• Title/Summary/Keyword: Body Temperature Sensor

Search Result 161, Processing Time 0.031 seconds

The Design of an Automatic System for Dairy Cattle Breeding I - The Choice of Temperature Sensor for Body Temperature Measuring - (낙농의 자동화 시스템 구성 I - 체온 감지 온도센서의 선정 -)

  • 김형주;정길도;한병성;김용준;김동원;김명순
    • Journal of Biosystems Engineering
    • /
    • v.23 no.1
    • /
    • pp.83-90
    • /
    • 1998
  • In this paper the automatic system for dairy cattle has been desisted such as body temperature measuring unit, feed supplying unit and temperature control unit. Since e disease is strongly related to the body temperature of cattle, early detection of the abnormal temperature would prevent the severe problems which nay occur in dairy farms. An electronic component AD590J is used as temperature sensor for the system, The device is highly robust against the noise since the output signal is the current so it can be applied to a long distance sensing The resolution of signal is 0.1$^{\circ}C$ and the current is 10㎷ Also 12-bit A/D converter is desisted fir interfacing the sensor with a one-chip microprocessor. A temperature measuring experiment using the developed system has been done for measuring the temperature of human beings and the system was proven to be useful for measuring the body temperature of dairy cattle properly. A geared AC motor is used for the feed supplying unit The heater and fm are used as temperature control unit. The feed supplying unit and temperature control unit are well operating in the laboratory experiment.

  • PDF

Development of an Automatic Body Temperature Measuring System for Dairy Cattle (젖소의 자동 체온 측정 시스템 개발)

  • 정길도;김형주;김용준;한병성;김명순
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.140-143
    • /
    • 1996
  • In this paper the development of an automatic body temperature measuring system which can be attached to the milking machine has been studied. Since the disease is highly related to the body temperature of the cattle, early detection of the abnormal temperature would prevent the severe problems which may occur in dairy farms. The electronic component AD590 is used as a temperature sensor for the system. The device is highly robust against the noise since the output signal is the current. So it can be applied to the long distance sensing. The resolution of the signal is $0.1{\circ}C$ and the current is 10 mV. Also the A/D converter is designed for interfacing the sensor with a computer. A temperature measuring experiment using the developed system has been done for measuring the temperature of human beings and the system was proven to be useful for measuring the body temperature of the dairy cattle properly.

  • PDF

A Study of BioSignal Analysis for Physical Activity of Wu-Shu Training (우슈 수련자의 신체활동에 따른 생체신호 분석에 관한 연구)

  • Kim Chang-Mo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.6
    • /
    • pp.230-237
    • /
    • 2005
  • In this paper, we are suggested a method that's a major topics in sports medicine. It is disease control, control and management of chronic degenerative disease, and promotion of health. We are analyze physical activity to scientific and quantitative a trainee at Wu-Shu gymnasium, for a suggested method. We are measured a quantity of physical activity by SenseWear-PRO2-Armband which develop body-media company. Armband include to skin temperature sensor, near-body temperature sensor, accelerometer, heat flux sensor, galvanic skin response sensor. Acquired data was recorded to storage in Armband. We are analyzed using InnerView Wearer Software in the Stored data to skin temperature, calorie expenditure, quantity of physical activity. The result of this analyzed, we are know that a man of long-term exercise expenditure energy at short time and if liveliness of physical activity was Increase in expenditure energy with increase skin temperature. Also, we are know that the heat flux after increase expenditure energy with increase skin temperature. And, know that GSR was not affected a factors that physical activity, expenditure energy, increase skin temperature, and others.

  • PDF

A study on WSN based ECG and body temperature measuring system for ubiquitous healthcare: 1. the construction of sensor network platform (유비쿼터스 헬스케어를 위한 센서 네트워크 기반의 심전도 및 체온 측정 시스템: 1. 센서 네트워크 플랫폼 구축)

  • Lee, Young-Dong;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.362-370
    • /
    • 2006
  • The wireless sensor network (WSN) based ECG and body temperature measuring system for ubiquitous health-care were designed and developed. The system was composed of a wireless sensor network node, base station and server computer for the continuous monitoring of ECG signals and body temperatures of patients at home or hospital. ECG signal and body temperature data, important vital signals which are commonly used in clinical and trauma care, were displayed on a graphical user interface (GUI). The data transfer from sensor nodes on patients' body to server computer was accomplished through a base-station connected to a server computer using Zigbee compatible IEEE802.15.4 standard wireless communication. Real-time as well as historical, ECG data of elderly persons or patients, can also be retrieved and played back to assist the diagnosis. The ubiquitous health care system presented in this study can effectively reduce social medical expenses, which will be increased greatly in the coming aging society.

