• Title/Summary/Keyword: Bonding Strengthening

Search Result 155, Processing Time 0.028 seconds

Ultra Grain Refinement and High Strengthening of Deoxidized Low-Phosphorous Copper by Accumulative Roll-Bonding Process (ARB법에 의한 인탈산동의 결정립초미세화 및 고강도화)

  • Lee, Seong-Hee;Han, Seung-Zeon;Lim, Cha-Yong
    • Korean Journal of Materials Research
    • /
    • v.16 no.9
    • /
    • pp.592-597
    • /
    • 2006
  • A deoxidized low-phosphorous (DLP) copper was processed by accumulative roll-bonding (ARB) for ultra grain refinement and high strengthening. Two copper sheets 1 mm thick, 30 mm wide and 300 mm long are first degreased and wire-brushed for sound bonding. The sheets are then stacked to each other, and roll-bonded by about 50% reduction rolling without lubrication at ambient temperature. The bonded sheet is then cut to the two pieces of same dimensions and the same procedure was repeated to the sheets up to eight cycles (${\varepsilon}{\sim}6.3$). TEM observation revealed that ultrafine grains were developed after the 4th cycle, and their size decreased at higher cycles. Tensile strength of the copper increased with the equivalent strain, and it reached 547 MPa which was 3 times higher than that of the initial material. It is concluded that the ARB process is an effective method for high strengthening of the DLP copper.

The Study on Improvement of Flexural Performance of RC Beam Strengthened with CFRP Plate (탄소섬유보강판으로 보강된 철근콘크리트 보의 휨성능 개선에 관한 연구)

  • 한상훈;최만용;조홍동;박중열;황선일;김경식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.399-404
    • /
    • 2002
  • This paper presents the results cf research on improved flexural performance cf reinforced concrete beams strengthened with bonded carbon fiber reinforced polymer plate. Recently, strengthening technique with CFRP plate were almost carried out by external bonding. But current external bonding technique cf CFRP plates may result in debonding CFRP plate. Therefore, this study proposes a strengthening method that prevents or delays debonding between CFRP plates and concrete and at the same time improves the strength. For this test, there were only 14 test beams manufactured and failure load, deflection, strains and modes cf failure have been examined Test variables included the type cf strengthening, steel ratio and strengthening length, and the effects according to each test variables were analyzed. The experimental results show that the strength and stiffness cf the beam significantly increased between 34.55 and 116.51% and the increase cf the more lead-carrying capacity than the control beams.

  • PDF

Analytical and numerical studies on hollow core slabs strengthened with hybrid FRP and overlay techniques

  • Kankeri, Pradeep;Prakash, S. Suriya;Pachalla, Sameer Kumar Sarma
    • Structural Engineering and Mechanics
    • /
    • v.65 no.5
    • /
    • pp.535-546
    • /
    • 2018
  • The objective of this study is to understand the behaviour of hollow core slabs strengthened with FRP and hybrid techniques through numerical and analytical studies. Different strengthening techniques considered in this study are (i) External Bonding (EB) of Carbon Fiber Reinforced Polymer (CFRP) laminates, (ii) Near Surface Mounting (NSM) of CFRP laminates, (iii) Bonded Overlay (BO) using concrete layer, and (iv) hybrid strengthening which is a combination of bonded overlay and NSM or EB. In the numerical studies, three-dimensional Finite Element (FE) models of hollow core slabs were developed considering material and geometrical nonlinearities, and a phased nonlinear analysis was carried out. The analytical calculations were carried out using Response-2000 program which is based on Modified Compression Field Theory (MCFT). Both the numerical and analytical models predicted the behaviour in agreement with experimental results. Parametric studies indicated that increase in the bonded overlay thickness increases the peak load capacity without reducing the displacement ductility. The increase in FRP strengthening ratio increased the capacity but reduced the displacement ductility. The hybrid strengthening technique was found to increase the capacity of the hollow core slabs by more than 100% without compromise in ductility when compared to their individual strengthening schemes.

A Study for Numerical Procedure of Strengthening Capacity in Field (사용중 보강되는 부재의 보강설계법 연구)

  • 한만엽;이원창
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.861-866
    • /
    • 1998
  • This study is numerical procedure of strengthening capacity in a field structure and compare analysis data with test data. Recently, many strengthening methods are developed and used to rehabilitate existing structure. However, both theoretical background and applying techniques are not established yet. One of the most popular method is plate bonding method using either steel plate or carbon plate. This theoretical background and applying techniques are very important and those applications are differed when applied in field strengthening cases. Also depending on the analysis out come, displacement increased based n the condition of members while reaching ultimate load or failure load.

  • PDF

Study on Flexural Strengthening Capacity of FRP-Plate Strengthening System with the Velcro (벨크로를 이용한 FRP판 보강공법의 휨보강성능에 대한 연구)

  • Shin, Dong-Yoon;Hong, Geon-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.121-124
    • /
    • 2006
  • This study focuses on the flexural behavior of RC beam with externally bonding FRP reinforcement. FRP-plate strengthening system is mainly installed with an anchor-bolt. But the installation with it has several disadvantage as a complicated work, a high labor costs. To complement these disadvantage, the test is performed about improved FRP-plate strengthening system.

