• Title/Summary/Keyword: Bond Properties

Search Result 1,133, Processing Time 0.028 seconds

Bond and ductility: a theoretical study on the impact of construction details - part 1: basic considerations

  • Zwicky, Daia
    • Advances in concrete construction
    • /
    • v.1 no.1
    • /
    • pp.103-119
    • /
    • 2013
  • The applicability of limit analysis methods in design and assessment of concrete structures generally requires a certain plastic deformation capacity. The latter is primarily provided by the ductility of the reinforcement, being additionally affected by the bond properties between reinforcing steel and concrete since they provoke strain localization in the reinforcement at cracks. The bond strength of reinforcing bars is not only governed by concrete quality, but also by construction details such as bar ribbing, bar spacing or concrete cover thickness. For new concrete structures, a potentially unfavorable impact on bond strength can easily be anticipated through appropriate code rules on construction details. In existing structures, these requirements may not be necessarily satisfied, consequently requiring additional considerations. This two-part paper investigates in a theoretical study the impacts of the most frequently encountered construction details which may not satisfy design code requirements on bond strength, steel strain localization and plastic deformation capacity of cracked structural concrete. The first part introduces basic considerations on bond, strain localization and plastic deformation capacity as well as the fundamentals of the Tension Chord Model underlying the further investigations. It also analyzes the impacts of the hardening behavior of reinforcing steel and concrete quality. The second part discusses the impacts of construction details (bar ribbing, bar spacing, and concrete cover thickness) and of additional structure-specific features such as bar diameter and crack spacing.

Bonding of nano-modified concrete with steel under freezing temperatures using different protection methods

  • Yasien, A.M.;Bassuoni, M.T.
    • Computers and Concrete
    • /
    • v.26 no.3
    • /
    • pp.257-273
    • /
    • 2020
  • Concrete bond strength with steel re-bars depends on multiple factors including concrete-steel interface and mechanical properties of concrete. However, the hydration development of cementitious paste, and in turn the mechanical properties of concrete, are negatively affected by cold weather. This study aimed at exploring the concrete-steel bonding behavior in concrete cast and cured under freezing temperatures. Three concrete mixtures were cast and cured at -10 and -20℃. The mixtures were protected using conventional insulation blankets and a hybrid system consisting of insulation blankets and phase change materials. The mixtures comprised General Use cement, fly ash (20%), nano-silica (6%) and calcium nitrate-nitrite as a cold weather admixture system. The mixtures were tested in terms of internal temperature, compressive, tensile strengths, and modulus of elasticity. In addition, the bond strength between concrete and steel re-bars were evaluated by a pull-out test, while the quality of the interface between concrete and steel was assessed by thermal and microscopy studies. In addition, the internal heat evolution and force-slip relationship were modeled based on energy conservation and stress-strain relationships, respectively using three-dimensional (3D) finite-element software. The results showed the reliability of the proposed models to accurately predict concrete heat evolution as well as bond strength relative to experimental data. The hybrid protection system and nano-modified concrete mixtures produced good quality concrete-steel interface with adequate bond strength, without need for heating operations before casting and during curing under freezing temperatures down to -20℃.

A critical steel yielding length model for predicting intermediate crack-induced debonding in FRP -strengthened RC members

  • Dai, Jian-Guo;Harries, Kent A.;Yokota, Hiroshi
    • Steel and Composite Structures
    • /
    • v.8 no.6
    • /
    • pp.457-473
    • /
    • 2008
  • Yielding of the internal steel reinforcement is an important mechanism that influences the Intermediate Crack-induced debonding (IC debonding) behavior in FRP-strengthened RC members since the FRP is required to carry additional forces beyond the condition of steel yielding. However, rational design practice dictates an appropriate limit state is defined when steel yielding is assured prior to FRP debonding. This paper proposes a criterion which correlates the occurrence of IC debonding to the formulation of a critical steel yielding length. Once this length is exceeded the average bond stress in the FRP/concrete interface exceeds its threshold value, which proves to correlate with the average bond resistance in an FRP/concrete joint under simple shear loading. This proposed IC debonding concept is based on traditional sections analysis which is conventionally applied in design practice. Hence complex bond stress-slip analyses are avoided. Furthermore, the proposed model incorporates not only the bond properties of FRP/concrete interface but also the beam geometry, and properties of steel and FRP reinforcement in the analysis of IC debonding strength. Based upon a solid database, the validity of the proposed simple IC debonding criterion is demonstrated.

