• Title/Summary/Keyword: Body performance

Search Result 4,331, Processing Time 0.033 seconds

Nutritional efficiency of feed restricted F1 Holstein/Zebu cows during the middle third of lactation

  • Santana, Pedro Felipe;Junior, Vicente Ribeiro Rocha;Ruas, Jose Reinaldo Mendes;Moncao, Flavio Pinto;Borges, Luana Alcantara;Sousa, Thais Eleonora Santos;Silva, Fredson Vieira e;Rabelo, Walber de Oliveira;Carvalho, Cinara da Cunha Siqueira;Sales, Eleuza Clarete Junqueira de
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.2
    • /
    • pp.236-244
    • /
    • 2020
  • Objective: The objective of this study was to evaluate the effects of different levels of quantitative feed restriction on nutrient intake and digestibility, nitrogen balance, efficiency and feeding behavior, and productive performance in F1 Holstein/Zebu cows during the middle third of their lactation. Methods: Sixty F1 Holstein/Zebu cows with 111.5±11.75 days of lactation and an initial body weight (BW) of 499±30 kg (mean±standard error of the mean) were used. The experimental design was completely randomized with the following diet levels of feed restriction: 3.39%, 2.75%, 2.50%, 2.25%, and 2.00% of BW, with 12 replications for each level. The experiment lasted for 63 days, of which each period lasted 21 days with the first 16 days for diet adaptation followed by 5 days for collection of data and samples. Results: For each 1% of BW diet restriction, there was a decrease in dry matter intake of 5.26 kg/d (p<0.01). There was no difference in daily milk production (p = 0.09) under the restriction levels of 3.39% to 2.0% of BW. When corrected for 3.5% fat, milk production declined (p = 0.05) 3.46 kg/d for each percentage unit of feed restriction. Conclusion: Restricting the feed supply for F1 Holstein/Zebu cows in the middle third of their lactation period altered nutrient intake, nitrogen balance and ingestive behavior but did not affect milk production or feed efficiency. However, considering the observed BW loss and decrease in milk production corrected for 3.5% fat, restriction of no less than 2.5% BW is recommended.

Effects of Feed Rate and Screw Speed of Extruded Diets on Growth and Body Composition of Olive Flounder Paralichthys olivaceus (사료원료 공급량 및 스크류 회전속도를 달리하여 제조한 배합사료가 넙치(Paralichthys olivaceus)의 성장 및 체조성에 미치는 영향)

  • Kim, Kyoung-Duck;Kim, Kang-Woong;Lee, Bong-Joo;Bae, Ki-Min;An, Cheul-Min;Han, Hyun-Sob
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.5
    • /
    • pp.577-581
    • /
    • 2014
  • The aim of this study was to investigate the effect of diet extruder conditions, such as feed-loading rate and screw speed, on growth performance and biochemical responses in olive flounder Paralichthys olivaceus. Over 8 wks, we used four identical diets (triplicated per treatment) with differing ratios of feed-loading rate (kg/h):screw speed (rpm/min) in a laboratory-scaled twin-screw extruder of 50:640, 80:640, 120:640, and 80:400, designated as EP1, EP2, EP3, and EP4, respectively. Screw speed impacted the buoyancy of experimental diets. Diets produced at a screw speed of 640 rpm/min floated for > 24 hrs, whereas those produced at a speed of 400 rpm/min sank between 10 s and 5 min. Fish that were fed EP1 and EP4 diets grew significantly faster than those fed EP2 and EP3 diets. Fish fed EP1 diets ate and gained weight most efficiently among treatments, a result that is likely to be related to feed-loading rate, i.e., ingredients extruded at a low feed-loading rate may have more time to cook in the pre-conditioner of the extruder. A cooked diet may be easier to digest in fish. Fish fed EP4 diets also showed significant weight gain, as compared to those fed EP2 and EP3 diets. However, we found no differences among treatments in proximate compositions of dorsal muscle, liver, and viscera of fish. Our results suggest that extruder conditions, may influence feed quality, impacting feed efficiency and growth of fish.

