• 제목/요약/키워드: Bond strengths

검색결과 483건 처리시간 0.023초

Modeling the impact of corrosion rate of stirrups on seismic performance of reinforced concrete columns

  • Abbas Ghasemi;Mohamad Sobhani
    • Earthquakes and Structures
    • /
    • 제24권3호
    • /
    • pp.183-192
    • /
    • 2023
  • It is essential to properly understand the seismic behavior of reinforced concrete (RC) columns confined by stirrups that experience different corrosion rates. The current study investigated the effect of seismic performance indicators such as strength loss, energy dissipation rate, ductility and hysteresis damping on specimens and models for different stirrup corrosion rates. Analysis revealed the adverse effects of corrosion on the bond performance between the concrete and steel bars which affected the seismic performance of the columns. It was found that with increasing corrosion rate, ductility and energy dissipation of the specimens decreased. Compared with the uncorroded specimen, the ductility factor and energy dissipation decreased observably, by 22.89% and 60.64%, respectively. An attenuation relationship is proposed for the corrosion rate of the stirrups for different stirrup yield strengths, concrete compressive strengths, concrete covers and stirrup spacing.

초기양생중에 수평연속진동을 받은 콘크리트의 강도특성 (Strength Characteristics of Concrete Subjected In Horizontal Continuous Vibration During Initial Curing)

  • 장희석;김명식;김종수;한중기
    • 콘크리트학회논문집
    • /
    • 제13권5호
    • /
    • pp.423-429
    • /
    • 2001
  • 본 연구에서는 초기양생 중에 수평연속진동을 받는 콘크리트 시험체에 대하여 강도특성이 조사되었다. 실험변수로서 진동속도(0.25, 0.5, 1, 2, 4 kine)와 진동가력시간(3, 6, 12, 24 hrs)을 택하였다. 압축강도, 쪼갬인장강도 및 부착강도가 비교되었으며, 밀도와 재료분리현상이 조사되었다. 실험 결과, 진동속도 0.25 kine에서는 진동가력시간에 관계없이 모든 시험체에서 강도의 감소가 거의 발생하지 않았고, 또한 진동속도 0.5 kine에서 3시간의 진동을 받은 경우에도 강도의 감소가 없었다. 전체 시험체에 있어서 밀도가 증가하였으며, 재료분리현상은 발견되지 않았다.

Alloy 617 확산용접재의 고온 인장강도 (High-Temperature Tensile Strengths of Alloy 617 Diffusion Weldment)

  • 사인진;황종배;김응선
    • 한국압력기기공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.15-23
    • /
    • 2018
  • A compact heat exchanger is one of critical components in a very high temperature gas-cooled reactor (VHTR). Alloy 617 (Ni-Cr-Co-Mo) is considered as one of leading candidates for this application due to its excellent thermal stability and strengths in anticipated operating conditions. On the basis of current ASME code requirements, sixty sheets of this alloy are prepared for diffusion welding, which is the key technology to have a reliable compact heat exchanger. Optical microscopic analysis show that there are no cracks, incomplete bond, and porosity at/near the interface of diffusion weldment, but Cr-rich carbides and Al-rich oxides are identified through high resolution electron microscopic analysis. In high-temperature tensile testing, superior yield strengths of the diffusion weldment compared to the code requirement are obtained up to 1223 K ($950^{\circ}C$). However, both tensile strength and ductility drop rapidly at higher temperature due to the insufficient grain boundary migration across the interface of diffusion weldment. Best fit curves for minimum yield strength and average tensile strength are drawn from the experimental tensile results of this study.

지르코니아 필러를 첨가한 복합레진의 기계적 성질에 관한 연구 (A STUDY ON THE MECHANICAL PROPERTIES OF EXPERIMENTAL, COMPOSITES CONTAINING ZIRCONIA FILLER)

