• 제목/요약/키워드: Body-surface temperature

검색결과 405건 처리시간 0.026초

액상환원침전법에 의한 저온활성화소결용 복합W분말의 제조방법 및 소결특성에 관한 연구 (A Study on the Manufacture of Composite W Powder for Low Sintering Temperature by Liquid Reduction Precipitation Method)

  • 김창욱;이철;정인;윤성렬
    • 한국표면공학회지
    • /
    • 제28권4호
    • /
    • pp.207-218
    • /
    • 1995
  • Tungsten(W) metal has excellent properties in heat-resistance, corrison-resistance and impact-resistance but W-Metal is hard to sinter because higher than $2,000^{\circ}C$ is required to sinter W-powder. Con-sequently, a deposit technique of Nikel Phosphorus(NiP) on W-powber by the liquid reduction precipitation method was performed. Sintering temperature of the resulting W-NiP composite was lowered around to $1,000^{\circ}C$, and the mechanical properties of the sintered body was studied. The most suitable conditions for NiP thin film deposit on W-Powder by the liquid reduction precipitation method, which are composition, concentration, pH and temperature of the liquid reduction solution, were considered. The activated sintering was carried out in a reducing condition furnace. Components and properties of the sintered body were investigated by the density and the hardness measurements, X- ray diffraction analysis, and microscopic photographs of the surface. Quantity of NiP thin film on W-powder could be varied by the change of the liquid reduction solution composition. The sintering temperature of W-NiP composite powder is lowered to $950^{\circ}C$ from $2,000^{\circ}C$ and the hardness is increased (ca. 720 Hv). Large shrinkage could be observed since density was increased from 5.5 to 11.0 g/$cm^2$ which 86.2% of theoretical density. W metal and $Ni_3P$ crystal were detected through X-ray diffraction on the sintered body. Perfectly activated sintering was observed by microscopic photographs.

  • PDF

절삭 공구용 다이아몬드 복합체의 저온 저압 소결 합성 및 후속 도전형 박막 공정 특성 연구 (A Study on the Sintering of Diamond Composite at Low Temperature Under Low Pressure and its Subsequent Conductive PVD Process for a Cutting Tool)

  • 조민영;반갑수
    • 한국산업융합학회 논문집
    • /
    • 제23권1호
    • /
    • pp.25-32
    • /
    • 2020
  • Generally, high-temperature, high-pressure, high-priced sintering equipment is used for diamond sintering, and conductivity is a problem for improving the surface modification of the sintered body. In this study, to improve the efficiency of diamond sintering, we identified a new process and material that can be sintered at low temperature, and attempted to develop a composite thin film that can be discharged by doping boron gas to improve the surface modification of the sintered body. Sintered bodies were sintered by mixing Si and two diamonds in different particle sizes based on CIP molding and HIP molding. In CVD deposition, CVD was performed using WC-Co cemented carbide using CH4 and H2 gas, and the specimen was made conductive using boron gas. According to the experimental results of the sintered body, as the Si content is increased, the Vickers hardness decreases drastically, and the values of tensile strength, Young's modulus and fracture toughness greatly increase. Conductive CVD deposited diamond was boron deposited and discharged. As the amount of boron added increased, the strength of diamond peaks decreased and crystallinity improved. In addition, considering the release processability, tool life and adhesion of the deposition surface according to the amount of boron added, the appropriate amount of boron can be confirmed. Therefore, by solving the method of low temperature sintering and conductivity problem, the possibility of solving the existing sintering and deposition problem is presented.

건식이중바닥온돌시스템 개발을 위한 실험적 연구 (A Experimental Study for Developing of the Dry Double Floors Hydronic Ondol System)

  • 김난행;손장열
    • 한국주거학회논문집
    • /
    • 제17권3호
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research was to evaluate the characteristics of thermal environment and thermal comfort in the Dry Double floors Hydronic Ondol System. Physical indoor thermal environments (the floor surface temperature, the vertical temperature, etc.) and skin temperature have especially been measured. Physical features conditions, sensation, thermal comfort, humidity sensation, comfort of body were investigated for the survey. As a result, (1) During the operation of the boiler (12 hour), the average indoor temperature is appeared to be $21.6^{\circ}C$. The floor surface temperature showed peak value of $31.4{\sim}40.6^{\circ}C$ after 8hours 30minutes after the start-point of the heating. The vertical difference of temperature was turned out to be not uniform. (2) While the skin temperature showed a narrow distribution of temperature in the Dry Double floors Hydronic Ondol system. (3) The response to thermal comfort which people felt was satisfactory, and most of them felt dry during the test.

