Purpose: influence of benzodiazepine (midazolam)or cholinergic inhibitor (atropine or glycopyrrlate) on intra-operative body temperature remains unclear and controversial. This study compares intra-operative body temperature in 50 abdominal surgical patients under general anesthesia between the administration of midazolam and glycopyrrolate in combination, or glycopyrrolate alone. Methods: Patients who underwent abdominal surgery were recruited from September 2008 through October 2009 at Gachon University Gil hospital in incheon. Core body temperature was measured in the right ear using a tympanic membrane thermometer at induction of general anesthesia and at 1 hr, 2 hr, and 3 hr after induction. Results: There were no differences in core body temperature at any measurement point between either patient group (F=1.08, $p$=.377). Core body temperature decreased throughout the 3 hr after induction in both groups (F=9.22, $p$ <.001). Specially, core temperatures at induction of general anesthesia (p<.001), 1 hr (p<.001), 2 hr ($p$ <.001), and 3 hr ($p$ <.001) after induction were lower than before administration of midazolam and glycopyrrolate, or glycopyrrolate alone. Conclusion: We conclude that a cholinergic inhibitor (glycopyrrolate, 0.1 mg) therefore seems not to affect intra-operative body temperature of patients given a benzodiazepine (midazolam, 0.04 mg $kg^{-1}$), and not to increase body temperature in patients not given a benzodiazepine during the 3 hr after the induction of general anesthesia. Intra-operative warming therefore is needed to prevent hypothermia in surgical patients who receive pre-operative administration of midazolam and/or glycopyrrolate.
In the experiment with a basic material for the design of summer wear that comfort can be obtained in temperature, to get individual differences, clothing styles (slacks, skirt), material differences(T/C, cotton), and the contrast between when naked and dressed, when two healthy females were dressed four kinds of summer wear as an object of experiment under the regular warm temperature environmental condition (24, 28, 32, $36^{\circ}C$, $60\pm10\%$ RH), the measurement of physiological, phychological change was taken and the result goes as follow; 1. Mean skin temperature rose by clothing, body weight loss decreased below $32^{\circ}C$, thermal sensation changed toward low temperature by $2\~3^{\circ}C$. 2. Mean skin temperature, body weight loss, the lowest blood pressure above $32^{\circ}C$, under-clothing temperature, and thermal sensation increased when in slacks to be compared with when in skirt. 3. Ambient temperature had a great effect on mean skin temperature, body weight loss, respiration, clothing surface temperature, under-clothing temperature and humidity, thermal sensation, etc. 4. It was admitted that pulse, thermal sensation, comfort show different individuality. 5. It was recognized that the lowest blood pressure, clothing surface temperature, under. clothing humidity differ according to the kinds of clothing. 6. A comfortable ambient temperature in clothing summer wear was about $27\~28^{\circ}C$.
Non-invasive blood glucose measurement from mouse tail was performed by near-infrared (NIR) spectroscopy. Three groups; normal, type I diabetes (insulin dependent diabetes mellitus, IDDM), type II diabetes (non-insulin dependent diabetes mellitus, NIDDM) group, were studied over a 10 weeks period with the collection of near-infrared (NIR) spectra. Spectral variations from long-term measurement (10 weeks) from dramatic and nonlinear changes in the optical properties of the live tissue sample were compensated by chemometrics techniques such as principle component analysis (PCA) and partial least squares (PLS) regression. The effect from mouse body temperature changes on NIR spectral data was also considered. This study showed that the compensation of variations from long-term measurement and temperature changes improved calibration accuracy of non-invasive blood glucose measurement.
Purpose : This study investigated the effects of active warming using a Warm Touch warming system or a cotton blanket in postoperative patients after general anesthesia for abdominal surgery. Methods : This quasi-experimental study utilized two experimental groups and one control group: a cotton-blanket group (n = 25) were warmed with a cotton blanket and a sheet; a forced-air warming group (n = 24) were warmed with a Warm Touch warming system, a cotton blanket, and a sheet; and a control group (n = 25) were warmed with a sheet. Measurement variables were postoperative pain, body temperature, and thermal discomfort. Data were analyzed using a one-way ANOVA, ${\chi}^2-tests$, Fisher's exact test, and a repeated measures ANOVA. Results : The effects of active warming using a Warm Touch warming system and a cotton blanket on postoperative patients was significant in reducing pain (F = 13.91, p < .001) and increasing body temperature (F = 12.49, p < .001). Conclusion : Active warming made a significant difference in pain and body temperature changes. Active warming methods may help patients' postoperative recovery and prevent complications. Further research is needed to explore the effects and side effects of active warming on recovering normothermia.
