• Title/Summary/Keyword: Bobbin

Search Result 118, Processing Time 0.031 seconds

Prediction and Analysis of Bobbin ECT Signals generated by Tube Defects near Support Plate (지지대 부근의 전열관 결함으로 인해 발생되는 보빈 와전류신호의 예측 및 분석)

  • Shin, Young-Kil;Lee, Yun-Tai
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.942-944
    • /
    • 2005
  • In this study, eddy current signals from various anomalous defects in the heat exchanger tube are predicted af their signal slope characteristics no analyzed. The signal changes due to frequency increase are also observed. Based in the accumulated knowledge, the analysis of superimposed signal is attempted which includes the effects of support plate. Both differential and absolute bobbin probe signals are analyzed. For the prediction of signals, axisymmetric finite element modeling is used and this leads us to the utilization of slope angle analysis of the signal. Results show that differential signals are useful to locate the position of defect under the support plate and absolute signals no easy to predict and analyze even though they no superimposed signals. Combined use of these two types of signals will accomplish a reliable inspection.

  • PDF

A Study on the Expandable Bobbin Type Multiple Integrated Coupled-Inductor Applied 4-Pralleled Switching Rectifier (보빈 적층 방식의 다중 공유결합 인덕터를 이용한 4병렬 스위칭 정류기에 관한 연구)

  • Yoo, Jeong Sang;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.18-24
    • /
    • 2019
  • In this paper, expandable bobbin type multiple integrated coupled-inductor applied 4-paralled switching rectifier was proposed. To design the proposed inductor easily, inductance designing formula was derived through magnetic circuit analysis of the 4-paralleled integrated coupled-inductor. Furthermore, to verify practicality of the proposed inductor, it was applied in 600W class 4-paralleled interleaved switching rectifier, and the steady-state characteristics of the proposed inductor and discrete inductors were compared. Consequently, it was showed that the proposed inductor can replace the conventional discrete inductors with alternative electrical characteristic standard, hence miniaturization of the SMPS can be achieved. From the test result, test circuit with the proposed inductor showed maximum 97.1% of power conversion efficiency and under 18W of power loss where the circuit with discrete inductors showed 96.7% and 20W respectively.

Detectability evaluation of the loose parts in steam generator by eddy current testing techniques

  • Kim, Kyungcho;Min, Kyongmahn;Kim, Changkuen;Kim, Jin-Gyum;Jhung, Myungjo
    • Nuclear Engineering and Technology
    • /
    • v.50 no.7
    • /
    • pp.1160-1167
    • /
    • 2018
  • Detectability of the loose parts (LPs) in steam generator (SG) was studied with eddy current testing technique such as X-probe, bobbin and rotating coils ($MRPC^{(R)}$) as a function of LP size and spacing between LP and tube or between LP and support structures. SG mockup simulating SG tube and support structures with LP was fabricated. The X-probe showed slightly better detectability than $MRPC^{(R)}$ for LP of ferrous (F-LP) material and vice versa for LP of nonferrous (NF-LP) material. In terms of feasibility, inspection rate and other predictable features of the SG tubing inspections, X-probe can be used reliably for monitoring the LPs and the flaws formed by LPs on SG tubes.

Detection of Foreign Objects Using Bobbin Probe in Eddy Current Test (이물질에 대한 ECT Bobbin Probe 검출 감도)

  • Jung, Hee-Sung;Kweon, Young-Ho;Lee, Dong-Ha;Shin, Wook-Jo;Yim, Chan-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.295-299
    • /
    • 2016
  • Residual foreign objects at the secondary side (top of the tubesheet and tube support plates) of a steam generator are likely to cause a leak by causing wear in the tube. The extent of wear is significantly affected by the material, shape, and size of the foreign object, and the corrosion properties of the tube. The presence of foreign objects at the top of the tubesheet and tube support plates has been identified using remote visual inspection methods such as the foreign object search and retrieval and eddy current test (ECT). The detection of the residual foreign object at the secondary side of a steam generator has limitations that depend on the material properties and the condition of contact with the tube. In this study, which is vertical and horizontal from the upper tubesheet, the corresponding bobbin ECT signals were collected and analyzed to measure its ability to detect foreign objects.

