• Title/Summary/Keyword: Body mount

Search Result 98, Processing Time 0.025 seconds

Corrosion Behavior of Ti-6Al-4V Alloy after Plasma Electrolytic Oxidation in Solutions Containing Ca, P and Zn

  • Hwang, In-Jo;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.120-120
    • /
    • 2016
  • Ti-6Al-4V alloy have been used for dental implant because of its excellent biocompatibility, corrosion resistance, and mechanical properties. However, the integration of such implant in bone was not in good condition to achieve improved osseointergraiton. For solving this problem, calcium phosphate (CaP) has been applied as coating materials on Ti alloy implants for hard tissue applications because its chemical similarity to the inorganic component of human bone, capability of conducting bone formation and strong affinity to the surrounding bone tissue. Various metallic elements, such as strontium (Sr), magnesium (Mg), zinc (Zn), sodium (Na), silicon (Si), silver (Ag), and yttrium (Y) are known to play an important role in the bone formation and also affect bone mineral characteristics, such as crystallinity, degradation behavior, and mechanical properties. Especially, Zn is essential for the growth of the human and Zn coating has a major impact on the improvement of corrosion resistance. Plasma electrolytic oxidation (PEO) is a promising technology to produce porous and firmly adherent inorganic Zn containing $TiO_2(Zn-TiO_2)$coatings on Ti surface, and the a mount of Zn introduced in to the coatings can be optimized by altering the electrolyte composition. In this study, corrosion behavior of Ti-6Al-4V alloy after plasma electrolytic oxidation in solutions containing Ca, P and Zn were studied by scanning electron microscopy (SEM), AC impedance, and potentiodynamic polarization test. A series of $Zn-TiO_2$ coatings are produced on Ti dental implant using PEO, with the substitution degree, respectively, at 0, 5, 10 and 20%. The potentiodynamic polarization and AC impedance tests for corrosion behaviors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to +2000mV. Also, AC impedance was performed at frequencies ranging from 10MHz to 100kHz for corrosion resistance.

  • PDF

Sexual Behavior of Male Rats Following Damage to the Mammillary Bodies (유두체가 손상된 흰쥐 수컷의 성 행동)

  • Kim, Jong-Kyu;Kim, Chul
    • The Korean Journal of Physiology
    • /
    • v.6 no.1
    • /
    • pp.33-37
    • /
    • 1972
  • It was thought desirable to elucidate the influence of the mammillary bodies upon sexual behavior. Twenty male rats were used, of which 9 rats had their mammillary bodies damaged electrolytically through implanted electrodes (mammillary body group) and 11 rats received the same surgery short of electrolytic damage to the mammillary bodies (operated control group). Their sexual behavior was observed 3 weeks after surgery. Observation was discontinued when an ejaculation was followed by a successive intromission. 1. Mounting without intromission occurred significantly less often in the mammillary body group than in the operated control group. 2. No significant group difference existed with regard to the occurrence of mounting with intromission. However, the value tended to rise in the mammillary body group compared with the value of the operated control group. 3. Mountings with and without intromission tended to occure more often in the mammillary body group than in the operated control group, but the difference was nonsignificant. 4. The ejaculatory latency (time interval between the first intromission and the first ejaculation) and the postejaculatory interval (time interval between an ejaculatory act and the next intromission) tended to decrease in the mammillary body group compared with the values of the operated control group. However, again the difference did not reach significancy. 5. There existed no significant group differences with regard to the mounting latency (time interval between the first encounter with female and the first mounting with or without intromission), the intromission latency (time interval between the first encounter and the first intromission), and the interintromission period (mean time interval between two successive intromissions). From the above results, it may be inferred that the mammillary bodies tend to exert slight and nonsignificant inhibitory influence upon sexual behavior of male rats. However, further study is indicated before reaching final conclusion.

  • PDF

The Evaluation of Lateral Scatter Ray of Gamma Camera (Gamma Camera에 있어 측면 선란선의 영향에 대한 평가)

  • Kim, Jae-Il;Lee, Eun-Byeol;Cho, Seong-Wook;Noh, Kyeong-Woon;Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.46-50
    • /
    • 2018
  • Purpose Generally, a collimator that installed in front of detector set a direction of gamma ray and remove a scatter ray. By the way, a lateral or oblique scatter ray is detected into crystal through collimator. At this study, we will evaluate a mount of count and spectrums of lateral scatter ray. Materials and Methods We used the SKY LITE (philips, netherlands) as a gamma camera, and $^{99m}Tc$, 1.11 GBq point source as a phantom. we put this point source at backside 50 cm of detector. After acquiring this for 1 min, we turned a detector next 10 degrees. Likely this, we acquired images at every 10 degrees from $0^{\circ}$ to $360^{\circ}$, analyzed images and spectrums. In case of patient study, we choose a 3 phase bone scan patient who had a hand disease, because scatter rays from body would detect on crystal. After acquiring blood flow and blood pool images, we analyzed images and spectrums. Additional, we put a lead gown on patient's hand, body. And then we compared and evaluated 3 type blood pool images (non lead gown, lead gown on a hand and on body). Results In case of phantom study, scatter ray counts at backside ($270^{\circ}-90^{\circ}$) are same with a background count. By the way, counts of scatter ray of oblique side ($0^{\circ}-50^{\circ}$, $220^{\circ}-270^{\circ}$) are 100-600 cps, furthermore, counts at frontside are over 4 Mcps. In case of patient study, a counts of hand blood pool scan are 1510 cps. But counts of hand with lead gown on hands and on body are each 1554 cps, 1299 cps. Conclusion Therefore, even though there is a collimator in front of detector, lateral scatter rays detect on crystal and affect to images and spectrums. Especially, if there is a high activity source at outside of detector when we examine low activity organs like hands or foot, we have to shield and remove the source at outside for a good image.

