• Title/Summary/Keyword: Body scan

Search Result 574, Processing Time 0.022 seconds

Analysis of Middle-aged Men's Frontal Body Shape Asymmetry using 3D Body Scan Data (3차원 인체 스캔 데이터를 활용한 중년 남성 정면 비대칭 체형 특성 분석)

  • Minseon Lee;Dong-Eun Kim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.47 no.3
    • /
    • pp.511-530
    • /
    • 2023
  • This study aims to analyze middle-aged men's frontal body shape asymmetry by measuring the left and right body dimensions and angles of 388 middle-aged men aged 40 to 59 using 3D body scan data and comparing the measured values. The study also compares the measured values of width, height, and angle and their relationships using Size Korea's anthropometric measurement and posture index of the New York Posture Rating Scale. The results confirm that the asymmetric shape characteristics of the upper and lower body appear differently. In addition, the asymmetrical characteristics between the upper and lower body differed, indicating that the close parts of the body affect each other. Similar to the difference in the left and right frontal body shapes and the average angle distribution, the asymmetrical upper and lower body characteristics also are found to be dissimilar when the correlations are examined. In contrast, there is no asymmetry in the width, height, and angle considering the age and BMI groups. Finally, the study classifies three body types and identifies their asymmetric characteristics. Overall, this study contributes primary data for further research on pattern production for asymmetric and unique body types and the development of customized apparel products.

The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner - (3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 -)

  • Park, Sun-Mi;Nam, Yun-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

Classification of adult male torso shapes using 3D body scan data (3D 스캔 데이터에 의한 성인 남성의 체간부 형태 유형화)

  • Hong, Eun-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.21 no.4
    • /
    • pp.165-179
    • /
    • 2019
  • This study used 3D body scan data to classify body shapes according to the torso shape of adult males aged 20-75 years. This data will be provided so that the apparel industry can make apparel products corresponding to body characteristics by age. The study used 1,796 adult males between the ages of 20 and 75 and the 3D body shape data of the '5th Research on National Standard Anthropometry'. For data analysis, the program SPSSWIN Ver. 17.0 was used to calculate the mean and frequency allowing for a factor analysis, cluster analysis, analysis of variance, and Duncan test. To classify body shape according to the torso shape of adult males, this study considered nine factors: 'horizontal size of torso,' 'vertical size of body,' 'curve of torso and waist-abdomen flatness ratio,' 'length of torso,' 'shape of neck area,' 'degree of lateral curve,' 'difference between front and back interscye length,' 'shoulder armscye shape,' and 'chest flatness ratio.' Based on the results of the factor analysis, the torso shapes of adult males were classified into five types. Type 1 is "upright body with flat, curvy shape", Type 2 is "curve sway back body type", Type 3 is "flat, abdominally obese body", Type 4 is "obese, crooked body" and Type 5 is "thick sway front body type." named.

Performance testing of a FastScan whole body counter using an artificial neural network

  • Cho, Moonhyung;Weon, Yuho;Jung, Taekmin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3043-3050
    • /
    • 2022
  • In Korea, all nuclear power plants (NPPs) participate in annual performance tests including in vivo measurements using the FastScan, a stand type whole body counter (WBC), manufactured by Canberra. In 2018, all Korean NPPs satisfied the testing criterion, the root mean square error (RMSE) ≤ 0.25, for the whole body configuration, but three NPPs which participated in an additional lung configuration test in the fission and activation product category did not meet the criterion. Due to the low resolution of the FastScan NaI(Tl) detectors, the conventional peak analysis (PA) method of the FastScan did not show sufficient performance to meet the criterion in the presence of interfering radioisotopes (RIs), 134Cs and 137Cs. In this study, we developed an artificial neural network (ANN) to improve the performance of the FastScan in the lung configuration. All of the RMSE values derived by the ANN satisfied the criterion, even though the photopeaks of 134Cs and 137Cs interfered with those of the analytes or the analyte photopeaks were located in a low-energy region below 300 keV. Since the ANN performed better than the PA method, it would be expected to be a promising approach to improve the accuracy and precision of in vivo FastScan measurement for the lung configuration.

Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring (직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석)

  • Istook, Cynthia L.;Lim, Ho-Sun;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.

Development of an Algorithm for Automatic Extraction of Lower Body Landmarks Using Grasshopper Programming Language (Grasshopper 프로그래밍 기반 3D 인체형상의 하반신 기준점 자동탐색 알고리즘 설계)

  • Eun Joo Ryu;Hwa Kyung Song
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.47 no.1
    • /
    • pp.171-190
    • /
    • 2023
  • This study aims to develop algorithms for automatic extraction landmarks from the lower body of women aged 20-54 using the Grasshopper programming language, based on 3D scan data in the 8th SizeKorea dataset. First, 11 landmarks were defined using the morphological features of 3D body surfaces and clothing applications, from which automatic landmark extraction algorithms were developed. To verify the accuracy of the algorithm, this study developed an additional algorithm that could automatically measure 16 items, and algorithm-derived measurements and SizeKorea measurements were compared using paired t-test analysis. The statistical differences between the scan-derived measurements and the SizeKorea measurements were compared, with an allowable tolerance of ISO 20685-1:2018. This study found that the algorithm successfully identified most items except for the crotch point and gluteal fold point. In the case of landmarks with significant differences, the algorithms were modified. This study was significant because scan editing, landmark search, and measurement extraction were successfully performed in one interface, and the developed algorithm has a high efficiency and strong adaptability.

An Accuracy Analysis of the 3D Automatic Body Measuring Machine (3차원 자동체형계측기 정밀도 검사)

  • Jeon, Soo-Hyung;Kwon, Suk-Dong;Park, Se-Jung;Kim, Jung-Yang;Song, Jung-Hoon;Kim, Hyun-Jin;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.20 no.1
    • /
    • pp.42-47
    • /
    • 2008
  • 1. Objectives The Body Shape and Feature is one of the important standard for classification of Sasang Constitutions. In order to evaluate one's Body Shape and Feature objectively we have been developing the Body Measuring Machine. Now we develop the 3D Automatic Body Measuring Machine(3D-ABMM). So we make an analysis of the 3D-ABMM's Accuracy. 2. Methods By using the 3D-ABMM and Vivid 9i(3D laser scanner, Konica Minolta) we have a surface scan of the three objects which are the upper body of the female and male Manikin and a male model. We overlap each scan data using the RapidForm2006 (3D scan data solution, INUS Technology) and calculate the average distance and standard deviation between the same point of each scan data. 3. Results and Conclusions In the female Manikin, the average distance is 0.84mm and the standard deviation is 1.16mm and the maximum distance is 10.68mm. In the male Manikin, the average distance is 1.12mm and the standard deviation is 1.19mm and the maximum distance is 12.00mm. In the male model, the average distance is 3.26mm and the standard deviation is 2.59mm and the maximum distance is 12.75mm. From the results, 3D-ABMM has good accuracy for scanning body and will be a usable hardware of the 3D Automatic Body Analysis Machine.

  • PDF

2D Pattern Development of Body Surface from 3D Human Scan Data Using Standing and Cycling Postures (3D 스캔을 이용한 사이클 동작 전후 체표 변화 고찰 및 2D 전개 패턴의 비교)

