• Title/Summary/Keyword: Body temperature measurement

Search Result 223, Processing Time 0.03 seconds

Representation of Game Character Using Measurement Information of Player's Physical Status (게임 플레이어의 신체 측정 정보를 이용한 게임 캐릭터의 표현)

  • Park, So-Hee;Kim, Bo-Sung;Park, Jong-Seung
    • Journal of Korea Game Society
    • /
    • v.15 no.6
    • /
    • pp.7-16
    • /
    • 2015
  • To improve the sense of unity between game players and game world avatars, we propose a method to measure game player's physical status and manipulate game character appearances and behavior using the measurements. To measure the status, we implemented a hardware module that perceive the body temperature. We implemented a 3D horror game whose game space is a common subway space ordinarily encountered in daily life so that ordinary people can easily get used to the game environment. The experiments of applying the measurement data from the game player to the game world avatar shows that the player's physical status can be effectively utilized to improve the sense of reality in gameplay.

Nondestructive Measurement on Electrical Characteristics of Amorphous Silicon by Using the Laser Beam (레이저 빔을 이용한 비정질실리콘 전기적 특성의 비파괴 측정)

  • 박남천
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.36-39
    • /
    • 2000
  • A small electrical potential difference which appears on any solid body when subjected to illumination by a modulated light beam generated by laser is called photocharge voltage(PCV)[1,2]. This voltage is proportional to the induced change in the surface electrical charge and is capacitatively measured on various materials such as conductors, semiconductors, ceramics, dielectrics and biological objects. The amplitude of the detected signal depends on the type of material under investigation, and on the surface properties of the sample. In photocharge voltage spectroscopy measurements[3], the sample is illuminated by both a steady state monochromatic bias light and the pulsed laser. The monochromatic light is used to created a variation in the steady state population of trap levels in the surface and space charge region of semiconductor samples which does result in a change in the measured voltage. Using this technique the spatial variation of PCV can be utilized to evaluate the surface conditions of the sample and the variation of the PCV due to the monochromatic bias light are utilized to characterize the surface states. A qualitative analysis of the proposed measurement is present along with experimental results performed on amorphous silicon samples. The deposition temperature was varied in order to obtain samples with different structural, optical and electronic properties and measurements are related to the defect density in amorphous thin film.

  • PDF

A Literature Review for an Emotion Evaluation Protocols Based on Skin Temperature for Home Appliances (피부온을 기반으로 한 가전제품의 감성 평가 프로토콜 수립을 위한 문헌 조사)

  • Jeon, Eun-Jin;Lee, Seung-hoon;Kim, Hee-Eun;You, Hee-Cheon
    • Fashion & Textile Research Journal
    • /
    • v.22 no.2
    • /
    • pp.240-249
    • /
    • 2020
  • This study reviews studies that used skin temperature in order to establish an emotion evaluation protocol based on skin temperature for home appliances. A survey of skin temperature evaluation papers was conducted by the following five stages: (1) keyword search, (2) title screening, (3) abstract screening, (4) full paper screening, and (5) relevance evaluation. Selected papers were reviewed for: purpose, recruitment criteria of participants, the number of participants, apparatus, procedure, measures, analysis methods, and major findings. Thermistor sensors and thermography are used for the measurement of skin temperature. Skin temperature sensors are attached to 4 - 10 locations on the body and their mean of skin temperature is calculated by Ramanatan's 4-point or Hardy & Dubois's 7-point method. Semantic differential (SD) method and thermography measuring facial surface temperature have been used for emotion evaluation. The SD method provides a set of adjective pairs related to a product and evaluates changes in emotion from the use of the product. The range of facial surface analyzed is defined in the thermal image and temperature changes before and after the evaluation are analyzed. The evaluation items of home appliances include form, color, material, aesthetics, satisfaction, novelty, convenience, pleasantness, and excellence. Many existing emotion studies using skin temperature do not apply physiological and psychological methods. This study provides basic data to establish a skin temperature and emotion evaluation protocol by examining literature for skin temperature and evaluation of sensitivity.

