• Title/Summary/Keyword: Boiler System Control.

Search Result 209, Processing Time 0.024 seconds

Fluid Heating System using High-Frequency Inverter Based on Electromagnetic Indirect Induction Heating

  • Kim Yong-Ju;Shin Dae Cheul;Kim Kee Hwan;Uchihori Y.;Kawamura Y.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.69-74
    • /
    • 2001
  • In this Paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20kHz to 50kHz. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

A Wireless Sensor Network Based a Boiler Remote Control System (센서 네트웍 기반의 보일러 원격제어 시스템)

  • Jung, Kyu-Cheol;Lee, Chang-Bok;Park, Sang-Jun;Lee, Jong-Chan;Park, Ki-Hong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2009.01a
    • /
    • pp.259-262
    • /
    • 2009
  • 본 연구에서는 지그비 기반의 컴퓨팅 기술이 혼합된, 난방 보일러 제어시스템을 제안한다. 지그비 RF 기술과 임베디드 하드웨어 기술의 조합을 통하여, 주택 및 아파트 등에서 각 방별로 온도 및 습도를 취합하여 난방을 관리할 수 있다. 또한 제안된 시스템은 체감온도 기반으로 난방을 관리하여 인간에게 쾌적한 환경을 제공하기 위한 최적의 선택이라 할 수 있다.

  • PDF

Development of Automatic Control System for Midnight Electric Boiler (심야전기보일러의 통전제어시스템 개발)

  • Park, S.;Jung, B.;Yu, S.;Han, S.;Choi, B.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.956-958
    • /
    • 2001
  • 기저부하조성 및 부하율 향상을 위한 심야 전력요금제도의 정착으로 최근 심야전력축열기기의 보급이 활성화되고 있다. 그러나 모든 심야전력축열기기들이 심야요금개시시간대인 22:00경에 동시에 가동됨에 따라 23:00에 심야전력 부하가 최대에 이르러 전력피크가 발생하여 한전의 수요관리에 큰 어려움을 주고 있다. 따라서 이 피크 부하를 심야전력 공급시간대의 저부하시간대로 분산시킬 수 있는 심야전력기기 통전시간제어가 필요하게 되었으며, 이에 개발된 알고리즘을 실증시험을 통하여 검증하게 되었다.

  • PDF

Phenomenological model based failure detection of the boiler drum level control system of a power plant (현상적 모델에 기초한 보일러 플랜트 드럼 수위제어기의 고장감지)

  • Kim, J.K.;Chang, T.G.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.84-86
    • /
    • 2001
  • 본 연구에서는 플랜트의 계측신호로 부터 특징 패턴 파형들을 감지하고 패턴감지 정보로부터 플랜트의 운전상황 및 고장을 알아내도록 하는 새로운 기법을 제시하고, 이러한 기법의 실현에 필요한 신호처리 기초 연구를 수행하였다. 또한 보령화력 1.2호기 500MW급 드럼형 보일러및 제어 시스템을 대상으로 보일러 플랜트의 dynamics 모델링과 운전 시뮬레이션을 통하여 여러 운전 패턴및 고장 상황을 발생시켜 고장감지 앨고리즘들의 개발 및 시험과정에 적용하였다. 본 연구에서 수행한 보일러 및 보일러 제어계통에 대한 모델링 및 시뮬레이션은 실제 수행한 발전소 시험 데이터와 비교할 때 높은 일치도를 보이는 결과를 보였다.

  • PDF

Analysis of energy consumption of office building by thermal resistance-capacitance method (열저항-열용량법에 의한 사무실용 건물의 소비에너지 해석)

  • Lee, C.S.;Choi, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 1997
  • This paper reports the dynamic analysis of energy consumption for an office building by heat resistance-capacitance method. If a building is divided into several wall components and the wall components is replaced by one thermal capacitance and several thermal resistances, the building becomes an electric circuit. By solving the simultaneous equations of the circuit, the dynamic heat transfer characteristics and the energy consumption rate of the building were predicted. Accuracy of modified BIN method was evaluated by the present resistance-capacitance method. The result shows that modified BIN method overpredicts the heating load of the office building 15%. Annual energy consumptions of equipments(fan, boiler, chiller) for various ventilating control system(CAV, VAV, FCU+VAV, FCU+CAV) were compared. FCU+CAV shows the minimum annual energy consumption.

  • PDF

An Experimental study on characteristics of flame chemiluminescence using multi channel photo diode (다채널 포토다이오드를 이용한 화염 자발광 특성에 대한 실험적 연구)

  • Jang, Byunghwa;Kwon, Minjun;Kim, Daehae;Lee, Changyeop;Kim, Sewon
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.319-320
    • /
    • 2015
  • This study is aiming to establish the relationship between the optical signal of flame through an optical fiber and the equivalent ratio of flame. In this experiment, flame optical signal in a furnace is measured using photodiode. The combustion system is composed of 15W turbulent burner and industrial boiler, and flame chemiluminescence is measured at various experimental conditions. In this study, the flame chemiluminescence of turbulent premixed flame is measured using commercially available photodiode. It is experimentally investigated the relationship between equivalent ratio and photodiode signal.

