• 제목/요약/키워드: Boiler heat exchanger

검색결과 90건 처리시간 0.025초

왕겨 연소기(燃燒機)를 이용(利用)한 온수(温水)보일러 시스템 개발(開發)(II) -시뮬레이션 모형(模型) 개발(開發)- (Development of A Hot Water Boiler System with A Rice Hull Furnace -Development of A Mathematical Model of Simulation-)

  • 박승제;노상하;이용국
    • Journal of Biosystems Engineering
    • /
    • 제13권4호
    • /
    • pp.30-37
    • /
    • 1988
  • A mathematical model was developed and programmed for computer simulation of a prototype hot water boiler system with rice hull furnace to predict the temperature distributions in the rice hull furnace and water tank, mass flow rate of hot water and thermal efficiency of the system under various operation and design conditions. The effects of feed rate of rice hull, thickness of the furnace wall, the type of heat exchanger, diameter of the water circulation pipe, etc, on the performance of the system can be evaluated with this model. The validity and simulation results of this model will be published in the next paper.

  • PDF

Development of Induction Heated Hot Water System using Soft Switching PWM High Frequency Inverter

  • Lee, Jong-Kurl;Mun, Sang-Pil;Park, Man-Kyu;Nakaoka, Mustsuo
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.325-328
    • /
    • 2008
  • This paper presents a new conceptual electromagnetic induction eddy current-based stainless steel plate spiral type heater for heat exchanger or dual packs Heater in hot water system boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, an active clamped quasi resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle of zero voltage soft commutation with PWM is developed and demonstrated fora high efficient induction heated hot water system and boiler in the consumer power applications This consumer induction heater power appliance using active clamp soft switching PWM high-frequency inverter is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

SCR facility design for the selective catalyst performance of mixed gas

  • Woohyeon, Hwang;Kyung-Ok, Lee
    • 한국컴퓨터정보학회논문지
    • /
    • 제28권1호
    • /
    • pp.121-127
    • /
    • 2023
  • 본 연구에서는 질소화합물을 최적으로 줄일 수 있는 SCR에서 설계 조건과 CFD 해석 결과를 비교해 검토하고자 한다. 이를 위해 보일러의 쉘과 튜브 영역에 대해 설계 기준을 만족하고 있는지 CFD을 이용하여 해석하고 비교하였다. SCR 시스템에서 해석영역은 쉘 측은 가스·공기 열교환기 입구에서 출구까지이고, 튜브 측은 가스·공기 열교환기의 8개 튜브로 설정하였다. CFD 해석을 통해 SCR 시스템의 1차 촉매 면에서 가스의 속도 분포는 2.7%로 설계되었고, NH3/NOx 몰비 분포는 3.7%로 설계 기준을 만족하였다. 또한, 온도 분포의 균일성을 확인하였고 요구 조건인 260℃ 이상을 만족하였다. 촉매에 유입되는 가스의 각도는 2.9도로 설계 조건을 충족하였고, 그리고 발생하는 압력손실도 설계 요구조건을 만족하였다. 이러한 CFD 해석을 통해 각 영역별로 요구되는 설계조건을 만족하여 설계되어 최적으로 운전되고 있음을 확인하였다.

파울링 예측을 위한 가스-입자 이상 유동 해석(1)-고온 풍동 설계 및 성능실험- (Particulate Two-Phase Flow Analysis for Fouling Prediction(I)-Design of Hot Wind Tunnel and Its Performance Experiment-)

  • 하만영;이대래
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3695-3705
    • /
    • 1996
  • We designed the hot wind tunnel to reproduce the conditions of utility boiler and carried out its performance test, in order to investigate the particulate two-phase flow behaviour, the fouling and heat transfer characteristics to the heat exchanger. The hot wind tunnel introduces the control system to control the temperature in the test section. The particle is injected into the hot gas stream. The fouling probe (cylindrical tube) is positioned normal to the particulate gas-particle two-phase flow and cooled by the air. The temperature of gas and cooling air, and temperature in the fouling probe are measured as a function of time, giving the local and averaged heat transfer and fouling factor. The shape of particulate deposition adhered to the fouling probe is also observed.

상변화물질(PCM)을 이용한 가정용 보일러의 잠열축열식 예열모듈 개발 (Development of Preheating Module for Domestic Heating Facility, Using PCM(Phase Change Material) Thermal Storage Equipment)

  • 손철민;김태욱;나규동
    • 한국산업융합학회 논문집
    • /
    • 제12권3호
    • /
    • pp.163-169
    • /
    • 2009
  • A preheating module for domestic heating facility will increase a energy efficiency. That collects the wasted heat of exhaust gas and saves the energy. So a heating load is decreased because of a preheating that has a heating energy. Using of a preheating module, a boiler can reduce frequent operation of a burner. So it is increased persistence, decreased discharging noxious gases. Therefore we will intend to develop a heating facility that is a convenient system for the saving energy.

