철근 콘크리트 보의 보강을 위한 하이브리드 조립형 보강기법에 관한 해석적 연구 (Analytical Study on Hybrid Prefabricated Retrofit Method for Reinforced Concrete Beams)

  • 문상필;이성호;이영학;김민숙
    • 한국공간구조학회논문집
    • /
    • 제20권3호
    • /
    • pp.71-79
    • /
    • 2020
  • In this paper, the hybrid prefabricated retrofit method that improve structural performance and reduce construction period was developed by using a finite element analysis. The hybrid prefabricated retrofit method consist of a Z-shaped side plate, a L-shaped lower plate, and a bottom plate containing an steel plate with openings. This shape has advantage that a retrofit method is possible regardless of the size of the beams and a follow-up process such as reinforcement bars placing are not required. The finite element analysis of hybrid Prefabricated retrofit method showed the most ideal stress distribution when the thickness of bottom plate was 10mm, the thickness of the L-shaped lower plate was 5mm, the thickness of the Z-shaped side plate was 2.5mm, and the bolt spacing was 200mm. The bending strength equation of Hybrid prefabricated retrofit method was proposed through the plastic stress distribution method in KDS 41 31 00. The result of Comparison the proposed equation with the finite element analysis, it is determined that the design of hybrid prefabricated retrofit method is possible through the KDS 41 31 00.

유한요소법을 이용한 type 4 수소저장용기용 고정 장치의 구조적 안전성 분석에 관한 연구 (A Study on the Structural Safety Analysis of Neck Mount Block of Type 4 Hydrogen Storage Vessel by Finite Element Method)

  • 김건우;김혜원;박한민;이정호;윤수진;이한수;김종열;이석진;유계형;윤영길;김한상
    • 한국수소및신에너지학회논문집
    • /
    • 제35권2호
    • /
    • pp.195-204
    • /
    • 2024
  • The study involves a finite element analysis to evaluate the structural integrity of the neck mount block for a type 4 hydrogen storage vessel, with the aim of enhancing its strength and rigidity. The existing neck mount block consists of a fixed part and a sliding part, each comprising a body block for load support, a screw part for neck boss fixation, and bolts. To analyze the vulnerabilities of the neck mount block under bolt fastening and load conditions relative to vehicle travel directions, a structural analysis process was developed. Comparative analysis between the enhanced design and the existing model was performed, resulting in improved strength and rigidity. The objective is to provide guidance for the current product development and to offer fundamental data for the design and structural analysis of future development projects.

SCM435 강의 라운드-오발 및 스퀘어-다이아몬드 압연 공정에서의 AGS 분포 (AGS Distribution of Round-oval and Square-Diamond Rolling of SCM435 Steel)

  • 이호원;;;;임용택
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 제5회 압연심포지엄 신 시장 개척을 위한 압연기술
    • /
    • pp.317-326
    • /
    • 2004
  • This study investigated tile local austenite grain size (AGS) distribution In rolling of SCM435 steel which is commonly used for high strength bolt. To investigate AGS distribution, round-oval (R-O) and square-diamond (S-D) rolling experiments were carried out with pilot mill. In round-oval rolling, local AGS has a tendency to increase when it goes to outward. In square-diamond rolling, local AGS has a tendency to increase when it goes to free surface. To investigate relation between AGS and process parameter, three dimensional FE analysis was carried out along with rolling experiment. To validate accuracy of FE analysis, we compared deformed geometry with FE result. The AGS prediction combined AGS model with numerical analysis was also carried out for center node of S-D rolling. Although this study brought experimental observation and its qualitative analysis into focus and quantitative AGS prediction will be done as a further work.

  • PDF

Evaluating long-term relaxation of high strength bolts considering coating on slip faying surface

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제16권6호
    • /
    • pp.703-718
    • /
    • 2014
  • The initial clamping forces of high strength bolts subjected to different faying surface conditions drop within 500 hours regardless of loading, any other external force or loosening of the nut. This study develops a mathematical model for relaxation confined to creep on a coated faying surface after initial clamping. The quantitative model for estimating relaxation was derived from a regression analysis for the relation between the creep strain of the coated surface and the elapsed time for 744 hours. This study establishes an expected model for estimating the relaxation of bolted joints with diverse coated surfaces. The candidate bolts are dacro-coated tension control bolts, ASTM A490 bolt, and plain tension control bolts. The test parameters were coating thickness, species of coating. As for 96, 128, 168, and $226{\mu}m$ thick inorganic zinc, when the coating thickness was increased, relaxation after the initial clamping rose to a much higher range from 10% to 18% due to creep of the coating. The amount of relaxation up to 7 days exceeded 85% of the entire relaxation. From this result, the equation for creep strain can be derived from a statistical regression analysis. Based on the acquired creep behavior, it is expected that the clamping force reflecting relaxation after the elapse of constant time can be calculated from the initial clamping force. The manufacturer's recommendation of inorganic zinc on faying surface as $75{\mu}m$, appears to be reasonable.

