• 제목/요약/키워드: Bolted Connection

검색결과 174건 처리시간 0.019초

유한요소해석을 통한 수평 및 수직볼트로 체결된 PHC 파일 연결부의 안전성 평가 (Safety Evaluation of Horizontal and Vertical Bolted Connection between PHC Piles Using Finite Element Analysis)

  • 김수은;김성보
    • 한국강구조학회 논문집
    • /
    • 제30권2호
    • /
    • pp.97-104
    • /
    • 2018
  • PHC 파일을 연결하기 위해 수평 및 수직 볼트를 사용한 연결부의 안전성 평가를 유한요소해석을 통하여 수행하였다. 수치해석 모델은 유한요소해석 프로그램인 ABAQUS를 이용하였으며 모든 연결 장치를 3D Solid 모델로 모델링하였다. 볼트 연결부는 ABAQUS에 제시된 Contact 및 Tie 조건에 고려하여 검토하였다. 유한요소해석을 통해 PHC 파일 연결부의 압축, 인장, 휨 및 전단 해석을 수행하였으며, 각 연결 장치에서 발생하는 Von-Mises 응력을 도출하여 볼트연결부의 안전성을 평가하였다.

An anti-noise real-time cross-correlation method for bolted joint monitoring using piezoceramic transducers

  • Ruan, Jiabiao;Zhang, Zhimin;Wang, Tao;Li, Yourong;Song, Gangbing
    • Smart Structures and Systems
    • /
    • 제16권2호
    • /
    • pp.281-294
    • /
    • 2015
  • Bolted joint connection is the most commonly used connection element in structures and devices. The loosening due to external dynamic loads cannot be observed and measured easily and may cause catastrophic loss especially in an extreme requirement and/or environment. In this paper, an innovative Real-time Cross-Correlation Method (RCCM) for monitoring of the bolted joint loosening was proposed. We apply time reversal process on stress wave propagation to obtain correlation signal. The correlation signal's peak amplitude represents the cross-correlation between the loosening state and the baseline working state; therefore, it can detect the state of loosening. Since the bolt states are uncorrelated with noise, the peak amplitude will not be affected by noise and disturbance while it increases SNR level and increases the measured signals' reliability. The correlation process is carried out online through physical wave propagation without any other post offline complicated analyses and calculations. We implemented the proposed RCCM on a single bolt/nut joint experimental device to quantitatively detect the loosening states successfully. After that we implemented the proposed method on a real large structure (reaction wall) with multiple bolted joint connections. Loosening indexes were built for both experiments to indicate the loosening states. Finally, we demonstrated the proposed method's great anti-noise and/or disturbance ability. In the instrumentation, we simply mounted Lead Zirconium Titanate (PZT) patches on the device/structure surface without any modifications of the bolted connection. The low-cost PZTs used as actuators and sensors for active sensing are easily extended to a sensing network for large scale bolted joint network monitoring.

유리섬유 조합에 따른 보강 집성재 볼트접합부의 전단강도 특성 (Shear Strength of Reinforced Glulam-bolt Connection by Glass Fiber Combination)

  • 김건호;송요진;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권1호
    • /
    • pp.51-57
    • /
    • 2013
  • 직물형 유리섬유 조합에 따른 보강 집성재의 볼트 접합부 전단 성능을 알아보기 위하여 인장형 전단시험을 실시하였다. 보강재는 직물형 유리섬유로서 유리섬유 배열 형태는 평직형과 능직형을 사용하였다. 보강 집성재는 5층으로 직물형 유리섬유의 삽입 위치와 조합 형태를 달리하여 층재 사이에 삽입 적층시켜 제작하였다. 인장형 전단 시험편은 강판 삽입형로서 끝면거리 7D에 직경 12, 16 mm의 볼트로 접합하였다. 체적비 1% 직물형 유리섬유 보강 집성재의 경우 12 mm 볼트 접합부의 항복 전단내력은 집성재 외층부보다 내층부를 보강한 시험편에서 10% 큰 값을 나타내었다. 체적비 2% 직물형 유리섬유 보강 집성재의 항복 전단내력은 12 mm 볼트 접합부의 경우 각층재 사이에 삽입 적층시킨 시험편이 보강하지 않은 접합부보다 약 22% 향상되었으며, 16 mm 볼트 접합부의 항복 전단내력은 약 20% 향상되었다.

Numerical cyclic behavior of T-RBS: A new steel moment connection

  • Ataollahi, Saeed;Banan, Mohammad-Reza;Banan, Mahmoud-Reza
    • Steel and Composite Structures
    • /
    • 제21권6호
    • /
    • pp.1251-1264
    • /
    • 2016
  • After observing relatively poor performance of bolted web-welded flange beam-to-column connections during 1994 Northridge earthquake, various types of connections based on two concepts of: (i) strengthening the connection; and (ii) weakening the beam ends were proposed. Among these modified or newly proposed connections, bolted T-stub connection follows the concept of strengthening. One of the connections with the idea of weakening the beam ends is reduced beam section (RBS). In this paper, finite element simulation is used to study the cyclic behavior of a new proposed connection developed by using a combination of both mentioned concepts. Investigated connections are exterior beam-to-column connections designed to comply with AISC provisions. The results show that moment capacity and dissipated energy of the new proposed connection is almost the same as those computed for a T-stub connection and higher than corresponding values for an RBS connection.

