• Title/Summary/Keyword: Bolus tracking

Search Result 10, Processing Time 0.024 seconds

A Study on the Mitigation of the Exposure Dose Applying Bolus Tracking in Brain Perfusion CT Scan (뇌 관류 CT검사에서 BolusTracking기법을 적용한 피폭선량 저감화에 관한 연구)

  • Kim, Ki-Jeong;Jung, Hong-Ryang;Lim, Cheong-Hwan;Hong, Dong-Hee;Shim, Jae-Goo;You, In-Gyu
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.353-358
    • /
    • 2014
  • This study was conducted to analyze the patient's exposed dose targeting the patients who had acute ischemic stroke symptoms and CT brain perfusion scan, by comparing fixed time technique and bolus tracking technique which was provided by the manufacturer and to identify the Time graph to implement the usability of contrast medium's tracking technique the best contrast enhancement intervals. $CTDI_{VOL}$ of PCT in patient appeared to be 431.72mGy in fixed scan delay protocol, whereas 323.61mGy in Bolus tracking technique. The value of DLP appeared to be $1243.47mGy{\cdot}cm$ in fixed scan delay protocol, whereas $932mGy{\cdot}cm$ in Bolus tracking technique. Time graph appeared to be various in fixed scan delay protocol, whereas the optimal time graph could be obtained in Bolus tracking. The exposure dose could be reduced by 25% applying Bolus tracking technique when taking brain perfusion CT scan.

A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique (Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구)

  • Lee, Seung yong;Han, Dong kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • The purpose of this study is to find out the factors that affect the patient's exposure dose during the abdominal CT scan using the bolus tracking technique, and reducing the radiation exposure to the patient during the abdominal CT scan using the bolus tracking technique by adjusting the delay time according to the corresponding factor. The experiment was divided into two parts, and the first experiment was conducted with 300 patients There were 188 males and 112 females, and their average age was 58±12.18(19~85). In the second experiment, 150 subjects (100 males and 50 females) who were undergoing their follow-up examination among the first experiment subjects, and the difference in dose before and after was compared by applying the delay time according to the influencing factor. As a result of the first experiment, there was a relationship between the arrival time of the contrast media and the heart rate, and it was found that the arrival time decreased as the heart rate increased for both men and women. As a result of the second experiment, the average dose of CTDIvol and DLP before/after applying the delay time according to the heart rate decreased 4.98 mGy and 5.33 mGy·cm in the male group, and 3.54 mGy and 3.88 mGy·cm in the female group. By applying proper delay time according to the patient's heart rate during abdominal CT scan with the bolus tracking technique, the radiation exposure dose of the patient can be reduced.

Detection for Contrast Media Extravasation using Bolus Tracking Systems of CT (CT Bolus Tracking System을 이용한 조영제의 혈관외유출 검출)

  • Kweon, Dae-Cheol;Lee, Yong-Gu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.137-142
    • /
    • 2016
  • When injecting intravenously of CT inspection, the effusion of the contrast meium can induce the tissue damage with the blood vessel outside. We detect extravasation which is generated in the course where we inject the contrast medium into the blood vessel. And we use the bolus tracking system for the detection of that. By using MPR and VR images, moreover we detected the extravasation in order to prevent the tissue damage. In order to detect the effusion of the contrast medium, we used 16-MDCT and 64-MDCT. Three dimensional images about the outflow of the blood vessel can provide the treatment information which is important in the patient treatment. Moreover we applied the image processing technique in order to improve sharpness between contrast media and organization. And sharpness and contrast was improved.

At the time of inspection CT cerebral blood flow in patients with acute ischemic stroke, a comparative study of Bolus Tracking Technique and Fixed Time Technique (급성기 허혈성 뇌졸중 환자의 뇌 관류 CT검사 시 고정시간기법과 조영제 추적기법의 비교 연구)

  • Kim, Ki-Jeong;Jeong, Hong-Ryang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2013.05a
    • /
    • pp.217-218
    • /
    • 2013
  • 급성기 허혈성 뇌졸중 증상이 있는 뇌 관류 CT검사를 시행한 환자를 대상으로 장비사가 제시한 고정 시간 기법(fixed time technique)과 조영제 추적 기법(bolus tracking technique)을 비교하여 환자의 피폭선량을 분석하고자 하였으며 조영제 추적 기법의 유용성과 최적의 조영증강 구간을 구현하는 Time graph를 알아보기 위한 것이다.