  • PDF

Development of Electric Boiler Automatic Control System for Midnight Load Levelling (심야전력 부하평준화를 위한 심야전기보일러 통전제어시스템 개발)

  • Jung B.;Park S.;Yu S.;Han S.;Choi B.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.128-130
    • /
    • 2001
  • 심야전력요금제도의 정착으로 최근 심야전력축열기기의 보급이 활성화되고 있다. 그러나 모든 심야 전력축열기기들이 심야요금개시시간대인 22:00경에 동시에 가동됨에 따라 23:00에 심야전력 부하가 최대에 이르러 전력피크가 발생하여 한전의 수요관리에 큰 어려움을 주고 있다. 따라서 이 피크 부하를 심야전력 공급시간대의 저부하시간대로 분산시킬 수 있는 심야 전력축열기기 통전시간제어가 필요하게 되었다.

  • PDF

Application of a Domestic Boiler Distributed Control System to a Thermal Power Plant (국산개발 보일러 디지털 분산제어시스템의 화력발전소 실용화 최초적용)

  • Park, D.Y.;Byun, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2156-2159
    • /
    • 2001
  • 발전소 보일러 제어시스템 관련 기술은 분산처리 소프트웨어 기술, 네트워크기술, MMI(Man Machine Interface) 기술, 실시간 처리기술, 데이터베이스 기술, 하드웨어 개발기술 등을 총 망라하는 복합기술로써, 선진국들이 기술이전을 기피하는 고급기술이다. 현재 국내에서 사용하고 있는 발전소 보일러 제어시스템은 전부가 Bailey, ABB, Siemens, Westinghouse 사 등의 외국설비로써 보일러 본체와 일괄계약형태로 제어시스템 전체가 외국회사의 설계에 의해서 도입 설치되어 운용되고 있다. 이러한 상황에서 국산 제어시스템의 개발기술 확보와 기술자립 차원에서 오래된 아날로그 제어시스템을 디지털 분산제어시스템으로의 개체작업에 국산 개발 제어시스템을 중용량 석탄화력발전소에 최초로 실용화 적용하고 그 적용사례를 본 논문에서 소개한다.

  • PDF

A Characteristics of Hg, Pb, As and Se Emitted from Small and Medium Size Waste Incinerator Stacks (중.소형 폐기물 소각시설에서 배출되는 수은, 납, 비소, 셀렌 배출특성)

  • Lee, Han-Kook;Moon, Bu-Shik;Lee, Dong-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1205-1214
    • /
    • 2005
  • This study was carried out to investigate the emission characteristics of volatile metals(Hg, As, Se) and semi volatile metals such as Pb from small and medium size municipal solid waste incinerators(MSWIs). The concentrations of Hg, Pb, As and Se in emission gas from small size waste incinerators were higher than those of medium size waste incinerators. This is probably due to less air pollutant control devices and high emission gas temperature of the small size waste incinerators relative to the medium size waste incinerators. Emission gas temperature from small and medium size waste incinerators were divided into 2 groups. The first group was about $100^{\circ}C$ and the second roup in the range of $400{\sim}700^{\circ}C$. The concentrations of emission gas at the second group were Hg $70.43\;{\mu}g/Sm^3$, Pb $0.94\;{\mu}g/Sm^3$, As $9.83\;{\mu}g/Sm^3$ and Se $5.05\;{\mu}g/Sm^3$. The concentrations of Hg, Pb, As and Se at the first group were lower than those found at the second group. Besides, the removal efficiencies of Hg in medium size waste incinerators were $55.2{\sim}95.9%$. Emission gas temperature reduction from waste heat boiler(WHB) contribute to control of Hg. Based on above results, we postulate that the temperature of flue gas should play a very important role in volatile metal control in small and medium size MSWIs. In order to improve the volatile metals removal efficiency, the temperature of cooling system must be controlled and the air pollution control device should be operated properly.

Development and Application of Process Model for Description of Load Change of Boiler Plant in High Load (고부하에서의 보일러 플랜트 부하변동 묘사를 위한 프로세스 모델 개발 및 적용)

  • Park, Jeong;Lee, Ki-Hyun;Yang, Li-Ming;In, Jong-Soo;Park, Seok-Ho;Kweon, Sang-Hyeok;Oh, Dong-Han
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.41-51
    • /
    • 1997
  • A dynamic mathematical model of a thermal power plant with a single drum-type boiler is described with the base on modular concept. The present process model, which is including full scope of the components and high load changes, is based on physical approach through lumped parameters. The module, which means a component of the power plant and must essentially depict the characteristics of the component well, might be interconnected using pressure nodal method in a arrangement determined by users. With the results of the load changes of 75 MW to 95 MW and 95MW to 75 MW with the rate of 3 MW/min, the applicability of the process model is examined connecting to DCS(Dispersion Control System), which has a real running logic of 100 MW real power plant.

  • PDF