• 제목/요약/키워드: Bone beam

검색결과 339건 처리시간 0.026초

Book Remodeling Analysis of Femur Using Hybrid Beam Theory (보 이론을 이용한 대퇴골 재생성의 해석)

  • Kim, Seung-Jong;Jeong, Jae-Yeon;Ha, Seong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제24권2호
    • /
    • pp.329-337
    • /
    • 2000
  • An investigation has been performed to develop an analysis tool based on a nonlinear beam theory, which can be used to predict the long-term behavior of an artificial hip joint. The nonlinear behav ior of the femur arise from the coupled dependence of the bone density and the mechanical properties on each other. The beam theory together with its numerical algorithm is developed to take into account the nonlinear bone remodeling process of the femur that is long enough to be assumed as a beam. A piecewise linear curve for the bone remodeling rate is used in the bone remodeling theory and the surface area density of bone is modeled as the third order polynomial function of bone density. At each section of the beam, a constant curvature is assumed and the longitudinal strains are also assumed to vary linearly across the section. The Newton-Rhapson iteration method is used to solve the nonlinear equations for each cross section of the bone and a backward method is used to march along the time. The density and the remodeling signal ar, calculated along with time for the various time steps, and the developed beam theory has been verified by comparing with the results of finite element analysis of a remodeling bone with an artificial hip joint of titanium prosthesis subjected to uni-axial loads and pure bending moment. It is concluded that the developed beam theory can be used to predict the long-term behavior of the femur and thus to design the artificial hip prosthesis.

Evaluation of imaging reformation with cone beam computed tomography for the assessment of bone density and shape in mandible (Cone beam형 전산화단층영상에서 골의 형태와 밀도의 평가)

  • Hong, Sang-Woo;Kim, Gyu-Tae;Choi, Yon-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제38권1호
    • /
    • pp.49-56
    • /
    • 2008
  • Purpose: Diagnostic estimation of destruction and formation of bone has the typical limit according to capacity of x-ray generator and image detector. So the aim of this study was to find out how much it can reproduce the shape and the density of bone in the case of using recently developed dental type of cone beam computed tomography, and which image is applied by new detector and mathematic calculation. Materials and Methods: Cone beam computed tomography (PSR 9000N, Asahi Roentgen Ind. Co., Ltd., Japan) and soft x-ray radiography were executed on dry mandible that was already decalcified during 5 hours, 10 hours, 15 hours, 20 hours, and 25 hours. Estimating and comparing of those came to the following results. Results: The change of inferior border of mandible and anterior border of ramus in the region of cortical bone was observed between first 5 and 10 hours of decalcification. The reproduction of shape and density in the region of cortical bone and cancellous bone can be hardly observed at cone beam computed tomography compared with soft x-ray radiography. The difference of decrease of bone density according to hours of decalcification increase wasn't reproduced at cone beam computed tomography compared with soft x-ray radiography. Conclusion: CBCT images revealed higher spatial resolution. However, contrast resolution in region of low contrast sensitivity is the inferiority of images' property.

  • PDF

A simplified theory of adaptive bone elastic beam buckling

  • Ramtani, Salah;Bennaceur, Hamza;Outtas, Toufik
    • Advances in biomechanics and applications
    • /
    • 제1권3호
    • /
    • pp.211-225
    • /
    • 2014
  • The usual assumption that the increase of fractures in aging bone is due entirely to lower bone density is taken back with respect to the possibility that aging bone fractures result from a loss of stability, or buckling, in the structure of the bone lattice. Buckling is an instability mode that becomes likely in end-loaded structures when they become too slender and lose lateral support. The relative importance of bone density and architecture in etiology bone fractures are poorly understood and the need for improved mechanistic understanding of bone failure is at the core of important clinical problems such as osteoporosis, as well as basic biological issues such as bone formation and adaptation. These observations motivated the present work in which simplified adaptive-beam buckling model is formulated within the context of the adaptive elasticity (Cowin and Hegedus 1976, Hegedus and Cowin 1976). Our results indicate that bone loss activation process leads systematically to the apparition of new elastic instabilities that can conduct to bone-buckling mechanism of fracture.