  • PDF

Quantification of Cerebral Blood Flow Measurements by Magnetic Resonance Imaging Bolus Tracking

  • Park Byung-Rae
    • Biomedical Science Letters
    • /
    • v.11 no.2
    • /
    • pp.129-134
    • /
    • 2005
  • Three different deconvolution techniques for quantifying cerebral blood flow (CBF) from whole brain $T2^{\ast}-weighted$ bolus tracking images were implemented (parametric Fourier transform P-FT, parametric single value decomposition P-SVD and nonparametric single value decomposition NP-SVD). The techniques were tested on 206 regions from 38 hyperacute stroke patients. In the P-FT and P-SVD techniques, the tissue and arterial concentration time curves were fit to a gamma variate function and the resulting CBF values correlated very well $(CBF_{P-FT}\;=\;1.02{\cdot}CBF_{p-SVD},\;r^2\;=\;0.96)$. The NP-SVD CBF values correlated well with the P-FT CBF values only when a sufficient number of time series volumes were acquired to minimize tracer time curve truncation $(CBF_{P-FT}\;=\;0.92{\cdot}CBF_{NP-SVD},\;r^2\;=\;0.88)$. The correlation between the fitted CBV and the unfitted CBV values was also maximized in regions with minimal tracer time curve truncation $(CBV_{fit}\;=\;1.00{\cdot}CBV_{ Unfit},\;^r^2\;=\;0.89)$. When a sufficient number of time series volumes could not be acquired (due to scanner limitations) to avoid tracer time curve truncation, the P-FT and P-SVD techniques gave more reliable estimates of CBF than the NP-SVD technique.

  • PDF

A Study on the Radiation Exposure Dose of Brain Perfusion CT Examination a Phantom (Phantom을 이용한 뇌 관류 CT검사에서 방사선 피폭선량에 관한 연구)

  • Jung, Hong-Rynag;Kim, Ki-Jeong;Mo, Eun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.287-294
    • /
    • 2015
  • The purpose of this study, was Let's examine the exposure dose at the time of cerebral blood flow CT scan of acute ischemic stroke patients. In particular, long-term high doses of radiation sensitive organs and we Measured using phantom and a glass dosimeter. Apply the existing protocol suggested by the manufacturer (fixed time delay technique) and the proposed new convergence protocol (bolus tracking technique), reporting to measure the dose, dose reduction was to prepare the way. Results up to 39.8% as compared to the existing protocols in a new suggested convergence protocol, a minimum of 5.8% was long-term dose is reduced. Test dose of $CDTI_{vol}$ and DLP values decreased 25%, respectively, were measured at less than recommended dose. Try checking the protocol set out in the existing based on the analysis result of the above, by applying the proposed new convergence protocol by reducing the dose would have to contribute to improved public health. It is believed to be research continues to find the optimum protocol in the other tests.

Analysis of Factors Influencing the Integrated Bolus Peak Timing in Contrast-Enhanced Brain Computed Tomographic Angiography (Computed Tomographic Angiography (CTA)의 검사 시 조영제 집적 정점시간에 영향을 미치는 특성 인자를 분석)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Jung, Jae-Yong;Yun, Jung-Soo;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.59-69
    • /
    • 2016
  • The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast-enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was $716.53mGy{\cdot}cm$ and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination.

Comparison of bone subtraction CT angiography with standard CT angiography for evaluating circle of Willis in normal dogs

  • Soyon An;Gunha Hwang;Rakhoon Kim;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Science
    • /
    • v.24 no.5
    • /
    • pp.65.1-65.9
    • /
    • 2023
  • Background: Bone subtraction computed tomography angiography (BSCTA) is a useful alternative technique for improving visualization of vessels surrounded by skull bone. However, no studies have compared computed tomography angiography (CTA) and BSCTA for improving the visibility of canine cerebral blood vessels. Objectives: To evaluate the potential benefit of BSCTA for better delineation of brain arteries of the circle of Willis (CoW) in dogs by comparing BSCTA with non-subtraction computed tomography angiography (NSCTA). Methods: Brain CTA was performed for nine healthy beagle dogs using a bolus tracking method with saline flushing. A total dose of 600 mgI/kg of contrast agent with an iodine content of 370 mgI/mL was injected at a rate of 4 ml/s. Bone removal was achieved automatically by subtracting non-enhanced computed tomography (CT) data from contrast CT data. Five main intracranial arteries of the CoW were analyzed and graded on a scale of five for qualitative evaluation. Results: Scores of basilar artery, middle cerebral artery, and rostral cerebral artery in the BSCTA group were significantly higher than those in the NSCTA group (p = 0.001, p = 0.020, and p < 0.0001, respectively). Scores of rostral cerebellar artery (RcA) and caudal cerebral artery (CCA) did not differ significantly between the two groups. However, scores of RcA and CCA in the BSCTA group were higher than those in the NSCTA group. Conclusions: BSCTA improved visualization of intracranial arteries of the CoW with close contact to bone. Thus, it should be recommended as a routine scan method in dogs suspected of having brain vessel disease.