  • PDF

TRNSYS를 이용한 Borehole 방식 태양열 계간축열 시스템의 성능에 관한 연구 (A Study on Performance of Seasonal Borehole Thermal Energy Storage System Using TRNSYS)

  • 박상미;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.37-47
    • /
    • 2018
  • The heating performance of a solar thermal seasonal storage system applied to a glass greenhouse was analyzed numerically. For this study, the gardening 16th zucchini greenhouse of Jeollanam-do agricultural research & extension services was selected. And, the heating load of the glass greenhouse selected was 576 GJ. BTES (Borehole Thermal Energy Storage) was considered as a seasonal storage, which is relatively economical. The TRNSYS was used to predict and analyze the dynamic performance of the solar thermal system. Numerical simulation was performed by modeling the solar thermal seasonal storage system consisting of flat plate solar collector, BTES system, short-term storage tank, boiler, heat exchanger, pump, controller. As a result of the analysis, the energy of 928 GJ from the flat plate solar collector was stored into BTES system and 393 GJ of energy from BTES system was extracted during heating period, so that it was confirmed that the thermal efficiency of BTES system was 42% in 5th year. Also since the heat supplied from the auxiliary boiler was 87 GJ in 5th year, the total annual heating demand was confirmed to be mostly satisfied by the proposed system.

스탠딩컬럼웰형(SCW) 지중열교환기의 열성능 측정에 관한 실험적 연구 (An Experimental Study on the Thermal Performance Measurement of Standing Column Well type Borehole Heat Exchanger)

  • 이상훈;최용석;안근묵
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.122.2-122.2
    • /
    • 2010
  • Knowledge of ground thermal properties is most important for the proper design of BHE(borehole heat exchanger) systems. The configure type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for in-situ determination of design data for Standing Column Well apply. The main purpose has been to determine in-situ values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a sub-circulation pump, a boiler, temperature sensors, flow meter and a data logger for recording the temperature and circulation fluid flow data. A constant heating power is injected into the SCW through the test rig and the resulting temperature change in the SCW is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective in-situ values of rock thermal conductivity and thermal resistance of SCW.

  • PDF

이코너마이저 적용 열펌프 시스템의 부하변화에 따른 성능 특성 연구 (The Effect of Load Variation on the Performance of an Injection Heat Pump with an Economizer)

  • 최종민;박용정;강신형
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권3호
    • /
    • pp.1-7
    • /
    • 2014
  • Heat pumps have received a fair amount of attention all over the world for their high efficiency and low environmental impact. Employing heat pumps for residential heating and cooling produces only about 2038 kg-$CO_2$/year, an amount which is less than half that of conventional boiler systems. However, the use of single-stage heat pumps becomes uneconomical when they are operated at very low evaporating temperature or high condensing temperature. Two-stage heat pumps systems can be used successfully for low or high temperature applications. In this paper, the experimental study on the performance of two-stage heat pump with an economizer was executed in heating mode. When the secondary fluid inlet temperature to the indoor heat exchanger increased, the COP enhancement rate of two-stage heat pump with an economizer was increased. For all outdoor inlet temperature conditions, the performance of the heat pump with an economizer was higher than it without an economizer.

자트로파 유(Crude Jatropha Oil)에 대한 보일러 직접 연소 특성 (Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler)

  • 강새별;김종진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2934-2939
    • /
    • 2008
  • We conducted a test of a direct burning of crude Jatropha oil (CJO) in a commercial boiler system. The fuel, crude Jatropha oil is not biodiesel which comes from transeterification process of bio oil, but it is pure plant oil. The higher heating value (HHV) of the CJO is 39.3 MJ/kg (9,380 kcal/kg) and is higher than that of a commercial heating oil, 37.9 MJ/kg. The kinematic viscosity of CJO is 36.2 mm2/s at $40^{\circ}C$ and 8.0 mm2/s at $100^{\circ}C$. The burner used in the test is a commercial burner for a commercial heatingoil and its capacity is 140 kW (120,000 kcal/h). We did a preliminary test whether the combustion is stable or not. The preliminary test was a kind of open air combustion test using the commercial burner with crude Jatropha oil. We found that the combustion can be stable if the crude Jatrophaoil temperature is higher than $90^{\circ}C$. We measured the flue gas concentration by using a gas analyzer. The NOx concentration is $80{\sim}100\;ppm$ and CO concentration is nearly 0 ppm at flue gas O2 concentration of 3.0 and 4.5%.

  • PDF

설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012)

  • 한화택;이대영;김사량;김현정;최종민;박준석;김수민
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.