  • 류경희;최호영;최경규;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.421-434
    • /
    • 2000
  • The purpose of this study was to evaluate the influences of incorporation of zirconium-silicate on diametral tensile strength, shear bond strength to the enamel, and depth of cure of 7 experimental composites. One group contained no filler(group 1 or control group), and the other 6 composites contain 75% filler in which zirconium-silicate(Zr-Si) were 0%, 2%, 4%, 6%, 8%, 10% with reduced contents of silica filler, respectively. Both of fillers were treated with 1% silane (${\gamma}$-methacryloxypropyltrimethoxy silane). Light curable monomers were prepared by mixing Bis-GMA and TEGDMA with 3:1 ratio and adding camphoroquinone(CQ) 0.6% with tertiary amine 0.3%. Diametral tensile strengths of specimens with $3mm{\times}6mm$ were measured with Instron (No.4467, USA) with 1mm/min crosshead speed. Shear bond strengths of composites which bonded to bovine enamel etched with 37% phosphoric acid were measured at Instron Testing Machine with as same speed as in diametral tensile strengths. Depth of cure were measured by a method that composite was filled in cylinder mold, illuminated at one side. and uncured composite was removed with acetone, and the residual thickness of composite was measured. Following results were obtained ; 1. Composites containing 0%, 2%, or 4% zirconium-silicate filler(group 2, 3 and 4) showed the statistically higher diametral tensile strength than the others. (p<0.05) 2. Increase of zirconium-silicate filler contents reduced the diametral tensile strength of experimental composites. ($r^2$=0.8721, p=0.0002) 3. Increase of zirconium-silicate filler contents did not affect the shear bond strength of experimental composites. ($r^2$=0.2815, p=0.4067) 4. Increase of zirconium-silicate filler contents reduced significantly the depth of cure of experimental composites. ($r^2$=0.9700, p<0.0001) These results mean that the mechanical properties of composites could not be improved by incorporation of small amount of zirconium-silicate filler. Also, the increased contents of zirconium-silicates fillers was found to reduce the diametral tensile strength and depth of cure.

  • PDF

인산용액의 농도 및 적용시간 차이에 따른 상아질 표면의 형태적 변화 (MORPHOLOGIC CHANGE OF DENTIN SURFACE ACCORDING TO THE DIFFERENCE IN CONCENTRATION AND APPLICATION TIME OF PHOSPHORIC ACID)

  • 김명수;온영석;이광원;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.141-161
    • /
    • 1998
  • The depth and patterns of demineralization according to the difference in concentration and application time of phosphoric acid were observed through the transmission electron microscope, and shear bond strengths to the acid -conditioned dentin were then measured and compared with the TEM results. To investigate the influence of polymer addition into the phosphoric acid and the effect of difference in concentration and application time of the acid, the specimens were randomly divided into 9 groups. Among the specimens, the exposed dentin surfaces were acid-conditioned with 10% polymer-thickened phosphoric acid(All Bond 2, Bisco, U.S.A.) and aqueous 10%, 20%, 30%, 40% phosphoric acid for 20 seconds, The rest of the specimens were acid-conditioned with 10% phosphoric acid for 15s, 30s, 60s, 120s respectively. The specimens were immersed in 4% glutaraldehyde in 0.1M sodium cacodylate buffer and postfixed with 1 % osmium tetroxide without decalcification and then observed under a JEOL Transmission Electron Microscope(JEM 1200 EX II, Japan). After the specimens were acid-conditioned as the above, primer and adhesive resin were applied to blot-dried dentin and shear bond strengths were then measured and analysed. The results were as follows : 1. The intertubular demineralization depth of 4.0-$5.0{\mu}m$ in 10% polymer-thickened phosphoric acid gels was similar or slightly deeper than that of 4.0-$4.5{\mu}m$ in aqueous 10% phosphoric acid solution. 2. The intertubular demineralization depth of aqueous 20%, 30% and 40% phosphoric acid solution was 6.5-$7.0{\mu}m$, 6.5-$7.5{\mu}m$ and 9.0-$15.0{\mu}m$ respectively. It showed that the depth of dentin demineralization is partly related to the concentration of phosphoric acid solution. 3. The intertubular demineralization depth of aqueous 10% phosphoric acid solution in application time for 15s, 30s, 60s and 120s was 2.5-$3.0{\mu}m$, 4.0-$6.0{\mu}m$, 6.5-$7.0{\mu}m$ and 8.5-$14.0{\mu}m$ respectively. It showed that the depth of dentin demineralization is directly related to the application time of phosphoric acid solution. 4. The partially demineralized dentin layer between demineralized collagen layer and unaffected dentin was showed to a width of 0.5-$1.0{\mu}m$ in lower concentration groups treated with aqueous 10% phosphoric acid for 20s, 60s, 120s and 20% phosphoric acid for 20s. 5. The demineralization effect at the border of intertubular-peritubular junction was less evident than that in the peritubular and intertubular dentin. The collagen fibers in the intertubular dentin had a random orientation, whereas those that lined the tubules were circumferentially aligned. The cross-linkage of dentinal collagen in demineralized collagen layer was clearly seen. 6. A statistically significant difference of bond strengths according to the difference in phosphoric acid concentration did not exist among the groups treated with 10%, 20%, 30% and 40% acid solution (P>0.05). However, bond strengths to the treated dentin with 10% phosphoric acid solution for 30s were significantly higher than that for 120s (P<0.05).