Optimum Feeding Rate in Growing Olive Flounder Paralichthys olivaceus Fed Practical Expanded Pellet at Optimum Water Temperature (19-21℃) (적수온(19-21℃)에서 배합사료를 공급한 육성기 넙치(Paralichthys olivaceus)의 적정 공급률)

  • Lee, Jeong-Ho;Kim, Sung-Sam;Kim, Kang-Woong;Kim, Kyoung-Duck;Lee, Bong-Joo;Lee, Jin-Hyeok;Han, Hyon-Sob;Kim, Jae-Won;Kim, Sung-Yeon;Lee, Kyeong-Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.3
    • /
    • pp.234-240
    • /
    • 2014
  • We investigated the effects of feeding rate on the growth performance, blood components, and histology of growing olive flounder Paralichthys olivaceus. We determined the optimum feeding rate (initial fish mean weight of $240{\pm}10.9$ g) at the optimum water temperature. Two replicated groups of fish were fed a commercial diet at rates of 0%, 0.5%, 0.75%, and 1.0% body weight (BW) per day, and to satiation. Feeding trial was conducted using a flow-through system with 10 1.2-metric ton aquaria receiving filtered seawater at $19-21^{\circ}C$ for three weeks. Weight gain (WG) for fish fed to satiation was significantly higher than that of unfed fish and fish fed at 0.5% and 0.75% BW per day. The WG of fish fed at 1.0% BW per day was significantly higher than that of unfed fish and of fish fed at 0.5% BW per day. However, there were no significant differences in WG between fish fed at 0.5% BW per day and those fed at 0.75% BW per day, between fish fed at 0.75% BW per day and those fed at 1.0% BW per day, and between fish fed at 1.0% BW per day and those fed to satiation. The specific growth rates of fish fed at 1.0% BW per day and those fed to satiation were significantly higher than those of unfed fish and of fish fed at 0.5% BW per day. Broken-line regression analysis of weight gain showed that the optimum feeding rate of olive flounder weighing 240 g was 1.09% BW per day at the optimum water temperature.

Design Optimization for Kinematic Characteristics of Automotive Suspension considering Constraints (구속조건을 고려한 자동차 현가장치 기구특성의 최적설계)

  • Lee, Chang-Ro;Kim, Hyo-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.306-311
    • /
    • 2017
  • This paper deals with the design optimization of the kinematic characteristics of an automotive suspension system. The kinematic characteristics of the suspension determine the attitude of the wheels, such as the toe and camber, which not only relates to tire wear during driving, but also greatly affects the control of the vehicle and its stability, which corresponds to the motion performance of the vehicle. Therefore, it is very important to determine the characteristics of the suspension mechanism at the initial stage of the design. In this study, a displacement analysis is performed to determine the kinematic properties of the suspension for the McPherson strut suspension. For this purpose, a set of constraint equations for the joints constituting the suspension mechanism was established and a program was developed to solve them. We also used ADS, a design optimization program, to obtain the desired kinematic characteristics of the suspension. As the design variables for optimization, we used the coordinates of the hard points, which are the points of attachment of the suspension to the vehicle body, and are defined as the summation of the toe-in for the up and down movement of the wheel as the objective function. As the constraint functions, the maximum camber angle and minimum roll center height, which are design requirements, are considered. As a result of this study, it was possible to determine the optimal locations of the hard points that satisfy both constraint functions and minimize the change of the toe-in.