Development of ETSS for the SG Secondary Side Loose Part Signal Detection and Characterization (SG전열관 2차측 이물질 검출 및 특성분석을 위한 ETSS 개발)

  • Shin, Ki Seok;Moon, Yong Sig;Min, Kyong Mahn
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.61-66
    • /
    • 2011
  • The integrity of the SG(Steam Generator) tubes has been challenged by numerous factors such as flaws, operation, atmosphere, inherently degraded materials, loose parts and even human errors. Of the factors, loose parts(or foreign materials) on the secondary side of the tubes can bring about volumetric defects and even leakage from the primary to the secondary side in a short period of time. More serious concerns about the loose parts are their unknown influx path and rapid growth rate of the defects affected by the loose parts. Therefore it is imperative to detect and characterize the foreign materials and the defects. As a part of the measures for loose part detection, TTS(Top of Tubesheet) MRPC(Motorized Rotating Pancake Coils) ECT has been carried out especially to the restricted high probability area of the loose part. However, in the presence of loose parts in the other areas, wide range loose part detection techniques are required. In this study, loose part standard tube was presented as a way to accurately detect and characterize loose part signals. And the SG tube ECT bobbin coil and MRPC ISI(In-service Inspection) data of domestic OPR-1000 and Westinghouse Model F(W_F) were reviewed and consequently, comprehensive loose part detection technique is derived especially by applying bobbin coil signals

Scale Thickness Measurement of Steam Generator Tubing Using Eddy Current Signal of Bobbin Coil (보빈코일 와전류신호를 이용한 증기발생기 세관 스케일 두께 측정)

  • Kim, Chang-Soo;Um, Ki-Soo;Kim, Jae-Dong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.545-550
    • /
    • 2012
  • Steam generator is one of the major components of nuclear power plant and steam generator tubes are the pressure boundary between primary and secondary side, which makes them critical for nuclear safety. As the operating time of nuclear power plant increases, not only damage mechanisms but also scaled deposits on steam generator tubes are known to be problematic causing tube support flow hole blockage and heat fouling. The ability to assess the extent and location of scaled deposits on tubes became essential for management and maintenance of steam generator and eddy current bobbin data can be utilized to measure thickness of scale on tubes. In this paper, tube reference standards with various thickness of scaled deposit has been set up to provide information about the overall deposit condition of steam generator tubes, providing essential tool for steam generator management and maintenance to predict and prevent future damages. Also, methodology to automatically measure scale thickness on tubes has been developed and applied to field data to estimate overall scale amount.

Automated Analysis Technique Developed for Detection of ODSCC on the Tubes of OPR1000 Steam Generator

  • Kim, In Chul;Nam, Min Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.6
    • /
    • pp.519-523
    • /
    • 2013
  • A steam generator (SG) tube is an important component of a nuclear power plant (NPP). It works as a pressure boundary between the primary and secondary systems. The integrity of a SG tube can be assessed by an eddy current test every outage. The eddy current technique(adopting a bobbin probe) is currently the main technique used to assess the integrity of the tubing of a steam generator. An eddy current signal analyst for steam generator tubes continuously analyzes data over a given period of time. However, there are possibilities that the analyst conducting the test may get tired and cause mistakes, such as: missing indications or not being able to separate a true defect signal from one that is more complicated. This error could lead to confusion and an improper interpretation of the signal analysis. In order to avoid these possibilities, many countries of opted for automated analyses. Axial ODSCC (outside diameter stress corrosion cracking) defects on the tubes of OPR1000 steam generators have been found on the tube that are in contract with tube support plates. In this study, automated analysis software called CDS (computer data screening) made by Zetec was used. This paper will discuss the results of introducing an automated analysis system for an axial ODSCC on the tubes of an OPR1000 steam generator.