• 제목/요약/키워드: Boiler System Control.

검색결과 209건 처리시간 0.026초

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

퍼지 논리를 이용한 드럼형 보일러의 자동정지에 관한 연구 (A study on automatic shutdown of drum-type boiler using fuzzy logic)

  • 이한오;이재혁;황동한;변증남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.880-886
    • /
    • 1992
  • There has been continuous effort to achieve total automation of the power plants. But due to complexity, nonlinearities and time-varying properties of the system, no success has been reported if conventional and/or modern control theories are applied. In spite of this, the start-up and shutdown operations are successfully performed by skilled human operators who are able to utilize a great wealth of knowledge and past experiences. In this paper, in order to automate the shutdown operation of power plants, it is proposed that the operation be performed by a more efficient method than the current used, through dividing the total process into several subprocesses, introducing checkpoints, and using fuzzy logic. For this, fuzzy logic controllers and fuzzy decision-makers are designed and the validity is shown by simulation via a set of piecewise continuous shutdown models.

  • PDF

파울링 예측을 위한 가스-입자 이상 유동 해석(1)-고온 풍동 설계 및 성능실험- (Particulate Two-Phase Flow Analysis for Fouling Prediction(I)-Design of Hot Wind Tunnel and Its Performance Experiment-)

  • 하만영;이대래
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3695-3705
    • /
    • 1996
  • We designed the hot wind tunnel to reproduce the conditions of utility boiler and carried out its performance test, in order to investigate the particulate two-phase flow behaviour, the fouling and heat transfer characteristics to the heat exchanger. The hot wind tunnel introduces the control system to control the temperature in the test section. The particle is injected into the hot gas stream. The fouling probe (cylindrical tube) is positioned normal to the particulate gas-particle two-phase flow and cooled by the air. The temperature of gas and cooling air, and temperature in the fouling probe are measured as a function of time, giving the local and averaged heat transfer and fouling factor. The shape of particulate deposition adhered to the fouling probe is also observed.

상대 이득 행렬을 이용한 뉴로-퍼지 제어기의 설계 (Design of Neuro-Fuzzy Controller using Relative Gain Matrix)

  • 서삼준;김동원;박귀태
    • 한국지능시스템학회논문지
    • /
    • 제15권1호
    • /
    • pp.24-29
    • /
    • 2005
  • 일반적으로 다변수 계통에 대한 퍼지 제어에서 퍼지 규칙을 얻기가 어려워 입출력 사이의 페어링을 이용한 독립적인 단일 입력 단일 출력의 병렬 구조를 이용한다. 그러나, 결합되지 않은 입출력 변수간의 상호작용으로 제어 성능에 나쁜 영향을 준다. 특히, 강한 결합 특성을 가진 계통의 경우 제어 성능을 아주 저하시킨다. 본 논문에서는 이러한 상호작용에 의한 영향을 보상해주기 위해 상대 이득 행렬을 이용한 신경 회로망을 도입하였다 제안한 뉴로 퍼지 제어기는 역전파 알고리즘으로 학습되며 강호작용에 대한 결합강도를 자동으로 조정하여준다. 제안한 뉴로 퍼지 제어기의 성능을 200MW급 보일러 계통에 대한 컴퓨터 모의실험을 통해 입증하였다.

온돌 실내공간의 온도제어 (Temperature Control of Ondol Indoor-Space)

  • 신찬배;이재원;사종엽;이상천;조성환;서항석
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.538-545
    • /
    • 1995
  • The heat transfer model of ondol heating system is derived in the linear form. The step responses of On-Off controller, PID controller and Position type fuzzy controllers are compared in the sense of several aspects : variation of temperature feedback variable, variation of supplied heat quantity by the boiler, variation of flow rate, variation of thickness of the base, variation of the outdoor temperature.

  • PDF

ESS를 이용한 발전소 터빈제어밸브 전개 운전 제어로직 제안 (Suggestion of Logic to Control Power Plant Equipped ESS in case of Full Open Turbine Control Valve)

  • 정인영;이재헌
    • 플랜트 저널
    • /
    • 제18권4호
    • /
    • pp.66-72
    • /
    • 2023
  • 신재생에너지 비중 증가에 따른 전력계통 불안정성과 탈원전, 노후 석탄화력 폐쇄로 인한 안정적인 발전자원 감소에 대한 대응 방안으로 터빈제어밸브 4개중 2~3개를 교축하여 발전기 출력 증·감발과 주파수를 추종하는 복합 변압 운전 방식을 터빈제어밸브를 전개하여 교축손실을 줄임으로서 발전 효율을 극대화하는 순 변압운전 방식으로 대체하고, 계통 주파수 변동에 신속하게 대응하기 위해 ESS를 연계하여 주파수 추종 및 자동발전운전을 하는 제어로직을 500MW 석탄화력인 태안 5호기를 대상으로 개발하였다. ESS 운전(신속한 응답, 용량 한계)과 발전소 터빈제어밸브 교축 운전(느린 응답, 지속적인 운전)의 장·단점을 보완하는 협조제어 알고리즘이 실제 발전소에 적용시 발전 효율 향상은 물론 전력 수요에 신속하고 유연하여 대응하여 계통 안정성에 기여할 것으로 확신한다.