The Clinical Usefulness Evaluation of Normal Saline Injection in Coronary Artery Computed Tomography Angiography(Coronary CTA) (관상동맥 전산화단층촬영 조영검사에서 생리식염수 투여를 통한 임상 유용성 평가)

  • Jung, Kang-Kyo;Lee, Mi-Hwa;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.307-313
    • /
    • 2014
  • The purpose of this study is that in coronary artery angiography computed tomography (coronary CTA), to gain high quality of image and to use low dose radiation by administrating normal saline and converting the mode of scanning heart rate (HR) characteristics before infusing contrast media. All patients data (total specimens: 200, male: 108, female: 92) were measured by using appropriate mode of scanning the heart rate (HR) after injection of saline. in addition we measured radiation dose (CTDIvol, effective dose) in all examinations. CT number and noise, and blurring of coronary artery (proximal RCA, middle RCA, proximal LCA) were measured and compared. The result of this study after injection of saline, mean heart rate was decreased about $4.8{\pm}0.3bpm$ (beats per minute). 33 patients (13%) got converting scan mode due to reducing heart rate (HR). In prospective gating mode, radiation dose were measured less $6.0{\pm}1.0mSv$ (54.1%) than retrospective gating mode. Also showed a significant difference in heart rate decrease in image evaluation.

Safety and efficacy of target controlled infusion administration of propofol and remifentanil for moderate sedation in non-hospital dental practice

  • Douglas Lobb;Masoud MiriMoghaddam;Don Macalister;David Chrisp;Graham Shaw;Hollis Lai
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.1
    • /
    • pp.19-28
    • /
    • 2023
  • Background: Fearful and anxious patients who find dental treatment intolerable without sedative and analgesic support may benefit from moderate sedation. Target controlled infusion (TCI) pumps are superior to bolus injection in maintaining low plasma and effect-site concentration variability, resulting in stable, steady-state drug concentrations. We evaluated the safety and efficacy of moderate sedation with remifentanil and propofol using TCI pumps in non-hospital dental settings. Methods: A prospective chart review was conducted on 101 patients sedated with propofol and remifentanil using TCI pumps. The charts were completed at two oral surgeons and one general dentist's office over 6 months. Hypoxia, hypotension, bradycardia, and over-sedation were considered adverse events and were collected using Tracking and Reporting Outcomes of Procedural Sedation (TROOPS). Furthermore, patient recovery time, sedation length, drug dose, and patient satisfaction questionnaires were used to measure sedation effectiveness. Results: Of the 101 reviewed sedation charts, 54 were of men, and 47 were of women. The mean age of the patients was 40.5 ±18.7 years, and their mean BMI was 25.6 ± 4.4. The patients did not experience hypoxia, bradycardia, and hypotension during the 4694 min of sedation. The average minimum Mean Arterial Pressure (MAP) and heartbeats were 75.1 mmHg and 60.4 bpm, respectively. 98% of patients agreed that the sedation technique met their needs in reducing their anxiety, and 99% agreed that they were satisfied with the sedation 24 hours later. The average sedation time was 46.9 ± 55.6 min, and the average recovery time was 12.4 ± 4.4 min. Remifentanil and propofol had mean initial effect-site concentration doses of 0.96 µ/.ml and 1.0 ng/ml respectively. The overall total amount of drug administered was significantly higher in longer sedation procedures compared to shorter ones, while the infusion rate decreased as the procedural stimulus decreased. Conclusion: According to the results of this study, no patients experienced adverse events during sedation, and all patients were kept at a moderate sedation level for a wide range of sedation times and differing procedures. The results showed that TCI pumps are safe and effective for administering propofol and remifentanil for moderate sedation in dentistry.