Correlation between gray values in cone-beam computed tomography and histomorphometric analysis

  • Najmeh, Anbiaee;Reihaneh, Shafieian;Farid, Shiezadeh ;Mohammadtaghi, Shakeri;Fatemeh, Naqipour
    • Imaging Science in Dentistry
    • /
    • 제52권4호
    • /
    • pp.375-382
    • /
    • 2022
  • Purpose: The aim of this study was to analyze the relationships between bone density measurements obtained using cone-beam computed tomography (CBCT) and morphometric parameters of bone determined by histomorphometric analysis. Materials and Methods: In this in vivo study, 30 samples from the maxillary bones of 7 sheep were acquired using a trephine. The bone samples were returned to their original sites, and the sheep heads were imaged using CBCT. On the CBCT images, gray values were calculated. In the histomorphometric analysis, the total bone volume, the trabecular bone volume (referred to simply as bone volume), and the trabecular thickness were assessed. Results: Statistical testing showed significant correlations between CBCT gray values and total bone volume (r =0.537, P =0.002), bone volume (r =0.672, P<0.001), and trabecular thickness (r =0.692, P<0.001), as determined via the histomorphometric analysis. Conclusion: The results indicate a significant and acceptable association between CBCT gray values and bone volume, suggesting that CBCT may be used in bone densitometry.

Comparison of Bone Mineral Density with Pencil Beam and Fan Beam DXA Machine

  • Park, Jeong-Hoon;Lee, Jae-Mun;Youn, Je-Woong;Suh, Tae-Suk;Lee, Heung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.425-426
    • /
    • 2002
  • The bone densitometer is to investigate the bone mineral content and density for the osteoporosis assessment by using dual energy X-ray photons. For the clinical verification of the ISOL's OSTEO plus, the clinical study was performed with healthy and non-menopausal 30 female volunteers. The fan-beam DXA machine (Lunar, Expert) was chosen as a reference. After correlation analysis of their bone mineral densities, a strong correlation was obtained. From the results, it is claimed that the new forearm bone densitometer is clinically useful in osteoporosis diagnosis.

  • PDF

The accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing (골결손부 치유과정에서 cone beam형 전산화단층영상의 정확도)

  • Kang, Ho-Duk;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.69-77
    • /
    • 2007
  • Purpose: To evaluate the accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing in rat model. Materials and Methods: Sprague-Dawley strain rats weighing about 350 gms were selected. Then critical size bone defects were done at parietal bone with implantation of collagen sponge. The rats were divided into seven groups of 3 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 6 weeks, and 8 weeks. The healing of surgical defect was assessed by multi planar reconstruction (MPR) images and three-dimensional (3-D) images of cone beam computed tomography, compared with soft X-ray radiograph and histopathologic examination. Results: MPR images and 3-D images showed similar reformation of the healing amount at 3 days, 1 week, 2 weeks, and 8 weeks, however, lower reformation at 3 weeks, 4 weeks, and 6 weeks. According to imaging-based methodologies, MPR image revealed similar reformation of the healing amount than 3-D images compare with soft X-ray image. Among the four threshold values for 3-D images, 400-500 HU revealed similar reformation of the healing amount. Histopathologic examination confirmed the newly formed trabeculation correspond with imaging-based methologies. Conclusion: MPR images revealed higher accuracy of the imaging reformation of cone beam computed tomography and cone beam computed tomography is a clinically useful diagnostic tool for the assessment of bone defect healing.

  • PDF

Horizontal alteration of anterior alveolar ridge after immediate implant placement: A retrospective cone beam computed tomography analysis

  • Hyun, Young Keun;Lee, Chung Yun;Keerthana, Subramanian;Ramasamy, Selvaponpriya;Song, So-Yeon;Shim, Ji Suk;Ryu, Jae Jun
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.117-125
    • /
    • 2021
  • PURPSE. The aim of this study was to evaluate the labio-lingual alterations of the alveolar bone where the implant was placed immediately after tooth extraction. MATERIALS AND METHODS. Implants were placed immediately after tooth extraction on anterior alveolar ridges in the maxilla and mandible. The pinguide system was used to help determine the location and path of implants during the surgical process. The horizontal distance from implants to the outer border of alveolar bone was measured at the rim and middle of the implants in the cone beam computed tomography images. The alteration of alveolar bone was evaluated comparing the horizontal distances measured immediately after surgery and 3 months after surgery. RESULTS. The results show that more resorption occurred towards the labial bone than the lingual bone in the maxilla. A similar amount of labial and lingual bone resorption was observed in the mandible. CONCLUSION. Considering the horizontal alteration of alveolar bone, labio-lingual positioning of the implant towards the lingual bone in the maxilla and at the center of the alveolar ridge in the mandible is recommended when it is placed immediately after tooth extraction.

