• 제목/요약/키워드: Bond strengths

검색결과 481건 처리시간 0.024초

계면파괴인성과 콘크리트 역학적 성질의 상관관계 (Corelationship between Interfacial Fracture Toughness and Mechanical Properties of Concrete)

  • 이광명;안기석;이회근;김태근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.359-364
    • /
    • 1998
  • The interfacial zone in concrete materials is extensive, geometrically complex, and constitutes inherently weak zones that limit the concrete performance. Motar-aggregate interfaces play a major role in the fracture processing in concrete composites. Also, the interfacial bond considerably influence mechanical properties of concrete such as modulus of elasticity, strength, and fracture energy, Characterization of the interfacial properties is, therefore, essential to overcome the limitations associated with the interfaces. an objective of this paper is to investigate the corelationship between the fracture toughness of mortar-aggregate interface and the concrete properties such as strengths and elastic moduli. It is observed from the test results that interface fracture toughness is closely related with the compressive strength rather than other properties. At early ages, the development of both tensile strength and elastic modulus are much greater thatn that of both interface fracture toughness and compressive strength.

  • PDF

Economic and Fast-track Rehabilitation of Concrete Pavements and Bridge Decks

  • Ramseyer, Chris;Chancellor, Brent;Kang, Thomas H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권2호
    • /
    • pp.107-113
    • /
    • 2008
  • The last 10 years have seen considerable growth in the use of proprietary and special repair cements for concrete pavements in the state of Oklahoma. Many of these products lend themselves to "fast track" construction techniques that allow reopening to traffic within 12 hours or less. These products achieve high early strengths by accelerating the Portland cement hydration process for both Type I and Type III cements. In this paper, the important features of a durable repair which include strength, compatibility and bond or adhesion are first discussed. Then the development, testing and field implementation of the aforementioned materials are discussed including the learning curve required to implement a repair system, not just install a new material. Some of the materials discussed, while expensive on a cost per unit basis, hold great promise for economical use on fast track project.

보 소성힌지 변형을 고려한 RC보-기둥 접합부의 스트럿-타이 모델 (Strut-and-Tie Models for Shear Strength of RC Beam-Column Joints Considering Deformation of Beam Plastic Hinge)

  • 이수곤;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.397-402
    • /
    • 2003
  • This paper presents strut-and-tie models for predicting shear strength of RC interior beam-column joints considering the plastic hinge rotation of adjacent beams. On seismic design of frame system, it is controlled beams to occur plastic hinges and to be ductile so as to dissipate earthquake energy efficiently. The plastic hinge deformation of beams is used as analysis parameter in terms of strain of beam tensile bars at column face. The shear strengths of beam-column joints are evaluated by combining direct strut mechanism with truss mechanism. It is assumed that the max force transferred by direct strut mechanism is based on the strength of cracked concrete element, and that by truss mechanism is based on bond capacity.

  • PDF

가시광선과 아르곤 레이저에 의한 복합레진 중합 효과의 비교 연구 (A COMPARATIVE STUDY OF THE EFFECTIVENESS IN POLYMERIZATION OF COMPOSITE RESIN CURED WITH VISIBLE LIGHT AND ARGON LASER SOURCE)

  • 전상언;김용기
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.327-346
    • /
    • 1996
  • The purpose of this study was to evaluate the shear bond strengths, microhardness, compressive strength and contraction gap at the resin-tooth interface of two types of composite resins polymerized with visible light and argon laser sourse. The results from the present study can be summarized as follows ; 1. Resin samples polymerized either by argon laser or visible light did not show significant difference in their physical properties tested(p>.05). 2. The contraction gap at the resin tooth interface was found to be present in all samples but any significant difference between groups could not be established due to their variability. Although the superiority of argon laser over visible light in enhancing the physical properties of resin could not be elucidated in the present study, continous efforts are deemed to be worthwhile to investigate this area using different conditions and materials of experiment.

  • PDF

Self-etching Primer를 이용한 교정용 브라켓 부착시 전단결합강도와 파절양상에 관한 비교연구 (A comparative study on bond strength and adhesive failure pattern in bracket bonding with self-etching primer)

