• Title/Summary/Keyword: Bolt equation

Search Result 46, Processing Time 0.018 seconds

A Study on the Concrete Breakout Capacity of CIP Anchor Bolts under Shear Loading (전단력을 받는 선설치 앵커볼트의 콘크리트 파열파괴강도 평가 연구)

  • Park, Yong-Myung;Jeon, Myeong-Hui;Choi, Myung-Kuk;Kim, Cheol-Hwan;Kim, In-Gi
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.2
    • /
    • pp.207-215
    • /
    • 2012
  • The 45-degree cone failure theory has been used in concrete anchor bolts design under shear loading, but the CCD (Concrete Capacity Design) method was adopted as a new design method since 2000. However, the method was allowed only for anchor diameters of less than 50mm because it is based on the experimental results of small size anchor bolts. Therefore, it is necessary to develop a rational concrete breakout capacity equation for medium-to-large size anchor bolts with large edge distance. In this study, shear tests on M56 cast-in-place single anchor bolt with edge distance of 350mm were performed using four test specimens. Based on the test results and findings of existing studies, a new equation for the breakout capacity of anchor bolts under shear loading with edge distance of up to 750mm was proposed.

TAFEM을 이용한 터널 예제 해석

  • Jo, Seon-Gyu;Jeong, Jae-Dong;Eom, Jong-Uk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1991.10a
    • /
    • pp.216-232
    • /
    • 1991
  • This Finite Element Program(TAFEM) has been developed to be able to carry out the structural analsis of tunnel section and simulate the surrounding ground behaviour due to New Austrian Tunnelling Method, of which main support is the surrounding ground, itself. The Elasto-plastic theory has been applied. The used finite elements are 8-noded isoparametric element(rock & shotcrete), 2 or 3-noded rod element(rock bolt) and infinite boundary element. The load incremental method and tangential stiffness method has been used. Associated flow rule was applied to plastic flow and yield criteria inclued not only Mohr-Coulomb but also Drucker-Prager. In this paper, Drucker-Prager yield criterion has been used. The relationship between plastic strain and stress is based on the incremental strain concept and stress-strain equation on the basis of the stress path of each gauss point has been adopted. It may be rational that rock is considered to be no-tension material, so that no-tension analysis has been adopted in accordance with the brittle fracture constitutive equation.

  • PDF

Removable shear connector for steel-concrete composite bridges

  • Suwaed, Ahmed S.H.;Karavasilis, Theodore L.
    • Steel and Composite Structures
    • /
    • v.29 no.1
    • /
    • pp.107-123
    • /
    • 2018
  • The conception and experimental assessment of a removable friction-based shear connector (FBSC) for precast steel-concrete composite bridges is presented. The FBSC uses pre-tensioned high-strength steel bolts that pass through countersunk holes drilled on the top flange of the steel beam. Pre-tensioning of the bolts provides the FBSC with significant frictional resistance that essentially prevents relative slip displacement of the concrete slab with respect to the steel beam under service loading. The countersunk holes are grouted to prevent sudden slip of the FBSC when friction resistance is exceeded. Moreover, the FBSC promotes accelerated bridge construction by fully exploiting prefabrication, does not raise issues relevant to precast construction tolerances, and allows rapid bridge disassembly to drastically reduce the time needed to replace any deteriorating structural component (e.g., the bridge deck). A series of 11 push-out tests highlight why the novel structural details of the FBSC result in superior shear load-slip displacement behavior compared to welded shear studs. The paper also quantifies the effects of bolt diameter and bolt preload and presents a design equation to predict the shear resistance of the FBSC.