Thermal imaging and computer vision technologies for the enhancement of pig husbandry: a review

  • Md Nasim Reza;Md Razob Ali;Samsuzzaman;Md Shaha Nur Kabir;Md Rejaul Karim;Shahriar Ahmed;Hyunjin Kyoung;Gookhwan Kim;Sun-Ok Chung
    • Journal of Animal Science and Technology
    • /
    • v.66 no.1
    • /
    • pp.31-56
    • /
    • 2024
  • Pig farming, a vital industry, necessitates proactive measures for early disease detection and crush symptom monitoring to ensure optimum pig health and safety. This review explores advanced thermal sensing technologies and computer vision-based thermal imaging techniques employed for pig disease and piglet crush symptom monitoring on pig farms. Infrared thermography (IRT) is a non-invasive and efficient technology for measuring pig body temperature, providing advantages such as non-destructive, long-distance, and high-sensitivity measurements. Unlike traditional methods, IRT offers a quick and labor-saving approach to acquiring physiological data impacted by environmental temperature, crucial for understanding pig body physiology and metabolism. IRT aids in early disease detection, respiratory health monitoring, and evaluating vaccination effectiveness. Challenges include body surface emissivity variations affecting measurement accuracy. Thermal imaging and deep learning algorithms are used for pig behavior recognition, with the dorsal plane effective for stress detection. Remote health monitoring through thermal imaging, deep learning, and wearable devices facilitates non-invasive assessment of pig health, minimizing medication use. Integration of advanced sensors, thermal imaging, and deep learning shows potential for disease detection and improvement in pig farming, but challenges and ethical considerations must be addressed for successful implementation. This review summarizes the state-of-the-art technologies used in the pig farming industry, including computer vision algorithms such as object detection, image segmentation, and deep learning techniques. It also discusses the benefits and limitations of IRT technology, providing an overview of the current research field. This study provides valuable insights for researchers and farmers regarding IRT application in pig production, highlighting notable approaches and the latest research findings in this field.

Long-term monitoring of ground anchor tensile forces by FBG sensors embedded tendon

  • Sung, Hyun-Jong;Do, Tan Manh;Kim, Jae-Min;Kim, Young-Sang
    • Smart Structures and Systems
    • /
    • v.19 no.3
    • /
    • pp.269-277
    • /
    • 2017
  • Recently, there has been significant interest in structural health monitoring for civil engineering applications. In this research, a specially designed tendon, proposed by embedding FBG sensors into the center king cable of a 7-wire strand tendon, was applied for long-term health monitoring of tensile forces on a ground anchor. To make temperature independent sensors, the effective temperature compensation of FBG sensors must be considered. The temperature sensitivity coefficient ${\beta}^{\prime}$ of the FBG sensors embedded tendon was successfully determined to be $2.0{\times}10^{-5}^{\circ}C^{-1}$ through calibrated tests in both a model rock body and a laboratory heat chamber. Furthermore, the obtained result for ${\beta}^{\prime}$ was formally verified through the ground temperature measurement test, expectedly. As a result, the ground temperature measured by a thermometer showed good agreement compared to that measured by the proposed FBG sensor, which was calibrated considering to the temperature sensitivity coefficient ${\beta}^{\prime}$. Finally, four prototype ground anchors including two tension ground anchors and two compression ground anchors made by replacing a tendon with the proposed smart tendon were installed into an actual slope at the Yeosu site. Tensile forces, after temperature compensation was taken into account using the verified temperature sensitivity coefficient ${\beta}^{\prime}$ and ground temperature obtained from the Korean Meteorological Administration (KMA) have been monitored for over one year, and the results were very consistent to those measured from the load cell, interestingly.