초음파검사에서 인체모의 매질팬텀을 이용한 온도 변화와 TI MI 분석 (An Analysis of Temperature Change and TI MI using Tissue Mimicking Phantom in Ultrasonic Examination)

  • 전철민;한재복;곽종길;송종남
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.751-759
    • /
    • 2022
  • 현재 진단 초음파 및 건강검진 목적의 초음파 검사는 널리 이용되고 있고 건강보험 적용으로 더욱 증가 추세를 보이고 있다. 하지만 초음파검사의 위해성은 현재까지 명확히 밝혀진 바가 없어 초음파 검사 시 인체 조직의 온도가 상승하는 열효과를 알아보고자 본 연구에서는 인체 모의 매질 팬텀을 이용해 주파수, 모드별에 따른 표면과 심부 온도 변화를 시간별로 측정하였고 TI, MI 값도 비교하였다. 인체와 유사한 음향 특성 있는 카파 카라기난 분말과 고형화를 위해 염화칼륨을 소량 첨가하여 모의 팬텀 제작하였고 표면 온도계와 탐침용 온도계를 사용하여 표면과 심부 온도 변화를 측정하였다. 그 결과 저주파수를 사용하는 Convex Probe가 고주파를 사용하는 Linear Probe보다 높은 온도 상승을 보여 유의미한 차이를 보였고 표면에서 온도 상승이 가장 높았으며 1 cm의 낮은 깊이는 일시적 온도상승은 나타내지만 유의미한 온도변화는 없었다. 5 cm ~ 15 cm의 심부온도 변화는 없었으며 검사 시간동안 TI, MI값은 변화가 없었다. 이는 15분 실험동안 표면온도만 상승하였고 심부에는 온도변화가 없었기 때문에 인체에 유해할 만큼의 온도 변화를 나타내지 않을 것으로 사료되며 통상적인 진단초음파의 15분의 검사시간은 임상에서의 사용에는 무리가 없을 것으로 생각되지만 특정 부위의 장시간 검사는 온도 상승을 일으킬 수 있으므로 지양해야 될 것으로 사료된다.

Summer season temperature-humidity index threshold for infrared thermography in Hanwoo (Bos taurus coreanae) heifers

  • Kim, Na Yeon;Moon, Sang Ho;Kim, Seong Jin;Kim, Eun Kyung;Oh, Mirae;Tang, Yujiao;Jang, Se Young
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권10호
    • /
    • pp.1691-1698
    • /
    • 2020
  • Objective: The study sought to estimate the relationship between body surface temperature (BST) and temperature humidity index (THI) and to present the validity of THI as a heat stress index in the field. Methods: Eight Hanwoo heifers (20 to 32 month) were examined in a field trial, with a space allowance of 10 ㎡ per head. The BST was measured using an infrared thermographic camera. The BST of five body regions (eyes, hindquarters, nose, part of horns, and ears), ambient temperature (AT), and relative humidity (RH) were measured 7 times daily (07, 09, 11, 13, 15, 17, and 19 h) during each season with three replicates. Results: The THI ranged 34.0 to 56.9 during spring (AT, -1.0℃ to 13.4℃), 75.1 to 84.7 during summer (AT, 24.9℃ to 33.6℃), 55.8 to 70.9 during autumn (AT, 13.0℃ to 26.0℃) and 17.5 to 39.2 during winter (AT, -10.4℃ to 1.0℃). In the regression analysis, the coefficient of determination (R2) between THI and BST was 0.88, 0.72, 0.83, 0.86, and 0.85 for the eyes, hindquarters, nose, part of horn, and ears area, respectively. This indicates that BST has a strong correlation with AT and RH. Expression equations were estimated as Y (THI) = 31.54+0.1085X (BST of eyes) and Y (THI) = 30.48+0.1147X (BST of hindquarters) by simple linear regression analysis in this experiment. Conclusion: Consequently, the upper bound for heat stress estimation can be specified ranging from THI of 65 (eyes) to 70 (hindquarters). From this we can expect a precise feeding system for Korean native cattle in the field.

Effects of grain-based pecking blocks on productivity and welfare indicators in commercial broiler chickens

  • Byung-Yeon Kwon;Hyun-Gwan Lee;Yong-Sung Jeon;Ju-Yong Song;Jina Park;Sang-Ho Kim;Dong-Wook Kim;Kyung-Woo Lee
    • Animal Bioscience
    • /
    • 제37권3호
    • /
    • pp.536-546
    • /
    • 2024
  • Objective: This experiment was conducted to investigate the effect of grain-based pecking blocks on productivity and welfare status at two commercial broiler welfare-certified farms. Methods: Production and welfare indicators were assessed at two farms (designated Farm A and B). Both farms had two windowless houses with forced tunnel-type ventilation and housed broilers at stocking densities of approximately 16.7 birds/m2 (Farm A) and 16.8 birds/m2 (Farm B). Each house was divided into two or three equal sections and was provided with or without pecking blocks. Grain-based pecking blocks, measuring 25 × 25 × 25 cm, were given to broilers in both farms at 1 block per 1,000 birds. Various parameters including productivity (body weight and flock uniformity), corticosterone levels (in fecal droppings and feathers), footpad dermatitis, hock burn, feather dirtiness, gait score, litter quality, body surface temperature, and volatile fatty acids in fecal samples were assessed at 26 days of age, whereas litter quality was analyzed at 13 and 26 days of age. Results: There were no significant effects of providing pecking blocks on productivity (body weight and uniformity), fecal and feather corticosterone, welfare indicators (i.e., footpad dermatitis, hock burn, feather cleanliness, and gait score), and litter quality (i.e., moisture, nitrogen, and pH). No differences in body surface temperature between the control and enrichment treatments were noted in Farm B, but body surface temperatures of the head (p = 0.029) and legs (p = 0.011) in the enrichment vs. control group were elevated in Farm A. Butyrate concentration in the enrichment vs control group was higher in Farm B (p = 0.023), but this effect was not detected in Farm A. Conclusion: It is concluded that grain-based pecking blocks did not affect performance and welfare indicators. Further studies are warranted to elucidate the potential impact of grain-based pecking blocks on gut health indicators.