  • PDF

A study on development of methods to rehabilitate the damaged prestressed concrete beam using glass fiber (유리섬유를 이용한 손상된 프리스트레스트 콘크리트보의 보강공법 개발연구)

  • 한만엽;이택성;강원호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.815-820
    • /
    • 1998
  • Many composite girder bridges have been constructed for about thirty five years. Nowadays they are aged or deteriorated because of th increase in traffic and vehicle loads. In this study, the effect of strengthening with glass fiber sheet is investigated to estimate the possibility for appling for damaged prestressed concrete bridges. One normal and eight cracked specimens which had been preloaded were tested. The cracked specimens were strengthened with either external prestressing or bonding glass fiber sheet, or using both methods. The results showed that the maximum loads are almost same for both methods. So it seems that the strengthening with glass fiber sheet can be used for strengthening damaged prestressed concrete girders. It is important that proper devices should be selected to prevent glass fiber sheet from premature bonding failure below its maximum load, which is similar to end anchorage problem in external prestressing method. It is proved that the devices proposed in this paper have sufficient anchoring capability to increase load carrying capacity.

  • PDF

Development of Wedge-Type Mechanical Anchor for FRP Plate (FRP 판용 쐐기형 정착구의 개발)

  • Cho Jeong Rae;Park Young Hwan;Park Jong Sup;Yoo Young Jun;Jung Woo Tae;Kim Chul Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.80-83
    • /
    • 2004
  • The FRP plate or sheet bonding technology was widely used for strengthening deficient RC structures. The strengthened structure using FRP bonding scheme, however, experience the complex interfacial behaviour which is difficult to predict. Therefore, the unbonded scheme using some anchorage device can be is an alternative for more reliable design. In this study, wedge-type anchor for FRP plate is developed for the unbonded flexural strengthening scheme. Some parameter study using 2D finite element method is performed. The analysis parameters are taken as wedge-guide friction coefficients, wedge- FRP ,.friction coefficient and wedge inclination angle. Based on the parameter study, more efficient anchors are designed and tested. The test result show that the developed anchor assure about $80\%$ FRP strength, which is higher performance than typical bonding scheme. Last, 3D finite element analysis is performed.

  • PDF

Structural behavior on the steel beam with strengthening bonded carbon plate (카본판을 접착보강한 강재의 거동분석)

  • Sung, Ikhyun
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.1
    • /
    • pp.54-61
    • /
    • 2016
  • The use of advanced composite materials in strengthening and repair of existing structures is increasing rapidly. This paper describes an effectiveness of a bonding of carbon fiber reinforced sheets to corroded steel members for the repair. Three types of surface treatment, what we call cleaning, of corroded plate are chosen as parameters. They are "without cleaning","removal of painting by brushing" and "complete removal of painting". From the experimental study, the following findings are obtained. 1) When the steel plate is subjected to tensile force, carbon fiber sheets adhered to the painted steel gives a higher strength against peeling compared to that of the plate without painting, 2) The grade of surface treatment, or cleaning of the corroded steel plate affects the strengthening effect.

Shear Strengthening Effect of Pre-loaded RC Beams Strengthened by CFS (재하상태를 고려한 탄소섬유 보강공법의 전단 보강 효과)

  • 김주연;신영수;홍건호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.709-712
    • /
    • 1999
  • This paper was aimed to investigate the shear strengthening effect of the pre-loaded reinforced concrete beams strengthened by carbon fiber sheet (CFS). Main tet parameters was the magnitude of pre-loading at the time of the retrofit and the strengthening method of carbon fiber sheet. A series of nine specimens was tested to evaluate the corresponding effect of each parameters such as maximum load capacity, load-deflection relationship, and failure mode. The results of this study showed that the failure mode is bonding failure between the concrete and the CFS before the tensile failure strain of the CFS is reached.

  • PDF

A study on Development of Methods to Rehabilitate the Damaged Prestressed Concrete beam Using Glass Fiber (유리섬유를 이용한 손상된 프리스트레스트 콘크리트 보의 보강공법 개발연구)

  • Kang, Won-Ho;Han, Man-Yop;Lee, Taek-Sung;Rhu, Young-Min
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.167-175
    • /
    • 1999
  • Many composite girder bridges have been constructed for about thirty five years. Nowadays they are aged or deteriorated because of the increase in traffic and vehicle loads. In this study, the effect of strengthening with glass fiber sheet is investigated to estimate the possibility for applying to damaged prestressed concrete bridges. One normal and eight cracked specimens which had been preloaded were tested. The cracked specimens were strengthened with either external prestressing or bonding glass fiber sheet, or using both methods. The results showed that the maximum loads are almost same for both methods. So it seems that the strengthening with glass fiber sheet can be used for strengthening damaged prestressed concrete girders. It is important that proper devices should be selected to prevent glass fiber sheet from premature bonding failure below its maximum load, which is similar to end anchorage problem in external prestressing method. It is proved that the devices proposed in this paper have sufficient anchoring capability to increase load carrying capacity.