  • 김유경;이진우;차경석
    • 대한치과교정학회지
    • /
    • 제34권4호
    • /
    • pp.325-332
    • /
    • 2004
  • 본 연구의 목적은 산부식과 전처리 과정을 결합하여 접착 단계를 단순화시킨 self-etching primer의 임상적인 유용성 을 판단하고자, self-etching primer로 브라켓을 접착하는 방법과 기존의 $37\%$ 인산으로 부식하여 접착하는 방법을 사용하여, 광중합시 사용되는 광원 및 브라켓 종류에 따른 전단결합강도와 접착파절양상에 관하여 비교 연구하는 것이다. 사람의 상하악 소구치를 포매하여 만든 시편을 부식 및 전처리 방법에 따라 각각 $37\%$ 인산으로 산부식 후 Transbond XT primer를 사용하여 접착한 군과 Transbond Plus self-etching primer를 사용하여 접착한 군으로, 광원 종류에 따라 가시광선과 plasma arc light을 이용하여 중합한 군으로 나누었고, 브라켓 종류에 따라 금속브라켓과 세라믹 브라켓을 사용하여 접착한 군으로 분류하여 각 군간의 전단결합강도와 접착파절양상을 관찰하여 다음과 같은 결과를 얻었다. 1. 광원과 브라켓 종류가 동일한 조건일 때, self-etching primer를 사용하여 접착한 군과 XT primer를 사용하여 접착한 군간의 전단결합강도는 통계적으로 유의한 차가 없었다. 2. 금속브라켓을 접착한 경우, 광원과 부식 및 전처리 방법에 따른 전단결합강도는 통계적으로 유의한 차가 없었다. 3. Self-etching primer와 XT primer를 사용하여 접착한 군 모두에서 세라믹 브라켓을 사용하여 접착한 군의 전단결합 강도는 금속브라켓을 사용하여 접착한 군보다 통계적으로 유의하게 컸다(p<0.001). 4. 접착제 잔류지수는 self-etching primer를 사용하여 접착한 군과 XT primer를 사용하여 접착한 군에서 통계적인 유의한 차가 없었으며, 세라믹 브라켓을 사용하여 접착한 군에서 금속브라켓을 사용하여 접착한 군보다 유의하게 커서, 법랑질-레진 접착 계면 부위의 파절이 더 많은 것으로 나타났다. 이상의 결과로 미루어 보아 Transbond Plus self-etching primer를 사용하여 브라켓을 접착하는 것은 적절한 결합강도를 얻으면서도 사용이 간편하고 시술 시간을 단축시킬 수 있으므로 임상적으로 유용할 것으로 판단된다.

산 표면처리후 상아질과 법랑질 표면의 습윤이 결합강도에 미치는 영향 (EFFECTS OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACES ON BOND STRENGTH)

  • 이광원;박수정;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.328-341
    • /
    • 1995
  • I. Shear Bond Strength to Air-dried and Remoistened Dentin.. The effect of air-drying and remoistening of acid-conditioned dentin before priming with the primer of All-Bond 2(BISCO. INC., U. S. A.) on shear bond strength(SBS) was investigated. Ninty freshly extracted sound human molars were divided at random into 9 groups of 10 teeth each. SBSs were meaured for acid-conditioned and non-conditioned dentin to which the primer and bonding agent of All-Bond 2 and composite resin(Z-100, 3M Dental Products, U. S. A.) were applied. The following values(Mean${\pm}$ SD, MPa) were obtained for the groups conditioned with 10% phosphoric acid for 15 seconds: Group l(blot dried) $6.7{\pm}4.1$ ; Group 2(10 seconds dried) $16.1{\pm}5.3$ ; Group 3(20 seconds dried) $15.4{\pm}4.8$ ; Group 4(30 seconds dried) $15.2{\pm}6.3$ ; Group 5(10 seconds dried/remoistened) $26.4{\pm}2.6$ ; Group 6(20 seconds dired/remositened) $22.2{\pm}2.7$ ; Group 7(30 seconds dried/remoistened) $21.5{\pm}4.1$. For the non-conditioned groups the values were: Group 8 (blot dried) $13.3{\pm}2.6$ ; Group 9(10 seconds dried) $12.9{\pm}3.5$. The data were analyzed using ANOVA. In the acid-conditioned groups, mean values of SBS for the air-dried specimens(Grps. 2, 3 and 4) and the 20 and 30 seconds dried/remoistened specimens (Grps. 6 and 7) were significantly lower than that of blot dried specimens.(p<0.05) The value for 10 seconds dried/remoistened specimens (Grp. 5), however, was not statistically different compared to that of blot dried specimens.(p>0.05) In the non-conditined groups, there was no statistical difference between blot dried and 10 seconds dried specimens.(p>0.05) The results suggest that the acid-conditioned dentin surface is more vulnerable to dentin bonding when it is air-dried or even remoistened after long period of drying. II. Shear bond stengh to the moistened and primed enamel. The effect of moistening and priming of enamel compared to the air-drying of enamel on the shear bond strength of enamel bonding agent was investigated. The experiment was divided into 4 groups each containing 10 caries-free maxillary incisor teeth. Shear bond strength values were measured for the primed and non-primed enamel to which All-Bond 2 and Z-100 were applied. The following values(MPa) were obtained for the primed groups pretreated with 32 % phosphoric acid for 15 seconds. : Group 1 (10 seconds dried) $29.8{\pm}2.2$ ; Group 2(moistened) $26.8{\pm}5.4$. For the non-primed groups the values were: Group 3(10 seconds dried/primed) $27.6{\pm}5.0$ ; Group 4(mostened/primed) $28.2{\pm}3.5$. The data were subjected to statistical analysis using ANOVA. The results showed that mean shear bond strengths among the experimental groups were not statistically different. (p>0.05) Conclusively, It is suggested that the bonding ability to enamel is not decreased by the moistening and priming of the enamel.