Wireless Impedance-Based SUM for Bolted Connections via Multiple PZT-Interfaces

  • Nguyen, Khac-Duy;Kim, Jeong-Tae
    • 비파괴검사학회지
    • /
    • 제31권3호
    • /
    • pp.246-259
    • /
    • 2011
  • This study presents a structural health monitoring (SHM) method for bolted connections by using multi-channel wireless impedance sensor nodes and multiple PZT-interfaces. To achieve the objective, the following approaches are implemented. Firstly, a PZT-interface is designed to monitor bolt loosening in bolted connection based on variation of electro-mechanical(EM) impedance signatures. Secondly, a wireless impedance sensor node is designed for autonomous, cost-efficient and multi-channel monitoring. For the sensor platform, Imote2 is selected on the basis of its high operating speed, low power requirement and large storage memory. Finally, the performance of the wireless sensor node and the PZT-interfaces is experimentally evaluated for a bolt-connection model Damage monitoring method using root mean square deviation(RMSD) index of EM impedance signatures is utilized to estimate the strength of the bolted joint.

강관말뚝 기초 두부 연결부의 압축거동에 관한 연구 (The Study on Compressive Behavior of Connection Member between Steel Pipe Pile and Concrete Footing)

  • 윤일로;홍기남
    • 한국산업융합학회 논문집
    • /
    • 제9권3호
    • /
    • pp.183-190
    • /
    • 2006
  • Generally, application of steel pile as deep foundation member needs specials requirement for the connection method between steel pipe and concrete footing. To investigate real compressive behavior of connection member between steel pipe pile and concrete footing, three specimens were tested with carefully designed experimental system. Main test variable is the connection method between steel pipe pile and concrete footing. The bolted bonding method and hook bonding method was considered as the connection method in this study. From the test results gained from experiment, it was conformed that two types of connection method have the almost same compressive resistance capacity. Therefore, we can conclude that these two connection methods can be used as the strengthening method to verify the compressive composite action of concrete and steel pipe pile.

  • PDF

분포하중을 받는 목재 적층복합재 빔의 볼트 체결 최적화 설계 (Design Optimization of Bolted Connection with Wood Laminated Composite Beams Subjected to Distributed Loads)

  • 조희근
    • 한국생산제조학회지
    • /
    • 제26권3호
    • /
    • pp.292-298
    • /
    • 2017
  • Numerical analysis for various design parameters should be preceded by optimal design of composite materials. Numerous studies have been conducted on the bolting of interconnecting beams. In this study, the response surface method was applied to optimize the design of bolted joints connected by laminated wood composite beams. The response surface was created by combining the FEA code for composite analysis and the algorithm for forming the response surface. Optimization on this response surface was performed with a genetic algorithm to derive the results. The determination of the optimum bolt-hole position for the connection of composite beams is an optimization problem. Tsai-Wu composite failure index, maximum deflection, and simple von Mises stress are set as the objective functions. It has been proved that the design results of the optimized bolt-hole are superior to the design performance of the existing conventional bolt-hole position.

Dowel-embedment Properties-Based Finite Solid Element Model for Bolted Connections

  • Hong, Jung-Pyo;Kim, Hyun-Bae;Oh, Jung-Kwon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권5호
    • /
    • pp.563-570
    • /
    • 2014
  • Two transversely isotropic plasticity-based models for wood, derived from the standard compression properties and the embedment properties were investigated for suitability of application for bolted connections. It was found that the conventional connection models involving the compression properties were incapable of simulating the real behaviour of the connections because the compression properties provided too stiff foundation to represent embedding behaviour of wood under the bolt. However, wood foundation-based connection model that was newly developed using the bolt embedment properties showed good agreement with the actual behaviour of bolted connections.

볼트로 겹침이음된 펄트루젼 복합재 접합부의 구조적 거동 (Structural Behavior of Bolted Lap-Joint Connection in the Pultruded FRP Structural Members)

  • 이영근;신광열;주형중;남정훈;윤순종
    • Composites Research
    • /
    • 제23권1호
    • /
    • pp.37-43
    • /
    • 2010
  • 이 연구에서는 볼트로 겹침이음된 펄트루젼 복합재의 접합부에 대한 구조적 거동을 실험적 연구를 통해 조사하였다. 펄트루젼 복합재 접합부의 구조적 거동 조사에 앞서 재료의 역학적 성질을 파악하기 위해 펄트루젼 복합재의 인장 및 전단실험을 수행하였고, 이를 바탕으로 볼트의 수와 배열을 변수로 3종류의 겹침이음 시편을 제작하였다. 겹침이음 접합부 실험은 접합부를 중심으로 인장하중이 작용하도록 하중을 재하하였고, 하중증가에 따른 접합부의 구조적 거동 및 파괴모드를 조사하였다. 실험결과 접합부에 대한 파괴는 대부분 전단파괴로 나타났으며, 실험을 통해 얻어진 데이터를 분석하여 설계를 위한 기초자료로 활용될 수 있도록 하였다.

An experimental study of the behaviour of double sided bolted billet connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • 제29권5호
    • /
    • pp.603-622
    • /
    • 2018
  • Precast concrete structures are erected from individual prefabricated components, which are assembled on-site using different types of connections. In the present design of these structures, beam-to-column connections are assumed pin jointed. Bolted billet beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is currently limited information concerning their detailed structural behaviour under vertical loadings. The experimental work has involved the determination of moment-relative rotation relationships for semi-rigid precast concrete connections in full-scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and bolt arrangements conformed to successful commercial practice. Proprietary hollow core floor slabs were tied to the beams by 2T25 tensile reinforcing bars, which also provide the in-plane continuity across the connections. The contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. The flexural strength of the connections in the double-sided tests was at least 0.93 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.94 to 1.94 times the flexural stiffness of the attached beam. In general, the double-sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided bolted billet connection test results are presented in this paper. The behaviour of single sided bolted billet connection test results is the subject of another paper.