A Study on the high temperature oxidation behavior of zirconia plasma coatings on Haselloy X (Zirconala 용사된 Hastelloy X의 고온산화거동)

  • 김재철;신억균;박영규;최시경;김길무
    • Journal of the Korean institute of surface engineering
    • /
    • v.30 no.4
    • /
    • pp.285-297
    • /
    • 1997
  • Finned segment, with which are lined inner wall of the turbine combustors, are subject to severe degradation when they are exposed to a hostile environmment at elevated temperature. To protect the finned segment from this environment and to maintain good mechanical properties of components at high temperature, they are preferred to be coated. The most governing factor for the durability of coatings used in the high temperature is the microstructure of coatings; these are splat from, distibution of microcacks, size and distribution of pores, thickness of coating layer, adhesion between coating layer, and oxidation of band coating. In this study, based on the evaluation of the imported finned segment, new finned segment segment was manufactured with optimum plasma spraying parameters, and their properties were examined. Using $ZrO_2(8wt$Y_2O_3)$,/TEX> powder for ceramic coating and 67Ni-22Cr-10Al-0.5Y mixing powder for bond coating, thickness of ceramic and bond coating layer were varied in order to find optimum condition, the results showed that B2T4(bond coating : 100~250$\mu\textrm{m}$, ceramic coating : 250~300$\mu\textrm{m}$) was the best among the specimens tested. Compared to the imported finned segment, B2T4 has better bond strength, hardness, and isothermal and cyclic oxidation resistance.

  • PDF

Post-Thermal Exposure Bond Strength Properties of CFRP and GFRP in Concrete (콘크리트 고온 가열 이후 CFRP와 GFRP의 부착강도 특성)

  • Kim, Ju-Sung;Jeong, Su-Mi;Kim, Young-Jin;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.5
    • /
    • pp.509-517
    • /
    • 2023
  • The surge in FRP(Fiber Reinforced Plastic) research signifies the industry's pursuit to counteract the longstanding issue of rebar corrosion. Notably, Carbon Fiber Reinforced Plastic(CFRP) emerges as a commendable alternative, given its superior resistance to both corrosion and chemical interactions, thus positing itself as a potential replacement for traditional steel rebars. However, the layered composition of fibers and resin in CFRP flags a notable susceptibility to elevated temperatures. Despite its promise, comprehensive studies elucidating the full spectrum of CFRP properties remain ongoing. In this investigative study, we meticulously assessed the bond strength of CFRP post-exposure to high thermal conditions. Our findings underscored a parity in bond strength amongst silica sand-coated CFRP, rib-type CFRP, and Glass Fiber Reinforced Plastic(GFRP).

Study on Adhesive Properties by Hot-air Welding of Polyvinyl Chloride Waterproof Sheet Using used vinyl & used cable in Rural Area (농촌의 폐비닐과 폐전선을 활용한 폴리염화비닐 방수시트의 열풍용착에 의한 접착특성에 관한 연구)

  • Ko, Jin-Soo;Kim, Byung-Yun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.16 no.4
    • /
    • pp.75-81
    • /
    • 2014
  • In this study, we have intended to provide the related construction manuals with technical materials and to reduce the defects in the on-site construction, with reviewing the adhesive properties of joint parts according to change of temperature and speed of hot-air sealer for the products that have been made of polyvinyl chloride(PVC) materials in the single waterproof sheet. The result from the experiment is shown as following. 1) Bond strength was shown as high as the welding speed became slower. For the hot-air welding velocity with 3~6m/min, a stable bond strength has been shown in the range of the hot-air welding temperature with $175{\sim}210^{\circ}C$, while it has been shown in the range of the hot-air welding temperature with $210^{\circ}C$, when the hot-air welding velocity is between 9~12m/min. 2) If the hot-air welding temperature is lower, the adhesive strength has been shown as higher in the section where the hot-air welding velocity is low, while the adhesive strength has been also shown as higher in the section where the velocity is fast as the hot-air welding temperature becomes higher. The highest bond strength has been shown in the velocity with 3m/min for the hot-air welding temperature with $140{\pm}10^{\circ}C$, which is rather low. At $175{\pm}10^{\circ}C$, a high bond strength has been shown in the velocity with 3~6m/min, while the high bond strength has been shown in the velocity with 6~9m/min at $210{\pm}10^{\circ}C$.