Design of a non-contacting single infrared sensor for high frequency dental casting machine (치과용 고주파 주조기를 위한 비접촉 단일 온도센서 설계)

  • Hwang, In;Won, Yonggwan;Lee, Sang-Hun;Song, Sung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1546-1552
    • /
    • 2016
  • In addition, because it uses preheating to dissolve an alloy in general, it is hard to regulate the appropriate melting temperature of the alloy and brewing time and shows the defect of the supplementation thing due to the super-heating. Once the alloy is molten and then most of the casting by attaching a sight glass or non-contact temperature sensor is suitable casting temperature the operator pressing a button to generate a centrifugal force to inject the molten alloy into a crucible in the casting ring. These results, and most of the cast temperature is too high or too low to generate a lot of casting defects do not get into a uniform cast body. In this paper, we developed a dental casting machine for high frequency using a single temperature sensor which can measure the actual temperature of the alloy than the temperature of the external non-contact measurement using a temperature sensor.

Development of an Eye Patch-Type Biosignal Measuring Device to Measure Sleep Quality (수면의 질을 측정하기 위한 안대형 생체신호 측정기기 개발)

  • Changsun Ahn;Jaekwan Lim;Bongsu Jung;Youngjoo Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.5
    • /
    • pp.171-180
    • /
    • 2023
  • The three major sleep disorders in Korea are snoring, sleep apnea, and insomnia. Lack of sleep is the root of all diseases. Some of the most serious potential problems associated with sleep deprivation are cardiovascular problems, cognitive impairment, obesity, diabetes, colitis, prostate cancer, etc. To solve these problems, the Korean government provided low-cost national health insurance benefits for polysomnography tests in July 2018. However, insomnia patients still have problems getting treated in terms of time, space, and economic perspectives. Therefore, it would be better for insomnia patients to be allowed to test at home. The measuring device can measure six biosignals (eye movement, tossing and turning, body temperature, oxygen saturation, heart rate, and audio). A gyroscope sensor (MPU9250, InvenSense, USA) was used for eye movement, tossing, and turning. The input range of the sensor was in 258°/sec to 460°/sec, and the data range was in the input range. Body temperature, oxygen saturation range, and heart rate were measured by a sensor (MAX30102, Analog Devices, USA). The body temperature was measured in 30 ℃ to 45 ℃, and the oxygen saturation range was 0% for the unused state and 20 % to 90 % for the used state. The heart rate measurement range was in 40 bpm to 180 bpm. The measurement of audio signal was performed by an audio sensor (AMM2742-T-R, PUIaudio, USA). The was -42 dB ±1 dB frequency range was 20 Hz to 20 kHz. The measured data was successfully received in wireless network conditions. The system configuration was consisted of a PC and a mobile app for bio-signal measurement and data collection. The measured data was collected by mobile phones and desktops. The data collected can be used as preliminary data to determine the stage of sleep and perform the screening function for sleep induction and sleep disturbances. In the future, this convenient sleep measurement device could be beneficial for treating insomnia.

A Study on the Correlation between of Bone Mineral Density and Cold Hypersensitivity of Hands (골밀도와 수냉증과의 상관성 연구)

  • Lee, Dong-Nyung;Lee, Jeong-Im;Go, Ho-Yeon;Kim, Hyung-Jun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.4
    • /
    • pp.11-20
    • /
    • 2015
  • Objectives The purpose of this study was to examine the relationship between cold hypersensitivity and bone mineral density. Methods 28 outpatients who visited OO University Oriental Hospital from July 11th, 2013 to August 28th, 2013 were analyzed. Patients were subjected to thermometer, and those with thermal difference greater than 0.3 ℃ between upper arm and palm and also with more than VAS 4 of cold hypersensitivity were diagnosed with cold sensitivity. Lumba spine (L2-4) and heel bone measurement were obtained on dual energy X-ray absorptiometry (DEXA) and Quantitative Computed Tomography (QCT). Results 1. There was statistically significant correlation between T-score of DEXA and body weight (0.522), BMI (0.643), OSTA (Osteoporosis elf-assesment Tool for Asians, 0.579), BMI, T-score and Z-score of QCT. OSTA and T-score of QCT (0.521) also had statistically significance. 2. There was no statistically significant correlation between body fat, abdominal obesity rate, degree of cold hypersensitivity, upper arm and palm's temperature difference, palm temperature, height and Z-score, T-score of QCT or T-sore of DEXA. Conclusions Bone mineral density was lower in women who had cold hypersensitivity of hand and feet. But there was no statistically significant correlation between bone mineral density and degree of cold hypersensitivity, upper arm and palm’s temperature difference.