A Study on Men's Costumes of the Parthian Period in Persia (페르시아 파르티아[Parthia]왕조 남자복식 연구)

  • YiChang Young-Soo
    • Journal of the Korean Society of Costume
    • /
    • v.56 no.4 s.103
    • /
    • pp.65-81
    • /
    • 2006
  • This is the study on the costumes of Parthian Period in Persia which had powerful influences on the Occidental and Western cultures in B.C 3 to A.D 3. With different types of Parthian costumes in each period, this study shows what types of costumes people used to wear and how they were co-related with its surrounding cultures. The ancient costumes of Korea had something to do with the elements of the Northern part at that time. To make an intensive study of Korean ancient costumes, these Parthian costumes which are known to those of northern nomadic tribes are studied to provide basis elements for study between the Korean styles and the exotic styles. The basic forms of the Parthian styles were jackets and trousers. They consisted of three kinds of jackets such as those to be adjusted In the front, tunics and coats. As for trousers, they were divided into three types such as those with horizontal pleats, round-side pleats and vertical pleats. 1) The jacket to be adjusted in the front was long enough to reach the hip and fit the body reasonably tight, and its neckline was shaped into V-type. It was a very popular style among the people of high and low classes. 2) The tunics had narrow sleeves. It was a one-piece pattern which reached the knees. It was settled with a belt on the waist. Its neckline was shaped into the round but its slit was not cleat. Its styles were into tight-fit and drapery ones. 3) The coats were almost similar to the jacket to be adjusted in the front with short length, but they were entirely long and open. They appeared later than the short jackets and the people of high class seemed to wear these styles. 4) 1'rousers with horizontal pleats - They had almost horizontal pleats on them, and they were a little tight. They seemed to be the early style in the Parthian period. 5) Trousers with round side-pleats - With saggy side pleats on them, these trousers had round pleats like a drapery style. This pattern was also considered Hellenistic elements shown in the Parthian costumes. The trousers consisted of the underdrawers and the leggings (called salwar or shalwar), which is thought to emphasize its functionality for its wearer to mount a horse with more ease. 6) Trousers with vertical pleats - With straight vertical pleats on them, these trousers had some volumes and bias decorations in the middle of them. These styles were thought to be worn by the ruling class of the Parthia from early to late period.

A Study on the Treatment of SD rat Menopausal Obesity Utilizing Fermentation Techniques (발효기법을 이용한 SD rat의 갱년기 비만 치료효과에 관한 연구)

  • Lee, Joung-Woon;Lee, Young-Chul;Kim, Dong-Hyun;Na, Hye-Sook;Ma, Jin-Yeul
    • Korean Journal of Clinical Pharmacy
    • /
    • v.15 no.2
    • /
    • pp.118-126
    • /
    • 2005
  • In our study, osteoporosis was induced by ovariectomized in female Sprague-Daweley (SD) rats, and the prevention and treatment efficacy of the climacteric disease the ostmenopausal type I pattern was examined by using the experimental substance soybeans and arowroot. No clinical signs and mortality after continuous oral administration of experimental substances for 14 weeks were not observed, however, the weight of experimental animals underwent ovariectomized was increased significantly in comparison with control group (p<0.01). The atrophy of the uterus due to T3 group was 23.64% after 7 weeks, 24.44% after 14 weeks (in comparison with N.C. group), and it was statistically significantly increased. In regard to the change of blood cells, it was observed that platelets were statistically significantly reduced in the ovariectomized group, and administered orally experimental substances continuously for 7 weeks, in all groups administered experimental substances, it was found that platelets had the tendency to be increased more than N. C. group. In regard to He change of blood biochemistry, removed the ovary, the concentration of ALP showed the tendency to be increased than control group, and particularly in T3 group, it was increased significantly. In regard to the concentration of cholesterol, in comparison with negative control group, it was reduced 68% at 7 weeks and 35% at 14 weeks. After ovariectomized, the amount of estrogen was found to be reduced by 21.37% in comparison with control group, it showed the tendency to be increased by 4.49% in T1 group and 7.62% in T2 group, the concentration of estrogen in each group showed the tendency to be increased than negative control group, and in T3 group, it was increased to 100.46% and 117.65% in T4 group, and it was increased more than control group. Based on the above experimental results, in the experimental animals female rats, because of the hormonal imbalance induced by ovariectomized, a large mount of fat is accumulated in the body and due to it osteoporosis, obesity, hypertension, hyperlipidemia, fat of the liver, arteriosclerosis, diabetes, and other metabolic diseases were developed. Hence, when the experimental substance Extraction of ferment arrowroot was orally administered continuously for 14 weeks, it was thought that a certain proportion of the hormonal balance was maintained that functioned as a substance interfering the accumulation of fat, and it was considered to be of help in the treatment of not only osteoporosis Type I, but also for the prevention and treatment of various endocrinal diseases.

