bone cores were obtained from patients who had taken partial resection of tibia due to accidents. Each bone core along with an aluminum step wedge was radiographed with an occlusal film at 0.08 sec and with the constant film-focus distance (32 cm). All radiographs were acquired at 60, 75, and 90 kV. A rectangular ROI was drawn at medial part, distal part, and the bone defect area of each bone core image according to each kV. The directional fractal dimension was measured using Fourier Transform spectrum, and the anisotropy was obtained using directional fractal dimension. The values were compared by the repeated measures ANOVA. Results : The fractal dimensions increased along with kV increase (p < 0.05). The anisotropy measurements did not show statistically significant difference according to kV change. The fractal dimensions of the bone defect areas of the bone cores have low values contrast to the non-defect areas of the bone cores. The anisotropy measurements of the bone defect areas were lower than those of the non-defect areas of the bone cores, but not statistically significant. Conclusion: Fractal analysis can notice a difference of a change of voltage of x-ray tube and bone defect or not. And anisotropy of a trabecular bone is coherent even with change of the voltage of x-ray tube or defecting off a part of bone.

  • PDF

FEM을 이용한 외부고정구 영향에 의한 골-재형성에 대한 해석 (Analysis of bone-remodeling by the influence of external fixator with FEM)

  • 김영은;이원식
    • 대한기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.436-444
    • /
    • 1991
  • A computational method has been developed to analyze the bone-remodeling induced by external fixator. The method was based on the Finite Element Method (FEM) in combination with numerical formulation of adaptive bone-remodeling theories. As a feed-back control variable, compressive strain and effective stress were used to determine the surface remodeling and internal (density) remodeling respectively. Surface remodeling and internal remodeling were combined at each time step to predict the rel situation. A noticeable shape and density change were detected at the region between two pins and density change was decreased with time increment. At final time step, the shape and density distribution were converged closely to its original intact bone model. Similar change was detected in stress distribution. The altered stress distribution due to the pin and external fixator converged to the intact stress distribution with time.

이중에너지 방사선 흡수계측법을 이용한 성인 남녀의 장골 및 경골의 골밀도에 관한 연구 (A STUDY ON THE BONE MINERAL DENSITY OF ILIAC AND TIBIAL BONE USING DUAL ENERGY X-RAY ABSORPTIOMETRY)

  • 조용석;김경원;이경호;박현진;서상수;오상엽
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제22권3호
    • /
    • pp.265-273
    • /
    • 2000
  • Purpose : The aim of this study was to evaluate the bone mineral density of iliac and tibial bone which are frequently selected as autogenic bone graft donor sites, and to evaluate the efficiency of this method as a guideline for the selection of bone graft donor site. Materials and Methods : In this study 61 male and 70 female volunteers at Chungbuk National University Hospital were involved between Jan. 1998 to Sept. 1999. We measured bone mineral density of the iliac and the tibial bone using dual energy X-ray absorptiometry. We evaluated the data using the SAS system for Windows and bone mineral density of the lumbar was used for control. Results : Age showed the highest correlation in correlation matrix between physical and bone variables. Height and weight showed lower correlation of linear increment. In man, the change of bone density according to age demonstrated linear decrease irrespective of the lumbar, ilium, and tibia. In woman, the change of bone density according to age showed cubic form, which increased in the third and forth decade. So it had a peak bone mass on about 35 year-old, thereafter, the change of bone density slowly decreased until 50 year-old, but it rapidly decreased after 50 year-old and it slowly decreased again after 65 year-old. Both in all subjects and subject with osteoporosis, the change of bone mineral density according to age showed statistically significant decrease in lumbar and tibia, but ilium was irrespective. Conclusion : In patients of aged or with osteoporosis, ilium demonstrated less tendency of decrease in bone mineral density than tibia. So this preliminary study suggested that ilium seemed better donor site for autogenic bone graft than tibia.