Development for body temperature sensor and monitoring telemetry system (체온측정용 온도 센서 및 모니터링 텔레메트리 시스템 구현)

  • Lee, Jyung-Hyun;Seong, Ki-Woong;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.435-442
    • /
    • 2010
  • Typically, the vital signs that are representing the state of human body, are the body temperature, sphygmus, respiration and blood pressure. The body temperature is the result of metabolic regulation and human steady-state body temperature is maintained from 35.9 to $37.4^{\circ}C$ by heat regulatory center. The body temperature is indicative of infection and especially it should be monitored to requiring intensive care patients or after surgical patients. But, measuring of body temperature to a heavy workload on nursing staff has been recognized. And, the health service of nurse is limited by simple tasks such as the measurement and record of vital sign. In this paper, the body temperature monitoring telemetry system was proposed to prove the recoding and transmission of body temperature patch system according the standard(ISO TS11073-92001). We proposed the transmission protocol to suit the MFER(medical waveform format encoding rules). The telemetry patch system was implemented and it was verified by experiments.

Wearable Human Health-monitoring Band using Inkjet-printed Flexible Temperature Sensor

  • Han, Dong Cheul;Shin, Han Jae;Yeom, Se Hyeok;Lee, Wanghoon
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.301-305
    • /
    • 2017
  • This paper presents a wearable human health-monitoring band. The band consists of a body temperature detector (BTD) and a hear rate detector (HRD). The BTD and HRD are realized using an inkjet-printed flexible temperature sensor and a commercial heart rate sensor module, respectively. The sensitivity of the fabricated BTD was found to be $-31/^{\circ}C$ with a linearity of 99.82%. The HRD using the commercial heart rate sensor module has a good performance with a standard deviation of 0.85 between the data of a commercial smart watch and the fabricated HRD.

ECG & Temperature Measurement Wireless Sensor used Ag/AgCl Thin-Film (Ag/Agcl 박막을 이용한 ECG 및 온도 측정용 무선센서)

  • Lim, Jin-Hee;Nam, Hyo-Duck;Jung, Woo-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.342-343
    • /
    • 2007
  • In this paper, we developed an integrated miniaturized device which acquires and transmits the signal of ECG an interested heartbeat and body's temperature. Electrocardiogram(ECG) is a recording of the electrical activity on the body surface generated by heart. ECG & temperature measurement is collected by wireless sensor (for Ag/AgCl Thin-Film) placed at designated locations on the body. It is that dual wireless sensor will apply variously to Ubiquitous & Healthcare System.

  • PDF

Operating Characteristic Analysis of Optic Temperature Sensor for Overheat Detection in Panel Board (분전함에서 이상발열 감지를 위한 광온도센서의 동작특성 분석)

  • Moon, Hyun-Wook;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.100-106
    • /
    • 2009
  • In this study, methods of overheat detection at the coupling or wire in electrical facility are investigated, operating characteristic about the optic temperature sensor for continuous on-line temperature monitoring in diagnostics system of electrical facility is analyzed. Heating sources in the experiment for operating characteristics of optic temperature sensor use black body and hot plate, output voltage of optic temperature sensor in accordance with temperature variation is analyzed. Overheat generation due to poor contact at the circuit breaker in panel board detects using a thermocouple, infrared thermal camera and optic temperature sensor, and experiment results are analyzed. The effect of optic temperature sensor is the same that of other methods. These results expect to use basic research material for adjusting field of electrical diagnostics system using RFID type optic temperature sensor in the near future.

Design of Implantable Wireless Sensor Node to Monitor the Livestock Body Temperature (가축의 실시간 체온 측정을 위한 이식형 무선 센서 노드 설계)

  • Kim, Hyun-Joong;Yang, Hyun-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.585-588
    • /
    • 2009
  • Wireless Sensor Network (WSN) is consisted of lots of tiny sensor nodes with limited processing power and computing resources. Thus, the most critical and fundamental element of WSN technology is sensor node, which gathers environmental information and transmits it to the user application systems. Due to the technological advancement, sensor nodes are become smaller and more intelligent, hence, expand their application area. Specifically, implantable wireless sensor node technology, to monitor and treat disease by implanting tiny sensor nodes into human body or livestock, shows further directions of WSN. In this paper, we have designed an implantable wireless sensor node to monitor livestock body temperature in real time. We also discussed on the additional considerations to implement real time bio-monitoring systems.

  • PDF

An Analysis on the Effects of Cluster Leadership Rotation among Nodes Using Least Temperature Routing Protocol

  • Encarnacion, Nico;Yang, Hyunho
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.2
    • /
    • pp.104-108
    • /
    • 2014
  • The field of body sensor networks has attracted interest of many researchers due to its potential to revolutionize medicine. These sensors are usually implanted inside the human body and communicate among themselves. In the process of receiving, processing, or transmitting data, these devices produce heat. This heat damages the tissues surrounding the devices in the case of prolonged exposure. In this paper, to reduce this damages, we have improved and evaluated two protocols-the least temperature routing protocol and adaptive least temperature routing protocol-by implementing clustering as well as a leadership rotation algorithm. We used Castalia to simulate a basic body area network cluster composed of 6 nodes. A throughput application was used to simulate all the nodes sending data to one sink node. Simulations results shows that improved communication protocol with leadership rotation algorithm significantly reduce the energy consumption as compared to a scheme without leadership rotation algorithm.