Maxillary alveolar bone evaluation following dentoalveolar expansion with clear aligners in adults: A cone-beam computed tomography study

  • Marcio Antonio de Figueiredo;Fabio Lourenco Romano;Murilo Fernando Neuppmann Feres;Maria Bernadete Sasso Stuani;Jose Tarcisio Lima Ferreira;Ana Carla Raphaelli Nahas;Mirian Aiko Nakane Matsumoto
    • The korean journal of orthodontics
    • /
    • 제53권4호
    • /
    • pp.264-275
    • /
    • 2023
  • Objective: To investigate the effects of maxillary orthodontic expansion on the alveolar bone tissue in adult patients treated with aligners by using cone-beam computed tomography. Methods: Thirty patients (22 females and 8 males; mean age: 36.3 years) were treated with Invisalign® aligners. Cone-beam computed tomography and digital models were obtained before (T0) and after (T1) upper arch expansion. The bone thicknesses in the cervical, middle, and apical areas of the incisors, canines, premolar, and first molars were buccally and palatally measured, totaling 96 areas and 2,880 measurements. The buccolingual inclinations and transverse measurements of the teeth were obtained from digital models to correlate them with the bone changes. The statistical tests used were Student's t-test, analysis of variance, and Pearson's correlation tests (p < 0.05). Results: From the 96 areas evaluated, 84 revealed an increase or stability in the alveolar bone thickness and twelve displayed significant bone loss. Bone changes did not correlate with the tooth inclination and transverse measurements. Conclusions: Within the limitation of the present study, mild levels of upper arch expansion obtained with Invisalign® aligners in adult patients did not result in any clinically significant loss of alveolar bone thickness.

Analysis of the root position of the maxillary incisors in the alveolar bone using cone-beam computed tomography

  • Jung, Yun-Hoa;Cho, Bong-Hae;Hwang, Jae Joon
    • Imaging Science in Dentistry
    • /
    • 제47권3호
    • /
    • pp.181-187
    • /
    • 2017
  • Purpose: The purpose of this study was to measure the buccal bone thickness and angulation of the maxillary incisors and to analyze the correlation between these parameters and the root position in the alveolar bone using cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of 398 maxillary central and lateral incisors from 199 patients were retrospectively reviewed. The root position in the alveolar bone was classified as buccal, middle, or palatal, and the buccal type was further classified into subtypes I, II, and III. In addition, the buccolingual inclination of the tooth and buccal bone thickness were evaluated. Results: A majority of the maxillary incisors were positioned more buccally within the alveolar bone, and only 2 lateral incisors(0.5%) were positioned more palatally. The angulation of buccal subtype III was the greatest and that of the middle type was the lowest. Most of the maxillary incisors exhibited a thin facial bone wall, and the lateral incisors had a significantly thinner buccal bone than the central incisors. The buccal bone of buccal subtypes II and III was significantly thinner than that of buccal subtype I. Conclusion: A majority of the maxillary incisor roots were positioned close to the buccal cortical plate and had a thin buccal bone wall. Significant relationships were observed between the root position in the alveolar bone, the angulation of the tooth in the alveolar bone, and buccal bone thickness. CBCT analyses of the buccal bone and sagittal root position are recommended for the selection of the appropriate treatment approach.

Bone changes in the mandibular incisors after orthodontic correction of dental crowding without extraction: A cone-beam computed tomographic evaluation

  • Valerio, Claudia Scigliano;Cardoso, Claudia Assuncao e Alves;Arauujo, Eustaquio Afonso;Zenobio, Elton Goncalves;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • 제51권2호
    • /
    • pp.155-165
    • /
    • 2021
  • Purpose: This study aimed to evaluate changes of the alveolar bone and interdental bone septum of the mandibular incisors through cone-beam computed tomography (CBCT) after orthodontic treatment of mandibular dental crowding without dental extraction. Materials and Methods: The sample consisted of 64 CBCT images(32 pre-treatment and 32 post-treatment) from 32 adult patients with class I malocclusion and an average age of 23.0±3.9 years. The width and height of the alveolar bone and interdental septum, the distance between the cementoenamel junction (CEJ) and the facial and lingual bone crests, and the inclination of the mandibular incisors were measured. Results: The distance between the CEJ and the marginal bone crest on the facial side increased significantly (P<0.05). An increased distance between the CEJ and the bone crest on the facial and lingual sides showed a correlation with the irregularity index (P<0.05); however, no significant association was observed with increasing mandibular incisor inclination (P>0.05). The change in the distance between the CEJ and the marginal bone crest on the facial side was correlated significantly with bone septum height(P<0.05). Conclusion: Bone dehiscence developed during the treatment of crowding without extraction only on the incisors' facial side. Increasing proclination of the mandibular incisor was not correlated with bone dehiscence. The degree of dental crowding assessed through the irregularity index was associated with the risk of developing bone dehiscence. The interdental septum reflected facial marginal bone loss in the mandibular incisors.