Experimental Study on Bond Strength between Carbon Fiber Sheet and Concrete (탄소섬유쉬트와 콘크리트의 부착강도 실험연구)

  • 유영찬;최기선;최근도;이한승;김긍환
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.168-174
    • /
    • 2001
  • Carbon fiber sheet(CFS) has been widely used for strengthening of the concrete building structures due to its excellent physical properties such as high strength, light weight and high durability. Bond strength or behavior, on the other hands, between carbon fiber sheet and concrete is very important in strengthening the concrete member using CFS. Therefore the bond failure mechanism between CFS and concrete should be fully verified and understood. This study is to investigate the bond strength of CFS to the concrete by the direct pull-out test and the tensile-shear test. In the direct pull-out tests, the bond strength under the various environmental conditions such as curing temperature, surface condition on concrete and water content of concrete are evaluated. Also, the effective bond length, lu and the average bond stress, $\tau$y are examined in the tensile-shear tests. Based on the test results, it is concluded that the curing temperature is the most critical element for the bond strength between CFS and concrete. And, the proper value of lu and $\tau$y is recommended with 15 cm and 9.78∼ 11.88 kgf/$\textrm{cm}^2$ respectively.

Evaluation of the Organic Linings at Gas Desulfurization System (탈황 설비용 유기 라이너의 평가)

  • Song, Yo-Seung;Kwan, Hyun-Ok;Jho, Nam-In
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1178-1182
    • /
    • 2012
  • The organic linings at flue gas desulfurization systems (FGD system) in power plant have the excellent chemical properties but, lose the anticorrosive properties according to the aging with environment conditions. The properties of the organic linings depend on the manufacturing company. Therefore, the basic properties of organic linings for the preestimate of life time should be examined by conducting the aging and the bond strength test according to temperature. The pre-aging samples were compared with the post-aging samples. The temperature conditions of the aging process were 70, 150 and $200^{\circ}C$. The bond strength was calculated and the cross sections of fracture surface were examined by optical microscope and SEM. The $T_g$ was examined by DSC, DTA and TGA.

Influence of Heat Treatment on the Mechanical Properties in Various Weld Zone of the Structural Alloy Steel (구조용(構造用) 합금강(合金鋼) 용접(熔接) 각부위(各部位)의 열처리(熱處理)에 따른 기계적(機械的) 성질(性質) 변화(變化)에 관(関)한 실험적(實驗的) 연구(硏究))

  • Sim, Sang Woo;Lee, Seung Kyu;Min, Young Bong
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.76-82
    • /
    • 1985
  • To investigate the influence of annealing heat treatment on the mechanical properties at the various weld zone, an experimental study was performed for the structural alloy steel. The results obtained from the experimental works are as follows: 1. Hardness and tensile strength showed the highest value at the heat affected zone, which was 5mm apart from bond zone. With increasing of annealing temperature, hardness and tensile strength were decreased at every weld zone, and bound in heat affected zone was increased. 2. Impact strength was the highest at the filler metal, and increased with increment of annealing temperature at filler metal and base metal. However, both at bond and heat affected zones, impact strength was increased from $700^{\circ}C$ of annealing temperature, and was decreased again over $900^{\circ}C$. 3. Mutual relationship between the mechanical properties at filler and base metals showed a similar linearty to that the common structural steel did. However, it varied unsteadly both at bond and heat affected zones. 4. It may be concluded that proper annealing temperature is $700^{\circ}C$ from the viewpoint of hardness, tensile and impact strength.

  • PDF

Microwave Dielectric Properties of 0.95Ca0.85Nd0.1TiO3−0.05LnAlO3 (Ln=Sm, Dy, Er) Ceramics

  • Kim, Eung-Soo;Jeon, Chang-Jun
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.10
    • /
    • pp.537-541
    • /
    • 2007
  • Microwave dielectric properties of $0.95 Ca_{0.85}Nd_{0.1}TiO_3-0.05LnAlO_3$ (Ln=Sm, DH, Er) were investigated as a function of sintering temperature and lanthanide ion type. A single perovskite phase with an orthorhombic structure was obtained throughout the entire range of composition. The dielectric constant (K) was dependent upon the dielectric polarizabilities and the B-site bond valence in the $ABO_3$ perovskite structure. The quality factor (Qf) of the specimens with $ErAlO_3$ was smaller than those with $SmAlO_3\;and/or\;DyAlO_3$ due to the smaller grain size. The temperature coefficient of resonant frequency (TCF) could be controlled from $107.28ppm/^{\circ}C$ at Ln=Sm to $87.23ppm/^{\circ}C$ at Ln=Er due to the changes of B-site bond valence in the $ABO_3$ perovskite structure.