  • PDF

다양한 접착 시스템 및 포스트의 표면 처리가 섬유 강화 포스트의 접착 강도에 미치는 영향 (Effect of different adhesive systems and post surface treatments on the push-out bond strengths of fiber-reinforced post)

  • 김민우;안진희;김이경;심혜원
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.218-225
    • /
    • 2016
  • 목적: 본 연구에서는 자가-접착 레진 시멘트의 접착 강도에 포스트의 표면 처리와 접착 시스템이 미치는 영향을 조사하고자 하였다. 재료 및 방법: 비슷한 치근 길이를 가진 48개의 사람 상악 단근치를 사용하여 160개의 시편을 제작하고 접착 시스템에 따라 4개의 군으로 분류하였다(no adhesive, Adper Single Bond 2, Clearfil SE Bond, Clearfil S3). 각 군은 포스트 표면 처리 방식에 따라 다시 4개의 군으로 세분하였다(no treatment, sandblast, silane, sandblast and silane). 포스트를(Parapost Fiber White) Rely X Unicem을 사용하여 접착하였다. 치아를 장축에 수직으로 1 mm 두께로 절단 하였다. Push-out test를 0.5 mm/분의 crosshead speed로 시행하였다. 2-way ANOVA, 1-way ANOVA 검정을 시행하였고 Tukey test를 통한 사후 검정을 시행하였다(${\alpha}=0.05$). 결과: Tukey test를 통한 사후 검정에서 접착 시스템에 따른 차이가 나타났다. Clearfil SE Bond가 가장 높은 접착 강도를 나타내었다. 결론: 상아질에 Clearfil SE bond를 사용하고 포스트를 실란 처리시 가장 높은 접착 강도를 나타내었다.

냉간압연강판 접착 및 기계적 프레스 접합부의 피로강도 평가 (Fatigue Strength Evaluation of Adhesive Bonded and Mechanical Pressed Joints of Cold Rolled Steel Sheet)

  • 김호경
    • 한국안전학회지
    • /
    • 제25권1호
    • /
    • pp.1-8
    • /
    • 2010
  • The tensile and fatigue experiments were conducted with tensile-shear specimens for investigating the strength of adhesive bonded and mechanical press joints of SPCC steel sheet used in the field of the automobile industry. The optimal punch press force was evaluated 50kN for combining epoxy adhesive bonding and mechanical press joining with a diameter of 8.3mm using SPCC sheet with a thickness of 0.8mm. The combining epoxy adhesive bonding and mechanical press joining exhibits the maximum tensile force of 750N. The fatigue strengths of the combination of adhesive bond and mechanical press joint and pure adhesive joint were evaluated 370N and 320N at 106cycles, respectively. These values correspond to 22% and 20% of their maximum tensile forces, respectively. However, the fatigue strength of the combination of adhesive bond and mechanical press joining was much lower than that of pure mechanical press joining.

측압을 받는 철근의 부착거동 (Bond Behavior of Reinforcing Bars Subject to Lateral Pressure)

  • 김강수;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.299-305
    • /
    • 1995
  • In this study the influcence of the lateral pressure on bond behavior of reinforcing barshas been investigaed experimentally. A total of 36 specimens has been tested at the laboratory. The tests have been carried out for the uniaxial and biaxial pressures of the intensities of 0, 5, 10, 20 and 40kg/$\textrm{cm}^2$. the compressive strengths of the specimens are either 360 or 520 kg/$\textrm{cm}^2$, and two kinds of bars, round and deformed, have been used. Based on the test results, linear regression equations have been proposed, and the comparisons between test results and the regression calculations have been made.

  • PDF

시스템함수를 실현하는 동적시스템의 물리구조에 관하여 (physical structure of dynamic systems to implement a given system function)

  • 박전수;김종식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.294-298
    • /
    • 1996
  • This paper presents an attempt to find the physical structure of dynamic systems which achieves the behavior of a given system function. The scheme pursued by te paper would be regarded as synthesizing dynamic systems, and a method to synthesize them analytically is proposed by means of bond graph prototypes. The method proposed adopts several concepts used to synthesize networks in the electrical field, but yet demonstrates its own strengths such as the freedom from the causality assignment and determination of junction types. Also, it is shown that this method has further advantages in reticulating a given specification into feedforward and feedback expansions relative to electrical network synthesis and the method introduced by Redfield. The proposed method is examined through an example to trace the outline of the analytical synthesis of dynamic systems using bond graph prototypes.

  • PDF

접착전단시험을 적용한 자가치료제의 접착특성 평가 (Evaluation of Bond Strength for Self-Healing Agents Using Modified Single Lap Shear Test)

  • 허광수;박희원;이종근;윤성호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.266-269
    • /
    • 2004
  • In this study, bond strengths for the self-healing agents were evaluated through the modified lap shear test in order to suggest the optimal healing conditions for the repair of polymeric composites. The healing agents of DCPD, ENB, and their mixtures were activated with Grubbs' catalysts. According to the results, the mixture of DCPD and ENB gave better opportunity than DCPD only due to the rapid acivation with catalyst in view of the economic and practical use.

  • PDF