• Title/Summary/Keyword: Body Network

Search Result 778, Processing Time 0.031 seconds

Communication Failure Resilient Improvement of Distributed Neural Network Partitioning and Inference Accuracy (통신 실패에 강인한 분산 뉴럴 네트워크 분할 및 추론 정확도 개선 기법)

  • Jeong, Jonghun;Yang, Hoeseok
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.16 no.1
    • /
    • pp.9-15
    • /
    • 2021
  • Recently, it is increasingly necessary to run high-end neural network applications with huge computation overhead on top of resource-constrained embedded systems, such as wearable devices. While the huge computational overhead can be alleviated by distributed neural networks running on multiple separate devices, existing distributed neural network techniques suffer from a large traffic between the devices; thus are very vulnerable to communication failures. These drawbacks make the distributed neural network techniques inapplicable to wearable devices, which are connected with each other through unstable and low data rate communication medium like human body communication. Therefore, in this paper, we propose a distributed neural network partitioning technique that is resilient to communication failures. Furthermore, we show that the proposed technique also improves the inference accuracy even in case of no communication failure, thanks to the improved network partitioning. We verify through comparative experiments with a real-life neural network application that the proposed technique outperforms the existing state-of-the-art distributed neural network technique in terms of accuracy and resiliency to communication failures.

Experimental Study on the Effect of Antenna Polarization in WBAN Off-Body Channel (WBAN Off-Body 채널에서 안테나 편파의 영향 분석)

  • Jeon, Jaesung;Ahn, Byoungjik;Kim, Sunwoo;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.144-151
    • /
    • 2013
  • This paper investigates the effect of antenna polarization in Wireless Body Area Network(WBAN) off-body channel. The polarizations of antenna are divided into four combinations regarding Line-of-Sight(LOS) and Non-LOS(NLOS) environment. The human body keeps both still standing and moving to show that the impact of the polarization to signal. This paper confirms the performance depending on the polarization of receiver antenna and the combination of the polarizations on the off-body channel.

WBAN LI Protocol for Improving Lifetime of Implant Sensor in Body (WBAN에서 신체 내부 센서의 라이프타임 향상을 위한 LI 프로토콜)

  • Park, Jinchul;Lee, Jongkyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.18-25
    • /
    • 2014
  • A implanted sensor's error probability is more likely to external sensor's error probability by biological characteristic in WBAN. In this paper, we present method that external sensor transmits frame instead of doing implanted sensor's retransmission for improving lifetime of implanted sensors in WBAN. The proposed method, LI(Lifetime Increment) protocol is to add external sensor's id in transmission data frame of a implanted sensor. When the retransmission is required, external sensor that have to registered id in data frame retransmits frame instead of implanted sensors' retransmission. The comparison result shows that the proposed protocol reduces power consumption and improves life time.

Keypoints-Based 2D Virtual Try-on Network System

  • Pham, Duy Lai;Ngyuen, Nhat Tan;Chung, Sun-Tae
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.2
    • /
    • pp.186-203
    • /
    • 2020
  • Image-based Virtual Try-On Systems are among the most potential solution for virtual fitting which tries on a target clothes into a model person image and thus have attracted considerable research efforts. In many cases, current solutions for those fails in achieving naturally looking virtual fitted image where a target clothes is transferred into the body area of a model person of any shape and pose while keeping clothes context like texture, text, logo without distortion and artifacts. In this paper, we propose a new improved image-based virtual try-on network system based on keypoints, which we name as KP-VTON. The proposed KP-VTON first detects keypoints in the target clothes and reliably predicts keypoints in the clothes of a model person image by utilizing a dense human pose estimation. Then, through TPS transformation calculated by utilizing the keypoints as control points, the warped target clothes image, which is matched into the body area for wearing the target clothes, is obtained. Finally, a new try-on module adopting Attention U-Net is applied to handle more detailed synthesis of virtual fitted image. Extensive experiments on a well-known dataset show that the proposed KP-VTON performs better the state-of-the-art virtual try-on systems.

A Lightweight Integrity Authentication Scheme based on Reversible Watermark for Wireless Body Area Networks

  • Liu, Xiyao;Ge, Yu;Zhu, Yuesheng;Wu, Dajun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.12
    • /
    • pp.4643-4660
    • /
    • 2014
  • Integrity authentication of biometric data in Wireless Body Area Network (WBAN) is a critical issue because the sensitive data transmitted over broadcast wireless channels could be attacked easily. However, traditional cryptograph-based integrity authentication schemes are not suitable for WBAN as they consume much computational resource on the sensor nodes with limited memory, computational capability and power. To address this problem, a novel lightweight integrity authentication scheme based on reversible watermark is proposed for WBAN and implemented on a TinyOS-based WBAN test bed in this paper. In the proposed scheme, the data is divided into groups with a fixed size to improve grouping efficiency; the histogram shifting technique is adopted to avoid possible underflow or overflow; local maps are generated to restore the shifted data; and the watermarks are generated and embedded in a chaining way for integrity authentication. Our analytic and experimental results demonstrate that the integrity of biometric data can be reliably authenticated with low cost, and the data can be entirely recovered for healthcare applications by using our proposed scheme.

