• 제목/요약/키워드: Body temperature measurement

검색결과 223건 처리시간 0.023초

고막체온과 액와체온의 비교 연구 - 성인대상자를 중심으로 - (Comparison of Tympanic and Axillary Temperatures)

  • 유재희;조현숙
    • 기본간호학회지
    • /
    • 제16권2호
    • /
    • pp.162-170
    • /
    • 2009
  • Purpose: To verify the usability of tympanic temperature measurement for adults, a comparison of tympanic and axillary temperatures was done. Method: The study was conducted during October 2008, and participants were 110 female nursing students. Axillary temperatures were taken with glass mercury thermometers for 5, 7 and 10 minutes. Tympanic temperatures were taken with Infrared Thermometer IRT 4520 on both ears, twice at a 5-second interval. The data were analyzed using the SPSS 12.0 program. Results: In the 1st measurement, the mean for right tympanic temperatures ($0.06^{\circ}C$) and for left ($0.03^{\circ}C$) were significantly higher than the 2nd. A comparison of mean temperatures for right and left, showed that the mean for the left side on the 1st measurement was significantly higher ($0.01^{\circ}C$) than the right. Also the temperature on left side in the 2nd measurement was higher ($0.04^{\circ}C$) than the right 2nd, but not significantly higher. The mean temperature for right and left tympanic on 1 st and 2nd measurements were significantly higher than axilla for 5 minutes ($0.58^{\circ}C$), for 7 minutes ($0.52^{\circ}C$), and for 10 minutes ($0.43^{\circ}C$). The tympanic temperature was the most closely correlated with the axillary temperature at 10 minutes. Conclusion: Findings indicate that measurement of tympanic temperature is a useful alternative to axillary temperature taken for 10 minutes.

  • PDF

소의 일중 체온변화 Data Base 구축에 관한 연구 (Establishment of Data Base for Body Temperature Change in Cattle)

  • 정왕용;이원현;이상철;이상락
    • 한국축산시설환경학회지
    • /
    • 제18권2호
    • /
    • pp.95-98
    • /
    • 2012
  • 센서 네트워크 및 무선 주파수 식별 기술을 이용하여 가축의 건강상태를 자동으로 모니터링 하기위한 기술에 활용하기 위하여 정상시 소의 체온 data base를 구축하였다. 체온측정을 위해 거세한 홀스타인 수소 3두를 공시하였다. 동물들은 stanchion barn에서 2주간 적응시킨 후 열전대와 recorder 장치를 이용하여 귀, 목, 머리와 심부 4부위의 온도를 9일간 연속 측정하였다. 측정한 체온의 모든 부위는 하루 중 낮 시간에는 체온이 올라가고 다시 저녁시간에는 체온이 떨어지는 패턴을 보였다. 하루중 심부체온은 $36.1^{\circ}C$에서 $38.2^{\circ}C$의 범위에서 변화하였다. 각 피부 온도는 환경온도 변화에 따라 차이를 보였다. 귀, 목, 머리 온도의 하루중 변화는 각각 $28.5{\sim}36.3^{\circ}C$, $28.0{\sim}36.1^{\circ}C$, $28.2{\sim}35.0^{\circ}C$를 나타내었다.

실험을 통한 이동형 냉방기의 실내 온도분포 특성의 검토 (Study on Indoor Thermal Environment Controlled by Portable Cooler)

  • 최동균;송두삼;김중호
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.49-54
    • /
    • 2016
  • The purpose of this study is to analyze the indoor temperature distribution of a room controlled by a personal and portable cooler. As an energy saving strategy, the personal air-conditioning or task conditioning system was developed and installed in office buildings in the 90 s. Many research results regarding the personal air-conditioning (PAC) system were focused on thermal comfort, localized ventilation efficiency and energy savings. However, the conventional PACs were only developed for application in office buildings. In this study, as a type of PAC, a portable cooler was analyzed in terms of indoor temperature distribution changes with the passage of time. The measurement was performed in a bedroom in an apartment house. The results showed that indoor temperature was controlled at about $24^{\circ}C$ around the human body. However, the ambient zone up to 1.5 m away from the the human body stayed at about $27.5^{\circ}C$.