The Static Strength Analysis of Prying Action for T-flange Shape Structure Using F10T High Strength Bolt (F10T 고장력 볼트를 이용한 T-형 플랜지형 구조물의 Prying Action에 따른 정적강도 해석)

  • Park, Myung-Kyun;Lee, Joong-Won;Koo, Bon-Sung
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.19-24
    • /
    • 2008
  • This paper presents and discusses the experimental results on the F10T high strength bolts used in the T-flange joint structure. The experimental works were carried out for the parameters which are flange web thickness, the distance between bolts, prying ratio. The results show that the working stress imposed to bolts decreases as the flange web thickness increases on the other hand the imposed stress to the bolts increases as the distance between two bolts increases. In other words the strength of the T-flange joint increased as the web flange thickness increases and the distance between two bolts decreases. The prying ratio is increased as the distance between two bolts increases and as the flange web thickness decreases However, the degree of stress decrease in flange thickness variation is not that high as the distance variation between two bolts. Finally the equation for predicting the failure stress in T-flange joint structure using F10T high strength bolts was suggested.

Bearing Strength of Glass Fiber Reinforced Glulam Bolted Connection

  • Kim, Keon-ho;Hong, Soon-il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.652-660
    • /
    • 2015
  • To study the bearing characteristics of glass fiber reinforced glulam for structural design, bearing strength tests were performed. Bearing loads were applied in the direction parallel to the grains, and the holes were prepared in such a way that the bolts would bear and support all the layers. The yield bearing strengths of the glass fiber reinforced glulam were found to be similar to those of the non-reinforced glulam, and were almost constant regardless of increases in bolt diameter. The ratio of the experimental yield bearing strength to the estimated bearing strength according to the suggested equation of the Korea Building Code and National Design Specification was 0.91~1.03. For the non-reinforced glulam and the sheet glass fiber reinforced plastic glulam, the maximum bearing load was measured according to the splitting fracture of specimens under bolt. The textile glass fiber reinforced glulam underwent only an embedding failure caused by the bearing load. The failure mode of reinforced glulam according to bearing load will influence the failure behavior of bolted connection, and estimating the shear yield strength of the bolted connection of the reinforced glulam is necessary, not only by using the bearing strength characteristics but also using the fracture toughness of the reinforced glulam.

The Application of a Simplified Pullout Test for High-Strength Concrete (고강도 콘크리트에 대한 간이 인발시험법 적용)

  • Ko, Hune-Bum;Jeon, Doo-Jin;Lee, Min-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.49-55
    • /
    • 2017
  • In the seventies, a number of researchers carried out experiments on pullout tests with prototype equipment, and the pullout test was certified as a reliable nondestructive testing(NDT) method for determining the strength of concrete. To estimate the strength of high-strength concrete, we propose a simplified pullout test that uses as a break-off bolt a standard 10mm bolt with a groove on the shaft, an insert nut, and a pullout instrument that includes a hydraulic oil pump without a load cell. To verify the advantages of the simplified pullout test(low cost, simplicity, and convenience), four wall specimens were tested with two levels of concrete strength, 30 MPa and 50 MPa, using a simplified pullout tester with a load cell. The pullout load and concrete compressive strength were measured every day until day 7, day 14, day 21 and day 28. It was found that the pullout load was very similar to the compressive strength. Therefore, we have verified that a simplified pullout test can be used to evaluate the in-place strength of high-strength concrete in structures. The prediction equation of the groove diameter of the break-off bolt(y) with the concrete strength(x) was derived as y=0.05x+3.79, with a coefficient of determination of 0.88 found through regression analysis.

Analytical Study on Hybrid Prefabricated Retrofit Method for Reinforced Concrete Beams (철근 콘크리트 보의 보강을 위한 하이브리드 조립형 보강기법에 관한 해석적 연구)