Updated Pretreatment Technologies for Automotive in Japan

  • Takaknwa, Hideki;Ishii, Hitoshi
    • Corrosion Science and Technology
    • /
    • 제6권5호
    • /
    • pp.245-250
    • /
    • 2007
  • Recently, to avoid global warming, reduction of $CO_2$ generation has been demanded. Each car manufacture takes positive actions for improvement in fuel consumption by various kinds of countermeasures, e.g. improving engine efficiency, using alternative fuels, lightening the car body. Regarding lightening of the car body, aluminum alloys and high tensile strength steels has been gradually adopted as lightweight materials. However, such materials are normally not easy to be treated with zinc phosphate system. Focusing the pre-treatment processes, low temperature phosphate system could be demanded for energy saving. This time, new surface conditioning process for lightweight materials and low temperature phosphate system shall be discussed.

보행보조 재활 로봇 착용에 따른 쾌적성 평가 (Comfort Evaluation by Wearing a Gait-Assistive Rehabilitation Robot)

  • 엄란이;이예진
    • 한국의류학회지
    • /
    • 제44권6호
    • /
    • pp.1107-1119
    • /
    • 2020
  • This study analyzed a subject's body reaction and subjective sensation when wearing a gait-assistive rehabilitation robot. The research method measured skin and clothing surface temperatures for 'seating-standing' and 'walking in place' exercises after wearing a gait-assistive rehabilitation robot. In addition, subjective sensation and satisfaction were evaluated on a 7-point Likert scale. The study results showed that the average skin temperature during exercise while wearing the gait-assistive rehabilitation robot was within a comfortable range. However, during the 'seating-standing' exercise, the skin temperature was slightly lowered. Additionally, the clothing surface temperature tended to be lower than the pre-exercise temperature after all exercises. The subjective sensation evaluation results showed that the wear comfort of the waist part was low during mobility/activity. In addition, an overall improvement in the wear comfort of the robot is necessary. The short-time movement of wearing and walking in the gait-assistive rehabilitation robot did not interfere with the thermal comfort of the body. However, the robot needs to be ergonomically improved in consideration of the long wearing time along with improved material that to satisfy overall wearing comfort.

임펠러 5-축 CNC 가공에 관한 연구 (A Study on The 5-Axis CNC Machining of Impeller)

  • 조현덕
    • 한국생산제조학회지
    • /
    • 제6권4호
    • /
    • pp.19-26
    • /
    • 1997
  • The manufacture of an impeller typically requires the 5-axis CNC machining, since the impeller is usually under working conditions such as high speed, high temperature, and high pressure. Thus, this study contributes to development of an exclusive CAM system for effective 5-axis CNC machining of a ruled surface type impeller. In this study, the sampled impeller is made of blades and a body and the blade consists of ruled surfaces between hub curve and shroud curve. In the post processing for 5-axis NC part program, the cutter axis direction vector is the straighten vector on ruled surface. The position of ball center in ball end mill cutter is decided on the interference check between the cutter and body surface of impeller using with the modified z-map method that z-axis is the same of cutter axis direction vector. The exclusive CAM system for an impeller developed in this study was very effective for designs and 50-axis machining of a ruled surface type impeller.

  • PDF

1994년 인천 연안역의 열수지 (Heat Budget in Incheon Coastal Area in 1994)

  • 최용규;윤홍주
    • 한국환경과학회지
    • /
    • 제8권3호
    • /
    • pp.293-297
    • /
    • 1999
  • Based on the monthly weather report of Korea Meteorological Administration (KMA) and daily sea surface temperature (SST) in Incheon harbor of National Fisheries Research and Development Institute, heat budget in Incheon coastal area was estimated. The temperature differences between the sea surface and near bottom were nearly within 1$^{\circ}C$. This indicate the mixing from the sea surface and the bottom. The net heat flux through the sea surface and the advection through the inner and outer bay was affected uniformly to the water body in Incheon coastal area. The net heat flux was about 110W/$m^2$ in maximum value on May, about -80W/$m^2$ in minimum on January. The net heat flux through the sea surface from the solar radiation was about 2.35$\times$${10}^5$W during the year. This heat flux flew out the bay through the advection by the same flux.

  • PDF