초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도 (In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound)

  • 이수영;조상현;이충휘;김종만
    • 한국전문물리치료학회지
    • /
    • 제10권1호
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

귀 체온계 측온부의 이중 사출 공정 최적화에 관한 연구 (A study on optimization of the double injection process for temperature measuring part of an ear thermometer)

  • 백승익;정욱철;김인관;신광일;김태완
    • Design & Manufacturing
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2022
  • The importance of fast and accurate body temperature measurement with a portable thermometer is increasing. In order to reduce the temperature measurement response time of the infrared ear thermometer, it is very important to develop a structure for a thermometer having an efficient heat transfer path. Most of the existing ear thermometers are single structures that do not consider thermal efficiency, which may delay measurement time and reduce measurement accuracy. Therefore, in this study, the upper part of the thermometer in contact with the ear is made of a thermally conductive material, and the lower part of the thermometer is made of a thermal barrier material so that heat can be concentrated on the infrared sensor of the thermometer by blocking the upper part of the heat. For the efficiency of production, it was intended to be manufactured through the double injection process, and for this purpose, in this paper, the optimal process parameters were derived through the double injection process analysis.

Two-color LIF 기법을 이용한 단열체가 있는 밀페계 내에서의 자연대류에 관한 실험적 연구 (Experimental Study on the Natural Convection in an Enclosure with an Adiabatic Body Using the Two-Color LIF Method)

  • 권수현;정은호;민영욱;김경천
    • 한국가시화정보학회지
    • /
    • 제3권1호
    • /
    • pp.90-96
    • /
    • 2005
  • Most of the previous studies on natural convection were based on the numerical analysis, and some experimental studies considered the classic case of thermal convection. In this study, an adiabatic square body was located at the center of an enclosure between the bottom hot and top cold walls. And the measurement of the detailed temperature fields was conducted by the method of two-color Laser Induced Fluorescence using a Nd:Yag laser. As a result, heat transfer characteristics of natural convection with an adiabatic body was estimated as a function of time over a range of Rayleigh numbers.

  • PDF

Two-color LIF 기법을 이용한 단열체가 있는 밀폐계 내에서의 자연대류에 관한 실험적 연구 (Experimental study on the natural convection in an enclosure with an adiabatic body using the two-color LIF method)

  • 권수현;정은호;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.104-107
    • /
    • 2004
  • Most of the previous studies on natural convection were based on the numerical analysis, and some experimental studies considered the classic case of thermal convection. In this study, an adiabatic square body was located at the center of an enclosure between the bottom hot and top cold walls. And the measurement of the detailed temperature fields was conducted by the method of two-color Laser Induced Fluorescence using a Nd:Yag laser. As a result, heat transfer characteristics of natural convection with an adiabatic body was estimated as a function of time over a range of Rayleigh numbers.

  • PDF

주위 온도의 급격한 변화에 따른 압력 및 차압 전송기의 특성 변화 (The Characteristic Change of Pressure and Differential Transmitter due to a Rapid Change of Ambient Temperature)

  • 정종태;하영철;이철구;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.321-326
    • /
    • 2004
  • The pressure and differential pressure(DP) transmitters are used for gas flow rate calculation on the orifice gas metering system. On site, the pressure and DP transmitters are installed in a shelter to diminish the affects of environmental change such as an ambient temperature. But there has been an argument about the effectiveness of the shelter and this brought up the necessity to verify the affects of ambient temperature. These experiments were performed to verify the ambient temperature effects as observing the output of transmitters when the ambient temperature were changed from $-30^{\circ}C$ to $50^{\circ}C$. The results showed that the most of transmitters were operated in the spec range of performance criteria presented by manufacturer but the rapid change of ambient temperature could cause the larger measurement error for the DP transmitter of low span than others. Therefore the pressure and DP transmitters need to be operated and controlled within the proper range of ambient temperature.

  • PDF

외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정 (Investigation of Standard Error Range of Non-Contact Thermometer by Environment)

  • 김정은;박상웅;최혜경
    • 대한통합의학회지
    • /
    • 제8권4호
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

800MHz대의 전자파에 노출된 두부의 온도 측정 (Temperature Measurement for the Human Head under Local Exposure of Electromagnetic Wave with 800MHz)

  • 박주태
    • 전자공학회논문지T
    • /
    • 제36T권2호
    • /
    • pp.70-76
    • /
    • 1999
  • 최근에 휴대전화기가 저 연령층까지 널리 보급되어 어린이들의 두부내에 열점(hot-spot)형성문제가 염려되고 있는 실정이다. 전자파의 인체영향이 체온상승의 열적작용에 의한 것이라고 생각한다면 휴대전화기에 의해 발생하는 두부내 국소SAR의 인체영향도 두부의 온도상승과 연관된다고 추정된다. 본 논문은 휴대전화기를 실사용 상황에서 시간대별 두부의 국소부위에 대한 온도변화를 측정하였다. 그 결과 휴대전화기의 통화시작점에서 계속적인 온도상승을 보이다가 통화가 끝나는 시점에서 두부의 국소적인 온도변화는 빠르게 회복되지만 생체전신의 평균온도는 상승함을 알 수 있었다.

  • PDF