  • Moon, Sang-Pil;Lee, Sung-Ho;Lee, Young-Hak;Kim, Min-Sook
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.3
    • /
    • pp.71-79
    • /
    • 2020
  • In this paper, the hybrid prefabricated retrofit method that improve structural performance and reduce construction period was developed by using a finite element analysis. The hybrid prefabricated retrofit method consist of a Z-shaped side plate, a L-shaped lower plate, and a bottom plate containing an steel plate with openings. This shape has advantage that a retrofit method is possible regardless of the size of the beams and a follow-up process such as reinforcement bars placing are not required. The finite element analysis of hybrid Prefabricated retrofit method showed the most ideal stress distribution when the thickness of bottom plate was 10mm, the thickness of the L-shaped lower plate was 5mm, the thickness of the Z-shaped side plate was 2.5mm, and the bolt spacing was 200mm. The bending strength equation of Hybrid prefabricated retrofit method was proposed through the plastic stress distribution method in KDS 41 31 00. The result of Comparison the proposed equation with the finite element analysis, it is determined that the design of hybrid prefabricated retrofit method is possible through the KDS 41 31 00.

Structural Design Equation for a Box-shape Pressure Compensated Chamber of Pilot Mining Robot (파일럿 집광로봇 박스형 압력보상용기 구조설계식)

  • Lee, Minuk;Hong, Sup;Lim, Woochul;Lee, Tae Hee;Choi, Jong-Su
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.66-73
    • /
    • 2012
  • A pressure compensated chamber of a pilot mining robot isolates and protects an electrical-electronic system from the ambient highly pressured water. Since the inner pressure of the chamber is compensated with outer water pressure using hydraulic oil and pressure compensator, there exists a pressure difference, less than 1 bar, between outer and inner surface. The structural safety of the chamber is obtained relatively easier than the canister type which inner pressure is kept as the atmospheric pressure. However, due to the adoption of box shape for space efficiency and usage of the transparent engineering plastic viewport for checking inner circumstance, the viewport can be largely deformed. This large deformation can cause an additional tensile force, called the prying force, to the bolt-flange connection parts of the viewport. In this paper, we suggest the structural design equation considering the prying action for designing the structure of a box-shape pressure compensated chamber.

Development of the Method for Inspecting the Clamping Force of Torque Shear Bolts Using the Electricity energy of Electric torque wrench (전동렌치 전기에너지를 이용한 토크쉬어볼트의 체결축력 검사기법 개발)

  • Lee, Hyeon-Ju;Nah, Hwan-Seon;Kim, Kang-Sik;Kim, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.162-170
    • /
    • 2010
  • The torque-coefficient of torque-shear type high-strength bolts is affected by the environmental factors, such as 'wet', 'rust', 'exposure to air' and workability during tightening high strength bolts. It is difficult to assume the direct tension induced into the bolt due to variation of torque-coefficient for torque-shear type high-strength bolts. Therefore, it is essential to measure tension loads of bolts and to verify the clamping force under construction. In this study, the manufacture of trial product was planned to identify the induced force into the bolts. The algorithm for a trial product was composed of the relation between electricity energy taken from torque shear wrench and tension force from hydraulic tension meter. The regression analysis equation to measure the direct tension was derived by statistical analysis using Minitab program. It is considered that the trial product is reliable tool to evaluate the tension force comparable to a commercial torque wrench.

Mechanical Properties of High Stiffness Shear Connector (고강성 스터드볼트의 역학적 특성에 관한 연구)

  • Eom, Chul-Hwan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.491-496
    • /
    • 2015
  • The headed studs used extensively for steel-composite construction are specified as SS400 in the current Korean Standard specification considering the welding condition. And the corresponding equation for the shear force calculation is limited for the use of compression strength of concrete below $300kgf/cm^2$. However, it is expected that the high strengthening and precasting of both steel and concrete due to the necessity of shear connector or other connecting material for the combination of steel and concrete. Therefore, the experimental results obtained during the development process of high strength stud for the connection of high strength concrete and the steel member are reported in this paper. Also the effectiveness of newly developed shear connector using pipe(pipe stud) to increase the stiffness of a stud is verified by comparing both the stiffness and the strength with common stud bolt through the welding ability, mechanical characteristics and experimental investigation.