Moment-rotation relationship of hollow-section beam-to-column steel joints with extended end-plates

  • Wang, Jia;Zhu, Haiming;Uy, Brian;Patel, Vipulkumar;Aslani, Farhad;Li, Dongxu
    • Steel and Composite Structures
    • /
    • 제29권6호
    • /
    • pp.717-734
    • /
    • 2018
  • This paper presents the flexural performance of steel beam-to-column joints composed of hollow structural section beams and columns. A finite element (FE) model was developed incorporating geometrical and material nonlinearities to evaluate the behaviour of joints subjected to bending moments. The numerical outcomes were validated with experimental results and compared with EN1993-1-8. The demountability of the structure was discussed based on the tested specimen. A parametric analysis was carried out to investigate the effects of steel yield strength, end-plate thickness, beam thickness, column wall thickness, bolt diameter, number of bolts and location. Consequently, an analytical model was derived based on the component method to predict the moment-rotation relationships for the sub-assemblies with extended end-plates. The accuracy of the proposed model was calibrated by the experimental and numerical results. It is found that the FE model is fairly reliable to predict the initial stiffness and moment capacity of the joints, while EN1993-1-8 overestimates the initial stiffness extensively. The beam-to-column joints are shown to be demountable and reusable with a moment up to 53% of the ultimate moment capacity. The end-plate thickness and column wall thickness have a significant influence on the joint behaviour, and the layout of double bolt-rows in tension is recommended for joints with extended end-plates. The derived analytical model is capable of predicting the moment-rotation relationship of the structure.

유한요소해석에 의한 ASME Code 적용 압력용기 스터드 암나사산의 건전성 평가 (Integrity Evaluation for Stud Female Threads on Pressure Vessel according to ASME Code using FEM)

  • 김문영;정남용
    • 대한기계학회논문집A
    • /
    • 제27권6호
    • /
    • pp.930-937
    • /
    • 2003
  • The extension of design life among power plants is increasingly becoming a world-wide trend. Kori #1 unit in Korea is operating two cycle. It has two man-ways for tube inspection in a steam generator which is one of the important components in a nuclear power plant. Especially, stud bolts fur man-way cover have damaged by disassembly and assembly several times and degradation for bolt materials for long term operation. It should be evaluated and compared by ASME Code criteria for integrity evaluation. Integrity evaluation criteria which has been made by the manufacturer is not applied on the stud bolts of nuclear pressure vessels directly because it is controlled by the yield stress of ASME Code. It can apply evaluation criteria through FEM analysis to damaged female threads and to evaluated safety fer helical-coil method which is used according to Code Case-N-496-1. From analysis results, we found .that it is the same results between stress intensity which got from FEM analysis on damaged female threads over 10% by manufacture integrity criteria and 2/3 yield strength criteria on ASME Code. It was also confirmed that the helical-coil repair method would be safe.

Seismic Behavior Investigation on Blind Bolted CFST Frames with Precast SCWPs

  • Wang, Jingfeng;Shen, Qihan;Li, Beibei
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1666-1683
    • /
    • 2018
  • To explore seismic behavior of blind bolted concrete-filled steel tube (CFST) frames infilled with precast sandwich composite wall panels (SCWPs), a series tests of blind bolted square CFST frames with precast SCWPs under lateral low-cyclic loading were conducted. The influence of the type of wall concrete, wall-to-frame connection and steel brace setting, etc. on the hysteretic curves and failure modes of the type of composite structure was investigated. The seismic behavior of the blind bolted CFST frames with precast SCWPs was evaluated in terms of lateral load-displacement relation curves, strength and stiffness degradation, crack patterns of SCWPs, energy dissipation capacity and ductility. Then, a finite element (FE) analysis modeling using ABAQUS software was developed in considering the nonlinear material properties and complex components interaction. Comparison indicated that the FE analytical results coincided well with the test results. Both the experimental and numerical results indicated that setting the external precast SCWPs could heighten the load carrying capacities and rigidities of the blind bolted CFST frames by using reasonable connectors between frame and SCWPs. These experimental studies and FE analysis would enable improvement in the practical design of the SCWPs in fabricated CFST structure buildings.