Performance testing of a FastScan whole body counter using an artificial neural network

  • Cho, Moonhyung;Weon, Yuho;Jung, Taekmin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3043-3050
    • /
    • 2022
  • In Korea, all nuclear power plants (NPPs) participate in annual performance tests including in vivo measurements using the FastScan, a stand type whole body counter (WBC), manufactured by Canberra. In 2018, all Korean NPPs satisfied the testing criterion, the root mean square error (RMSE) ≤ 0.25, for the whole body configuration, but three NPPs which participated in an additional lung configuration test in the fission and activation product category did not meet the criterion. Due to the low resolution of the FastScan NaI(Tl) detectors, the conventional peak analysis (PA) method of the FastScan did not show sufficient performance to meet the criterion in the presence of interfering radioisotopes (RIs), 134Cs and 137Cs. In this study, we developed an artificial neural network (ANN) to improve the performance of the FastScan in the lung configuration. All of the RMSE values derived by the ANN satisfied the criterion, even though the photopeaks of 134Cs and 137Cs interfered with those of the analytes or the analyte photopeaks were located in a low-energy region below 300 keV. Since the ANN performed better than the PA method, it would be expected to be a promising approach to improve the accuracy and precision of in vivo FastScan measurement for the lung configuration.

Evaluation of Waist Pressure Using Electroencephalogram(EEG) Signal (뇌파를 이용한 허리 압박감 평가 기술)

  • Kim, Dong-Jun;Woo, Seung-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1190-1195
    • /
    • 2011
  • This paper presents a waist pressure evaluation method in human sensibility using a electroencephalogram(EEG) signal. For this objective, a size-controllable waist-belt is used. First of all, EEG signals for relaxed state are acquired. Then, the waist-belt of the subject is tightened about 90% of normal state. After a few minutes, the belt of the subject is released. Some necessary preprocessing is performed on the acquired signals, Linear Prediction (LP) coefficients are utilized as the feature parameters extracting the characteristics of EEG signal, and a multi-layer neural network is used for indicating the state of body pressure. The results of the method showed 77.2% of coincidence with body pressure states. This may be compromising results for ssubject-independent sensibility evaluation using EEG signal.

Holistic Scheduling Analysis of a CAN based Body Network System (CAN을 이용한 차체 네트웍 시스템에 대한 Holistic 스케줄링 해석)

  • 신민석;이우택;선우명호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.114-120
    • /
    • 2002
  • In a distributed real-time control system, it is essential to confirm the timing behavior of all tasks because these tasks of each real-time controller have to finish their processes within the specified time intervals called a deadline. In order to satisfy this objective, the timing analysis of a distributed real-time system such as shcedulability test must be performed during the system design phase. In this study, a simple application of CAN fur a vehicle body network system is formulated to apply to a holistic scheduling analysis, and the worst-case execution time (WCET) and the worst-case end-to-end response time (WCRT) are evaluated in the point of holistic system view.

Real-Time Analysis of Occupant Motion for Vehicle Simulator

  • Oh, Kwang-Seok;Son, Kwon;Kim, Kwang-Hoon;Oh, Sang-Min;Choi, Kyung-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.129.2-129
    • /
    • 2001
  • Visual effects are important cues for providing occupant s with virtual reality in a vehicle simulator which imitates real driving. The viewpoint of an occupant is sensitively dependent upon the occupant´s posture, therefore, the total body motion must be considered in a graphic simulator. A real time simulation is required for the dynamic analysis of complex human body motion. This study attempts to apply a neural network to the motion analysis in various driving situations. A full car of medium-sized vehicles was selected and modeled, and then analyzed using ADAMS in such driving conditions as bump-pass and acceleration. A multibody system analysis software, MADYMO, was used in the motion analysis of an adult male dummy in the seated position. Position data of the head were collected as inputs to the viewpoint movement. Based on these data, a back- propagation neural network was ...

  • PDF

The Development of Body Control Module using In Vehicle Network

  • Lee, Seong-Hun;Wu, Son-Jun;Lee, Suk;Choi, Bong-Yeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.174.2-174
    • /
    • 2001
  • Increasing demand for safety features, driving comfort and operational convenience in automobiles requires an intensive use of electronic components such as sensors, actuators and Electronic Control Unit(ECU)'s. These growing number of electronics has given rise to problems concerning the increasing number, size and weight of the wiring harnesses. In order to resolve these problems, multiplexed wiring systems such as Controller Area Network(CAN) serial communication protocol are applied in vehicle. This paper introduces the development of Body Control Module(BCM)s using multiplexed wiring systems. The BCM's were developed and implemented using CAN, the most popular choice of in-vehicle communication protocols.

  • PDF