  • PDF

치밀골 두께 변화에 따른 임플랜트 1차안정성과 즉시하중부담능 평가 (AN EVALUATION OF THE PRIMARY IMPLANT STABILITY AND THE IMMEDIATE LOAD-BEARING CAPACITY ACCORDING TO THE CHANGE OF CORTICAL BONE THICKNESS)

  • 이양진;박찬진;조리라
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.248-257
    • /
    • 2005
  • Statement of problem. Cortical bone plays an important role in the primary implant stability, which is essential to immediate/early loading. However, immediate load-bearing capacity and primary implant stability according to the change of the cortical bone thickness have not been reported. Purpose. The objectives of this study were (1) to measure the immediate load-bearing capacity of implant and primary implant stability according to the change of cortical bone thickness, and (2) to evaluate the correlation between them. Material and methods.48, screw-shaped implants (3.75 mm$\times$7 mm) were placed into bovine rib bone blocks with different upper cortical bone thickness (0-2.5 mm) and resonance frequency (RF) values were measured subsequently. After fastening of healing abutment. implants were subjected to a compressive load until tolerated micromotion threshold known for the osseointegration and load values at threshold were recorded. Thereafter, RF measurement after loading, CT taking and image analysis were performed serially to evaluate the cortical bone quality and quantity. Immediate load-bearing capacity and RF values were analyzed statistically with ANOVA and post-hoc method at 95% confidence level (P<0.05). Regression analysis and correlation test were also performed. Results. Existence and increase of cortical bone thickness increased the immediate load-bearing capacity and RF value (P<0.05) With the result of regression analysis, all parameter's of cortical bone thickness to immediate load-bearing capacity and resonance frequency showed significant positive values (P<0.0001). A significant high correlation was observed between the cortical bone thickness and immediate load-beating capacity (r=0.706, P<0.0001), between the cortical bone thickness and resonance frequency (r=0.753, P<0.0001) and between the immediate load-bearing capacity and resonance frequency (r=0.755, P<0.0001). Conclusion. In summary, cortical bone thickness change affected the immediate load-baring capacity and the RF value. Although RF analysis (RFA) is based on the measurement of implant/bone interfacial stiffness, when the implant is inserted stably, RFA is also considered to reflect implant/bone interfacial strength of immediately after placement from high correlation with the immediate load-baring capacity. RFA and measuring the cortical bone thickness with X-ray before and during surgery could be an effective diagnosis tool for the success of immediate loading of implant.

골밀도 평가방법과 임플란트 안정성 변화의 관찰 (Observation of the change of the dental implant stability and bone density evaluation methods)

  • 고석민;박성재;김인수;송승일;이인경
    • Journal of Periodontal and Implant Science
    • /
    • 제39권2호
    • /
    • pp.185-192
    • /
    • 2009
  • Purpose: The aim of this study was to examine the correlation of the subjective and the objective evaluation of edentulous ridge bone quality, and to evaluate the change of the dental implant stability in each bone density group for early healing period after implant installation. Methods: Sixty-seven implants(Osstem implant$^{(R)}$, Seoul, Korea) were included in this study. We evaluated the bone density by 2 methods. The one was the subjective method which was determined by practitioner s tactile sense, the other was the objective bone type was based on Hounsfield units. The implant stability in each bone type group was assessed by resonance frequency analyzer(Osstell mentor$^{(R)}$). Data were analyzed for the change of the implant stability, and they were compared to verify the difference of groups at the time of installation, 2, 6, 10, 14 weeks postoperatively. Spearman's correlation was used to demonstrate the correlation between the subjective and the objective evaluation of the bone density, and analysis of variance(ANOVA) was used to analyze the differences of implant stability at each time point. Results: There was no close relation between the subjective and the objective evaluation of the bone density(r=0.57). In the subjective groups, there was statistically significant difference between the type 1 and 3 at 10 weeks and between the type 2 and 3 at 14 weeks. In the objective groups, there was no statistically significant difference between the D 1, 2, 3, 4, and 5 group with regard to RFA from baseline to 14 weeks(P>0.1). Conclusions: The implant stability increased over time during the study, and it was improved with bone density proportionally after 2weeks postoperatively. It is recommended that the decision of bone density is base on Hounsfield unit for implant loading time.