Recently, domestic animal disease caused tremendous damage to farmhouses and the damage stretched in nationwide with the spread of epidemic disease. To prevent animal diseases from happening again, the system development to easily measure the temperature of sick animals and identify of them is needed, thereby quickly treat them, reducing losses of farmhouses. However, a lack of related equipment and human resource hampered its effort to minimize its losses. This study tries to develop diagnosis system as part of measures to curb these domestic animal diseases. This paper present the 센서 node based on IEEE 802.15.4 which can be attached to the animal body for real-time temperature measurement. We design and implement tiny chip-type that can be attached to the body of animals. Then, we use available power only when measuring temperatures in a long term-basis. In this paper, the 센서 node was applied to horse's neck. We measure the horse's body temperature between $32.2^{\circ}C{\sim}33.7^{\circ}C$ and analyze phenomenon data for 4 months.
Using industrial robots and sensors, we developed an inline car body inspection system which proposes high flexibility and sufficient accuracy. Car Body Inspection(CBI) cell consists of two industrial robots, two corresponding carriages, camera vision system, a process computer with multi-tasking ability and several LDS's. As industrial robots guarantee sufficient repeatabilities, the CBI cell adopts the concept of relative measurement instead of that of absolute measurement. By comparing the actual measured data with reference data, the dimensional errors of the corresponding points can be calculated. The length of the robot arms changes according to ambient temperature and it affects the measuring accuracy. To compensate this error, a robot arm calibration process was realized. By measuring a reference jig, the differential changes of the robot arms due to temperature fluctuation can be calculated and compensated.
The aim of this study was to investigate the effect of complex Korean medicine treatment especially Buja-tang and Aconitum ciliare decaisne pharmacopuncture on patients with type 1 complex regional pain syndrome caused after a traffic accident. The patients was treated with Buja-tang, Aconitum ciliare decaisne pharmacupuncture, acupuncture and physical therapy during 20 days of hospitalization. Numerical rating scale (NRS), short form McGill pain questionnaire (SF-MPQ), body temperature measurement of the foot, manual muscle test (MMT) were used for assessment. After treatments, NRS of burning pain in the left ankle decreased from 8 to 4-5 and NRS of burning pain in the right ankle decreased from 7 to 4-5. Also, SF-MPQ results, foot temperature measurement and MMT showed improvement during hospitalization. This study shows that complex Korean medicine treatment especially Buja-tang and Aconitum ciliare decaisne pharmacopuncture are effective in alleviating symptoms in patients with type 1 complex regional pain syndrome.
저자들은 다양한 진료 환경과 연구 수행에 폭 넓게 이용할 수 있는 새로운 온도측정 시스템을 개발하기 위하여 임상에서 필요한 기능과 연구에 요구되는 기능을 가진 간편하고 편리한 온도측정 시스템을 개발하였다. 이 측정 시스템은 일정한 지점의 온도를 정확하고 신속하게 측정하여 기록할 수 있는 장치로서 실용 가능성을 다양하게 검증해 본 결과 기존의 평면적인 열 분포도보다 진보된 등온곡선을 도출할 수 있었으며, 기존의 체온 측정장치보다 더욱 편리하게 진료의 각 분야에 효과적으로 이용할 수 있음을 확인하였다. 본 연구결과에 의한 기대효과 및 향후 활용방안으로는 1) 환자의 체온 변화를 신속하게 진단할 수 있어서 치료효과의 극대화와 부작용의 최소화에 기여할 수 있다. 2) 체온의 변화를 일으키는 다양한 질환의 진단 및 치료성과 판정에 이용할 수 있다. 3) phantom을 이용한 다양한 실험적 연구를 수행할 수 있다. 4) 장기 입원중인 환자들을 대상으로 중앙통제 방식으로 환자들의 상태를 지속적으로 감시할 수 있어서 간호인력의 노동력 절약에 많은 도움을 줄 수 있다. 5) 현재의 기능을 더욱 발전시키면 다양한 질환의 환자들에게 두루 적용할 수 있으며, 환자 감시체제를 위한 필수장비로 이용할 수도 있다.
Backgroud and Objectives: Because the pain is subjective in human, we frequently need the objective tool for estimation of pain. The Visual Analog Scale (VAS) is a method for pain grading, but it is also a subjective method. The purpose of this study is to seek an objective method for measurement of pain. Author suggests that the estimation of local body temperature may be associated with the severity of pain in tonsillar disease and the change of it measured by Digital Infrared Thermographic Imaging (DITI), may also be correlated with the change of pain. Materials and Method : Four groups were selected and measured for VAS and body temperature in DITI. Group A and B were post-tonsillectomy groups divided by age. Group C was acute tonsillitis group. Group D was peritonsillar abscess group. Results : In Group A and B, the subjective VAS was significantly correlated with objective local body temperature (correlation coefficient r=0.673, 0.647) and significant correlation was also present in acute tonsillitis and peritonsillar abscess groups(r=0.596,0.642). Conclusion : The change of pain was strongly associated with that of local body temperature in tonsillar disease. DITI is a useful method for objective grading of pain and can be used for the study of postoperatve pain and effectiveness of pain control.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.