Analysis and design of demountable steel column-baseplate connections

  • Li, Dongxu;Uy, Brian;Aslani, Farhad;Patel, Vipul
    • Steel and Composite Structures
    • /
    • 제22권4호
    • /
    • pp.753-775
    • /
    • 2016
  • This paper aims to investigate the demountability of steel column-baseplate connections subjected to monotonic and cyclic loading. This paper presents the finite element analysis of steel column-baseplate connections under monotonic and cyclic loading. The finite element model takes into account the effects of material and geometric nonlinearities. Bauschinger and pinching effects were also included in the developed model, through which degradation of steel yield strength in cyclic loading can be well simulated. The results obtained from the finite element model are compared with the existing experimental results. It is demonstrated that the finite element model accurately predicts the initial stiffness, ultimate bending moment strength of steel column-baseplate connections. The finite element model is utilised to examine the effects of axial load, baseplate thickness, anchor bolt diameter and position on the behaviour of steel column-baseplate connections. The effects of various parameters on the demountability of steel column-baseplate connections are investigated. To achieve a demountable and reusable structure, various design parameters need to be considered. Initial stiffness and moment capacity of steel columnbaseplate connections are compared with design strengths from Eurocode 3. The comparison between finite element analysis and Eurocode 3 indicates that predictions of initial stiffness for semi-rigid connections should be developed and improved design of the connections needs to be used in engineering practice.

비보강 확장단부판 접합부의 에너지소산능력 평가 (Evaluation of the Energy Dissipation Capacity of an Unstiffened Extended End-plate Connection)

  • 이수권;양재근
    • 한국강구조학회 논문집
    • /
    • 제27권2호
    • /
    • pp.243-250
    • /
    • 2015
  • 확장단부판(extended end-plate) 접합부는 보-기둥 모멘트 접합부의 한 형태로 접합부를 구성하는 단부판(end-plate)의 두께 및 길이, 고장력볼트의 개수 및 직경, 고장력볼트의 게이지 거리, 용접부의 치수 및 길이 등에 따라서 상이한 거동특성과 에너지소산능력을 발현한다. 이러한 확장단부판(extended end-plate)는 미국 및 유럽 등지에서는 다양한 기하학적 형상으로 기둥-보 접합부에 적용되고 있다. 그러나 현재 우리나라에서는 강구조 보-기둥 접합부에 적극적으로 적용되고 있지 못한 상황이다. 이렇게 적용성이 높지 않은 이유로는 기하학적 형상변화에 따른 설계강도식 제안, 에너지소산능력 평가 및 시공지침의 제공이 적절하게 이루어지지 못하고 있기 때문이다. 따라서 이 연구에서는 단부판(end-plate) 두께가 상대적으로 얇은 기하학적 형상을 갖는 비보강 확장단부판(unstiffened extended end-plate) 접합부의 에너지소산능력을 평가하여 에너지소산능력 예측모델을 제안하기 위한 기초자료를 제공하기 위하여 진행하였다. 이를 위하여 비보강 확장단부판(unstiffened extended end-plate) 접합부에 대한 3차원 비선형 유한요소해석을 단부판(end-plate)의 두께를 변수로 하여 수행하였다.

도로 폭이 좁은 굴착공사에서 연결부가 적용되는 장지간 주형의 수치해석적 거동 평가 (Numerical Analysis on the Structure Behavior of the Connected Long-span Beam during Excavation in Narrow Streets)

  • 최광수;하상봉;이환우
    • 한국전산구조공학회논문집
    • /
    • 제33권4호
    • /
    • pp.263-270
    • /
    • 2020
  • 본 연구의 대상은 도로 폭이 좁은 시가지에서 굴착공사 시 적용되는 장지간 주형의 연결부이다. 일반적으로 적용되고 있는 연결부에서 상부 플랜지의 단차와 피로균열 등의 문제로 연결부의 신뢰도가 저하된다. 연결부의 결함을 보완하고 안전성을 향상시킨 개선형 연결부를 개발하였다. 유한요소 기반의 상용프로그램(ABAQUS)를 이용하여 개선형 연결부의 거동을 평가하였다. 먼저, 개선형 연결부에 적용되는 고장력 볼트 연결 및 강재와 콘크리트의 합성거동을 구현하기 위한 수치해석 방법을 제안하였다. 비교논문의 실험결과와 수치해석 결과의 비교를 통하여 개선형 연결부를 해석하는데 있어 수치해석 방법의 적합성을 검증하였다. 본 연구에서 제안하는 수치해석 방법을 적용하여 개선형 연결부와 일반형 연결부가 적용된 장지간 주형을 해석하였다. 장지간 주형의 탄소성 거동과 연결부의 응력분포를 수치 해석적으로 비교분석하였다. 개선형 연결부의 도입으로 25%의 압축응력이 감소되며 구조적 성능 개선효과 및 안전성을 확인하였다.