Assessing changes of peri-implant bone using digital subtraction radiography

  • Kwon Ji-Yung;Kim Yung-Soo;Kim Chang-Whe
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.273-281
    • /
    • 2001
  • Digital subtraction radiography may be one of the most precise and noninvasive methods for assessing subtle density changes in peri-implant bone, providing additional diagnostic information on implant tissue integration in overall maintenance. The aims of this study were to evaluate density changes after first, second surgery of dental implant and to measure the amount of marginal bone loss 9 months after second surgery using digital subtraction radiography. Bone change around 30 screw-shaped implants in 16 patients were assessed on radiographs. 17 Branemark implants of 3.75mm in diameter(Nobel Biocare, Goteborg, Sweden), 2 Branemark implants of 5.0mm in diameter, 11 $Replace^{TM}$ implants of 4.3mm in diameter(Nobel Biocare, Goteborg, Sweden) were used. To standardize the projection geometry of serial radiographs of implants, customized bite block was fabricated using XCP film holder(Rinn Corporation, Elgin, IL.) with polyether impression material of Impregum(ESPE, Germany) and direct digital image was obtained. Qualitative and quantitative changes on radiographs were measured with Emago software(The Oral Diagnostic System, Amsterdam, Netherlands). The results were as follows: 1. The peri-implant bone density of 69.2% implants did not change and the peri-implant bone density of 30.8% implants decreased after 3 months following first surgery. 2. The crestal bone density of 53.9% implants decreased first 3 months after second surgery. The crestal bone density of 58.8% implants increased 9 months after second surgery. No density change was observed around the midportion of the implants after second surgery, 3. The amount of marginal bone loss between different kinds of implants showed no statistically significant differences (p>0.05). 4. More than 90% of total marginal bone loss recorded in a 9-month period occurred during the first 3 months.

  • PDF

Retrospective study on change in pharyngeal airway space and hyoid bone position after mandibular setback surgery

  • On, Sung Woon;Han, Min Woo;Hwang, Doo Yeon;Song, Seung Il
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권5호
    • /
    • pp.224-231
    • /
    • 2015
  • Objectives: The purpose of this study was to evaluate changes in the pharyngeal airway space and hyoid bone position after mandibular setback surgery with bilateral sagittal split ramus osteotomy (BSSRO) and to analyze the correlation between the amount of mandibular setback and the amount of change in pharyngeal airway space or hyoid bone position. Materials and Methods: From January 2010 to February 2013, a total of 30 patients who were diagnosed with skeletal class III malocclusion and underwent the same surgery (BSSRO) and fixation method in the Division of Oral and Maxillofacial Surgery, Department of Dentistry at the Ajou University School of Medicine (Suwon, Korea) were included in this study. Lateral cephalograms of the 30 patients were assessed preoperatively (T1), immediately postoperatively (T2), and 6 months postoperatively (T3) to investigate the significance of changes by time and the correlation between the amount of mandibular setback and the amount of change in the airway space and hyoid bone position. Results: Three regions of the nasopharynx, oropharynx, and hypopharynx were measured and only the oropharynx showed a statistically significant decrease (P<0.01). A significant posterior and inferior displacement of the hyoid bone was found 6 months after surgery (P<0.01). Analysis of the correlation between the amount of mandibular setback and the amount of final change in the airway space and hyoid bone position with Pearson's correlation showed no significant correlation. Conclusion: In this study, the oropharynx significantly decreased after mandibular setback surgery, and changes in the surrounding structures were identified through posteroinferior movement of the hyoid bone during long-term follow-up. Therefore, postoperative obstructive sleep apnea should be considered in patients who plan to undergo mandibular setback surgery, and necessary modifications to the treatment plan should also be considered.

악관절증에서의 골형태이상과 과두위변화와의 상호관계에 관한 방사선학적 연구 (RADIOGRAPHIC STUDY ON THE INTERRELATION BETWEEN BONE DEF ORMANS AND CONDYLAR HEAD POSITION IN THE TMJ ARTHROSIS)

  • 유동수
    • 치과방사선
    • /
    • 제11권1호
    • /
    • pp.79-87
    • /
    • 1981
  • The author analysed the interrelation between the morphologic changes of bone Structures and the position of condylar head from the routine radiographs of 134 cases of the temporomandibular joint arthrosis. The frequencies of coincidence between the site of bone defrmity and condylar head positional change were examined. Also, the positional changes of condylar head and the direction of condylar movement in relation to the kind of bone deformities were observed. The results obtained were as follows; 1. In 52.65 per cent of total cases, the site, of positional change of condylar head was coincided with the site of bone deformans. The frequencies of the coincidence between these in the five items among seven items examined were above 53 per cent. From the results, it seems that the positional changes of condylar head were related with the morphological change of bone structure. 2. Eburnation and erosion. revealed frequently positional changes in the opening and closing position of the mouth, although in the early stages of the TMJ arthrosis. 3. In the bone deformans, during opene position of the mough 44.81 per cent of total cases revealed backword movement and 37.74 per cent showed forward movement. In closed position of the mouth, downward movement was revealed in 35.23 per cent of total cases and upward movement 28.41 per ,cent of total cases. 4. In the cases showing eburnation, the frequencies of coincidence between the site of positional change and bone deformans were 58.57 per cent of the total cases. that means it was high in the early stages of the TMJ arthrosis.

  • PDF