  • PDF

화력발전소 보일러 급수용 펌프 배관계의 이상소음 저감에 관한 연구 (Study on Noise Control for Piping System of BFP in a Power Plant)

  • 양경현;조철환;배춘희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.490-494
    • /
    • 2004
  • The purpose of this paper was to identify the mechanism that caused abnormal vibration and noise on the piping system connected to discharge flow of BFP(Boiler Feed water Pump) in a coal fired power plant, and to develop the device that can reduce the level of abnormal vibration and noise. Major results of this project can be summarized as follows: First, we analyzed the acoustic mode for the discharge piping of BFP to trace a path of the noise, and assumed that noise and vibration on the piping system can be related with length of pipe. Second, a minimized model of the piping system was set up to simulate abnormal vibration and noise within the specific range of operating frequencies, and as a result we confirmed that the acoustic mode affected the piping system considerably. Finally the test device which can reduce the level of abnormal noise and vibration was built to verify validity applying for the piping system. Then we concluded that the noise and vibration generated from the piping system was attributed to the acoustic resonance in piping system, and so developed new device which can reduce the level of noise and vibration under 40%. Put Abstract here.

  • PDF

LNG 운반선에서의 신개념 증발 가스 처리 시스템 - VaCo 시스템 (Third Wave of Gas Management System in LNG Carrier - VaCo System)

  • 최정호;유홍성;유경남;허안;이두영;류승각
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2007년도 특별논문집
    • /
    • pp.89-93
    • /
    • 2007
  • The Boil-off gas (BOG) generation during the voyage is inevitable since Natural Gas (NG) in normally liquefied below -160 degree C in atmosphere condition and small heat ingress due to relatively hot outside keeps evaporating continuously. The one of major issue in LNG carriers is to handle generated BOG from cargo tank. The generated BOG affects to increase the cargo tank pressure and Gas Management System (GMS) for LNG carriers is closely related to cargo tank pressure maintenance. Economically, BOG is generally used as fuel in LNG carrier. Newly developed GMS for LNG carrier in boiler propulsion system, VaCo System, not only accomplish automatic control in GMS but also ensure safer operation.

  • PDF

태양열을 이용한 흡수식 냉방기의 동특성 시뮬레이션 (Dynamic simulation of a solar absorption cooling system)

  • 정시영;조광운
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.784-794
    • /
    • 1998
  • The present study has been directed at developing thermal models to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collectors, a hot water storage tank, a fan coil unit, and the air-conditioned space. The operation of the system was simulated for 8 hours in two different operation modes. In the mode 1, the system operated without any capacity control.0 the mode 2, an auxiliary boiler supplied heat to the generator if hot water temperature became lower than a certain value. Moreover, the mass flow rate of hot water to the generator was controlled by comparing the instantaneous room air temperature with the design value. The variation of temperature and concentration in the system components and that of heat transfer rates in the system were obtained for both modes of operation. It was found that the room temperature was maintained near the desired value in the mode 2 by supplying auxiliary heat or controlling the mass flow rate of hot water, while the deviation of room temperature was quite great in the mode 2.

  • PDF

주거용건물의 바닥복사 난방방식에 대한 실태조사 연구 (Research on the actual condition of 'Under Floor Radiant Heating for Apartment Housing')

  • 우병관;이성;김삼열
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.81-86
    • /
    • 2007
  • The research analyzes the arrangement of boiler and hot water header, the method of radiator pipe setting, hot water supply control, hourly heating situation of each room for underfloor radiant heating systems in Korea and suggests an alternative to improve to efficient heating method. One of the best options for install position of hot water distributor is under kitchen sink which is center point of all rooms, according to previous research of the energy saving strategies. When the radiator pipes are arranged to each individual room instead of bedrooms through livingroom and kitchen, it has energy saving effects. For rooms without occupancy according to a time period, hot water supply method should be intermittent heating rather than continuous heating. For this intermittent heating method, individual control of hot water supply is more practical, and it can lead to massive energy savings. The intermittent heating system has time-lag, so it is more effective in energy saving with mild and comfort condition if the spaces are preheated by automatic control equipment prior to required time.