  • PDF

Comparison between Two Cryo-devices for Vitrification of Immature Oocytes of Indigenous Zebu Cows in Bangladesh

  • Choudhury, Sk Mohiuddin;Bhuiyan, Mohammad Musharraf Uddin;Rahman, Mohammad Moshiur;Rahman, Md. Masudur;Sharif, Md. Newaz;Bhattacharjee, Jayonta;Bari, Farida Yeasmin;Juyena, Nasrin Sultana
    • Journal of Embryo Transfer
    • /
    • v.32 no.4
    • /
    • pp.311-317
    • /
    • 2017
  • Cryopreservation of oocytes by vitrification technique may contribute a lot in the field of reproductive biotechnology. The objectives of the present study were to evaluate the effectiveness of two cryo-devices for vitrification of immature oocytes of indigenous zebu cows. Slaughter house derived immature cumulus-oocyte-complexes (COCs) of cows were vitrified using 15% dimethyl sulphoxide (DMSO) as cryoprotective agent (CPA) with 0.5 mol sucrose in TCM 199 supplemented with 20% FBS. Vitrification of COCs was completed after immediate plunging of COCs loaded cryotop or French mini straw into the liquid nitrogen ($LN_2$). Then the COCs containing cryotop or French mini straws were warmed in 0.25 mol sucrose and 20% FBS supplemented TCM 199 followed by in vitro culture in $50{\mu}l$ droplets of bicarbonate buffered TCM 199 supplemented with 10% FBS, pyruvate, FSH and oestradiol for 24 hrs at $39^{\circ}C$ with 5% CO2 in humidified air. After maturation culture, oocytes were denuded and examined under inverted microscope for presence of polar body as the indication of maturation. Denuded oocytes were also stained by whole mount technique using 1% orcein to examine the maturation by presence of MII chromosomes. The in vitro maturation rate was significantly (p<0.05) higher in oocytes vitrified and warmed using crytop ($47.1{\pm}6.9%$) than that of French mini straw ($15.9{\pm}12.5%$). Moreover, in vitro maturation rate was significantly (p<0.05) highe r in control oocytes (not vitrified) ($84.5{\pm}14.2%$) than that of vitrified oocytes. In conclusion, cryotop is better than French mini straw as cryo-device for vitrification of bovine immature oocytes.

Venerable Kim Ji-jang's Process of Becoming Ksitigarbha Bodhisattva (신라승 김지장(金地藏)의 지장보살화(地藏菩薩化) 과정)

  • An, Yang-gyu
    • Journal of the Daesoon Academy of Sciences
    • /
    • v.38
    • /
    • pp.153-182
    • /
    • 2021
  • The Buddhist monk, Kim Ji-jang (金地藏), a native of Silla, is still revered as Ksitigarbha Bodhisattva in China. In Chinese Buddhism, Kim Ji-jang's becoming Ksitigarbha Bodhisattva is unique in at least two ways. First, it is said that his becoming the bodhisattva originated not in Silla, but in China, a foreign country. Second, it is said that the historical person became regarded as a mythical being, Ksitigarbha Bodhisattva. The process of Kim Ji-jang's becoming Bodhisattva can be divided into three periods. The first period is the period of entering and practicing at Mount Jiuhua in China, and this also includes the period wherein he was first revered as Ksitigarbha Bodhisattva. The second period begins immediately after Kim Ji-jang's death and ends three years later. In this period he became regarded as Ksitigarbha Bodhisattva. The third period spans three years after his death to the present age. His status as Ksitigarbha Bodhisattva carries on at present. There are two main causes for Kim Ji-jang's transformation into the bodhisattva. The first is an internal bodhisattva process. According to Ksitigarbha Bodhisattva's main vow, Kim Ji-jang's practice and edification impressed the public. The second is an external bodhisattva process. The miracles that appeared at the time of his death or the manifestation of the incorruptible relics three years after his death played a decisive role in the process of Kim Ji-jang becoming a bodhisattva. In line with the public's devotion, the Chinese imperial family repaired and supported the temple that enshrined the relics of Kim Ji-jang. Various factors could be analyzed in the process of Kim Ji-jang's becoming Ksitigarbha Bodhisattva, but more than anything else, it was Kim Ji-jang's severe ascetic practices and his virtuous edification of others.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF