• 제목/요약/키워드: Boiling temperature

검색결과 698건 처리시간 0.033초

만액식 증발기의 열전달 촉진관에서 저온 비등열전달의 이력현상 특성 (Hysteresis on Boiling Heat Transfer at Low Temperature on Enhanced Tubes in a Flooded Evaporator)

  • 윤현필;박종익;정진희;강용태
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.254-260
    • /
    • 2003
  • The boiling characteristics for R134a are studied to clarify the hysteresis at low temperature on enhanced tubes of a flooded evaporator. Initial boiling conditions, refrigerant temperature, and inlet temperature of the chilled water are considered as the key parameters of the experiments. Unlike previous studies of the boiling heat transfer with uniform heat flux and uniform wall temperature, the wall temperature was varied along the tube. In, this study, it was found that the hysteresis of the temperature overshoot (705) at the onset of nucleate boiling initially at the inlet section of the tube. It is also concluded that the abnormal operation can be avoided during the low temperature boiling if the refrigeration system is started with LMTD larger than $3.4^{\circ}C$ at initial stage and larger than $1.0^{\circ}C$ at normal stage.

벽면충돌분무에 관한 수치해석 (A Study of Numerical Analysis on Wall Impinging Spray)

  • 염정국
    • 동력기계공학회지
    • /
    • 제17권2호
    • /
    • pp.21-28
    • /
    • 2013
  • Phenomenon of droplet impingement with high temperature wall needs to be investigated because atomization process of droplet and cooling process of the wall by the impingement are very important in industry, thus studies concerned with temperature of piston wall have been conducted in spray characteristics analysis of diesel engine. Hence, in this study, we defined $DT_{sat}(=T_w-T_{sat})$ superheat degree of the wall by difference between $T_w$ considering surface temperature of piston in the actual engine and $T_{sat}$ saturation temperature of the fuel and then investigated spray behavior of wall impinging with variance of the boiling process. In this study, in order to analyze wall impingement of droplet in accordance with difference of boiling condition, calculational conditions were set as $DT_{sat}=40K$(nucleate boiling), $DT_{sat}=140K$(transition boiling), and $DT_{sat}=240K$(film boiling). As a result, it can be found that fuel vapor increases and droplet mass decreases in the order of the nucleate boiling, transition boiling, and film boiling.

Experiments on Time Dependent Film Boiling on a Sphere

  • Ounpanich Bancha;Pomprapha Temsiri;Archakositt Urith;Nilsuwankosit Sunchai
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.403-406
    • /
    • 2002
  • A number of the experiments on the phenomenon in which the thermal energy was transferred from a hot sphere to the surrounding water through the film boiling process had been conducted. As the sphere only carried the thermal energy associated with its initially high temperature but did not contain any other thermal source, the film boiling was only driven by the decreasing temperature of the sphere and, thus, was time dependent. The results from the experiments showed that the temperature of the sphere was slowly decreased in the beginning. This corresponded to the period in which the sphere was penetrating the water surface. Later, when the sphere was fully submerged and the transition film boiling was observed over the whole surface, the temperature of the sphere was decreased relatively much faster. In the last stage, the temperature of the sphere was again slowly decreased. This was considered caused by the relatively low temperature of the sphere, which reduced and later ceased the film boiling process. In addition, the estimation of the departure rate of the steam bubbles from the film layer was also correlated for the experiments.

  • PDF

초음파 진동에 의한 대류 및 비등 열전달 촉진 원리에 관한 연구 (Mechanisms of Convective and Boiling Heat Transfer Enhancement via Ultrasonic Vibration)

  • 김이구;김호영;강승민;강병하;이진호
    • 대한기계학회논문집B
    • /
    • 제27권5호
    • /
    • pp.612-619
    • /
    • 2003
  • This work experimentally studies the fundamental mechanisms by which the ultrasonic vibration enhances convection and pool boiling heat transfer. A thin platinum wire is used as both a heat source and a temperature sensor. A high speed video imaging system is employed to observe the behavior of cavitation and thermal bubbles. It is found that when the liquid temperature is below its boiling point, cavitation takes place due to ultrasonic vibration while cavitation disappears when the liquid reaches the boiling point. Moreover, when the gas dissolved in liquid is removed by pre-degassing, the cavitation arises only locally. Depending on the liquid temperature, heat transfer rates in convection, subcooled boiling and saturated boiling regimes are examined. In convection heat transfer regime, fully agitated cavitation is the most efficient heat transfer enhancement mechanism. Subcooled boiling is most enhanced when tile local cavitation is induced after degassing. In saturated boiling regime, acoustic pressure is shown to be a dominant heat transfer enhancement mechanism.

강제대류계(强制對流系)에 있어서 막비등열전달(膜沸騰熱傳達)에 관한 연구(硏究) (A Study on Film Boiling Heat Transfer in a Forced Convective Flow System)

  • 김유택;권순석;정대인
    • 설비공학논문집
    • /
    • 제3권1호
    • /
    • pp.51-60
    • /
    • 1991
  • The aim of this study is to investigate the heat transfer characteristics in the transient cooling process of a high temperature wall. The slow transient cooling experiment was carried out with a copper block of high thermal capacity. The results of these experiments are as follows. 1. Temperature histories measured by the thermocouple, which is 0.99, 2.00, 2.99mm from the heat transfer surface showed monotonous during the cooling process. These variation are the curves of typical temperature histories in film-boiling, transition-boiling, and nucleate-boiling regions. 2. The temperature histories were measured by thermocouple installed in the copper block. The variations of the surface heat fluxes and surface temperature were computed from the numerical solution method TDMA from the measured temperature histories for radial position one dimensional heat transfer inverse problem. The boiling curves were found by the computed temperature histories. 3. The rewetting point which starts to change from film boiling to nucleate boiling is not connected with the mass velocity and it were found that the temperature of rewetting point indicated about $100^{\circ}C$. 4. The heat flux of rewetting point was about $10^5Kcal/m^2h$, at that time, the heat transfer coeficient indicated about $1000Kcal/m^2h^{\circ}C$ irrelevent to mass velocity. 5. The wall superheat decreases as the pressure increases. But I found that rewetting point appeared under higher condition in the wall temperature.

  • PDF

액체,액체계의 막비등열전달 특성 (Film Boiling Heat Transfer Characteristics in Liquid-Liquid System)

  • 김병주
    • 대한기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.87-94
    • /
    • 1992
  • 본 연구에서는 실험적 해석을 통하여 액체-액체계의 직접접촉 막비등열전달 특성을 최소막비등지점과 막비등열유속의 측면에서 해석하고자 한다. 이는 직접접촉 비등에 대한 효율적인 열전달의 온도영역이나 주어진 액체-액체 계의 조합에 대한 증 기폭발의 발생가능성의 예측에 활용될 수 있을 것이다.

수평관내 냉매의 과냉비등열전달에 관한 연구 (A Study on the Subcooled Boiling Heat Transfer in a Horizontal Tube)

  • 김종헌;김철환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권3호
    • /
    • pp.26-33
    • /
    • 1994
  • A new reliable method to prediet the axial vapor fraction distribution from the measured probability density of the liquid bulk temperature is suggested in this paper. And also the actual quality of the subcooled boiling flow is easily calculated from the liquid bulk temperature. When the heat generating rate is reached to the CHF value, the sharp wall temperature increasing by the wall temperature fluctuation is occurred under the CHF condition. This paper presents the simple wall temperature fluctuation model of transition boiling by the repeating process of overheating and quenching, when the coalescent bubble passes slowly near the wall. Experiments for the subcooled R-113 flow are carride-out in the range of(0.9399~4.461)${\times}10^6$kg/$m^2$hr mass velocity and 10~3$0^{\circ}C$ intel subcooling condition.

  • PDF

물-공기 혼합분무에 의한 고온 강판 냉각에 대한 연구 (I) -막비등 열전달에 대한 공기질량유속의 영향- (A Study on Cooling of Hot Steel Surface by Water-Air Mixed Spray(I) -The Effect of Air Mass Flux on Film Boiling Heat Transfer-)

  • 이필종;진성태;이승홍
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.247-255
    • /
    • 2004
  • The cooling characteristic of water-air mixed spray for high water mass flux is not well defined, compared to that of highly pressurized spray. A series of research program was planned to develop the boiling correlation for whole temperature range in case of water-air mixed spray with high water mass flux. The cooling experiments of hot steel surface with initial temperature of 820$^{\circ}C$ were conducted in unsteady state with relatively high water mass flux. A computer program was developed to calculate the heat flux inversely from measured data by three inserted thermocouples. Finally the effects of water and air mass flux on the averaged film boiling heat flux and wetting temperature were studied. In this 1st report, it is found that the boiling curve was similar to that of highly pressurized spray and the decreased slope of heat flux in film boiling region with respect to surface temperature became steep by increasing air mass flux. Also it is shown that, by increasing air mass flux, the averaged heat flux in film boiling region was increased, and then saturated and the wetting temperature was increased, and then decreased. Finally when the heat flux in film boiling region is compared with that of highly pressurized spray, it is known that the cooling is improved by introducing air up to 60%.

아임계 및 초임계에서 액체 질소 분류의 온도 분포 (Temperature Distribution of Liquid Nitrogen Jet at Sub- and Supercritical States)

  • 이현창;김해솔;조성호;성홍계;윤영빈
    • 한국추진공학회지
    • /
    • 제22권1호
    • /
    • pp.1-6
    • /
    • 2018
  • 아임계 및 초임계에서 액체질소 분류의 온도가 분사기 내부와 세 개의 축방향 하류 위치(0.9, 10.6, 28.1d)에서 열전대를 이용하여 측정되었다. 액체질소는 공급라인과 분사기를 냉각하며 분사되므로, 분류의 온도는 시간에 따라 감소한다. 이때 챔버와 분사기 사이에 분사 차압이 존재하므로, 아임계에서 분류는 감압비등에서 비등 그리고 비등이 일어나지 않는 상태로 변화한다. 초임계에서 가짜끓음이 존재함에 착안하여, 가짜 감압비등의 존재에 대해 가정하였으며, 실제로 초임계에서도 아임계와 유사하게 일정 온도 영역에서 하류에서 온도의 변화가 없는 구간이 확인되었으며, 이를 바탕으로 가짜 감압비등이 존재할 수 있음을 보였다.

환상유로에 있어서 수직고온관의 과도적 냉각과정에 관한 연구 (A study on the transient cooling process of a vertical-high temperature tube in an annular flow channel)

  • 정대인;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.156-164
    • /
    • 1986
  • In the case of boiling on high temperature wall, vapor film covers fully or parcially the surface. This phenomenon, film boiling or transition boiling, is very important in the surface heat treatment of metal, design of cryogenic heat exchanger and emergency cooling of nuclear reactor. Mainly supposed hydraulic-thermal accidents in nuclear reactor are LCCA (Loss of Coolant Accident) and PCM (Power-Cooling Mismatch). Recently, world-wide studies on reflooding of high temperature rod bundles after the occurrence of the above accidents focus attention on wall temperature history and required time in transient cooling process, wall superheat at rewet point, heat flux-wall superheat relationship beyond the transition boiling region, and two-phase flow state near the surface. It is considered that the further systematical study in this field will be in need in spite of the previous results in ref. (2), (3), (4). The paper is the study about the fast transient cooling process following the wall temperature excursion under the CHF (Critical Heat Flux) condition in a forced convective subcooled boiling system. The test section is a vertically arranged concentric annulus of 800 mm long and 10 mm hydraulic diameter. The inner tube, SUS 304 of 400 mm long, 8 mm I.D, and 7 mm O.D., is heated uniformly by the low voltage AC power. The wall temperature measurements were performed at the axial distance from the inlet of the heating tube, z=390 mm. 6 chromel- alumel thermocouples of 76 .mu.m were press fitted to the inner surface of the heating tube periphery. To investigate the heat transfer characteristics during the fast transient cooling process, the outer surface (fluid side) temperature and the surface heat flux are computed from the measured inner surface temperature history by means of a numerical method for inverse problems of transient heat conduction. Present cooling (boiling) curve is sufficiently compared with the previous results.

  • PDF