A Design of Key Generation and Communication for Device Access Control based on Smart Health Care (스마트 헬스케어 기반의 디바이스 접근제어를 위한 키 생성 및 통신기법 설계)

  • Min, So-Yeon;Lee, Kwang-Hyong;Jin, Byung-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.746-754
    • /
    • 2016
  • Smart healthcare systems, a convergent industry based on information and communications technologies (ICT), has emerged from personal health management to remote medical treatment as a distinguished industry. The smart healthcare environment provides technology to deliver vital information, such as pulse rate, body temperature, health status, and so on, from wearable devices to the hospital network where the physician is located. However, since it deals with the patient's personal medical information, there is a security issue for personal information management, and the system may be vulnerable to cyber-attacks in wireless networks. Therefore, this study focuses on a key-development and device-management system to generate keys in the smart environment to safely manage devices. The protocol is designed to provide safe communications with the generated key and to manage the devices, as well as the generated key. The security level is analyzed against attack methods that may occur in a healthcare environment, and it was compared with existing key methods and coding capabilities. In the performance evaluation, we analyze the security against attacks occurring in a smart healthcare environment, and the security and efficiency of the existing key encryption method, and we confirmed an improvement of about 15%, compared to the existing cipher systems.

The Comparison of Seakeeping Performance Analysis Methods for a High Speed Catamaran (Strip and 3-D Panel Method) (초고속 쌍동선에 대한 내항성능 해석 방법 비교 (스트립 방법과 3-D Panel 방법))

  • Lee, Ho-Young;Song, Ki-Jong;Yum, Deuk-Joon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.2
    • /
    • pp.127-138
    • /
    • 1996
  • The strip method, unified theory and 3-D panel method are commonly used methods for the seakeeping analysis of high-speed vessels. The strip method which is basically 2-dimensional method is known to give incorrect hydrodynamic coefficients and motion responses for the cases of high speed and low frequency region. And the unified theory which uses two dimensional approach in inner domain and slender body theory in outer domain is very complicate in computational modelling. Though the 3-D panel method requires comparatively long computation time, it is believed that the method gives good results without any limitation in ship speed and range of frequency for computation. In the 3-D panel method the source singularity representing translating and pulsating Green function is used and Hoff's method is adopted for the numerical calculation of the Green function. The computation time can be reduced by using the symmetry relationship with respect to longitudinal axis. In this paper the strip method and the 3-D panel method are compared for the seakeeping analysis of a high-speed catamaran. The Compared items are the hydrodynamic coefficients, wave exciting forces, frequency response functions and short-term responses in irregular waves.

  • PDF

Psychometric Validation of the Bahasa Malaysia Version of the EORTC QLQ-CR29

  • Magaji, Bello Arkilla;Moy, Foong Ming;Roslani, April Camilla;Law, Chee Wei;Raduan, Farhana;Sagap, Ismail
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8101-8105
    • /
    • 2016
  • Background: This study examined the psychometric properties of the Bahasa Malaysia (BM) version of the European Organization for Research and Treatment of Cancer (EORTC) Colorectal Cancer-specific Quality Of Life Questionnaire (QLQ-CR29). Materials and Methods: We studied 93 patients recruited from University Malaya and Universiti Kebangsaan Medical Centers, Kuala Lumpur, Malaysia using a self-administered method. Tools included QLQ-C30, QLQ-CR29 and Karnofsky Performance Scales (KPS). Statistical analyses included Cronbach's alpha, test-retest correlations, multi-traits scaling and known-groups comparisons. A p vaue ${\leq}0.05$ was considered significant. Results: The internal consistency coefficients for body image, urinary frequency, blood and mucus and stool frequency scales were acceptable (Cronbach's alpha ${\alpha}{\geq}0.65$). However, the coefficients were low for the blood and mucus and stool frequency scales in patients with a stoma bag (${\alpha}=0.46$). Test-retest correlation coefficients were moderate to high (range: r = 0.51 to 1.00) for most of the scales except anxiety, urinary frequency, buttock pain, hair loss, stoma care related problems, and dyspareunia (r ${\leq}0.49$). Convergent and discriminant validities were achieved in all scales. Patients with a stoma reported significantly higher symptoms of blood and mucus in the stool, flatulence, faecal incontinence, sore skin, and embarrassment due to the frequent need to change the stoma bag (p < 0.05) compared to patients without stoma. None of the scales distinguished between patients based on the KPS scores. There were no overlaps between scales in the QLQ-C30 and QLQ-CR29 (r < 0.40). Conclusions: the BM version of the QLQ-CR29 indicated acceptable psychometric properties in most of the scales similar to original validation study. This questionnaire could be used to complement the QLQ-C30 in assessing HRQOL among BM speaking population with colorectal cancer.