  • Jeong, Yeonhee;Lee, Yejin
    • Korean Journal of Human Ecology
    • /
    • v.21 no.5
    • /
    • pp.975-988
    • /
    • 2012
  • Although the pattern development for tight-fitting clothing has been carried out using 3D data on humans, the pattern development using 3D scan data obtained for various postures still remains an interesting subject. In this study, we have developed the 2D pattern using the 3D human body reflecting standing and cycling postures. The 3D scan data of a subject was obtained using Cyberware. 2C-AN program(Triangle simplification and the Runge-Kutta method) was used in the system to reduce the 3D scan data points and to make segmented triangular patches in a plane from 3D data. As results, surface distance and area of each body part of standing and cycling postures were also provided for the future application of the functional clothing construction. The area of center piece on the front (c.front) decreased by $106.45cm^2$(-13.08%) and that of lateral piece(s.back) on the back increased by $144.96cm^2$(18.69%) in the patterns of cycling posture. The girth of neck and waist for the cycling posture increased by 0.88cm (3.92%) and 1.56cm(4.40%) respectively, and the that of thigh decreased by 1.01cm(-2.24%). The differences between the area in the 2D pattern obtained from the 3D scan data and that in the 3D scan surface data for standing and cycling postures were very small($-10.34cm^2$(-0.32%) and $-44.33cm^2$(-1.32%)).

Comparision of I-131 Diagnostic Scan and Therapeutic Scan in Thyroid Carcinoma (갑상선암 환자에서 I-131의 진단적 전신스캔과 치료후 전신스캔의 비교)

  • Lee, Bum-Woo;Lee, Dong-Soo;Moon, Dae-Hyuk;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.80-86
    • /
    • 1990
  • Fifty seven patients with differentiated thyroid carcinoma were performed radioactive iodine-131 whole body scans after administration of diagnostic dose $(2\sim10\;mCi)$ and therapeutic dose $(30\sim150\;mCi)$ within three months. We evaluated the state of radioactive iodine-131 uptakes in whole body scan to detect correct metastasis of thyroid carcinoma. The results are as follows: 1) In 20 of the 57 patients (35%), the therapeutic scan showed the additional uptakes that were not seen in the diagnostic scan. 2) In 9 (64.2%) of the 14 patients who had been received the thyroid ablation theraphy with I-131 previously, new additional lesions were found in the therapeutic scan but only 11 (25%) of the 32 patients who had not been received the thyroid ablation theraphy disclosed new uptake lesions (p < 0.01). 3) The additional uptake lesions of therapeutic scan were significantly more common in the bony metastatic foci (55.7%) than other areas (p < 0.01). In 11 (55%) of 20 patients, additional uptake regions were anterior neck areas (thyroid bed or regional lymph node). We conclude that diagnostic scan with $2\sim5$ mCi I-131 is inadequate in evaluating residual iodine avid tissues of patients with thyroid carcinoma. Also post-theraphy I-131 whole body scan would be important to evaluate the correct staging and prognosis of thyroid carcinoma, and to follow-up patients.

  • PDF

Belt Pattern Making for Hip-hugger garment using 3D Body Scan Data (3차원 인체 스캔 데이터를 활용한 Hip-hugger 의류용 벨트 패턴 설계)

  • Park, Soon-Jee;Choi, Sin-Ae
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.652-659
    • /
    • 2008
  • This study was designed to testify the possibility and devise the method to manipulate the 3D body scan data to produce rounded-belt pattern adaptable to hip-type variation of women in their 20's. The results of this research were as follows : Firstly, based on drop-value distribution of hip and waist girth, 151 subjects were classified into three hip-types; Type 1 (15.23%) was 'cylinder type', showing lowest drop-value, Type 2 (69.54%) was 'average type' and Type3 (15.23%) was 'hourglass type' showing highest drop-value. Secondly, using CAD program, design lines for round shape belt were set on the surface of 3D scan data of representative subject of each type. And divided 3D surfaces were flattened onto the plane by the internal tools of CAD program. The measure, 'lifting value of round belt pattern', implying the level of curve ratio of pattern was higher in back than front. This result might be linked to the fact that the hip part is more protruded than the abdomen part. And the measures also showed highest values in Type 3(hourglass type) and lowest in Type 1(cylinder type), meaning that the pattern of Type 3 showed more rounded shape than that of Type 1. This finding implied that round belt for body type having high drop-value should be shaped more curved. Thirdly, difference ratios of outline length and area between 3D curves(body surface) and 2D plane(pattern) were 4.5% and 1.3%, respectively. This result demonstrated and solidified the feasibility of designing digital garment pattern from 3D body scan data.