  • PDF

Flowable Composite Resin의 미세변연누출 및 전단결합강도 (MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

법랑질 표면 처리방법에 따른 레진계 치아 고정재료의 접착강도 비교 (Comparison of adhesive strength of resinous teeth splinting materials according to enamel surface treatment)

  • 이예림;김수연;김진우;박세희;조경모
    • 구강회복응용과학지
    • /
    • 제35권2호
    • /
    • pp.72-80
    • /
    • 2019
  • 목적: 본 연구의 목적은 레진계 치아고정 재료의 법랑질 치면 처리 방법에 따른 전단결합강도와 파절 양상을 비교 분석하는 것이다. 연구 재료 및 방법: 레진계 치아고정 재료로 G-FIX, LightFix를 사용하였다. 시편 제작을 위해 소의 하악 절치 20개를 사용했다. 노출된 법랑질 표면을 4부분으로 구분하여, 각 분획 마다 37% 인산(E), 37% 인산+Adhesive resin (E+A), 37% 인산+G-premio bond (E+GP), G-premio bond (GP)로 각각의 치면 처리를 하고, 재료를 접착하였다. 만능 시험기를 이용하여 전단결합강도를 측정하였고, 시편의 파절된 표면을 현미경으로 확대하여 파절 양상을 관찰하였다. Two-way ANOVA를 이용하여 재료와 표면처리 방법 사이의 상호작용을 검증하였고 각 재료에서 표면처리 방법 사이의 비교를 위해 One-Way ANOVA test를 하고 Scheffe's test로 사후 검정 하였다. 각 표면처리 방법에서 재료 사이의 전단결합강도를 비교하기 위해 independent t-test를 하였다. 모든 통계는 95% 유의수준에서 진행하였다. 결과: 동요치 고정을 위한 G-FIX는 산부식만 시행한 후 재료를 적용해도 접착 레진을 추가적으로 사용했을 때와 유사한 전단결합강도를 보였으며 LightFix는 산부식을 시행한 후 접착 레진을 추가적으로 사용했을 때 가장 높은 전단결합강도를 보였다. 또한, G-FIX와 LightFix 모두에서 별도의 산부식 없이 자가부식 접착제만 처리했을 때 가장 낮은 전단결합강도를 보였다. 교호작용의 검증 결과 치아고정용 레진과 표면처리 방법 사이의 상호 연관됨이 관찰되었다. 파절 양상은 모든 군에서 대부분 혼합성 파절이 관찰되었다. 결론: 치아 고정용 레진인 G-FIX와 LightFix의 사용시 제조사의 지시와 같이 산부식만 시행한 후 재료를 적용해도 충분한 접착이 이루어질 것으로 생각된다.

즉시 상아질 봉쇄와 지연 상아질 봉쇄에 따른 상아질 접착의 미세인장 결합강도 비교 (The comparison of microtensile bond strength with immediate and delayed dentin sealing)