New Approach to Air Quality Management (대기오염관리의 새로운 접근방법)

  • 윤명조
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.25-48
    • /
    • 1993
  • International concern over the environmental pollution is ever increasing, and diversified countermeasures must be devised in Korea also. Global trend, damages, problems and countermeasures with respect to issues mentioned in the Rio Declaration, such as prevention of ozone layer destruction, reduction of migratory atmospheric pollution between neighboring countries, and prevention of global greenhouse effect, were discussed in this report. Conclusion of the report is summarized as follows : A. Measurement, Planning and Monitoring (1) Development and implementation of a global network for measurement and monitoring from the global aspects such factors as related to acid rain(Pioneer substances, pH, sulfate, nitrate), effect of global temperature(Air temperature, $CO_2$, $CH_4$, CFC, $N_2O$) and destruction of ozone layer($CFC_S$). (2) Establishment of network system via satellite monitoring movement of regional air mass, damage on the ozone layer and ground temperature distribution. B. Elucidation of Present State (1) Improvement and development of devices for carbon circulation capable of accurately forecasting input and output of carbon. (2) Developmental research on chemical reactions of greenhouse gas in the air. (3) Improvement and development of global circulation model(GCM) C. Impact Assessment Impact assessment on ecosystem, human body, agriculture, floodgate, land use, coastal ecology, industries, etc. D. Preventive Measures and Technology Development (1) Development and consumption of new energy (2) Development of new technology for removal of pioneer substances (3) Development of substitute matter for $CFC_S$ (4) Improvement of agriculture and forestry means to prevent the destruction of ozone layer and the greenhouse effect of the globe (5) Improvement of housing to prevent the destruction of ozone layer and the greenhouse effect of the globe (6) Development of new technology for probing underground water (7) Preservation of forest (8) Biomass 5. Policy Development (1) Development of strategy model (2) Development of long term forecast model (3) Development of penalty charge effect and expense evaluation methods (4) Feasibility study on regulations By establishing the above mentioned measures for environmentally sound and sustainable development to establish the right to live for humankind and to preserve the one and only earth.

  • PDF

The Developement of a Wind Direction/Speed Measurement Equipment Using RTD or Piezo Sensors (RTD 및 피에조 센서를 활용하는 풍향/풍속 측정장치 개발)

  • Joo, Jae-Hun;Kim, Dong-Hyun;Gong, Byung-Gunn;Lee, Jin-Ho;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.827-830
    • /
    • 2011
  • In this paper, a wind speed & direction module and the DSP(Digital Signal Processor) sensor interface circuit board are proposed. This DSP system accepts and process the informations from a wind speed & direction module, the atmospheric pressure sensor, the ambient air temperature sensor and transfers it to the PC monitering system. Especially, a wind speed & direction module and a DSP hardware are directly designed and applied. A wind speed & direction module have a construction that it have four film type RTD(Resistive Temperature Detectors) or film type Piezo sensors adhered around the circular metal body for obtaining vector informations about wind. By this structure, the module is enabled precise measurement having a robustness about vibration, humidity, corrosion. A sensor signal processing circuit is using TMS320F2812 TI(Texas Instrument) Corporation high speed DSP.

  • PDF