Implementation of Segway Using Pressure Sensors (압력센서를 이용한 세그웨이 개발)

  • Jo, Sung-Chan;Kang, Su-Min;Huh, Kyung-Moo;Joo, Young-Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.285-290
    • /
    • 2013
  • As well as the advanced development of modern society, and the environmental problems caused by the use of fossil fuels is emerging. So do not reap the performance level of the car to be able to replace existing fossil fuel and low-emission energy and technology development are continually strives. Therefore, this study aims to present the direction of the new interface 21st century Mobile Auto Electric Segway technology in the field of security and disadvantages based. The Segway is a problem because the control itself skewed by certain slope where the slope in the wrong adjustment tipping. In this study, the year saw the introduction of two pressure sensors(Load cell) used to solve these drawbacks, according to the ratio of the weight control methods. In addition, the ramps operate in a straightforward, using an acceleration sensor and a gyro sensor in order to compensate for the slope value in free control method to study looked. Measured by calculating the value of the occupant's weight and according to the inclination of the pressure sensor pressure sensing experiment results this year, we can see that the control variable for the change in body weight is greater than the inclination. Segway is also easy to control, and the stability of the ramps, etc. As a result, created using a pressure sensor.

A Study on Exercise Intervention for Improving Physical Activity for the Disabled: From the Perspective of Convergence Device (장애인 신체활동 증가를 위한 운동중재에 관한 연구: 융합형 디바이스 활용 관점에서)

  • Kang, Sunyoung
    • Convergence Security Journal
    • /
    • v.19 no.5
    • /
    • pp.85-90
    • /
    • 2019
  • The purpose of this study is to analyze the trend of exercise intervention applying various devices to increase the physical activity of the disabled, and to suggest the exercise intervention using converged devices that meet the needs of the times due to the increase of elderly people with disabilities. Exercise intervention using converged devices applicable to the disabled is divided into two types: first, exercise intervention using virtual reality-based gamification, and second, exercise intervention based on wearable devices of wearable or body-attached such as bands and watches. For exercise intervention using converged devices that can be enjoyed by the elderly with disability, minimize of environmental limitations, and easy to personalize, there is a need for configuration requirements such as easy operation and simple rules of operation, easy device installation and wearing, a trainer who can complement immature device utilization. In order to maintain and improve the daily living performance of the elderly with disabilities who experience a significant decrease in their cognitive and physical functions, it is necessary to use a physical activity game that can be experienced and can be interested in everyday life or a variety of devices to increase the amount of physical activity.

Detection of Heartbeat and Respiration Signal Using the Aircushion and the Frequency Domain Filter (에어쿠션 및 주파수 영역 필터를 이용한 호흡 및 심박 신호 검출)

  • Kim, Joo-Han;Cho, Sung-Pil;Shin, Jae-Yeon;Lee, Jeon;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.5
    • /
    • pp.33-42
    • /
    • 2010
  • In this study, we have proposed a simple cardiorespiratory monitoring method based on displacements of human body which occurs due to periodic heartbeat and breathing. The proposed system consists of an aircushion, pressure sensing hardware and heartbeat and respiration signals extraction algorithm. The aircushion was used for unconstrained measurement of the respiration and heartbeats without a sensor attached on the subject's skin surface. The displacements of subject sitting on the aircushion cause small pressure variations. These variations are amplified and filtered with the pressure sensing hardware. Finally, heart rate and respiration rate are extracted by signal processing algorithm based on frequency domain filter. To evaluate the performance, extracted respiration and heart rate from proposed system were compared with conventional methods. The average sensitivity of respiration and heart rate are 98.67% and 99.24%, respectively. These results show the proposed method has advantages of installing and processing simplicity so as to be used easily in unconstrained respiration and heart rate monitoring in daily life.