  • 이흥배;한종현;심준성;김선재
    • 대한치과보철학회지
    • /
    • 제46권4호
    • /
    • pp.372-380
    • /
    • 2008
  • 연구목적: 본 연구의 목적은 즉시 상아질 봉쇄 (immediate dentin sealing; IDS)을 시행한 경우와 지연 상아질 봉쇄 (delayed dentin sealing ; DDS)를 시행한 경우를 비교하고, 지연 상아질 봉쇄 시 상아질 접착제를 먼저 중합한 경우와 복합레진과 함께 중합한 경우에 있어서 상아질과 복합레진의 결합강도를 비교하는 것이다. 재료 및 방법: 사람의 건전한 대구치 20개의 치관부를 삭제하여 상아질 표면을 노출시켰다. 상아질 접착 후 바로 복합레진을 축조하는 과정에서 군을 4 가지로 나누었다. 대조군은 주수 하에 model trimmer를 이용하여 치관부 삭제 후 바로 2-step etch-and-rinse dentin bonding agent (ONE-STEP, Bisco, USA)를 이용하여 상아질 접착을 시행하고 복합레진 (RENEW, Bisco, USA)을 수복하였다. 실험군 A는 치아 삭제 후, Fermit을 이용한 임시수복 상태로 5일간 생리식염수에 보관하였다. 임시수복 제거 후 상아질 접착제를 도포하고 별도의 중합없이 레진을 축조하고 함께 중합하였다. 실험군 B는 치아 삭제 후, 상아질 접착제 도포 및 중합하고 임시수복을 시행하여 5일간 생리식염수에 보관하였다. 임시수복 제거 후 상아질 접착제를 도포하고 별도의 중합없이 레진을 축조하고 함께 중합하였다. 실험군 C는 치아 삭제 후, 임시수복 상태로 5일간 생리식염수에 보관하였다. 임시수복 제거 후, 상아질 접착제를 도포 및 중합하고, 레진을 축조 및 중합하였다. 각 치아를 단면적 1 $mm^2$, 길이 10-12 mm의 막대형 시편으로 절단하여, 미세인장 결합강도를 측정하였다. 측정된 결합강도는 one-way ANOVA를 이용하여 비교 분석하였으며, 사후 검증은 Scheffe test를 이용하여 분석하였다. 연구결과: 본 실험의 결과는 다음과 같다. 1. 치아 삭제 후 별도의 상아질 접착 시행 없이 임시수복하고, 레진 축조 전 상아질 접착을 도포 후 별도의 중합과정 없이 레진과 함께 중합할 경우, 상아질과의 미세인장 결합강도는 유의하게 낮은 값을 보였다 (P < .01). 2. 치아 삭제 및 임시 수복 기간 후, 상아질 접착제를 먼저 중합하고 복합 레진을 수복하는 경우와 치아 삭제 후 상아질 접착을 시행하고 수복물 장착 시 상아질 접착을 재시행하는 경우 간의 상아질에 대한 결합강도의 차이는 없었다 (P > .05).

상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구 (The study of shear bond strength of a self-adhesive resin luting cement to dentin)

  • 인희선;박종일;최종인;조혜원;동진근
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.535-543
    • /
    • 2008
  • 최근의 레진 접착시스템은 단계를 줄이고 적용과정을 간편화시키는데 주력하고 있으며, 치면에 bonding 및 conditioning 과정 없이 바로 적용 가능한, one-step의 새로운 자가 접착 레진시멘트 (self-adhesive resin luting cement)들이 소개되어 임상에 사용되고 있다. 이에 본 연구의 목적은 자가 접착 레진시멘트와 기존의 레진시멘트의 상아질에 대한 전단 결합 강도를 비교해보고, 자가 접착 레진시멘트 적용시 치면의 식각 처리 여부가 전단 결합 강도에 미치는 영향에 관하여 알아보고자 하는 것이다. 본 연구를 위해 최근 6개월 내 발치된 비교적 건전한 성인의 대구치 45개를 아크릴릭 레진으로 매몰한 다음, 800 grit SiC연마지로 연마를 시행하여 상아질을 노출시켰다. 15개의 치아를 한 군으로 하여, 세 가지 실험군으로 분류하였다. Group 1) 치면에 아무런 전처리 없이 RelyX Unicem 접착. Group 2) 치면에 인산 산부식 처리 후, RelyX Unicem 접착, Group 3) 치면에 Syntac primet + Syntac adhesive + Heliobond 처리 후 Variolink II 접착. 전처리가 완료된 치아 시편 위에 플라스틱 튜브 (직경 3 mm, 높이 3 mm)를 고정한 다음, 제조사의 지시에 따라 각 레진 시멘트를 혼합하여 링 안을 채우고, 광중합을 시행하였다. 접착이 완료된 시편은 $37^{\circ}C$ 항온수조 (증류수)에서 24시간 동안 보관 후, 만능 시험기를 이용하여 1mm/min의 cross head speed로 결합강도를 측정하였으며, 확대경 하에서 파절 양상을 분류 관찰하고, 주사전자현미경을 이용하여 미세구조를 관찰하였다. 측정결과는 SPSS WIN 12.0 프로그램을 사용하여 분석하였으며 다음과 같은 결과를 얻었다. 1. RelyX Unicem의 상아질에 대한 전단결합강도는 Variolink II와 유의한 차이를 보이지 않았다. 2. 상아질에 대한 인산 산부식 처리는 RelyX Unicem과의 전단결합강도를 낮게 하였다. 3. RelyX Unicem과 Variolink II에서는 혼합 파절의 비율이 컸으며, 전단결합강도가 낮았던 인산 산부식 처리 후 RelyX Unicem을 접착한 경우에서는 전체 시편에서 접착성 파절이 관찰되었다. 결론으로 말하면, 자가 접착 레진시멘트와 기존의 레진시멘트의 상아질에 대한 전단결합강도는 유의한 차이를 보이지 않으며, 인산 산부식 처리는 상아질에 대한 자가 접착 레진시멘트의 전단결합강도를 감소시킨다.